-
Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China Jinping Underground Laboratory
Authors:
S. K. Liu,
Q. Yue,
K. J. Kang,
J. P. Cheng,
H. T. Wong,
Y. J. Li,
S. T. Lin,
J. P. Chang,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
H. X. Huang,
T. R. Huang,
H. Jiang,
H. B. Li,
J. M. Li,
J. Li,
J. Li
, et al. (51 additional authors not shown)
Abstract:
The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is deriv…
▽ More
The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.
△ Less
Submitted 1 August, 2014; v1 submitted 21 March, 2014;
originally announced March 2014.
-
First results on low-mass WIMP from the CDEX-1 experiment at the China Jinping underground Laboratory
Authors:
W. Zhao,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
S. T. Lin,
Y. Bai,
Y. Bi,
J. P. Chang,
N. Chen,
N. Chen,
Q. H. Chen,
Y. H. Chen,
Y. C. Chuang,
Z. Deng,
C. Du,
Q. Du,
H. Gong,
X. Q. Hao,
H. J. He,
Q. J. He,
X. H. Hu,
H. X. Huang,
T. R. Huang,
H. Jiang
, et al. (54 additional authors not shown)
Abstract:
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{…
▽ More
The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.
△ Less
Submitted 8 August, 2013; v1 submitted 18 June, 2013;
originally announced June 2013.
-
Measurement of Cosmic Ray Flux in China JinPing underground Laboratory
Authors:
Yu-Cheng Wu,
Xi-Qing Hao,
Qian Yue,
Yuan-Jing LI,
Jian-Ping Cheng,
Ke-Jun Kang,
Yun-Hua Chen,
Jin Li,
Jian-Min Li,
Yu-Lan Li,
Shu-Kui Liu,
Hao Ma,
Jin-Bao Ren,
Man-Bin Shen,
Ji-Min Wang,
Shi-Yong Wu,
Tao Xue,
Nan YI,
Xiong-Hui Zeng,
Zhi Zeng,
Zhong-Hua Zhu
Abstract:
China JinPing underground Laboratory (CJPL) is the deepest underground laboratory presently running in the world. In such a deep underground laboratory, the cosmic ray flux is a very important and necessary parameter for rare event experiments. A plastic scintillator telescope system has been set up to measure the cosmic ray flux. The performance of the telescope system has been studied using the…
▽ More
China JinPing underground Laboratory (CJPL) is the deepest underground laboratory presently running in the world. In such a deep underground laboratory, the cosmic ray flux is a very important and necessary parameter for rare event experiments. A plastic scintillator telescope system has been set up to measure the cosmic ray flux. The performance of the telescope system has been studied using the cosmic ray on the ground laboratory near CJPL. Based on the underground experimental data taken from November 2010 to December 2011 in CJPL, which has effective live time of 171 days, the cosmic ray muon flux in CJPL is measured to be (2.0+-0.4)*10^(-10)/(cm^2)/(s). The ultra-low cosmic ray background guarantees CJPL's ideal environment for dark matter experiment.
△ Less
Submitted 4 May, 2013;
originally announced May 2013.
-
The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches
Authors:
Ke-Jun Kang,
Qian Yue,
Yu-Cheng Wu,
Jian-Ping Cheng,
Yuan-Jing Li,
Yang Bai,
Yong Bi,
Jian-Ping Chang,
Nan Chen,
Ning Chen,
Qing-Hao Chen,
Yun-Hua Chen,
You-Chun Chuang,
Zhi Dend,
Qiang Du,
Hui Gong,
Xi-Qing Hao,
Qing-Ju He,
Xin-Hui Hu,
Han-Xiong Huang,
Teng-Rui Huang,
Hao Jiang,
Hau-Bin Li,
Jian-Min Li,
Jin Li
, et al. (51 additional authors not shown)
Abstract:
The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-conta…
▽ More
The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.
△ Less
Submitted 2 May, 2013;
originally announced May 2013.
-
Introduction of the CDEX experiment
Authors:
Ke-Jun Kang,
Jian-Ping Cheng,
Jin Li,
Yuan-Jing Li,
Qian Yue,
Yang Bai,
Yong Bi,
Jian-Ping Chang,
Nan Chen,
Ning Chen,
Qing-Hao Chen,
Yun-Hua Chen,
Zhi Deng,
Qiang Du,
Hui Gong,
Xi-Qing Hao,
Hong-Jian He,
Qing-Ju He,
Xin-Hui Hu,
Han-Xiong Huang,
Hao Jiang,
Jian-Min Li,
Xia Li,
Xin-Ying Li,
Xue-Qian Li
, et al. (39 additional authors not shown)
Abstract:
Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China Jin-Ping underground lab…
▽ More
Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China Jin-Ping underground laboratory CJPL is the deepest underground lab in the world and provides a very promising environment for direct observation of dark matter. The China Dark Matter Experiment (CDEX) experiment is going to directly detect the WIMP flux with high sensitivity in the low mass region. Both CJPL and CDEX have achieved a remarkable progress in recent two years. The CDEX employs a point-contact germanium semi-conductor detector PCGe whose detection threshold is less than 300 eV. We report the measurement results of Muon flux, monitoring of radioactivity and Radon concentration carried out in CJPL, as well describe the structure and performance of the 1 kg PCGe detector CDEX-1 and 10kg detector array CDEX-10 including the detectors, electronics, shielding and cooling systems. Finally we discuss the physics goals of the CDEX-1, CDEX-10 and the future CDEX-1T detectors.
△ Less
Submitted 3 March, 2013;
originally announced March 2013.