Undetectable luteinizing hormone levels using a monoclonal immunometric assay
- PMID: 8787959
- DOI: 10.1007/BF03349815
Undetectable luteinizing hormone levels using a monoclonal immunometric assay
Abstract
Previous studies have shown wide discrepancies among the results obtained with different immunometric assays. We present five cases (out of 4000 women) whose plasma luteinizing hormone was not detected using a LH immunometric assay (LH Stratus Baxter) but was recognized by other kits. These cases concerned one 28-year-old woman presenting with infertility and four postmenopausal women. The LH Amerlite kit gave detectable but low results. The results obtained with the other kits were > 7 IU/l. FSH levels were > 7 IU/l. In one case, sera were taken before and after the menopause; differences between the LH results increased. Discrepancies among LH assay kits have been attributed to variation both in standard curve calibration and in epitope specificity of the kit monoclonal antibodies. The Baxter kit might misrecognize some isoforms present in postmenopausal women. The present data illustrate the potential false results with such immunoassays in routine clinical laboratory testing. When undetectable LH results are not clinically explained or when disparities between LH and FSH are observed, we suggest using a second methodology or a bioassay if necessary. Improvement in LH assays and standardization might resolve the problem of discrepancies between the LH results.
Similar articles
-
Heterogeneity of plasma gonadotropins. Consequences on immunological properties of LH.Nucl Med Biol. 1994 Apr;21(3):349-57. doi: 10.1016/0969-8051(94)90058-2. Nucl Med Biol. 1994. PMID: 9234300 Review.
-
Interest of epitopic dissection in immunoanalysis of proteins and peptides: review of theoretical and practical aspects.Eur J Clin Chem Clin Biochem. 1996 Sep;34(9):741-8. Eur J Clin Chem Clin Biochem. 1996. PMID: 8891527 Review.
-
A comparison of 13 different immunometric assay kits for gonadotropins: implications for clinical investigation.J Clin Endocrinol Metab. 1994 Jul;79(1):240-7. doi: 10.1210/jcem.79.1.8027235. J Clin Endocrinol Metab. 1994. PMID: 8027235
-
European collaborative study on luteinizing hormone assay: 2. Discrepancy among assay kits is related to variation both in standard curve calibration and epitope specificity of kit monoclonal antibodies.J Endocrinol Invest. 1994 Jun;17(6):407-16. doi: 10.1007/BF03347727. J Endocrinol Invest. 1994. PMID: 7523480 Clinical Trial.
-
Interpretations of five monoclonal immunoassays of lutropin and follitropin: effects of normalization with WHO standard.Clin Chem. 1991 Mar;37(3):415-21. Clin Chem. 1991. PMID: 1900742
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources