-
Projected background and sensitivity of AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (81 additional authors not shown)
Abstract:
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located ap…
▽ More
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
-
Motile bacteria crossing liquid-liquid interfaces
Authors:
Jiyong Cheon,
Joowang Son,
Sungbin Lim,
Yundon Jeong,
Jung-Hoon Park,
Robert J. Mitchell,
Jaeup U. Kim,
Joonwoo Jeong
Abstract:
Real-life bacteria often swim in complex fluids, but our understanding of the interactions between bacteria and complex surroundings is still evolving. In this work, rod-like \textit{Bacillus subtilis} swims in a quasi-2D environment with aqueous liquid-liquid interfaces, i.e., the isotropic-nematic coexistence phase of an aqueous chromonic liquid crystal. Focusing on the bacteria motion near and…
▽ More
Real-life bacteria often swim in complex fluids, but our understanding of the interactions between bacteria and complex surroundings is still evolving. In this work, rod-like \textit{Bacillus subtilis} swims in a quasi-2D environment with aqueous liquid-liquid interfaces, i.e., the isotropic-nematic coexistence phase of an aqueous chromonic liquid crystal. Focusing on the bacteria motion near and at the liquid-liquid interfaces, we collect and quantify bacterial trajectories ranging across the isotropic to the nematic phase. Despite its small magnitude, the interfacial tension of the order of 10 $\mathrm{μN/m}$ at the isotropic-nematic interface justifies our observations that bacteria swimming more perpendicular to the interface have a higher probability of crossing the interface. Our force-balance model, considering the interfacial tension, further predicts how the length and speed of the bacteria affect their crossing behaviors. We also find, as soon as the bacteria cross the interface and enter the nematic phase, they wiggle less, but faster, and that this occurs as the flagellar bundles aggregate within the nematic phase.
△ Less
Submitted 12 April, 2024; v1 submitted 7 February, 2024;
originally announced February 2024.
-
Performance of an ultra-pure NaI(Tl) detector produced by an indigenously-developed purification method and crystal growth for the COSINE-200 experiment
Authors:
Hyun Seok Lee,
Byung Ju Park,
Jae Jin Choi,
Olga Gileva,
Chang Hyon Ha,
Alain Iltis,
Eun Ju Jeon,
Dae Yeon Kim,
Kyung Won Kim,
Sung Hyun Kim,
Sun Kee Kim,
Yeong Duk Kim,
Young Ju Ko,
Cheol Ho Lee,
Hyun Su Lee,
In Soo Lee,
Moo Hyun Lee,
Se Jin Ra,
Ju Kyung Son,
Keon Ah Shin
Abstract:
The COSINE-100 experiment has been operating with 106 kg of low-background NaI(Tl) detectors to test the results from the DAMA/LIBRA experiment, which claims to have observed dark matter. However, since the background of the NaI(Tl) crystals used in the COSINE-100 experiment is 2-3 times higher than that in the DAMA detectors, no conclusion regarding the claimed observation from the DAMA/LIBRA exp…
▽ More
The COSINE-100 experiment has been operating with 106 kg of low-background NaI(Tl) detectors to test the results from the DAMA/LIBRA experiment, which claims to have observed dark matter. However, since the background of the NaI(Tl) crystals used in the COSINE-100 experiment is 2-3 times higher than that in the DAMA detectors, no conclusion regarding the claimed observation from the DAMA/LIBRA experiment could be reached. Therefore, we plan to upgrade the current COSINE-100 experiment to the next phase, COSINE-200, by using ultra-low background NaI(Tl) detectors. The basic principle was already proved with the commercially available Astro-grade NaI powder from Sigma-Aldrich company. However, we have developed a mass production process of ultra-pure NaI powder at the Center for Underground Physics (CUP) of the Institute for Basic Science (IBS), Korea, using the direct purification of the raw NaI powder. We plan to produce more than 1,000 kg of ultra-pure powder for the COSINE200 experiment. With our crystal grower installed at CUP, we have successfully grown a low-background crystal using our purification technique for the NaI powder. We have assembled a low-background NaI(Tl) detector. In this article, we report the performance of this ultra-pure NaI(Tl) crystal detector produced at IBS, Korea.
△ Less
Submitted 12 January, 2023;
originally announced January 2023.
