Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation
- PMID: 30165898
- PMCID: PMC6117945
- DOI: 10.1186/s12938-018-0549-6
Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation
Abstract
Background: Superiority of noninvasive tripolar concentric ring electrodes over conventional disc electrodes in accuracy of surface Laplacian estimation has been demonstrated in a range of electrophysiological measurement applications. Recently, a general approach to Laplacian estimation for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method has been proposed and used to introduce novel multipolar and variable inter-ring distances electrode configurations. While only linearly increasing and linearly decreasing inter-ring distances have been considered previously, this paper defines and solves the general inter-ring distances optimization problem for the (4n + 1)-point method.
Results: General inter-ring distances optimization problem is solved for tripolar (n = 2) and quadripolar (n = 3) concentric ring electrode configurations through minimizing the truncation error of Laplacian estimation. For tripolar configuration with middle ring radius αr and outer ring radius r the optimal range of values for α was determined to be 0 < α ≤ 0.22 while for quadripolar configuration with an additional middle ring with radius βr the optimal range of values for α and β was determined by inequalities 0 < α < β < 1 and αβ ≤ 0.21. Finite element method modeling and full factorial analysis of variance were used to confirm statistical significance of Laplacian estimation accuracy improvement due to optimization of inter-ring distances (p < 0.0001).
Conclusions: Obtained results suggest the potential of using optimization of inter-ring distances to improve the accuracy of surface Laplacian estimation via concentric ring electrodes. Identical approach can be applied to solving corresponding inter-ring distances optimization problems for electrode configurations with higher numbers of concentric rings. Solutions of the proposed inter-ring distances optimization problem define the class of the optimized inter-ring distances electrode designs. These designs may result in improved noninvasive sensors for measurement systems that use concentric ring electrodes to acquire electrical signals such as from the brain, intestines, heart or uterus for diagnostic purposes.
Keywords: Concentric ring electrodes; Electroencephalography; Electrophysiology; Finite element method; Inter-ring distances; Laplacian; Modeling; Optimization; Wearable sensors.
Figures
![Fig. 1](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig1_HTML.gif)
![Fig. 2](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig2_HTML.gif)
![Fig. 3](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig3_HTML.gif)
![Fig. 4](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig4_HTML.gif)
![Fig. 5](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig5_HTML.gif)
![Fig. 6](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig6_HTML.gif)
![Fig. 7](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig7_HTML.gif)
![Fig. 8](https://cdn.statically.io/img/www.ncbi.nlm.nih.gov/pmc/articles/instance/6117945/bin/12938_2018_549_Fig8_HTML.gif)
Similar articles
-
Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.Sensors (Basel). 2016 Jun 10;16(6):858. doi: 10.3390/s16060858. Sensors (Basel). 2016. PMID: 27294933 Free PMC article.
-
Finite element method modeling to assess Laplacian estimates via novel variable inter-ring distances concentric ring electrodes.Annu Int Conf IEEE Eng Med Biol Soc. 2016 Aug;2016:2054-2057. doi: 10.1109/EMBC.2016.7591131. Annu Int Conf IEEE Eng Med Biol Soc. 2016. PMID: 28268734
-
Analytic assessment of Laplacian estimates via novel variable interring distances concentric ring electrodes.Annu Int Conf IEEE Eng Med Biol Soc. 2016 Aug;2016:2058-2062. doi: 10.1109/EMBC.2016.7591132. Annu Int Conf IEEE Eng Med Biol Soc. 2016. PMID: 28268735
-
Finite element method modeling to confirm the results of comprehensive optimization of the tripolar concentric ring electrode based on its finite dimensions model.Annu Int Conf IEEE Eng Med Biol Soc. 2021 Nov;2021:7244-7247. doi: 10.1109/EMBC46164.2021.9629784. Annu Int Conf IEEE Eng Med Biol Soc. 2021. PMID: 34892770
-
Laplacian electrocardiography.Crit Rev Biomed Eng. 1999;27(3-5):285-338. Crit Rev Biomed Eng. 1999. PMID: 10864282 Review.
Cited by
-
Real-time noise cancellation with deep learning.PLoS One. 2022 Nov 21;17(11):e0277974. doi: 10.1371/journal.pone.0277974. eCollection 2022. PLoS One. 2022. PMID: 36409690 Free PMC article.
-
Comprehensive Optimization of the Tripolar Concentric Ring Electrode Based on Its Finite Dimensions Model and Confirmed by Finite Element Method Modeling.Sensors (Basel). 2021 Aug 31;21(17):5881. doi: 10.3390/s21175881. Sensors (Basel). 2021. PMID: 34502772 Free PMC article.
-
Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes.Sensors (Basel). 2019 Aug 31;19(17):3780. doi: 10.3390/s19173780. Sensors (Basel). 2019. PMID: 31480426 Free PMC article.
References
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources