The short-term scaling exponent alpha1 of detrended fluctuation analysis (DFA a1), a nonlinear index of heart rate variability (HRV) based on fractal correlation properties, has been shown to steadily change with increasing exercise intensity. To date, no study has specifically examined using the behavior of this index as a method for defining a low intensity exercise zone. The aim of this report is to compare both oxygen intake (VO2) and heart rate (HR) reached at the first ventilatory threshold (VT1), a well-established delimiter of low intensity exercise, to those derived from a predefined DFA a1 transitional value. Gas exchange and HRV data were obtained from 15 participants during an incremental treadmill run. Comparison of both VO2 and HR reached at VT1 defined by gas exchange (VT1 GAS) was made to those parameters derived from analysis of DFA a1 reaching a value of 0.75 (HRVT). Based on Bland Altman analysis, linear regression, intraclass correlation (ICC) and t testing, there was strong agreement between VT1 GAS and HRVT as measured by both HR and VO2. Mean VT1 GAS was reached at 39.8 ml/kg/min with a HR of 152 bpm compared to mean HRVT which was reached at 40.1 ml/kg/min with a HR of 154 bpm. Strong linear relationships were seen between test modalities, with Pearson’s r values of 0.99 (p < 0.001) and.97 (p < 0.001) for VO2 and HR comparisons, respectively. Intraclass correlation between VT1 GAS and HRVT was 0.99 for VO2 and 0.96 for HR. In addition, comparison of VT1 GAS and HRVT showed no differences by t testing, also supporting the method validity. In conclusion, it appears that reaching a DFA a1 value of 0.75 on an incremental treadmill test is closely associated with crossing the first ventilatory threshold. As training intensity below the first ventilatory threshold is felt to have great importance for endurance sport, utilization of DFA a1 activity may provide guidance for a valid low training zone.
Exercise and training prescription in endurance-type sports has a strong theoretical background with various practical applications based on threshold concepts. Given the challenges and pitfalls of determining individual training zones on the basis of subsystem indicators (e.g., blood lactate concentration, respiratory parameters), the question arises whether there are alternatives for intensity distribution demarcation. Considering that training in a low intensity zone substantially contributes to the performance outcome of endurance athletes and exceeding intensity targets based on a misleading aerobic threshold can lead to negative performance and recovery effects, it would be desirable to find a parameter that could be derived via non-invasive, low cost and commonly available wearable devices. In this regard, analytics conducted from non-linear dynamics of heart rate variability (HRV) have been adapted to gain further insights into the complex cardiovascular regulation during endurance-type exercise. Considering the reciprocal antagonistic behavior and the interaction of the sympathetic and parasympathetic branch of the autonomic nervous system from low to high exercise intensities, it may be promising to use an approach that utilizes information about the regulation quality of the organismic system to determine training-intensity distribution. Detrended fluctuation analysis of HRV and its short-term scaling exponent alpha1 (DFA-alpha1) seems suitable for applied sport-specific settings including exercise from low to high intensities. DFA-alpha1 may be taken as an indicator for exercise prescription and intensity distribution monitoring in endurance-type sports. The present perspective illustrates the potential of DFA-alpha1 for diagnostic and monitoring purposes as a "global" system parameter and proxy for organismic demands.
Past attempts to define an anaerobic threshold (AnT) have relied upon gas exchange kinetics, lactate testing and field-based evaluations. DFA a1, an index of heart rate (HR) variability (HRV) fractal correlation properties, has been shown to decrease with exercise intensity. The intent of this study is to investigate whether the AnT derived from gas exchange is associated with the transition from a correlated to uncorrelated random HRV pattern signified by a DFA a1 value of 0.5. HRV and gas exchange data were obtained from 15 participants during an incremental treadmill run. Comparison of the HR reached at the second ventilatory threshold (VT2) was made to the HR reached at a DFA a1 value of 0.5 (HRVT2). Based on Bland–Altman analysis and linear regression, there was strong agreement between VT2 and HRVT2 measured by HR (r = 0.78, p < 0.001). Mean VT2 was reached at a HR of 174 (±12) bpm compared to mean HRVT2 at a HR of 171 (±16) bpm. In summary, the HR associated with a DFA a1 value of 0.5 on an incremental treadmill ramp was closely related to that of the HR at the VT2 derived from gas exchange analysis. A distinct numerical value of DFA a1 representing an uncorrelated, random interbeat pattern appears to be associated with the VT2 and shows potential as a noninvasive marker for training intensity distribution and performance status.
Studies highlight the usage of non-linear time series analysis of heart rate variability (HRV) using the short-term scaling exponent alpha1 of Detrended Fluctuation Analysis (DFA-alpha1) during exercise to determine aerobic and anaerobic thresholds. The present study aims to further verify this approach in women. Gas exchange and HRV data were collected from 26 female participants with different activity levels. Oxygen uptake (VO2) and heart rate (HR) at first (VT1) and second ventilatory thresholds (VT2) were compared with DFA-alpha1-based thresholds 0.75 (HRVT1) and 0.50 (HRVT2). Results: VO2 at VT1 and VT2 were 25.2 ml/kg/min (± 2.8) and 31.5 ml/kg/min (± 3.6) compared with 26.5 ml/kg/min (± 4.0) and 31.9 ml/kg/min (± 4.5) for HRVT1 and HRVT2, respectively (ICC3,1 = 0.77, 0.84; r = 0.81, 0.86, p < 0.001). The mean HR at VT1 was 147 bpm (± 15.6) and 167 bpm (± 12.7) for VT2, compared with 152 bpm (± 15.5) and 166 bpm (± 13.2) for HRVT1 and HRVT2, respectively (ICC3,1 = 0.87, 0.90; r = 0.87, 0.90, p < 0.001). Bland–Altman analysis for VT1 vs. HRVT1 showed a mean difference of − 1.3 ml/kg/min (± 2.4; LoA: 3.3, − 6.0 ml/kg/min) for VO2 and of − 4.7 bpm (± 7.8; LoA: 10.6, − 20.0 bpm) for HR. VT2 vs. HRVT2 showed a mean difference of − 0.4 ml/kg/min (± 2.3; LoA: 4.1, − 4.9 ml/kg/min) for VO2 and 0.5 bpm (± 5.7; LoA: 11.8, − 10.8 bpm) for HR. DFA-alpha1-based thresholds showed good agreement with traditionally used thresholds and could be used as an alternative approach for marking organismic transition zones for intensity distribution in women.
Recent study points to the value of a non-linear heart rate variability (HRV) biomarker using detrended fluctuation analysis (DFA a1) for aerobic threshold determination (HRVT). Significance of recording artefact, correction methods and device bias on DFA a1 during exercise and HRVT is unclear. Gas exchange and HRV data were obtained from 17 participants during an incremental treadmill run using both ECG and Polar H7 as recording devices. First, artefacts were randomly placed in the ECG time series to equal 1, 3 and 6% missed beats with correction by Kubios software’s automatic and medium threshold method. Based on linear regression, Bland Altman analysis and Wilcoxon paired testing, there was bias present with increasing artefact quantity. Regardless of artefact correction method, 1 to 3% missed beat artefact introduced small but discernible bias in raw DFA a1 measurements. At 6% artefact using medium correction, proportional bias was found (maximum 19%). Despite this bias, the mean HRVT determination was within 1 bpm across all artefact levels and correction modalities. Second, the HRVT ascertained from synchronous ECG vs. Polar H7 recordings did show an average bias of minus 4 bpm. Polar H7 results suggest that device related bias is possible but in the reverse direction as artefact related bias.
While established methods for determining physiologic exercise thresholds and intensity distribution such as gas exchange or lactate testing are appropriate for the laboratory setting, they are not easily obtainable for most participants. Data over the past two years has indicated that the short-term scaling exponent alpha1 of Detrended Fluctuation Analysis (DFA a1), a heart rate variability (HRV) index representing the degree of fractal correlation properties of the cardiac beat sequence, shows promise as an alternative for exercise load assessment. Unlike conventional HRV indexes, it possesses a dynamic range throughout all intensity zones and does not require prior calibration with an incremental exercise test. A DFA a1 value of 0.75, reflecting values midway between well correlated fractal patterns and uncorrelated behavior, has been shown to be associated with the aerobic threshold in elite, recreational and cardiac disease populations and termed the heart rate variability threshold (HRVT). Further loss of fractal correlation properties indicative of random beat patterns, signifying an autonomic state of unsustainability (DFA a1 of 0.5), may be associated with that of the anaerobic threshold. There is minimal bias in DFA a1 induced by common artifact correction methods at levels below 3% and negligible change in HRVT even at levels of 6%. DFA a1 has also shown value for exercise load management in situations where standard intensity targets can be skewed such as eccentric cycling. Currently, several web sites and smartphone apps have been developed to track DFA a1 in retrospect or in real-time, making field assessment of physiologic exercise thresholds and internal load assessment practical. Although of value when viewed in isolation, DFA a1 tracking in combination with non-autonomic markers such as power/pace, open intriguing possibilities regarding athlete durability, identification of endurance exercise fatigue and optimization of daily training guidance.
Heart rate variability (HRV) is frequently applied in sport-specific settings. The rising use of freely accessible applications for its recording requires validation processes to ensure accurate data. It is the aim of this study to compare the HRV data obtained by the Polar H10 sensor chest strap device and an electrocardiogram (ECG) with the focus on RR intervals and short-term scaling exponent alpha 1 of Detrended Fluctuation Analysis (DFA a1) as non-linear metric of HRV analysis. A group of 25 participants performed an exhaustive cycling ramp with measurements of HRV with both recording systems. Average time between heartbeats (RR), heart rate (HR) and DFA a1 were recorded before (PRE), during, and after (POST) the exercise test. High correlations were found for the resting conditions (PRE: r = 0.95, rc = 0.95, ICC3,1 = 0.95, POST: r = 0.86, rc = 0.84, ICC3,1 = 0.85) and for the incremental exercise (r > 0.93, rc > 0.93, ICC3,1 > 0.93). While PRE and POST comparisons revealed no differences, significant bias could be found during the exercise test for all variables (p < 0.001). For RR and HR, bias and limits of agreement (LoA) in the Bland–Altman analysis were minimal (RR: bias of 0.7 to 0.4 ms with LoA of 4.3 to −2.8 ms during low intensity and 1.3 to −0.5 ms during high intensity, HR: bias of −0.1 to −0.2 ms with LoA of 0.3 to −0.5 ms during low intensity and 0.4 to −0.7 ms during high intensity). DFA a1 showed wider bias and LoAs (bias of 0.9 to 8.6% with LoA of 11.6 to −9.9% during low intensity and 58.1 to −40.9% during high intensity). Linear HRV measurements derived from the Polar H10 chest strap device show strong agreement and small bias compared with ECG recordings and can be recommended for practitioners. However, with respect to DFA a1, values in the uncorrelated range and during higher exercise intensities tend to elicit higher bias and wider LoA.
The classification of endurance exercise fatigue encompasses diverse models and theories (Abbiss & Laursen, 2005), components (Carriker, 2017), and various aspects of muscular function (Wan et al., 2017), biochemical balance (Jastrzębski et al., 2015) as well as both the central and peripheral nervous systems
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.