-
Ion acceleration with few cycle relativistic laser pulses from foil targets
Authors:
Sargis Ter-Avetisyan,
Parvin Varmazyar,
Prashant K. Singh,
Joon-Gon Son,
Miklos Fule,
Valery Yu. Bychenkov,
Balazs Farkas,
Kwinten Nelissen,
Sudipta Mondal,
Daniel Papp,
Adam Borzsonyi,
Janos Csontos,
Zsolt Lecz,
Tamas Somoskoi,
Laszlo Toth,
Szabolcs Toth,
Velyhan Andriy,
Daniele Margarone,
Ales Necas,
Toshiki Tajima,
Gerard Mourou,
Gabor Szabo,
Karoly Osvay
Abstract:
Ion acceleration resulting from the interaction of 11 fs laser pulses of ~35 mJ energy with ultrahigh contrast (<10^-10), and 10^19 W/cm^2 peak intensity with foil targets made of various materials and thicknesses at normal (0-degree) and 45-degree laser incidence is investigated. The maximum energy of the protons accelerated from both the rear and front sides of the target was above 1 MeV. A conv…
▽ More
Ion acceleration resulting from the interaction of 11 fs laser pulses of ~35 mJ energy with ultrahigh contrast (<10^-10), and 10^19 W/cm^2 peak intensity with foil targets made of various materials and thicknesses at normal (0-degree) and 45-degree laser incidence is investigated. The maximum energy of the protons accelerated from both the rear and front sides of the target was above 1 MeV. A conversion efficiency from laser pulse energy to proton beam is estimated to be as high as ~1.4 % at 45-degree laser incidence using a 51 nm-thick Al target. The excellent laser contrast indicates the predominance of vacuum heating via the Brunels effect as an absorption mechanism involving a tiny pre-plasma of natural origin due to the Gaussian temporal laser pulse shape. Experimental results are in reasonable agreement with theoretical estimates where proton acceleration from the target rear into the forward direction is well explained by a TNSA-like mechanism, while proton acceleration from the target front into the backward direction can be explained by the formation of a charged cavity in a tiny pre-plasma. The exploding Coulomb field from the charged cavity also serves as a source for forward-accelerated ions at thick targets.
△ Less
Submitted 1 December, 2022;
originally announced December 2022.
-
Input optics systems of the KAGRA detector during O3GK
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
Z. Cao,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
C-I. Chiang,
H. Chu,
Y-K. Chu,
S. Eguchi
, et al. (228 additional authors not shown)
Abstract:
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensit…
▽ More
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.
△ Less
Submitted 12 October, 2022;
originally announced October 2022.
-
Preregistered protocol for: Articulatory changes in speech following treatment for oral or oropharyngeal cancer: a systematic review
Authors:
Thomas B. Tienkamp,
Teja Rebernik,
Defne Abur,
Rob J. J. H. van Son,
Sebastiaan A. H. J. de Visscher,
Max J. H. Witjes,
Martijn Wieling
Abstract:
This document outlines a PROSPERO pre-registered protocol for a systematic review regarding articulatory changes in speech following oral or orophayrngeal cancer treatment. Treatment of tumours in the oral cavity may result in physiological changes that could lead to articulatory difficulties. The tongue becomes less mobile due to scar tissue and/or potential (postoperative) radiation therapy. Mor…
▽ More
This document outlines a PROSPERO pre-registered protocol for a systematic review regarding articulatory changes in speech following oral or orophayrngeal cancer treatment. Treatment of tumours in the oral cavity may result in physiological changes that could lead to articulatory difficulties. The tongue becomes less mobile due to scar tissue and/or potential (postoperative) radiation therapy. Moreover, tissue loss may create a bypass for airflow or limit constriction possibilities. In order to gain a better understanding of the nature of the speech problems, information regarding the movement of the articulators is needed since perceptual or acoustic information provide only indirect evidence of articulatory changes. Therefore, this systematic review will review studies that directly measured the articulatory movements of the tongue, jaw, and lips following treatment for oral or oropharyngeal cancer.
△ Less
Submitted 14 September, 2022;
originally announced September 2022.
