System performance of a TDM test-bed with long flex harness towards the new X-IFU FPA-DM
Authors:
D. Vaccaro,
M. de Wit,
J. van der Kuur,
L. Gottardi,
K. Ravensberg,
E. Taralli,
J. Adams,
S. R. Bandler,
J. A. Chervenak,
W. B. Doriese,
M. Durkin,
C. Reintsema,
K. Sakai,
S. J. Smith,
N. A. Wakeham,
B. Jackson,
P. Khosropanah,
J. R. Gao,
J. W. A. den Herder,
P. Roelfsema
Abstract:
SRON (Netherlands Institute for Space Research) is developing the Focal Plane Assembly (FPA) for Athena X-IFU, whose Demonstration Model (DM) will use for the first time a time domain multiplexing (TDM)-based readout system for the on-board transition-edge sensors (TES). We report on the characterization activities on a TDM setup provided by NASA Goddard Space Flight Center (GSFC) and National Ins…
▽ More
SRON (Netherlands Institute for Space Research) is developing the Focal Plane Assembly (FPA) for Athena X-IFU, whose Demonstration Model (DM) will use for the first time a time domain multiplexing (TDM)-based readout system for the on-board transition-edge sensors (TES). We report on the characterization activities on a TDM setup provided by NASA Goddard Space Flight Center (GSFC) and National Institute for Standards and Technology (NIST) and tested in SRON cryogenic test facilities. The goal of these activities is to study the impact of the longer harness, closer to X-IFU specs, in a different EMI environment and switching from a single-ended to a differential readout scheme. In this contribution we describe the advancement in the debugging of the system in the SRON cryostat, which led to the demonstration of the nominal spectral performance of 2.8 eV at 5.9~keV with 16-row multiplexing, as well as an outlook for the future endeavours for the TDM readout integration on X-IFU's FPA-DM at SRON.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
A 50 mK test bench for demonstration of the readout chain of Athena/X-IFU
Authors:
Florent Castellani,
Sophie Beaumont,
François Pajot,
Gilles Roudil,
Joseph Adams,
Simon Bandler,
James Chervenak,
Christophe Daniel,
Edward V Denison,
W Bertrand Doriese,
Michel Dupieux,
Malcolm Durkin,
Hervé Geoffray,
Gene C Hilton,
David Murat,
Yann Parot,
Philippe Peille,
Damien Prêle,
Laurent Ravera,
Carl D Reintsema,
Kazuhiro Sakai,
Robert W Stevens,
Joel N Ullom,
Leila R Vale,
Nicholas Wakeham
Abstract:
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Tra…
▽ More
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electronics by NIST, the cold amplifier by VTT, the WFEE (Warm Front-End Electronics) by APC, the DRE (Digital Readout Electronics) by IRAP and a focal plane assembly by SRON. To assess the operation of the complete readout chain of the X-IFU, a 50 mK test bench based on a kilo-pixel array of microcalorimeters from NASA/GSFC has been developed at IRAP in collaboration with CNES. Validation of the test bench has been performed with an intermediate detection chain entirely from NIST and Goddard. Next planned activities include the integration of DRE and WFEE prototypes in order to perform an end-to-end demonstration of a complete X-IFU detection chain.
△ Less
Submitted 9 September, 2022;
originally announced September 2022.
-
The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase
Authors:
Didier Barret,
Vincent Albouys,
Jan-Willem den Herder,
Luigi Piro,
Massimo Cappi,
Juhani Huovelin,
Richard Kelley,
J. Miguel Mas-Hesse,
Stéphane Paltani,
Gregor Rauw,
Agata Rozanska,
Jiri Svoboda,
Joern Wilms,
Noriko Yamasaki,
Marc Audard,
Simon Bandler,
Marco Barbera,
Xavier Barcons,
Enrico Bozzo,
Maria Teresa Ceballos,
Ivan Charles,
Elisa Costantini,
Thomas Dauser,
Anne Decourchelle,
Lionel Duband
, et al. (274 additional authors not shown)
Abstract:
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide sp…
▽ More
The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).
