-
Axion Dark Matter eXperiment: Run 1A Analysis Details
Authors:
C. Boutan,
B. H. LaRoque,
E. Lentz,
N. S. Oblath,
M. S. Taubman,
J. Tedeschi,
J. Yang,
A. M. Jones,
T. Braine,
N. Crisosto,
L. J Rosenberg,
G. Rybka,
D. Will,
D. Zhang,
S. Kimes,
R. Ottens,
C. Bartram,
D. Bowring,
R. Cervantes,
A. S. Chou,
S. Knirck,
D. V. Mitchell,
A. Sonnenschein,
W. Wester,
R. Khatiwada
, et al. (28 additional authors not shown)
Abstract:
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower…
▽ More
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
C. Goodman,
M. Guzzetti,
C. Hanretty,
S. Lee,
G. Leum,
L. J. Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
M. H. Awida,
D. Bowring,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
R. Khatiwada,
J. Brodsky,
G. Carosi,
L. D. Duffy
, et al. (31 additional authors not shown)
Abstract:
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion se…
▽ More
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
First Results from a Broadband Search for Dark Photon Dark Matter in the $44$ to $52\,μ$eV range with a coaxial dish antenna
Authors:
Stefan Knirck,
Gabe Hoshino,
Mohamed H. Awida,
Gustavo I. Cancelo,
Martin Di Federico,
Benjamin Knepper,
Alex Lapuente,
Mira Littmann,
David W. Miller,
Donald V. Mitchell,
Derrick Rodriguez,
Mark K. Ruschman,
Matthew A. Sawtell,
Leandro Stefanazzi,
Andrew Sonnenschein,
Gary W. Teafoe,
Daniel Bowring,
G. Carosi,
Aaron Chou,
Clarence L. Chang,
Kristin Dona,
Rakshya Khatiwada,
Noah A. Kurinsky,
Jesse Liu,
Cristián Pena
, et al. (3 additional authors not shown)
Abstract:
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are re…
▽ More
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are read out with a low-noise receiver system. A first data taking run with 24 days of data does not show evidence for dark photon dark matter in this mass range, excluding dark photon - photon mixing parameters $χ\gtrsim 10^{-12}$ in this range at 90% confidence level. This surpasses existing constraints by about two orders of magnitude and is the most stringent bound on dark photons in this range below 49 $μ$eV.
△ Less
Submitted 3 May, 2024; v1 submitted 20 October, 2023;
originally announced October 2023.
-
Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers
Authors:
E. Adams,
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas,
A. García Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. Jin
, et al. (30 additional authors not shown)
Abstract:
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been dev…
▽ More
PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.
△ Less
Submitted 21 January, 2023;
originally announced January 2023.
-
Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
F. Girard,
G. Giroux,
O. Harris,
E. W. Hoppe,
C. M. Jackson,
M. Jin,
C. B. Krauss
, et al. (32 additional authors not shown)
Abstract:
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct…
▽ More
The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.
△ Less
Submitted 7 November, 2022; v1 submitted 11 May, 2022;
originally announced May 2022.
-
Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber
Authors:
B. Ali,
I. J. Arnquist,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
C. J. Chen,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. Cripe,
M. Crisler,
C. E. Dahl,
M. Das,
D. Durnford,
S. Fallows,
J. Farine,
R. Filgas,
A. García-Viltres,
G. Giroux,
O. Harris,
T. Hillier,
E. W. Hoppe,
C. M. Jackson,
M. Jin
, et al. (30 additional authors not shown)
Abstract:
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact…
▽ More
Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.
