Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (117 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 18 July, 2024; v1 submitted 10 July, 2024;
originally announced July 2024.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Supernova Electron-Neutrino Interactions with Xenon in the nEXO Detector
Authors:
nEXO Collaboration,
S. Hedges,
S. Al Kharusi,
E. Angelico,
J. P. Brodsky,
G. Richardson,
S. Wilde,
A. Amy,
A. Anker,
I. J. Arnquist,
P. Arsenault,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao
, et al. (121 additional authors not shown)
Abstract:
Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theor…
▽ More
Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-beta decay detector (~5-tonne, 90% ${}^{136}$Xe, 10% ${}^{134}$Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the MARLEY event generator. We find good agreement between MARLEY's predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector's efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5 to 8 kpc from earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley,
H. Coombes
, et al. (108 additional authors not shown)
Abstract:
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nuc…
▽ More
We present a new analysis of previously published of SuperCDMS data using a profile likelihood framework to search for sub-GeV dark matter (DM) particles through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering these possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that are undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search provides overall considerably more stringent limits and excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 17 February, 2023;
originally announced February 2023.
-
G4CMP: Condensed Matter Physics Simulation Using the Geant4 Toolkit
Authors:
M. H. Kelsey,
R. Agnese,
Y. F. Alam,
I. Ataee Langroudy,
E. Azadbakht,
D. Brandt,
R. Bunker,
B. Cabrera,
Y. -Y. Chang,
H. Coombes,
R. M. Cormier,
M. D. Diamond,
E. R. Edwards,
E. Figueroa-Feliciano,
J. Gao,
P. M. Harrington,
Z. Hong,
M. Hui,
N. A. Kurinsky,
R. E. Lawrence,
B. Loer,
M. G. Masten,
E. Michaud,
E. Michielin,
J. Miller
, et al. (22 additional authors not shown)
Abstract:
G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reprod…
▽ More
G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.
△ Less
Submitted 12 February, 2023;
originally announced February 2023.
-
Report of the 2021 U.S. Community Study on the Future of Particle Physics (Snowmass 2021) Summary Chapter
Authors:
Joel N. Butler,
R. Sekhar Chivukula,
André de Gouvêa,
Tao Han,
Young-Kee Kim,
Priscilla Cushman,
Glennys R. Farrar,
Yury G. Kolomensky,
Sergei Nagaitsev,
Nicolás Yunes,
Stephen Gourlay,
Tor Raubenheimer,
Vladimir Shiltsev,
Kétévi A. Assamagan,
Breese Quinn,
V. Daniel Elvira,
Steven Gottlieb,
Benjamin Nachman,
Aaron S. Chou,
Marcelle Soares-Santos,
Tim M. P. Tait,
Meenakshi Narain,
Laura Reina,
Alessandro Tricoli,
Phillip S. Barbeau
, et al. (18 additional authors not shown)
Abstract:
The 2021-22 High-Energy Physics Community Planning Exercise (a.k.a. ``Snowmass 2021'') was organized by the Division of Particles and Fields of the American Physical Society. Snowmass 2021 was a scientific study that provided an opportunity for the entire U.S. particle physics community, along with its international partners, to identify the most important scientific questions in High Energy Physi…
▽ More
The 2021-22 High-Energy Physics Community Planning Exercise (a.k.a. ``Snowmass 2021'') was organized by the Division of Particles and Fields of the American Physical Society. Snowmass 2021 was a scientific study that provided an opportunity for the entire U.S. particle physics community, along with its international partners, to identify the most important scientific questions in High Energy Physics for the following decade, with an eye to the decade after that, and the experiments, facilities, infrastructure, and R&D needed to pursue them. This Snowmass summary report synthesizes the lessons learned and the main conclusions of the Community Planning Exercise as a whole and presents a community-informed synopsis of U.S. particle physics at the beginning of 2023. This document, along with the Snowmass reports from the various subfields, will provide input to the 2023 Particle Physics Project Prioritization Panel (P5) subpanel of the U.S. High-Energy Physics Advisory Panel (HEPAP), and will help to guide and inform the activity of the U.S. particle physics community during the next decade and beyond.
△ Less
Submitted 3 December, 2023; v1 submitted 16 January, 2023;
originally announced January 2023.
-
Snowmass 2021 Underground Facilities and Infrastructure Overview Topical Report
Authors:
L. Baudis,
J. Hall,
K. T. Lesko,
J. L. Orrell
Abstract:
The Underground Frontier (UF) was charged with assessing the anticipated needs and available space for well shielded underground space to conduct scientific research. The Frontier sought to understand the existing space, space that would become available in the coming decade, and potential for creating additional space to host these efforts. To this end UF created a survey which was sent to existi…
▽ More
The Underground Frontier (UF) was charged with assessing the anticipated needs and available space for well shielded underground space to conduct scientific research. The Frontier sought to understand the existing space, space that would become available in the coming decade, and potential for creating additional space to host these efforts. To this end UF created a survey which was sent to existing underground laboratories. This assessment was necessary for UF to develop a bold plan to foster and empower broad reaching underground research, maximize cost savings and synergistic research opportunities, and advance the HEP research program requiring underground space for the next two decades.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
-
Snowmass 2021 Underground Facilities & Infrastructure Frontier Report
Authors:
Laura Baudis,
Jeter Hall,
Kevin T. Lesko,
John L. Orrell
Abstract:
The decade since Snowmass 2013 has seen extraordinary progress of high energy physics research performed--or planned for--at underground facilities. Drs. T. Kajita and A.B. McDonald were awarded the 2015 Nobel Prize in Physics for the discovery of neutrino oscillation, which show that neutrinos have mass. The U.S. has embarked on the development of the world-class LBNF/DUNE science program to inve…
▽ More
The decade since Snowmass 2013 has seen extraordinary progress of high energy physics research performed--or planned for--at underground facilities. Drs. T. Kajita and A.B. McDonald were awarded the 2015 Nobel Prize in Physics for the discovery of neutrino oscillation, which show that neutrinos have mass. The U.S. has embarked on the development of the world-class LBNF/DUNE science program to investigate neutrino properties. The Generation 2 dark matter program is advancing to full data collection in the coming 5 years, a Dark Matter New Initiatives program has begun, and the U.S. dark matter community is looking toward a Generation 3 program of large-scale dark matter direct detection searches. The Sanford Underground Research Facility has become a focal point for U.S. underground facilities and infrastructure investment. The status since the 2013 Snowmass process as well as the outcome from the 2014 P5 program of recommendations is reviewed. These are then evaluated based on the activities and discussions of the Snowmass 2021 process resulting in conclusions looking forward to the coming decade of high energy physics research performed in underground facilities.
△ Less
Submitted 24 November, 2022;
originally announced November 2022.
-
Snowmass 2021 Topical Report on Synergies in Research at Underground Facilities
Authors:
Catalina Curceanu,
Derek Elsworth,
Joe Formaggio,
Jan Harms,
Daniel Robertson,
William Roggenthen,
Herb Wang,
Sijbrand de Jong,
John L. Orrell
Abstract:
This is a Snowmass 2021 Topical Report for the Underground Facilities and Infrastructure Frontier on Synergies in Research at Underground Facilities: A broad range of scientific and engineering research is possible in underground laboratories, beyond the physics-focused activities described in the other Underground Facilities and Infrastructure Topical Reports. These areas of research include nucl…
▽ More
This is a Snowmass 2021 Topical Report for the Underground Facilities and Infrastructure Frontier on Synergies in Research at Underground Facilities: A broad range of scientific and engineering research is possible in underground laboratories, beyond the physics-focused activities described in the other Underground Facilities and Infrastructure Topical Reports. These areas of research include nuclear astrophysics, geology, geoengineering, gravitational wave detection, biology, and perhaps soon quantum information science. This UF Topical Report will survey those other scientific and engineering research activities that share interest in research-orientated Underground Facilities and Infrastructure. In most cases the breadth and depth of research aims is too large to cover in completeness and references to surveys or key documents for those fields are provided after introductory summaries. Additional attention is then given to shared, similar, and unique needs of each research area with respect to the broader underground research community's Underground Facilities and Infrastructure needs. Where potential conflicts of usage type, site, or duration might arise, these are identified.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
Effective Field Theory Analysis of CDMSlite Run 2 Data
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (105 additional authors not shown)
Abstract:
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected back…
▽ More
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Snowmass2021 Cosmic Frontier White Paper: Calibrations and backgrounds for dark matter direct detection
Authors:
Daniel Baxter,
Raymond Bunker,
Sally Shaw,
Shawn Westerdale,
Isaac Arnquist,
Daniel S. Akerib,
Rob Calkins,
Susana Cebrián,
James B. Dent,
Maria Laura di Vacri,
Jim Dobson,
Daniel Egana-Ugrinovic,
Andrew Erlandson,
Chamkaur Ghag,
Carter Hall,
Jeter Hall,
Scott Haselschwardt,
Eric Hoppe,
Chris M. Jackson,
Yonatan Kahn,
Alvine Kamaha,
Mike Kelsey,
Alexander Kish,
Noah Kurinsky,
Matthias Laubenstein
, et al. (26 additional authors not shown)
Abstract:
Future dark matter direct detection experiments will reach unprecedented levels of sensitivity. Achieving this sensitivity will require more precise models of signal and background rates in future detectors. Improving the precision of signal and background modeling goes hand-in-hand with novel calibration techniques that can probe rare processes and lower threshold detector response. The goal of t…
▽ More
Future dark matter direct detection experiments will reach unprecedented levels of sensitivity. Achieving this sensitivity will require more precise models of signal and background rates in future detectors. Improving the precision of signal and background modeling goes hand-in-hand with novel calibration techniques that can probe rare processes and lower threshold detector response. The goal of this white paper is to outline community needs to meet the background and calibration requirements of next-generation dark matter direct detection experiments.
△ Less
Submitted 1 May, 2022; v1 submitted 14 March, 2022;
originally announced March 2022.
-
A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS
Authors:
SuperCDMS Collaboration,
Musaab Al-Bakry,
Imran Alkhatib,
Dorian Praia do Amaral,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Iman Ataee Langroudy,
Elham Azadbakht,
Samir Banik,
Corey Bathurst,
Dan Bauer,
Lucas Bezerra,
Rik Bhattacharyya,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Robert Cameron,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Mouli Chaudhuri,
Ran Chen,
Nicholas Chott
, et al. (106 additional authors not shown)
Abstract:
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucle…
▽ More
In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.
△ Less
Submitted 19 May, 2022; v1 submitted 4 March, 2022;
originally announced March 2022.
-
Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches
Authors:
A. Avasthi,
T. W. Bowyer,
C. Bray,
T. Brunner,
N. Catarineu,
E. Church,
R. Guenette,
S. J. Haselschwardt,
J. C. Hayes,
M. Heffner,
S. A. Hertel,
P. H. Humble,
A. Jamil,
S. Kim,
R. F. Lang,
K. G. Leach,
B. G. Lenardo,
W. H. Lippincott,
A. Marino,
D. N. McKinsey,
E. H. Miller,
D. C. Moore,
B. Mong,
B. Monreal,
M. E. Monzani
, et al. (9 additional authors not shown)
Abstract:
Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay ($0νββ$) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas or liquid phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomen…
▽ More
Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay ($0νββ$) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas or liquid phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time projection chambers (TPCs) to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for $0νββ$ at half-life sensitivities as long as $10^{30}$ yr.
△ Less
Submitted 21 December, 2021; v1 submitted 4 October, 2021;
originally announced October 2021.
-
Opportunities for DOE National Laboratory-led QuantISED Experiments
Authors:
Pete Barry,
Karl Berggren,
A. Baha Balantekin,
John Bollinger,
Ray Bunker,
Ilya Charaev,
Jeff Chiles,
Aaron Chou,
Marcel Demarteau,
Joe Formaggio,
Peter Graham,
Salman Habib,
David Hume,
Kent Irwin,
Mikhail Lukin,
Joseph Lykken,
Reina Maruyama,
Holger Mueller,
SaeWoo Nam,
Andrei Nomerotski,
John Orrell,
Robert Plunkett,
Raphael Pooser,
John Preskill,
Surjeet Rajendran
, et al. (2 additional authors not shown)
Abstract:
A subset of QuantISED Sensor PIs met virtually on May 26, 2020 to discuss a response to a charge by the DOE Office of High Energy Physics. In this document, we summarize the QuantISED sensor community discussion, including a consideration of HEP science enabled by quantum sensors, describing the distinction between Quantum 1.0 and Quantum 2.0, and discussing synergies/complementarity with the new…
▽ More
A subset of QuantISED Sensor PIs met virtually on May 26, 2020 to discuss a response to a charge by the DOE Office of High Energy Physics. In this document, we summarize the QuantISED sensor community discussion, including a consideration of HEP science enabled by quantum sensors, describing the distinction between Quantum 1.0 and Quantum 2.0, and discussing synergies/complementarity with the new DOE NQI centers and with research supported by other SC offices.
Quantum 2.0 advances in sensor technology offer many opportunities and new approaches for HEP experiments. The DOE HEP QuantISED program could support a portfolio of small experiments based on these advances. QuantISED experiments could use sensor technologies that exemplify Quantum 2.0 breakthroughs. They would strive to achieve new HEP science results, while possibly spinning off other domain science applications or serving as pathfinders for future HEP science targets. QuantISED experiments should be led by a DOE laboratory, to take advantage of laboratory technical resources, infrastructure, and expertise in the safe and efficient construction, operation, and review of experiments.
The QuantISED PIs emphasized that the quest for HEP science results under the QuantISED program is distinct from the ongoing DOE HEP programs on the energy, intensity, and cosmic frontiers. There is robust evidence for the existence of particles and phenomena beyond the Standard Model, including dark matter, dark energy, quantum gravity, and new physics responsible for neutrino masses, cosmic inflation, and the cosmic preference for matter over antimatter. Where is this physics and how do we find it? The QuantISED program can exploit new capabilities provided by quantum technology to probe these kinds of science questions in new ways and over a broader range of science parameters than can be achieved with conventional techniques.
△ Less
Submitted 21 March, 2021; v1 submitted 5 February, 2021;
originally announced February 2021.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Antineutrino Detectors Remain Impractical for Nuclear Explosion Monitoring
Authors:
Michael Foxe,
Theodore Bowyer,
Rachel Carr,
John Orrell,
Brent VanDevender
Abstract:
Fission explosions produce large numbers of antineutrinos. It is occasionally asked whether this distinctive, unshieldable emission could help reveal clandestine nuclear weapon explosions. The practical challenge encountered is that detectors large enough for this application are cost prohibitive, likely on the multi-billion-dollar scale. In this paper, we review several hypothetical use cases for…
▽ More
Fission explosions produce large numbers of antineutrinos. It is occasionally asked whether this distinctive, unshieldable emission could help reveal clandestine nuclear weapon explosions. The practical challenge encountered is that detectors large enough for this application are cost prohibitive, likely on the multi-billion-dollar scale. In this paper, we review several hypothetical use cases for antineutrino detectors as supplements to the seismic, infrasound, hydroacoustic, and airborne radionuclide sensors of the Comprehensive Nuclear-Test-Ban Treaty Organization's International Monitoring System. In each case, if an anti-neutrino detector could be constructed that would compete with existing capabilities, we conclude that the cost would considerably outstrip the value it might add to the existing monitoring network, compared to the significantly lower costs for the same or superior capability.
