-
CCAT-prime: RFSoC Based Readout for Frequency Multiplexed Kinetic Inductance Detectors
Authors:
Adrian K. Sinclair,
Ryan C. Stephenson,
Cody A. Roberson,
Eric L. Weeks,
James Burgoyne,
Anthony I. Huber,
Philip M. Mauskopf,
Scott C. Chapman,
Jason E. Austermann,
Steve K. Choi,
Cody J. Duell,
Michel Fich,
Christopher E. Groppi,
Zachary Huber,
Michael D. Niemack,
Thomas Nikola,
Kayla M. Rossi,
Adhitya Sriram,
Gordon J. Stacey,
Erik Szakiel,
Joel Tsuchitori,
Eve M. Vavagiakis,
Jordan D. Wheeler,
the CCAT-prime collaboration
Abstract:
The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every ca…
▽ More
The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every category of size, weight, power, cost, and bandwidth over the previous generation readout systems. We describe a baseline firmware design which can read out four independent RF networks each with 500 MHz of bandwidth and 1000 detectors for ~30 W. The overall readout architecture is a combination of hardware, gateware/firmware, software, and network design. The requirements of the readout are driven by the 850 GHz instrument module of the 7-module Prime-Cam instrument. These requirements along with other constraints which have led to critical design choices are highlighted. Preliminary measurements of the system phase noise and dynamic range are presented.
△ Less
Submitted 15 August, 2022;
originally announced August 2022.
-
Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors
Authors:
Trevor M. Oxholm,
Eric R. Switzer,
Emily M. Barrentine,
Thomas Essinger-Hileman,
James P. Hays-Wehle,
Philip D. Mauskopf,
Omid Noroozian,
Maryam Rahmani,
Adrian K. Sinclair,
Ryan Stephenson,
Thomas R. Stevenson,
Peter T. Timbie,
Carolyn Volpert,
Eric Weeks
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For th…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For these reasons, MKIDs were chosen for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), a balloon-borne telescope targeting nearly background-limited performance in a high-altitude atmospheric environment from 420-540 GHz. We describe MKID optimization in the specific context of EXCLAIM and provide general results that apply to broader applications. Extending the established approach of tone frequency tracking, we show that readout power optimization enables significant, further improvement in dynamic range.
△ Less
Submitted 28 April, 2022;
originally announced April 2022.
-
CCAT-prime: Characterization of the First 280 GHz MKID Array for Prime-Cam
Authors:
Steve K. Choi,
Cody J. Duell,
Jason Austermann,
Nicholas F. Cothard,
Jiansong Gao,
Rodrigo G. Freundt,
Christopher Groppi,
Terry Herter,
Johannes Hubmayr,
Zachary B. Huber,
Ben Keller,
Yaqiong Li,
Phillip Mauskopf,
Michael D. Niemack,
Thomas Nikola,
Kayla Rossi,
Adrian Sinclair,
Gordon J. Stacey,
Eve M. Vavagiakis,
Michael Vissers,
Carole Tucker,
Eric Weeks,
Jordan Wheeler
Abstract:
The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microw…
▽ More
The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microwave kinetic inductance detectors (MKIDs) are a natural choice of detector technology for the simplicity in multiplexed readout needed for large format arrays at these high frequencies. We present here the initial lab characterization of the feedhorn-coupled 280 GHz polarimetric MKID array, and outline the plans for the subsequent MKID arrays and the development of the testbed to characterize them.
△ Less
Submitted 10 August, 2022; v1 submitted 1 November, 2021;
originally announced November 2021.
-
The design of the Ali CMB Polarization Telescope receiver
Authors:
Maria Salatino,
Jason E. Austermann,
Keith L. Thompson,
Peter A. R. Ade,
Xiran Bai,
James A. Beall,
Dan T. Becker,
Yifu Cai,
Zhi Chang,
Ding Chen,
Pisin Chen,
Jake Connors,
Jacques Delabrouille,
Bradley Dober,
Shannon M. Duff,
Guanhua Gao,
Shamik Ghosh,
Richard C. Givhan,
Gene C. Hilton,
Bin Hu,
Johannes Hubmayr,
Ethan D. Karpel,
Chao-Lin Kuo,
Hong Li,
Mingzhe Li
, et al. (50 additional authors not shown)
Abstract:
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polariza…
▽ More
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.
△ Less
Submitted 23 January, 2021;
originally announced January 2021.