-
Identifying multichannel coherent couplings and causal relationships in gravitational wave detectors
Authors:
Piljong Jung,
Sang Hoon Oh,
Young-Min Kim,
Edwin J. Son,
Takaaki Yokozawa,
Tatsuki Washimi,
John J. Oh
Abstract:
The gravitational-wave detector is a complex and sensitive collection of advanced instruments that are impacted not only by mechanical/electronics systems but also by the surrounding environment. Hence, it is of great importance to classify and mitigate noises to detect gravitational-wave signals by using information from many auxiliary channels related to such devices and surroundings. This impro…
▽ More
The gravitational-wave detector is a complex and sensitive collection of advanced instruments that are impacted not only by mechanical/electronics systems but also by the surrounding environment. Hence, it is of great importance to classify and mitigate noises to detect gravitational-wave signals by using information from many auxiliary channels related to such devices and surroundings. This improves the signal-to-noise ratio and reduces false alarms from coincident loud events. For this reason, it is essential for identifying coherent relationships between complex channels. This study presents a way of identifying (non-) linear couplings between associated channels by using the method of correlation coefficients. And we show that the method can be applied to practical problems in the gravitational-wave detector, such as noises by lightning strokes, air compressors vibrations, and noises caused by wind effects.
△ Less
Submitted 18 July, 2022; v1 submitted 1 April, 2022;
originally announced April 2022.
-
Glass-like Electronics in Vanadium Dioxide
Authors:
Mohammad Samizadeh Nikoo,
Reza Soleimanzadeh,
Anna Krammer,
Yunkyu Park,
Junwoo Son,
Andreas Schueler,
Philip J. W. Moll,
Elison Matioli
Abstract:
Functional materials can offer new paradigms for miniaturized and energy-efficient electronics, providing a complementary or even alternative platform to metal-oxide-semiconductors. Here we report on electronically accessible long-lived structural states in Vanadium Dioxide that can offer a scheme for data storage and processing. We show that such states can be electrically manipulated and tracked…
▽ More
Functional materials can offer new paradigms for miniaturized and energy-efficient electronics, providing a complementary or even alternative platform to metal-oxide-semiconductors. Here we report on electronically accessible long-lived structural states in Vanadium Dioxide that can offer a scheme for data storage and processing. We show that such states can be electrically manipulated and tracked beyond 10,000 seconds after excitation, exhibiting similar features of glasses, which are beyond the classic metastability in Mott systems. Glass-like electronics can potentially overcome some of the fundamental limitations in conventional metal-oxide-semiconductor electronics, and open avenues for neuromorphic computation and multi-level memories.
△ Less
Submitted 4 November, 2021;
originally announced November 2021.
-
Alpha backgrounds in the AMoRE-Pilot experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
S. H. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. Gezhaev,
V. D. Grigoryeva,
V. Gurentsov,
D. H. Ha,
C. Ha,
E. J. Ha,
I. Hahn,
E. J. Jeon
, et al. (81 additional authors not shown)
Abstract:
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit…
▽ More
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.
△ Less
Submitted 5 December, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Optimizing Parameters of Information-Theoretic Correlation Measurement for Multi-Channel Time-Series Datasets in Gravitational Wave Detectors
Authors:
Piljong Jung,
Sang Hoon Oh,
Young-Min Kim,
Edwin J. Son,
John J. Oh
Abstract:
Data analysis in modern science using extensive experimental and observational facilities, such as a gravitational wave detector, is essential in the search for novel scientific discoveries. Accordingly, various techniques and mathematical principles have been designed and developed to date. A recently proposed approximate correlation method based on the information theory is widely adopted in sci…
▽ More
Data analysis in modern science using extensive experimental and observational facilities, such as a gravitational wave detector, is essential in the search for novel scientific discoveries. Accordingly, various techniques and mathematical principles have been designed and developed to date. A recently proposed approximate correlation method based on the information theory is widely adopted in science and engineering. Although the maximal information coefficient (MIC) method remains in the phase of improving its algorithm, it is particularly beneficial in identifying the correlations of multiple noise sources in gravitational-wave detectors including non-linear effects. This study investigates various prospects for determining MIC parameters to improve the reliability of handling multi-channel time-series data, reduce high computing costs, and propose a novel method of determining optimized parameter sets for identifying noise correlations in gravitational wave data.
△ Less
Submitted 13 June, 2022; v1 submitted 7 July, 2021;
originally announced July 2021.