△ Less
Submitted 21 April, 2022;
originally announced April 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
Broadband solenoidal haloscope for terahertz axion detection
Authors:
Jesse Liu,
Kristin Dona,
Gabe Hoshino,
Stefan Knirck,
Noah Kurinsky,
Matthew Malaker,
David W. Miller,
Andrew Sonnenschein,
Mohamed H. Awida,
Peter S. Barry,
Karl K. Berggren,
Daniel Bowring,
Gianpaolo Carosi,
Clarence Chang,
Aaron Chou,
Rakshya Khatiwada,
Samantha Lewis,
Juliang Li,
Sae Woo Nam,
Omid Noroozian,
Tony X. Zhou
Abstract:
We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10$^{-3}$, 1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry en…
▽ More
We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the [10$^{-3}$, 1] eV ([0.24, 240] THz) mass range. BREAD proposes a cylindrical metal barrel to convert dark matter into photons, which a novel parabolic reflector design focuses onto a photosensor. This unique geometry enables enclosure in standard cryostats and high-field solenoids, overcoming limitations of current dish antennas. A pilot 0.7 m$^{2}$ barrel experiment planned at Fermilab is projected to surpass existing dark photon coupling constraints by over a decade with one-day runtime. Axion sensitivity requires $<10^{-20}$ W/$\sqrt{\textrm{Hz}}$ sensor noise equivalent power with a 10 T solenoid and 10 m$^{2}$ barrel. We project BREAD sensitivity for various sensor technologies and discuss future prospects.
△ Less
Submitted 24 March, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
S. Jois,
P. Sikivie
, et al. (26 additional authors not shown)
Abstract:
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search.…
▽ More
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
△ Less
Submitted 15 October, 2021;
originally announced October 2021.
-
Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
E. Burns,
R. Cervantes,
N. Crisosto,
N. Du,
H. Korandla,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason
, et al. (27 additional authors not shown)
Abstract:
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temp…
▽ More
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
△ Less
Submitted 29 December, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Axion Dark Matter eXperiment: Run 1B Analysis Details
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
M. Goryachev,
B. McAllister,
M. E. Tobar,
C. Boutan,
M. Jones,
B. H. Laroque,
N. S. Oblath
, et al. (23 additional authors not shown)
Abstract:
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire fre…
▽ More
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for Run 1B, motivating analysis choices informed by details specific to this run.
△ Less
Submitted 13 October, 2020;
originally announced October 2020.
-
Axion Dark Matter eXperiment: Detailed Design and Operations
Authors:
R. Khatiwada,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
D. V. Mitchell,
T. Braine,
C. Bartram,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Will,
G. Carosi,
N. Woollett,
S. Durham,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath
, et al. (26 additional authors not shown)
Abstract:
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technolog…
▽ More
Axion Dark Matter eXperiment (ADMX) ultra low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the $2.66$ to $3.1$ $μ$eV mass range with Dine-Fischler-Srednicki-Zhitnisky (DFSZ) sensitivity Ref. [1,2]. Therefore, it is the most sensitive axion search experiment to date in this mass range. We discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as state-of-the-art quantum limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable Microstrip Superconducting Quantum Interference Device (SQUID) Amplifier (MSA), in Run 1A, and a Josephson Parametric Amplifier (JPA), in Run 1B, along with novel analysis tools that characterize the system noise temperature.
△ Less
Submitted 30 September, 2020;
originally announced October 2020.
-
Extended Search for the Invisible Axion with the Axion Dark Matter Experiment
Authors:
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
S. Kimes,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
R. Bradley,
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
M. S. Taubman,
J. Clarke,
A. Dove,
A. Eddins
, et al. (17 additional authors not shown)
Abstract:
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode c…
▽ More
This paper reports on a cavity haloscope search for dark matter axions in the galactic halo in the mass range $2.81$-$3.31$ $μeV$. This search excludes the full range of axion-photon coupling values predicted in benchmark models of the invisible axion that solve the strong CP problem of quantum chromodynamics, and marks the first time a haloscope search has been able to search for axions at mode crossings using an alternate cavity configuration. Unprecedented sensitivity in this higher mass range is achieved by deploying an ultra low-noise Josephson parametric amplifier as the first stage signal amplifier.
△ Less
Submitted 1 November, 2019; v1 submitted 18 October, 2019;
originally announced October 2019.