△ Less
Submitted 27 March, 2020;
originally announced May 2020.
-
Evaluation and mitigation of trace $^{210}$Pb contamination on copper surfaces
Authors:
Raymond Bunker,
Tsuguo Aramaki,
Isaac Arnquist,
Robert Calkins,
Jodi Cooley,
Eric Hoppe,
John Orrell,
Kimbrelle Thommasson
Abstract:
Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availability. In this paper, we describe methods to assay and mitigate $^{210}$Pb contamination on copper surfaces, such as from exposure to environmental radon or coming from bulk impurities. We evaluated the efficacy of wet e…
▽ More
Clean materials are required to construct and operate many low-background physics experiments. High-purity copper has found broad use because of its physical properties and availability. In this paper, we describe methods to assay and mitigate $^{210}$Pb contamination on copper surfaces, such as from exposure to environmental radon or coming from bulk impurities. We evaluated the efficacy of wet etching on commercial samples and observed that $^{210}$Po contamination from the copper bulk does not readily pass into solution. During the etch, the polonium appears to trap at the copper-etchant boundary, such that it is effectively concentrated at the copper surface. We observed a different behavior for $^{210}$Pb; high-sensitivity measurements of the alpha emissivity versus time indicate the lowest level of $^{210}$Pb contamination ever reported for a commercial copper surface: $0\pm12$ nBq/cm$^2$ (1$σ$). Additionally, we have demonstrated the effectiveness of mitigating trace $^{210}$Pb and $^{210}$Po surface backgrounds using custom, high-purity electroplating techniques. These approaches were evaluated utilizing assays performed with an XIA UltraLo-1800 alpha spectrometer.
△ Less
Submitted 10 April, 2020; v1 submitted 13 March, 2020;
originally announced March 2020.
-
Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths
Authors:
P. Lv,
G. F. Cao,
L. J. Wen,
S. Al Kharusi,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
M. Chiu,
B. Cleveland,
M. Coon,
A. Craycraft
, et al. (126 additional authors not shown)
Abstract:
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinct…
▽ More
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.
△ Less
Submitted 4 December, 2019;
originally announced December 2019.
-
Constraints on dark photons and axion-like particles from SuperCDMS Soudan
Authors:
SuperCDMS Collaboration,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
H. Coombes,
J. Corbett
, et al. (82 additional authors not shown)
Abstract:
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 5…
▽ More
We present an analysis of electron recoils in cryogenic germanium detectors operated during the SuperCDMS Soudan experiment. The data are used to set new constraints on the axioelectric coupling of axion-like particles and the kinetic mixing parameter of dark photons, assuming the respective species constitutes all of the galactic dark matter. This study covers the mass range from 40 eV/$c^2$ to 500 eV/$c^2$ for both candidates, excluding previously untested parameter space for masses below ~1 keV/$c^2$. For the kinetic mixing of dark photons, values below $10^{-15}$ are reached for particle masses around 100 eV/$c^2$; for the axioelectric coupling of axion-like particles, values below $10^{-12}$ are reached for particles with masses in the range of a few-hundred eV/$c^2$.
△ Less
Submitted 18 January, 2021; v1 submitted 26 November, 2019;
originally announced November 2019.
-
Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon
Authors:
P. Nakarmi,
I. Ostrovskiy,
A. K. Soma,
F. Retiere,
S. Al Kharusi,
M. Alfaris,
G. Anton,
I. J. Arnquist,
I. Badhrees,
P. S. Barbeau,
D. Beck,
V. Belov,
T. Bhatta,
J. Blatchford,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
S. Byrne Mamahit,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois
, et al. (130 additional authors not shown)
Abstract:
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently a…
▽ More
Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.
△ Less
Submitted 24 December, 2019; v1 submitted 14 October, 2019;
originally announced October 2019.
-
Treatment of material radioassay measurements in projecting sensitivity for low-background experiments
Authors:
R. H. M. Tsang,
I. J. Arnquist,
E. W. Hoppe,
J. L. Orrell,
R. Saldanha
Abstract:
By analyzing sensitivity projections as a statisical estimation problem, we evaluated different ways of treating radioassay measurement results (values and upper limits) when projecting sensitivity for low-background experiments. We developed a figure of merit that incorporates a notion of conservativeness to quantitatively explore the consequences of attempts to bias sensitivity projections, and…
▽ More
By analyzing sensitivity projections as a statisical estimation problem, we evaluated different ways of treating radioassay measurement results (values and upper limits) when projecting sensitivity for low-background experiments. We developed a figure of merit that incorporates a notion of conservativeness to quantitatively explore the consequences of attempts to bias sensitivity projections, and proposed a method to report sensitivity.
