ABSTRACT

Background

In 2016, we reported the first case of high flow priapism and arteriocavernosal fistula caused by penile prosthesis insertion that mimicked device autoinflation.

Aim

To raise awareness amongst implanters, we describe further cases from our institution and perform a systematic review of the literature to understand the rarity of this phenomenon.

Methods

Patient demographics, management and outcomes were extracted retrospectively. A systematic search of the EMBASE, PubMed and PubMed Central libraries for studies reporting arteriocavernosal fistula mimicking autoinflation since 1946 was performed.

Outcomes

To identify and report all known cases of high flow priapism and arteriocavernosal fistula presenting as autoinflation of an inflatable penile prosthesis.

Results

Four patients in total (median age 56, range 46-60 years) were identified. Catastrophic bleeding (1.8L) occurred during revision surgery for presumed autoinflation in Patient 1 and subsequent ultrasound (US) confirmed a fistula which was embolized. Patient 2 redeveloped autoinflation following revision surgery. Ultrasound confirmed high flow priapism from an arteriocavernosal fistula. Patient 3 underwent penile magnetic resonance imaging (MRI) to investigate autoinflation and residual penile curvature. MRI showed a tumescent penis despite a deflated device and the fistula was embolized successfully. Patient 4 with sleep-related painful erections did not improve following insertion of penile prosthesis. Doppler US identified 2 fistulae that was embolized but with no resolution of symptoms. Subsequent embolization of both common penile arteries were done to control his symptoms. No other publications apart from the published abstract from 2016 reporting patient 1 was found.

Clinical Implications

If considered prior to revision surgery, the fistula can be managed safely by minimally invasive percutaneous angioembolisation avoiding surgery which can potentially be associated with significant complications.

Strengths and Limitations

The rarity of this phenomenon was supported by a systematic review. Our study however does present the findings from a small number of patients.

Conclusion

Damage to the cavernosal artery during inflatable penile prosthesis insertion can create an arteriocavernosal fistula that mimics autoinflation, leading to catastrophic intra-operative bleeding or unnecessary surgery.