-
Velocity independent constraints on spin-dependent DM-nucleon interactions from IceCube and PICO
Authors:
IceCube Collaboration,
M. G. Aartsen,
M. Ackermann,
J. Adams,
J. A. Aguilar,
M. Ahlers,
M. Ahrens,
C. Alispach,
K. Andeen,
T. Anderson,
I. Ansseau,
G. Anton,
C. Argüelles,
J. Auffenberg,
S. Axani,
P. Backes,
H. Bagherpour,
X. Bai,
A. Balagopal V.,
A. Barbano,
S. W. Barwick,
B. Bastian,
V. Baum,
S. Baur,
R. Bay
, et al. (398 additional authors not shown)
Abstract:
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from…
▽ More
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity distribution for dark matter (DM) particles in the Galaxy, the most stringent current constraints on their spin-dependent scattering cross-section with nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$ superheated bubble chamber experiments. The former is sensitive to high energy neutrinos from the self-annihilation of DM particles captured in the Sun, while the latter looks for nuclear recoil events from DM scattering off nucleons. Although slower DM particles are more likely to be captured by the Sun, the faster ones are more likely to be detected by PICO. Recent N-body simulations suggest significant deviations from the SHM for the smooth halo component of the DM, while observations hint at a dominant fraction of the local DM being in substructures. We use the method of Ferrer et al. (2015) to exploit the complementarity between the two approaches and derive conservative constraints on DM-nucleon scattering. Our results constrain $σ_{\mathrm{SD}} \lesssim 3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at $\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $τ^+ τ^-$ ($b\bar{b}$) with a local density of $ρ_{\mathrm{DM}} = 0.3~\mathrm{ GeV/cm}^3$. The constraints scale inversely with $ρ_{\mathrm{DM}}$ and are independent of the DM velocity distribution.
△ Less
Submitted 25 May, 2020; v1 submitted 29 July, 2019;
originally announced July 2019.
-
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
S. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
R. Filgas
, et al. (54 additional authors not shown)
Abstract:
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by…
▽ More
The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.
△ Less
Submitted 25 November, 2020; v1 submitted 29 May, 2019;
originally announced May 2019.
-
Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
M. Bressler,
B. Broerman,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
C. B. Coutu,
C. Cowles,
M. Crisler,
G. Crowder,
N. A. Cruz-Venegas,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas
, et al. (47 additional authors not shown)
Abstract:
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total backgr…
▽ More
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.
△ Less
Submitted 11 February, 2019;
originally announced February 2019.
-
Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter
Authors:
C. Boutan,
M. Jones,
B. H. LaRoque,
N. S. Oblath,
R. Cervantes,
N. Du,
N. Force,
S. Kimes,
R. Ottens,
L. J. Rosenberg,
G. Rybka,
J. Yang,
G. Carosi,
N. Woollett,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
R. Bradley,
E. J. Daw,
A. Agrawal,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley
, et al. (9 additional authors not shown)
Abstract:
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, highe…
▽ More
The $μ$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
A Search for Invisible Axion Dark Matter with the Axion Dark Matter Experiment
Authors:
N. Du,
N. Force,
R. Khatiwada,
E. Lentz,
R. Ottens,
L. J Rosenberg,
G. Rybka,
G. Carosi,
N. Woolett,
D. Bowring,
A. S. Chou,
A. Sonnenschein,
W. Wester,
C. Boutan,
N. S. Oblath,
R. Bradley,
E. J. Daw,
A. V. Dixit,
J. Clarke,
S. R. O'Kelley,
N. Crisosto,
J. R. Gleason,
S. Jois,
P. Sikivie,
I. Stern
, et al. (3 additional authors not shown)
Abstract:
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from t…
▽ More
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $μ$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sensitivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultra-low-noise SQUID amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.
△ Less
Submitted 17 April, 2018; v1 submitted 16 April, 2018;
originally announced April 2018.