△ Less
Submitted 28 August, 2018; v1 submitted 15 August, 2018;
originally announced August 2018.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
COHERENT Collaboration data release from the first observation of coherent elastic neutrino-nucleus scattering
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
A. Brown,
A. Burenkov,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
C. Cuesta,
J. Daughhetee,
D. J. Dean,
M. del Valle Coello,
J. Detwiler,
M. D'Onofrio,
A. Eberhardt,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
This release includes data and information necessary to perform independent analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294 [nucl-ex]. Data is shared in a binned, text-based format, including both "signal" and "background" regions, so that counts and associated uncertainties can be quantitatively calculated for the purpose of separate analyses. This document describes…
▽ More
This release includes data and information necessary to perform independent analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294 [nucl-ex]. Data is shared in a binned, text-based format, including both "signal" and "background" regions, so that counts and associated uncertainties can be quantitatively calculated for the purpose of separate analyses. This document describes the included information and its format, offering some guidance on use of the data. Accompanying code examples show basic interaction with the data using Python.
△ Less
Submitted 25 April, 2018;
originally announced April 2018.
-
Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (79 additional authors not shown)
Abstract:
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ (…
▽ More
We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times 10^{-44}$ ($1.0 \times 10^{-44}$) cm$^2$ at 46 GeV/$c^2$. These results set the strongest limits for WIMP--germanium-nucleus interactions for masses $>$12 GeV/$c^2$.
△ Less
Submitted 29 August, 2017;
originally announced August 2017.
-
Observation of Coherent Elastic Neutrino-Nucleus Scattering
Authors:
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
A. Brown,
A. Bolozdynya,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. J. Cooper,
R. L. Cooper,
C. Cuesta,
D. J. Dean,
J. A. Detwiler,
A. Eberhardt,
Y. Efremenko,
S. R. Elliott,
E. M. Erkela,
L. Fabris,
M. Febbraro,
N. E. Fields,
W. Fox
, et al. (56 additional authors not shown)
Abstract:
The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross-section is the largest by far of all low-energy neutrino couplings. This mode of interaction provides new opportunities to study neutrino properties, and leads to a miniaturization of detector size, with potential technological applications. We observe this process at a 6.…
▽ More
The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross-section is the largest by far of all low-energy neutrino couplings. This mode of interaction provides new opportunities to study neutrino properties, and leads to a miniaturization of detector size, with potential technological applications. We observe this process at a 6.7-sigma confidence level, using a low-background, 14.6-kg CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the Standard Model for this process, are observed in high signal-to-background conditions. Improved constraints on non-standard neutrino interactions with quarks are derived from this initial dataset.
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
Naturally occurring $^{32}$Si and low-background silicon dark matter detectors
Authors:
J. L. Orrell,
I. J. Arnquist,
M. Bliss,
R. Bunker,
Z. S. Finch
Abstract:
The naturally occurring radioisotope $^{32}$Si represents a potentially limiting background in future dark matter direct-detection experiments. We investigate sources of $^{32}$Si and the vectors by which it comes to reside in silicon crystals used for fabrication of radiation detectors. We infer that the $^{32}$Si concentration in commercial single-crystal silicon is likely variable, dependent up…
▽ More
The naturally occurring radioisotope $^{32}$Si represents a potentially limiting background in future dark matter direct-detection experiments. We investigate sources of $^{32}$Si and the vectors by which it comes to reside in silicon crystals used for fabrication of radiation detectors. We infer that the $^{32}$Si concentration in commercial single-crystal silicon is likely variable, dependent upon the specific geologic and hydrologic history of the source (or sources) of silicon "ore" and the details of the silicon-refinement process. The silicon production industry is large, highly segmented by refining step, and multifaceted in terms of final product type, from which we conclude that production of $^{32}$Si-mitigated crystals requires both targeted silicon material selection and a dedicated refinement-through-crystal-production process. We review options for source material selection, including quartz from an underground source and silicon isotopically reduced in $^{32}$Si. To quantitatively evaluate the $^{32}$Si content in silicon metal and precursor materials, we propose analytic methods employing chemical processing and radiometric measurements. Ultimately, it appears feasible to produce silicon detectors with low levels of $^{32}$Si, though significant assay method development is required to validate this claim and thereby enable a quality assurance program during an actual controlled silicon-detector production cycle.
△ Less
Submitted 19 February, 2018; v1 submitted 31 July, 2017;
originally announced August 2017.
-
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Authors:
Marco Battaglieri,
Alberto Belloni,
Aaron Chou,
Priscilla Cushman,
Bertrand Echenard,
Rouven Essig,
Juan Estrada,
Jonathan L. Feng,
Brenna Flaugher,
Patrick J. Fox,
Peter Graham,
Carter Hall,
Roni Harnik,
JoAnne Hewett,
Joseph Incandela,
Eder Izaguirre,
Daniel McKinsey,
Matthew Pyle,
Natalie Roe,
Gray Rybka,
Pierre Sikivie,
Tim M. P. Tait,
Natalia Toro,
Richard Van De Water,
Neal Weiner
, et al. (226 additional authors not shown)
Abstract:
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
△ Less
Submitted 14 July, 2017;
originally announced July 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Initial Results from the MAJORANA DEMONSTRATOR
Authors:
S. R. Elliott,
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
A. Fullmer,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
M. P. Green,
J. Gruszko
, et al. (42 additional authors not shown)
Abstract:
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge)…
▽ More
Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in $^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg enriched in $^{76}$Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the {\sc Demonstrator} are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the first detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and first physics run, as well as the status and potential physics reach of the full {\sc Majorana Demonstrator} experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.