-
Growth and development of pure Li2MoO4 crystals for rare event experiment at CUP
Authors:
J. K. Son,
J. S. Choe,
O. Gileva,
I. S. Hahn,
W. G. Kang,
D. Y. Kim,
G. W. Kim,
H. J. Kim,
Y. D. Kim,
C. H. Lee,
E. K. Lee,
M. H. Lee,
D. S. Leonard,
H. K. Park,
S. Y. Park,
S. J. Ra,
K. A. Shin
Abstract:
The Center for Underground Physics (CUP) of the Institute for Basic Science (IBS) is searching for the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) of 100Mo in the molybdate crystals of the AMoRE experiment. The experiment requires pure scintillation crystals to minimize internal backgrounds that can affect the 0ν\b{eta}\b{eta} signal. For the last few years, we have been growing and studying…
▽ More
The Center for Underground Physics (CUP) of the Institute for Basic Science (IBS) is searching for the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) of 100Mo in the molybdate crystals of the AMoRE experiment. The experiment requires pure scintillation crystals to minimize internal backgrounds that can affect the 0ν\b{eta}\b{eta} signal. For the last few years, we have been growing and studying Li2MoO4 crystals in a clean-environment facility to minimize external contamination during the crystal growth. Before growing Li2100MoO4 crystal, we have studied Li2natMoO4 crystal growth by a conventional Czochralski (CZ) grower. We grew a few different kinds of Li2natMO4 crystals using different raw materials in a campaign to minimize impurities. We prepared the fused Al2O3 refractories for the growth of ingots. Purities of the grown crystals were measured with high purity germanium detectors and by inductively coupled plasma mass spectrometry. The results show that the Li2MoO4 crystal has purity levels suitable for rare-event experiments. In this study, we present the growth of Li2MoO4 crystals at CUP and their purities.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Overview of KAGRA: Detector design and construction history
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. -W. Bae,
Y. -B. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. -L. Chan,
C. -S. Chen,
K. -H. Chen,
Y. -R. Chen,
H. -Y. Chu,
Y-K. Chu,
S. Eguchi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (175 additional authors not shown)
Abstract:
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA…
▽ More
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.
△ Less
Submitted 2 July, 2020; v1 submitted 12 May, 2020;
originally announced May 2020.
-
Fast magneto-ionic switching of interface anisotropy using yttria-stabilized zirconia gate oxide
Authors:
Ki-Young Lee,
Sujin Jo,
Aik Jun Tan,
Mantao Huang,
Dongwon Choi,
Jung Hoon Park,
Ho-Il Ji,
Ji-Won Son,
Joonyeon Chang,
Geoffrey S. D. Beach,
Seonghoon Woo
Abstract:
Voltage control of interfacial magnetism has been greatly highlighted in spintronics research for many years, as it might enable ultra-low power technologies. Among few suggested approaches, magneto-ionic control of magnetism has demonstrated large modulation of magnetic anisotropy. Moreover, the recent demonstration of magneto-ionic devices using hydrogen ions presented relatively fast magnetizat…
▽ More
Voltage control of interfacial magnetism has been greatly highlighted in spintronics research for many years, as it might enable ultra-low power technologies. Among few suggested approaches, magneto-ionic control of magnetism has demonstrated large modulation of magnetic anisotropy. Moreover, the recent demonstration of magneto-ionic devices using hydrogen ions presented relatively fast magnetization toggle switching, tsw ~ 100 ms, at room temperature. However, the operation speed may need to be significantly improved to be used for modern electronic devices. Here, we demonstrate that the speed of proton-induced magnetization toggle switching largely depends on proton-conducting oxides. We achieve ~1 ms reliable (> 103 cycles) switching using yttria-stabilized zirconia (YSZ), which is ~ 100 times faster than the state-of-the-art magneto-ionic devices reported to date at room temperature. Our results suggest further engineering of the proton-conducting materials could bring substantial improvement that may enable new low-power computing scheme based on magneto-ionics.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
Development of ultra-pure NaI(Tl) detectors for the COSINE-200 experiment
Authors:
B. J. Park,
J. J. Choe,
J. S. Choi,
O. Gileva,
C. Ha,
A. Iltis,
E. J. Jeon,
D. Y. Kim,
K. W. Kim,
S. K. Kim,
Y. D. Kim,
Y. J. Ko,
C. H. Lee,
H. S. Lee,
I. S. Lee,
M. H. Lee,
S. H. Lee,
S. J. Ra,
J. K. Son,
K. A. Shin
Abstract:
The annual modulation signal observed by the DAMA experiment is a long-standing question in the community of dark matter direct detection. This necessitates an independent verification of its existence using the same detection technique. The COSINE-100 experiment has been operating with 106~kg of low-background NaI(Tl) detectors providing interesting checks on the DAMA signal. However, due to high…