-
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Authors:
Marco Battaglieri,
Alberto Belloni,
Aaron Chou,
Priscilla Cushman,
Bertrand Echenard,
Rouven Essig,
Juan Estrada,
Jonathan L. Feng,
Brenna Flaugher,
Patrick J. Fox,
Peter Graham,
Carter Hall,
Roni Harnik,
JoAnne Hewett,
Joseph Incandela,
Eder Izaguirre,
Daniel McKinsey,
Matthew Pyle,
Natalie Roe,
Gray Rybka,
Pierre Sikivie,
Tim M. P. Tait,
Natalia Toro,
Richard Van De Water,
Neal Weiner
, et al. (226 additional authors not shown)
Abstract:
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
△ Less
Submitted 14 July, 2017;
originally announced July 2017.
-
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
P. Campion,
G. Cao,
C. J. Chen,
U. Chowdhury,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
G. Crowder,
C. E. Dahl,
M. Das,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
F. Girard
, et al. (37 additional authors not shown)
Abstract:
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less th…
▽ More
New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.
△ Less
Submitted 2 August, 2017; v1 submitted 24 February, 2017;
originally announced February 2017.
-
Improved dark matter search results from PICO-2L Run 2
Authors:
C. Amole,
M. Ardid,
I. J. Arnquist,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
M. Das,
F. Debris,
S. Fallows,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (33 additional authors not shown)
Abstract:
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nu…
▽ More
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
△ Less
Submitted 25 March, 2016; v1 submitted 14 January, 2016;
originally announced January 2016.
-
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
F. Girard,
G. Giroux,
A. Grandison
, et al. (34 additional authors not shown)
Abstract:
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays…
▽ More
New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.
△ Less
Submitted 3 March, 2016; v1 submitted 26 October, 2015;
originally announced October 2015.
-
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Authors:
C. Amole,
M. Ardid,
D. M. Asner,
D. Baxter,
E. Behnke,
P. Bhattacharjee,
H. Borsodi,
M. Bou-Cabo,
S. J. Brice,
D. Broemmelsiek,
K. Clark,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
S. Daley,
M. Das,
F. Debris,
N. Dhungana,
J. Farine,
I. Felis,
R. Filgas,
M. Fines-Neuschild,
F. Girard,
G. Giroux
, et al. (32 additional authors not shown)
Abstract:
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation o…
▽ More
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 29 June, 2015; v1 submitted 27 February, 2015;
originally announced March 2015.
-
Bubble Chambers for Experiments in Nuclear Astrophysics
Authors:
B. DiGiovine,
D. Henderson,
R. J. Holt,
K. E. Rehm,
R. Raut,
A. Robinson,
A. Sonnenschein,
G. Rusev,
A. P. Tonchev,
C. Ugalde
Abstract:
A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross sections of interest to stellar e…
▽ More
A bubble chamber has been developed to be used as an active target system for low energy nuclear astrophysics experiments. Adopting ideas from dark matter detection with superheated liquids, a detector system compatible with gamma-ray beams has been developed. This detector alleviates some of the limitations encountered in standard measurements of the minute cross sections of interest to stellar environments. While the astrophysically relevant nuclear reaction processes at hydrostatic burning temperatures are dominated by radiative captures, in this experimental scheme we measure the time-reversed processes. Such photodisintegrations allow us to compute the radiative capture cross sections when transitions to excited states of the reaction products are negligible. Due to the transformation of phase space, the photodisintegration cross sections are up to two orders of magnitude higher. The main advantage of the new target-detector system is a density several orders of magnitude higher than conventional gas targets. Also, the detector is virtually insensitive to the gamma-ray beam itself, thus allowing us to detect only the products of the nuclear reaction of interest. The development and the operation as well as the advantages and disadvantages of the bubble chamber are discussed.
△ Less
Submitted 27 January, 2015;
originally announced January 2015.
