-
Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (115 additional authors not shown)
Abstract:
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, c…
▽ More
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$σ$ (5$σ$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
△ Less
Submitted 17 November, 2020; v1 submitted 17 July, 2020;
originally announced July 2020.
-
Search for Electronic Recoil Event Rate Modulation with 4 Years of XENON100 Data
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Butikofer,
J. Calven,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (89 additional authors not shown)
Abstract:
We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 years, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. Ther…
▽ More
We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 years, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. There is a weak modulation signature at a period of $431^{+16}_{-14}$ days in the low energy region of $(2.0-5.8)$ keV in the single scatter event sample, with a global significance of $1.9\,σ$, however no other more significant modulation is observed. The expected annual modulation of a dark matter signal is not compatible with this result. Single scatter events in the low energy region are thus used to exclude the DAMA/LIBRA annual modulation as being due to dark matter electron interactions via axial vector coupling at $5.7\,σ$.
△ Less
Submitted 3 January, 2017;
originally announced January 2017.
-
Physics reach of the XENON1T dark matter experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
L. Arazi,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
T. Berger,
P. Breur,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon
, et al. (91 additional authors not shown)
Abstract:
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and (…
▽ More
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_χ$=$50$ GeV/$c^2$.
△ Less
Submitted 15 April, 2016; v1 submitted 23 December, 2015;
originally announced December 2015.
-
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
Authors:
The XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
M. Anthony,
L. Arazi,
K. Arisaka,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Coderre,
A. P. Colijn,
H. Contreras
, et al. (77 additional authors not shown)
Abstract:
We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to ide…
▽ More
We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
△ Less
Submitted 28 July, 2015;
originally announced July 2015.
-
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
Authors:
The XENON Collaboration,
E. Aprile,
F. Agostini,
M. Alfonsi,
L. Arazi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Coderre,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau
, et al. (76 additional authors not shown)
Abstract:
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic re…
▽ More
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2 GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4 sigma confidence level, mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
△ Less
Submitted 28 July, 2015;
originally announced July 2015.
-
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
Authors:
The XENON Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (52 additional authors not shown)
Abstract:
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the ratio…
▽ More
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.
△ Less
Submitted 28 August, 2012;
originally announced August 2012.