▽ More
The annual modulation signal observed by the DAMA experiment is a long-standing question in the community of dark matter direct detection. This necessitates an independent verification of its existence using the same detection technique. The COSINE-100 experiment has been operating with 106~kg of low-background NaI(Tl) detectors providing interesting checks on the DAMA signal. However, due to higher backgrounds in the NaI(Tl) crystals used in COSINE-100 relative to those used for DAMA, it was difficult to reach final conclusions. Since the start of COSINE-100 data taking in 2016, we also have initiated a program to develop ultra-pure NaI(Tl) crystals for COSINE-200, the next phase of the experiment. The program includes efforts of raw powder purification, ultra-pure NaI(Tl) crystal growth, and detector assembly techniques. After extensive research and development of NaI(Tl) crystal growth, we have successfully grown a few small-size (0.61$-$0.78 kg) thallium-doped crystals with high radio-purity. A high light yield has been achieved by improvements of our detector assembly technique. Here we report the ultra-pure NaI(Tl) detector developments at the Institute for Basic Science, Korea. The technique developed here will be applied to the production of NaI(Tl) detectors for the COSINE-200 experiment.
△ Less
Submitted 31 August, 2020; v1 submitted 13 April, 2020;
originally announced April 2020.
-
Optimizing hospital distribution across districts for reducing tuberculosis fatalities
Authors:
Mi Jin Lee,
Kanghun Kim,
Junik Son,
Deok-Sun Lee
Abstract:
The spatial distributions of diverse facilities are often understood in terms of the optimization of the commute distance or the economic profit. Incorporating more general objective functions into such optimization framework may be useful, helping the policy decisions to meet various social and economic demands. As an example, we consider how hospitals should be distributed to minimize the total…
▽ More
The spatial distributions of diverse facilities are often understood in terms of the optimization of the commute distance or the economic profit. Incorporating more general objective functions into such optimization framework may be useful, helping the policy decisions to meet various social and economic demands. As an example, we consider how hospitals should be distributed to minimize the total fatalities of tuberculosis (TB). The empirical data of Korea shows that the fatality rate of TB in a district decreases with the areal density of hospitals, implying their correlation and the possibility of reducing the nationwide fatalities by adjusting the hospital distribution across districts. Approximating the fatality rate by the probability of a patient not to visit a hospital in her/his residential district for the duration period of TB and evaluating the latter probability in the random-walk framework, we obtain the fatality rate as an exponential function of the hospital density with a characteristic constant related to each district's effective lattice constant estimable empirically. This leads us to the optimal hospital distribution which finds the hospital density in a district to be a logarithmic function of the rescaled patient density. The total fatalities is reduced by 13\% with this optimum. The current hospital density deviates from the optimized one in different manners from district to district, which is analyzed in the proposed model framework. The assumptions and limitations of our study are also discussed.
△ Less
Submitted 26 February, 2020;
originally announced February 2020.
-
Reflection anisotropy experiments to study non-equilibrium dynamics of electronic nematicity
Authors:
Inho Kwak,
Jaeseok Son,
Bumjoo Lee,
Thomas Wolf,
Changhee Sohn,
Tae Won Noh,
K. W. Kim
Abstract:
Electronic nematicity have attracted a great deal of interest in the unconventional superconductivity research. We present an experimental method to investigate reflectivity anisotropy by the electronic nematicity and its non-equilibrium dynamics. Our experimental results on Ba(Fe$_{0.955}$Co$_{0.045}$)$_{2}$As$_{2}$ single crystal clearly feature the broken four-fold symmetry along directions par…
▽ More
Electronic nematicity have attracted a great deal of interest in the unconventional superconductivity research. We present an experimental method to investigate reflectivity anisotropy by the electronic nematicity and its non-equilibrium dynamics. Our experimental results on Ba(Fe$_{0.955}$Co$_{0.045}$)$_{2}$As$_{2}$ single crystal clearly feature the broken four-fold symmetry along directions parallel to Fe-Fe bonding. Numerical simulations using WVASE from Woollam Co. demonstrate that our method is highly reliable under various experimental conditions. Finally, we perform time-resolved reflectivity anisotropy measurement confirming that photo-excitation by 1.55 eV photons suppresses the reflectivity anisotropy due to nematic order.