△ Less
Submitted 4 October, 2016;
originally announced October 2016.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
High voltage testing for the MAJORANA Demonstrator
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
Z. Fu,
A. Galindo-Uribarri,
G. K. Giovanetti,
J. Goett
, et al. (48 additional authors not shown)
Abstract:
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector sign…
▽ More
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of the MAJORANA Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the MAJORANA Demonstrator was characterized and the micro-discharge effects during the MAJORANA Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.
△ Less
Submitted 28 March, 2016; v1 submitted 28 March, 2016;
originally announced March 2016.
-
Muon Flux Measurements at the Davis Campus of the Sanford Underground Research Facility with the Majorana Demonstrator Veto System
Authors:
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
C. Dunagan,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
A. Galindo-Uribarri,
T. Gilliss,
G. K. Giovanetti,
J. Goett,
M. P. Green
, et al. (49 additional authors not shown)
Abstract:
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
We report the first measurement of the total MUON flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 ft level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9 muons/s/cm^2.
△ Less
Submitted 7 September, 2016; v1 submitted 24 February, 2016;
originally announced February 2016.
-
The Majorana Demonstrator Radioassay Program
Authors:
N. Abgrall,
I. J. Arnquist,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
A. W. Bradley,
V. Brudanin,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
C. Cuesta,
J. A. Detwiler,
J. A. Dunmore,
Yu. Efremenko,
H. Ejiri,
S. R. Elliott,
P. Finnerty,
A. Galindo-Uribarri,
V. M. Gehman
, et al. (60 additional authors not shown)
Abstract:
The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires tha…
▽ More
The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires that the apparatus be extremely low in radioactive isotopes whose decays may produce backgrounds to the search. The radioassay program conducted by the collaboration to ensure that the materials comprising the apparatus are sufficiently pure is described. The resulting measurements of the radioactive-isotope contamination for a number of materials studied for use in the detector are reported.
△ Less
Submitted 22 April, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Coherent neutrino-nucleus scattering detection with a CsI[Na] scintillator at the SNS spallation source
Authors:
J. I. Collar,
N. E. Fields,
E. Fuller,
M. Hai,
T. W. Hossbach,
J. L. Orrell,
G. Perumpilly,
B. Scholz
Abstract:
We study the possibility of using CsI[Na] scintillators as an advantageous target for the detection of coherent elastic neutrino-nucleus scattering (CENNS), using the neutrino emissions from the SNS spallation source at Oak Ridge National Laboratory. The response of this material to low-energy nuclear recoils like those expected from this process is characterized. Backgrounds are studied using a 2…
▽ More
We study the possibility of using CsI[Na] scintillators as an advantageous target for the detection of coherent elastic neutrino-nucleus scattering (CENNS), using the neutrino emissions from the SNS spallation source at Oak Ridge National Laboratory. The response of this material to low-energy nuclear recoils like those expected from this process is characterized. Backgrounds are studied using a 2 kg low-background prototype crystal in a dedicated radiation shield. The conclusion is that a planned 14 kg detector should measure approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr low-energy threshold, with a signal-to-background ratio sufficient for a first measurement of the CENNS cross-section. The cross-section for the $^{208}$Pb($ν_{e},e^{-}$)$^{208}$Bi reaction, of interest for future supernova neutrino detection, can be simultaneously obtained.
△ Less
Submitted 20 August, 2014; v1 submitted 28 July, 2014;
originally announced July 2014.
-
A Dark Matter Search with MALBEK
Authors:
G. K. Giovanetti,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
D. Byram,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
C. Cuesta,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
S. R. Elliott,
J. E. Fast,
P. Finnerty,
F. M. Fraenkle,
A. Galindo-Uribarri
, et al. (62 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimb…
▽ More
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity germanium detectors that will search for the neutrinoless double-beta decay of 76-Ge and perform a search for weakly interacting massive particles (WIMPs) with masses below 10 GeV. As part of the MAJORANA research and development efforts, we have deployed a modified, low-background broad energy germanium detector at the Kimballton Underground Research Facility. With its sub-keV energy threshold, this detector is sensitive to potential non-Standard Model physics, including interactions with WIMPs. We discuss the backgrounds present in the WIMP region of interest and explore the impact of slow surface event contamination when searching for a WIMP signal.
△ Less
Submitted 8 July, 2014;
originally announced July 2014.
