-
In-Depth Modeling of Tilt-To-Length Coupling in LISA's Interferometers and TDI Michelson Observables
Authors:
Gudrun Wanner,
Sweta Shah,
Martin Staab,
Henry Wegener,
Sarah Paczkowski
Abstract:
We present first-order models for tilt-to-length (TTL) coupling in LISA, both for the individual interferometers as well as in the time-delay interferometry (TDI) Michelson observables. These models include the noise contributions from angular and lateral jitter coupling of the six test masses, six movable optical subassemblies (MOSAs), and three spacecraft. We briefly discuss which terms are cons…
▽ More
We present first-order models for tilt-to-length (TTL) coupling in LISA, both for the individual interferometers as well as in the time-delay interferometry (TDI) Michelson observables. These models include the noise contributions from angular and lateral jitter coupling of the six test masses, six movable optical subassemblies (MOSAs), and three spacecraft. We briefly discuss which terms are considered to be dominant and reduce the TTL model for the second-generation TDI Michelson X observable to these primary noise contributions to estimate the resulting noise level. We show that the expected TTL noise will initially violate the entire mission displacement noise budget, resulting in the known necessity to fit and subtract TTL noise in data post-processing. By comparing the noise levels for different assumptions prior to subtraction, we show why noise mitigation by realignment prior to subtraction is favorable. We then discuss that the TTL coupling in the individual interferometers will have noise contributions that will not be present in the TDI observables. Models for TTL coupling noise in TDI and in the individual interferometers are therefore different, and commonly made assumptions are valid as such only for TDI but not for the individual interferometers. Finally, we analyze what implications can be drawn from the presented models for the subsequent fit-and-subtraction in post-processing. We show that noise contributions from the test mass and inter-satellite interferometers are indistinguishable, such that only the combined coefficients can be fit and used for subtraction. However, a distinction is considered not necessary. Additionally, we show a correlation between coefficients for transmitter and receiver jitter couplings in each individual TDI Michelson observable. This full correlation can be resolved by using all three Michelson observables for fitting the TTL coefficients.
△ Less
Submitted 6 June, 2024; v1 submitted 11 March, 2024;
originally announced March 2024.
-
Scale Factor Determination for the GRACE-Follow On Laser Ranging Interferometer including Thermal Coupling
Authors:
Malte Misfeldt,
Vitali Müller,
Laura Müller,
Henry Wegener,
Gerhard Heinzel
Abstract:
The GRACE Follow-On satellites carry the very first inter-spacecraft Laser Ranging Interferometer (LRI). After more than four years in orbit, the LRI outperforms the sensitivity of the conventional Microwave Instrument (MWI). However, in the current data processing scheme, the LRI product still needs the MWI data to determine the unknown absolute laser frequency, representing the ruler for convert…
▽ More
The GRACE Follow-On satellites carry the very first inter-spacecraft Laser Ranging Interferometer (LRI). After more than four years in orbit, the LRI outperforms the sensitivity of the conventional Microwave Instrument (MWI). However, in the current data processing scheme, the LRI product still needs the MWI data to determine the unknown absolute laser frequency, representing the ruler for converting the raw phase measurements into a physical displacement in meters. In this paper, we derive formulas for precisely performing that conversion from the phase measurement into a range, accounting for a varying carrier frequency. Furthermore, the dominant errors due to knowledge uncertainty of the carrier frequency as well as uncorrected time biases are derived. In the second part, we address the dependency of the LRI on the MWI in the currently employed cross-calibration scheme and present three different models for the LRI laser frequency, two of which are largely independent of the MWI. Furthermore, we analyze the contribution of thermal variations on the scale factor estimates and the LRI-MWI residuals. A linear model called Thermal Coupling (TC) is derived that significantly reduces the differences between LRI and MWI to a level where the MWI observations limit the comparison.
△ Less
Submitted 21 November, 2022; v1 submitted 23 July, 2022;
originally announced July 2022.
-
On orbit performance of the GRACE Follow-On Laser Ranging Interferometer
Authors:
Klaus Abich,
Claus Braxmaier,
Martin Gohlke,
Josep Sanjuan,
Alexander Abramovici,
Brian Bachman Okihiro,
David C. Barr,
Maxime P. Bize,
Michael J. Burke,
Ken C. Clark,
Glenn de Vine,
Jeffrey A. Dickson,
Serge Dubovitsky,
William M. Folkner,
Samuel Francis,
Martin S. Gilbert,
Mark Katsumura,
William Klipstein,
Kameron Larsen,
Carl Christian Liebe,
Jehhal Liu,
Kirk McKenzie,
Phillip R. Morton,
Alexander T. Murray,
Don J. Nguyen
, et al. (58 additional authors not shown)
Abstract:
The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and Climate Experiment (GRACE) Follow-On mission has provided the first laser interferometric range measurements between remote spacecraft, separated by approximately 220 km. Autonomous controls that lock the laser frequency to a cavity reference and establish the 5 degree of freedom two-way laser link between remote spacecr…
▽ More
The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and Climate Experiment (GRACE) Follow-On mission has provided the first laser interferometric range measurements between remote spacecraft, separated by approximately 220 km. Autonomous controls that lock the laser frequency to a cavity reference and establish the 5 degree of freedom two-way laser link between remote spacecraft succeeded on the first attempt. Active beam pointing based on differential wavefront sensing compensates spacecraft attitude fluctuations. The LRI has operated continuously without breaks in phase tracking for more than 50 days, and has shown biased range measurements similar to the primary ranging instrument based on microwaves, but with much less noise at a level of $1\,{\rm nm}/\sqrt{\rm Hz}$ at Fourier frequencies above 100 mHz.
△ Less
Submitted 28 June, 2019;
originally announced July 2019.