△ Less
Submitted 28 November, 2019;
originally announced November 2019.
-
An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
T. Akutsu,
M. Ando,
K. Arai,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu,
K. Doi,
S. Eguchi,
Y. Enomoto
, et al. (181 additional authors not shown)
Abstract:
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, wh…
▽ More
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
△ Less
Submitted 28 November, 2019; v1 submitted 2 October, 2019;
originally announced October 2019.
-
First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
D. M. Chernyak,
J. S. Choe,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. D. Grigoryeva,
V. I. Gurentsov,
O. Gylova,
C. Ha,
D. H. Ha
, et al. (84 additional authors not shown)
Abstract:
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-de…
▽ More
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.
△ Less
Submitted 7 May, 2019; v1 submitted 22 March, 2019;
originally announced March 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Vibration isolation system with a compact damping system for power recycling mirrors of KAGRA
Authors:
Y. Akiyama,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
V. Dattilo,
K. Doi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (149 additional authors not shown)
Abstract:
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main st…
▽ More
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient damping performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the damping performance, and also on estimated residual displacement of the optics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
Stochastic Modelling and Dynamic Analysis of Cardiovascular System with Rotary Left Ventricular Assist Devices
Authors:
Jeongeun Son,
Dongping Du,
Yuncheng Du
Abstract:
The left ventricular assist device (LVAD) has been used for end-stage heart failure patients as a therapeutic option. The aortic valve plays a critical role in heart failure and its treatment with LVAD. The cardiovascular-LVAD model is often used to investigate the physiological demands required by patients and predict the hemodynamic of the native heart supported with a LVAD. As a bridge to recov…
▽ More
The left ventricular assist device (LVAD) has been used for end-stage heart failure patients as a therapeutic option. The aortic valve plays a critical role in heart failure and its treatment with LVAD. The cardiovascular-LVAD model is often used to investigate the physiological demands required by patients and predict the hemodynamic of the native heart supported with a LVAD. As a bridge to recovery treatment, it is important to maintain appropriate and active dynamics of the aortic valve and the cardiac output of the native heart, which requires that the LVAD pump must be adjusted so that a proper balance between the blood contributed through the aortic valve and the pump is maintained. In this paper, our objective is to identify a critical value of the pump power to ensure that the LVAD pump does not take over the pumping function in the cardiovascular-pump system and share the ejected blood with left ventricle to help the heart to recover. In addition, hemodynamic often involves variability due to patients heterogeneity and the stochastic nature of cardiovascular system. The variability poses significant challenges to understand dynamic behaviors of the aortic valve and cardiac output. A generalized polynomial chaos (gPC) expansion is used in this work to develop a stochastic cardiovascular-pump model for efficient uncertainty propagation, from which it is possible to rapidly calculate the variance in the aortic valve opening duration and the cardiac output in the presence of variability. The simulation results show that the gPC based cardiovascular-pump model is a reliable platform that can provide useful information to understand the effect of LVAD pump on the hemodynamic of the heart.
△ Less
Submitted 17 December, 2018;
originally announced December 2018.
-
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto
, et al. (169 additional authors not shown)
Abstract:
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Tel…
▽ More
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.
-
Generating Event Triggers Based on Hilbert-Huang Transform and Its Application to Gravitational-Wave Data
Authors:
Edwin J. Son,
Whansun Kim,
Young-Min Kim,
Jessica McIver,
John J. Oh,
Sang Hoon Oh
Abstract:
We present a new event trigger generator based on the Hilbert-Huang transform, named EtaGen ($η$Gen). It decomposes a time-series data into several adaptive modes without imposing a priori bases on the data. The adaptive modes are used to find transients (excesses) in the background noises. A clustering algorithm is used to gather excesses corresponding to a single event and to reconstruct its wav…
▽ More
We present a new event trigger generator based on the Hilbert-Huang transform, named EtaGen ($η$Gen). It decomposes a time-series data into several adaptive modes without imposing a priori bases on the data. The adaptive modes are used to find transients (excesses) in the background noises. A clustering algorithm is used to gather excesses corresponding to a single event and to reconstruct its waveform. The performance of EtaGen is evaluated by how many injections in the LIGO simulated data are found. EtaGen is viable as an event trigger generator when compared directly with the performance of Omicron, which is currently the best event trigger generator used in the LIGO Scientific Collaboration and Virgo Collaboration.
△ Less
Submitted 17 October, 2018;
originally announced October 2018.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
Linear frequency conversion via sudden merging of resonances in time-variant metasurfaces
Authors:
Kanghee Lee,
Jaehyeon Son,
Jagang Park,
Byungsoo Kang,
Wonju Jeon,
Fabian Rotermund,
Bumki Min
Abstract:
Energy conversion in a physical system requires time-translation invariance breaking according to Noether's theorem. Closely associated with this symmetry-conservation relation, the frequencies of electromagnetic waves are found to be converted as the waves propagate through a temporally varying medium. Thus, effective temporal control of the medium, be it artificial or natural, through which the…
▽ More
Energy conversion in a physical system requires time-translation invariance breaking according to Noether's theorem. Closely associated with this symmetry-conservation relation, the frequencies of electromagnetic waves are found to be converted as the waves propagate through a temporally varying medium. Thus, effective temporal control of the medium, be it artificial or natural, through which the waves are propagating, lies at the heart of linear optical frequency conversion. Here, we propose rapidly time-variant metasurfaces as a frequency-conversion platform and experimentally demonstrate their efficacy at THz frequencies. The proposed metasurface is designed for the sudden merging of two distinct resonances into a single resonance upon ultrafast optical excitation. From this spectrally-engineered temporal boundary onward, the merged-resonance frequency component is radiated. In addition, temporal coherence of the two original resonating modes with respect to the abrupt temporal boundary is found to be strongly related to the amount of frequency conversion as well as the phase of the converted wave. Due to their design flexibility, time-variant metasurfaces may become on-demand frequency synthesizers for various frequency ranges.
△ Less
Submitted 2 June, 2017;
originally announced June 2017.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Ternary and senary representations using DNA double-crossover tiles
Authors:
Byeonghoon Kim,
Soojin Jo,
Junyoung Son,
Junghoon Kim,
Si Un Hwang,
Sreekantha Reddy Dugasani,
Min Hyeok Kim,
Byung-Dong Kim,
Iksoo Chang,
Wing Kam Liu,
Moon Ki Kim,
Sung Ha Park
Abstract:
The information capacity of double-crossover (DX) tiles was successfully increased beyond a binary representation to higher base representations. By controlling the length and the position of DNA hairpins on the DX tile, ternary and senary (base-3 and base-6) digit representations were realized and verified by atomic force microscopy (AFM). Also, normal mode analysis (NMA) was carried out to study…
▽ More
The information capacity of double-crossover (DX) tiles was successfully increased beyond a binary representation to higher base representations. By controlling the length and the position of DNA hairpins on the DX tile, ternary and senary (base-3 and base-6) digit representations were realized and verified by atomic force microscopy (AFM). Also, normal mode analysis (NMA) was carried out to study the mechanical characteristics of each structure.
△ Less
Submitted 6 January, 2016;
originally announced January 2016.
-
Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment
Authors:
V. Alenkov,
P. Aryal,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun D. M. Chernyak,
J. Choi,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. I. Gurentsov,
D. H Ha,
I. S. Hahn,
J. H. Jang,
E. J. Jeon,
H. S. Jo
, et al. (65 additional authors not shown)
Abstract:
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillati…
▽ More
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.
△ Less
Submitted 18 December, 2015;
originally announced December 2015.
-
Long-lived neutral-kaon flux measurement for the KOTO experiment
Authors:
T. Masuda,
J. K. Ahn,
S. Banno,
M. Campbell,
J. Comfort,
Y. T. Duh,
T. Hineno,
Y. B. Hsiung,
T. Inagaki,
E. Iwai,
N. Kawasaki,
E. J. Kim,
Y. J. Kim,
J. W. Ko,
T. K. Komatsubara,
A. S. Kurilin,
G. H. Lee,
J. W. Lee,
S. K. Lee,
G. Y. Lim,
J. Ma,
D. MacFarland,
Y. Maeda,
T. Matsumura,
R. Murayama
, et al. (32 additional authors not shown)
Abstract:
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$,…
▽ More
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.
△ Less
Submitted 7 January, 2016; v1 submitted 11 September, 2015;
originally announced September 2015.
