Sensor integration of multiple tripolar concentric ring electrodes improves pentylenetetrazole-induced seizure onset detection in rats
- PMID: 23367089
- DOI: 10.1109/EMBC.2012.6347154
Sensor integration of multiple tripolar concentric ring electrodes improves pentylenetetrazole-induced seizure onset detection in rats
Abstract
As epilepsy affects approximately one percent of the world population, electrical stimulation of the brain has recently shown potential for additive seizure control therapy. Previously, we applied noninvasive transcranial focal stimulation via tripolar concentric ring electrodes on the scalp of rats after inducing seizures with pentylenetetrazole. We developed a system to detect seizures and automatically trigger the stimulation and evaluated the system on the electrographic activity from rats. In this preliminary study we propose and validate a novel seizure onset detection algorithm based on exponentially embedded family. Unlike the previously proposed approach it integrates the data from multiple electrodes allowing an improvement of the detector performance.
Similar articles
-
Feasibility of recording high frequency oscillations with tripolar concentric ring electrodes during pentylenetetrazole-induced seizures in rats.Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:4599-602. doi: 10.1109/EMBC.2012.6346991. Annu Int Conf IEEE Eng Med Biol Soc. 2012. PMID: 23366952
-
Toward a noninvasive automatic seizure control system in rats with transcranial focal stimulations via tripolar concentric ring electrodes.IEEE Trans Neural Syst Rehabil Eng. 2012 Jul;20(4):422-31. doi: 10.1109/TNSRE.2012.2197865. IEEE Trans Neural Syst Rehabil Eng. 2012. PMID: 22772373 Free PMC article.
-
Multiple sensor integration for seizure onset detection in human patients comparing conventional disc versus novel tripolar concentric ring electrodes.Annu Int Conf IEEE Eng Med Biol Soc. 2013;2013:17-20. doi: 10.1109/EMBC.2013.6609426. Annu Int Conf IEEE Eng Med Biol Soc. 2013. PMID: 24109613
-
Possible therapeutic effects of transcutaneous electrical stimulation via concentric ring electrodes.Epilepsia. 2010 Jul;51 Suppl 3:85-7. doi: 10.1111/j.1528-1167.2010.02617.x. Epilepsia. 2010. PMID: 20618408 Review.
-
Seizure detection using scalp-EEG.Epilepsia. 2018 Jun;59 Suppl 1:14-22. doi: 10.1111/epi.14052. Epilepsia. 2018. PMID: 29873826 Review.
Cited by
-
Summary of over Fifty Years with Brain-Computer Interfaces-A Review.Brain Sci. 2021 Jan 3;11(1):43. doi: 10.3390/brainsci11010043. Brain Sci. 2021. PMID: 33401571 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Medical
Research Materials