△ Less
Submitted 28 November, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)
Authors:
M. D'Andrea,
K. Ravensberg,
A. Argan,
D. Brienza,
S. Lotti,
C. Macculi,
G. Minervini,
L. Piro,
G. Torrioli,
F. Chiarello,
L. Ferrari Barusso,
M. Biasotti,
G. Gallucci,
F. Gatti,
M. Rigano,
H. Akamatsu,
J. Dercksen,
L. Gottardi,
F. de Groote,
R. den Hartog,
J. -W. den Herder,
R. Hoogeveen,
B. Jackson,
A. McCalden,
S. Rosman
, et al. (6 additional authors not shown)
Abstract:
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonst…
▽ More
The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
A test platform for the detection and readout chain for the Athena X-IFU
Authors:
Gabriele Betancourt-Martinez,
François Pajot,
Sophie Beaumont,
Gilles Roudil,
Joseph Adams,
Hiroki Akamatsu,
Simon Bandler,
Bernard Bertrand,
Marcel Bruijn,
Florent Castellani,
Edoardo Cucchetti,
William Doriese,
Michel Dupieux,
Hervé Geoffray,
Luciano Gottardi,
Brian Jackson,
Jan van der Kuur,
Mikko Kiviranta,
Antoine Miniussi,
Phillipe Peille,
Kevin Ravensberg,
Laurent Ravera,
Carl Reintsema,
Kazuhiro Sakai,
Stephen Smith
, et al. (4 additional authors not shown)
Abstract:
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of th…
▽ More
We present a test platform for the Athena X-IFU detection chain, which will serve as the first demonstration of the representative end-to-end detection and readout chain for the X-IFU, using prototypes of the future flight electronics and currently available subsystems. This test bench, housed in a commercial two-stage ADR cryostat, includes a focal plane array placed at the 50 mK cold stage of the ADR with a kilopixel array of transition-edge sensor microcalorimeter spectrometers and associated cold readout electronics. Prototype room temperature electronics for the X-IFU provide the readout, and will evolve over time to become more representative of the X-IFU mission baseline. The test bench yields critical feedback on subsystem designs and interfaces, in particular the warm readout electronics, and will provide an in-house detection system for continued testing and development of the warm readout electronics and for the validation of X-ray calibration sources. In this paper, we describe the test bench subsystems and design, characterization of the cryostat, and current status of the project.
△ Less
Submitted 7 July, 2021;
originally announced July 2021.
-
Progress in the development of frequency domain multiplexing for the X-ray Integral Field Unit on board the Athena mission
Authors:
H. Akamatsu,
L. Gottardi,
J. van der Kuur,
C. P. de Vries,
M. P. Bruijn,
J. A. Chervenak,
M. Kiviranta,
A. J. van den Linden,
B. D. Jackson,
A. Miniussi,
K. Ravensberg,
K. Sakai,
S. J. Smith,
N. Wakeham
Abstract:
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provi…
▽ More
Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC bias) at MHz frequencies. Using high-quality factor LC filters and room temperature electronics developed at SRON and low-noise two-stage SQUID amplifiers provided by VTT, we have recently demonstrated good performance with the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have achieved a performance requested for the demonstration model (DM) with the single pixel AC bias ($ΔE=$1.8 eV) and 9 pixel multiplexing ($ΔE=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an average energy resolution of 3.3 eV, which is limited by non-fundamental issues related to FDM readout in our lab setup.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
Towards 100,000-pixel microcalorimeter arrays using multi-absorber transition-edge sensors
Authors:
S. J. Smith,
J. S. Adams,
S. R. Bandler,
S. Beaumont,
J. A. Chervenak,
A. M. Datesman,
F. M. Finkbeiner,
R. Hummatov,
R. L. Kelly,
C. A. Kilbourne,
A. R. Miniussi,
F. S. Porter,
J. E. Sadleir,
K. Sakai,
N. A. Wakeham,
E. J. Wassell,
M. C. Witthoeft,
K. Ryu
Abstract:
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the pulse shape. With some trade-off in performance, hydras enable very large format arrays without the prohibitive increase in bias and read-out components associate…
▽ More
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the pulse shape. With some trade-off in performance, hydras enable very large format arrays without the prohibitive increase in bias and read-out components associated with arrays of individual TESs. Hydras are under development for the next generation of space telescope such as Lynx. Lynx is a NASA concept under study that will combine a < 1 arcsecond angular resolution optic with 100,000-pixel microcalorimeter array with energy resolution of deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and 50 micron pitch are studied. Arrays incorporate, for the first time, microstrip buried wiring layers of suitable pitch and density required to readout a full-scale Lynx array. The resolution from the coadded energy histogram including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at an energy of 1.5 keV for the 25 micron and 50 micron absorber designs respectively. Position discrimination is demonstrated from parameterization of the rise-time.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.