-
Feasibility study of heavy ion beams and compound target materials for muon production
Authors:
Jaebum Son,
Ju Hahn Lee,
Gi Dong Kim,
Yong Kyun Kim
Abstract:
We have investigated the feasibility of using compound materials as target for muon production by virtue of simulations using a GEANT4 toolkit. A graphite and two thermostable compound materials, beryllium oxide (BeO) and boron carbide (B4C) were considered as muon production targets and their muon production rates for 600-MeV proton beam were calculated and compared. For thermal analysis, total h…
▽ More
We have investigated the feasibility of using compound materials as target for muon production by virtue of simulations using a GEANT4 toolkit. A graphite and two thermostable compound materials, beryllium oxide (BeO) and boron carbide (B4C) were considered as muon production targets and their muon production rates for 600-MeV proton beam were calculated and compared. For thermal analysis, total heat deposited on the targets by the proton beams and the secondary particles was calculated with a MCNPX code, and then the temperature distribution of target was derived from the calculated heat by using an ANSYS code with consideration for heat transfer mechanisms, such as thermal conduction and thermal radiation. In addition, we have investigated whether the heavy ion beams can be utilized for muon production. For various beam species such as 3He2, 4He, 7Li, 10B and 12C, their muon production rates were calculated and compared with that obtained for a proton beam.
△ Less
Submitted 14 July, 2015;
originally announced July 2015.
-
Highly sensitive and selective sugar detection by terahertz nano-antennas
Authors:
Dong-Kyu Lee,
Ji-Hun Kang,
Jun-Seok Lee,
Hyo-Seok Kim,
Chulki Kim,
Jae Hun Kim,
Taikjin Lee,
Joo-Hiuk Son,
Q-Han Park,
Minah Seo
Abstract:
Molecular recognition and discrimination of carbohydrates are important because carbohydrates perform essential roles in most living organisms for energy metabolism and cell-to-cell communication. Nevertheless, it is difficult to identify or distinguish various carbohydrate molecules owing to the lack of a significant distinction in the physical or chemical characteristics. Although there has been…
▽ More
Molecular recognition and discrimination of carbohydrates are important because carbohydrates perform essential roles in most living organisms for energy metabolism and cell-to-cell communication. Nevertheless, it is difficult to identify or distinguish various carbohydrate molecules owing to the lack of a significant distinction in the physical or chemical characteristics. Although there has been considerable effort to develop a sensing platform for individual carbohydrates selectively using chemical receptors or an ensemble array, their detection and discrimination limits have been as high in the millimolar concentration range. Here we show a highly sensitive and selective detection method for the discrimination of carbohydrate molecules using nano-slot-antenna array-based sensing chips which operate in the terahertz frequency range. This THz metamaterial sensing tool recognizes various types of carbohydrate molecules over a wide range of molecular concentrations. Strongly localized and enhanced terahertz transmission by nano-antennas can effectively increase the molecular absorption cross sections, thereby enabling the detection of these molecules even at low concentrations. We verified the performance of nano-antenna sensing chip by both THz spectra and images of transmittance. Screening and identification of various carbohydrates can be applied to test even real market beverages with a high sensitivity and selectivity.
△ Less
Submitted 28 June, 2015;
originally announced June 2015.
-
Graphene terahertz modulators by ionic liquid gating
Authors:
Yang Wu,
Chan La-o-vorakiat,
Xuepeng Qiu,
Jingbo Liu,
Praveen Deorani,
Karan Banerjee,
Jaesung Son,
Yuanfu Chen,
Elbert E. M. Chia,
Hyunsoo Yang
Abstract:
Graphene based THz modulators are promising due to the conical band structure and high carrier mobility of graphene. Here, we tune the Fermi level of graphene via electrical gating with the help of ionic liquid to control the THz transmittance. It is found that, in the THz range, both the absorbance and reflectance of the device increase proportionately to the available density of states due to in…
▽ More
Graphene based THz modulators are promising due to the conical band structure and high carrier mobility of graphene. Here, we tune the Fermi level of graphene via electrical gating with the help of ionic liquid to control the THz transmittance. It is found that, in the THz range, both the absorbance and reflectance of the device increase proportionately to the available density of states due to intraband transitions. Compact, stable, and repeatable THz transmittance modulation up to 93% (or 99%) for a single (or stacked) device has been demonstrated in a broad frequency range from 0.1 to 2.5 THz, with an applied voltage of only 3 V at room temperature.
△ Less
Submitted 8 June, 2015;
originally announced June 2015.