-
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of CoGeNT Data
Authors:
C. E. Aalseth,
P. S. Barbeau,
J. Diaz Leon,
J. E. Fast,
T. W. Hossbach,
A. Knecht,
M. S. Kos,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell
Abstract:
CoGeNT has taken data for over 3 years, with 1136 live days of data accumulated as of April 23, 2013. We report on the results of a maximum likelihood analysis to extract any possible dark matter signal present in the collected data. The maximum likelihood signal extraction uses 2-dimensional probability density functions (PDFs) to characterize the anticipated variations in dark matter interaction…
▽ More
CoGeNT has taken data for over 3 years, with 1136 live days of data accumulated as of April 23, 2013. We report on the results of a maximum likelihood analysis to extract any possible dark matter signal present in the collected data. The maximum likelihood signal extraction uses 2-dimensional probability density functions (PDFs) to characterize the anticipated variations in dark matter interaction rates for given observable nuclear recoil energies during differing periods of the Earth's annual orbit around the Sun. Cosmogenic and primordial radioactivity backgrounds are characterized by their energy signatures and in some cases decay half-lives. A third parameterizing variable -- pulse rise-time -- is added to the likelihood analysis to characterize slow rising pulses described in prior analyses. The contribution to each event category is analyzed for various dark matter signal hypotheses including a dark matter standard halo model and a case with free oscillation parameters (i.e., amplitude, period, and phase). The best-fit dark matter signal is in close proximity to previously reported results. We find that the significance of the extracted dark matter signal remains well below evidentiary at 1.7 $σ$.
△ Less
Submitted 5 February, 2015; v1 submitted 23 January, 2014;
originally announced January 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter Detector Data
Authors:
C. E. Aalseth,
P. S. Barbeau,
J. Colaresi,
J. I. Collar,
J. Diaz Leon,
J. E. Fast,
N. E. Fields,
T. W. Hossbach,
A. Knecht,
M. S. Kos,
M. G. Marino,
H. S. Miley,
M. L. Miller,
J. L. Orrell,
K. M. Yocum
Abstract:
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a regi…
▽ More
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter candidates. WIMP interactions with sensitive detectors are expected to display a characteristic annual modulation in rate. We release a dataset spanning 3.4 years of operation from a low-background germanium detector, designed to search for this signature. A previously reported modulation persists, concentrated in a region of the energy spectrum populated by an exponential excess of unknown origin. Its phase and period agree with phenomenological expectations, but its amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP galactic halo. We consider the possibility of a non-Maxwellian local halo velocity distribution as a plausible explanation, able to help reconcile recently reported WIMP search anomalies.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.
-
Low Background Materials and Assay - A Supplement to the Cosmic Frontier CF1 Summary
Authors:
J. Cooley,
P. Cushman,
E. W. Hoppe,
J. L. Orrell,
R. W. Schnee
Abstract:
This White Paper provides a supplement to the Snowmass Summary from CF1 (Cosmic Frontier WIMP Direct Detection). It was largely prepared during the August 2013 Community Planning Meeting and relies on information gathered from the larger dark matter community. It is a more detailed answer to the CF1 Charge: "Identify the common infrastructure required to meet the scientific and technical goals of…
▽ More
This White Paper provides a supplement to the Snowmass Summary from CF1 (Cosmic Frontier WIMP Direct Detection). It was largely prepared during the August 2013 Community Planning Meeting and relies on information gathered from the larger dark matter community. It is a more detailed answer to the CF1 Charge: "Identify the common infrastructure required to meet the scientific and technical goals of dark matter direct detection." The community as a whole recognizes that sensitive searches for WIMPs require identification, quantification, and procurement of radiopure materials. The lack of sufficient resources in this area is a major project risk for future experiments and can limit scientific reach
△ Less
Submitted 15 November, 2013; v1 submitted 13 November, 2013;
originally announced November 2013.
-
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Authors:
P. Cushman,
C. Galbiati,
D. N. McKinsey,
H. Robertson,
T. M. P. Tait,
D. Bauer,
A. Borgland,
B. Cabrera,
F. Calaprice,
J. Cooley,
T. Empl,
R. Essig,
E. Figueroa-Feliciano,
R. Gaitskell,
S. Golwala,
J. Hall,
R. Hill,
A. Hime,
E. Hoppe,
L. Hsu,
E. Hungerford,
R. Jacobsen,
M. Kelsey,
R. F. Lang,
W. H. Lippincott
, et al. (24 additional authors not shown)
Abstract:
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter spa…
▽ More
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
△ Less
Submitted 3 November, 2013; v1 submitted 30 October, 2013;
originally announced October 2013.
-
Sensor Compendium
Authors:
M. Artuso,
M. Battaglia,
G. Bolla,
D. Bortoletto,
B. Cabrera,
J. E. Carlstrom,
C. L. Chang,
W. Cooper,
C. Da Via,
M. Demarteau,
J. Fast,
H. Frisch,
M. Garcia-Sciveres,
S. Golwala,
C. Haber,
J. Hall,
E. Hoppe,
K. D. Irwin,
H. Kagan,
C. Kenney,
A. T. Lee,
D. Lynn,
J. Orrell,
M. Pyle,
R. Rusack
, et al. (7 additional authors not shown)
Abstract:
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, e…
▽ More
Sensors play a key role in detecting both charged particles and photons for all three frontiers in Particle Physics. The signals from an individual sensor that can be used include ionization deposited, phonons created, or light emitted from excitations of the material. The individual sensors are then typically arrayed for detection of individual particles or groups of particles. Mounting of new, ever higher performance experiments, often depend on advances in sensors in a range of performance characteristics. These performance metrics can include position resolution for passing particles, time resolution on particles impacting the sensor, and overall rate capabilities. In addition the feasible detector area and cost frequently provides a limit to what can be built and therefore is often another area where improvements are important. Finally, radiation tolerance is becoming a requirement in a broad array of devices. We present a status report on a broad category of sensors, including challenges for the future and work in progress to solve those challenges
△ Less
Submitted 25 October, 2013; v1 submitted 18 October, 2013;
originally announced October 2013.
-
Coherent Scattering Investigations at the Spallation Neutron Source: a Snowmass White Paper
Authors:
D. Akimov,
A. Bernstein,
P. Barbeau,
P. Barton,
A. Bolozdynya,
B. Cabrera-Palmer,
F. Cavanna,
V. Cianciolo,
J. Collar,
R. J. Cooper,
D. Dean,
Y. Efremenko,
A. Etenko,
N. Fields,
M. Foxe,
E. Figueroa-Feliciano,
N. Fomin,
F. Gallmeier,
I. Garishvili,
M. Gerling,
M. Green,
G. Greene,
A. Hatzikoutelis,
R. Henning,
R. Hix
, et al. (32 additional authors not shown)
Abstract:
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, Tennessee, provides an intense flux of neutrinos in the few tens-of-MeV range, with a sharply-pulsed timing structure that is beneficial for background rejection. In this white paper, we describe how the SNS source can be used for a measurement of coherent elastic neutrino-nucleus scattering (CENNS), and the physics reach of dif…
▽ More
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, Tennessee, provides an intense flux of neutrinos in the few tens-of-MeV range, with a sharply-pulsed timing structure that is beneficial for background rejection. In this white paper, we describe how the SNS source can be used for a measurement of coherent elastic neutrino-nucleus scattering (CENNS), and the physics reach of different phases of such an experimental program (CSI: Coherent Scattering Investigations at the SNS).
△ Less
Submitted 30 September, 2013;
originally announced October 2013.
-
The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76
Authors:
MAJORANA Collaboration,
S. R. Elliott,
N. Abgrall,
E. Aguayo,
F. T. Avignone III,
A. S. Barabash,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
M. Busch,
A. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
D. C. Combs,
J. A. Detwiler,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri,
J. Esterline,
J. E. Fast,
P. Finnerty,
F. M. Fraenkleo,
A. Galindo-Uribarri,
G. K. Giovanetti
, et al. (58 additional authors not shown)
Abstract:
The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using $^{76}$Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining…
▽ More
The {\sc Majorana} collaboration is searching for neutrinoless double beta decay using $^{76}$Ge, which has been shown to have a number of advantages in terms of sensitivities and backgrounds. The observation of neutrinoless double-beta decay would show that lepton number is violated and that neutrinos are Majorana particles and would simultaneously provide information on neutrino mass. Attaining sensitivities for neutrino masses in the inverted hierarchy region, $15 - 50$ meV, will require large, tonne-scale detectors with extremely low backgrounds, at the level of $\sim$1 count/t-y or lower in the region of the signal. The {\sc Majorana} collaboration, with funding support from DOE Office of Nuclear Physics and NSF Particle Astrophysics, is constructing the {\sc Demonstrator}, an array consisting of 40 kg of p-type point-contact high-purity germanium (HPGe) detectors, of which $\sim$30 kg will be enriched to 87% in $^{76}$Ge. The {\sc Demonstrator} is being constructed in a clean room laboratory facility at the 4850' level (4300 m.w.e.) of the Sanford Underground Research Facility (SURF) in Lead, SD. It utilizes a compact graded shield approach with the inner portion consisting of ultra-clean Cu that is being electroformed and machined underground. The primary aim of the {\sc Demonstrator} is to show the feasibility of a future tonne-scale measurement in terms of backgrounds and scalability.
△ Less
Submitted 29 July, 2013;
originally announced July 2013.
-
The C-4 Dark Matter Experiment
Authors:
R. M. Bonicalzi,
J. I. Collar,
J. Colaresi,
J. E. Fast,
N. E. Fields,
E. S. Fuller,
M. Hai,
T. W. Hossbach,
M. S. Kos,
J. L. Orrell,
C. T. Overman,
D. J. Reid,
B. A. VanDevender,
C. Wiseman,
K. M. Yocum
Abstract:
We describe the experimental design of C-4, an expansion of the CoGeNT dark matter search to four identical detectors each approximately three times the mass of the p-type point contact germanium diode presently taking data at the Soudan Underground Laboratory. Expected reductions of radioactive backgrounds and energy threshold are discussed, including an estimate of the additional sensitivity to…
▽ More
We describe the experimental design of C-4, an expansion of the CoGeNT dark matter search to four identical detectors each approximately three times the mass of the p-type point contact germanium diode presently taking data at the Soudan Underground Laboratory. Expected reductions of radioactive backgrounds and energy threshold are discussed, including an estimate of the additional sensitivity to low-mass dark matter candidates to be obtained with this search.
△ Less
Submitted 7 February, 2013; v1 submitted 23 October, 2012;
originally announced October 2012.