-
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Authors:
P. Cushman,
C. Galbiati,
D. N. McKinsey,
H. Robertson,
T. M. P. Tait,
D. Bauer,
A. Borgland,
B. Cabrera,
F. Calaprice,
J. Cooley,
T. Empl,
R. Essig,
E. Figueroa-Feliciano,
R. Gaitskell,
S. Golwala,
J. Hall,
R. Hill,
A. Hime,
E. Hoppe,
L. Hsu,
E. Hungerford,
R. Jacobsen,
M. Kelsey,
R. F. Lang,
W. H. Lippincott
, et al. (24 additional authors not shown)
Abstract:
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter spa…
▽ More
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
△ Less
Submitted 3 November, 2013; v1 submitted 30 October, 2013;
originally announced October 2013.
-
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber
Authors:
COUPP Collaboration,
E. Behnke,
T. Benjamin,
S. J. Brice,
D. Broemmelsiek,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
D. Fustin,
J. Hall,
C. Harnish,
I. Levine,
W. H. Lippincott,
T. Moan,
T. Nania,
R. Neilson,
E. Ramberg,
A. E. Robinson,
A. Sonnenschein,
E. Vázquez-Jáuregui,
R. A. Rivera,
L. Uplegger
Abstract:
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel…
▽ More
We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble nucleation theory. This measurement confirms the applicability of CF3I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.
△ Less
Submitted 31 January, 2014; v1 submitted 22 April, 2013;
originally announced April 2013.
-
First determination of an astrophysical cross section with a bubble chamber: the 15N(α,γ)19F reaction
Authors:
C. Ugalde,
B. DiGiovine,
D. Henderson,
R. J. Holt,
K. E. Rehm,
A. Sonnenschein,
A. Robinson,
R. Raut,
G. Rusev,
A. P. Tonchev
Abstract:
We have devised a technique for measuring some of the most important nuclear reactions in stars which we expect to provide considerable improvement over previous experiments. Adapting ideas from dark matter search experiments with bubble chambers, we have found that a superheated liquid is sensitive to recoils produced from γ-rays photodisintegrating the nuclei of the liquid. The main advantage of…
▽ More
We have devised a technique for measuring some of the most important nuclear reactions in stars which we expect to provide considerable improvement over previous experiments. Adapting ideas from dark matter search experiments with bubble chambers, we have found that a superheated liquid is sensitive to recoils produced from γ-rays photodisintegrating the nuclei of the liquid. The main advantage of the new target-detector system is a gain in yield of six orders of magnitude over conventional gas targets due to the higher mass density of liquids. Also, the detector is practically insensitive to the γ-ray beam itself, thus allowing it to detect only the products of the nuclear reaction of interest. The first set of tests of a superheated target with a narrow bandwidth γ-ray beam was completed and the results demonstrate the feasibility of the scheme. The new data are successfully described by an R-matrix model using published resonance parameters. With the increase in luminosity of the next generation γ-ray beam facilities, the measurement of thermonuclear rates in the stellar Gamow window would become possible.
△ Less
Submitted 30 December, 2012;
originally announced December 2012.
-
First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site
Authors:
E. Behnke,
J. Behnke,
S. J. Brice,
D. Broemmelsiek,
J. I. Collar,
A. Conner,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
D. Fustin,
E. Grace,
J. Hall,
M. Hu,
I. Levine,
W. H. Lippincott,
T. Moan,
T. Nania,
E. Ramberg,
A. E. Robinson,
A. Sonnenschein,
M. Szydagis,
E. Vázquez-Jáuregui
Abstract:
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bub…
▽ More
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.
△ Less
Submitted 19 September, 2012; v1 submitted 13 April, 2012;
originally announced April 2012.
-
Direct Search for Low Mass Dark Matter Particles with CCDs
Authors:
J. Barreto,
H. Cease,
H. T. Diehl,
J. Estrada,
B. Flaugher,
N. Harrison,
J. Jones,
B. Kilminster,
J. Molina,
J. Smith,
T. Schwarz,
A. Sonnenschein
Abstract:
A direct dark matter search is performed using fully-depleted high-resistivity CCD detectors . Due to their low electronic readout noise (RMS ~ 7 eV) these devices operate with a very low detection threshold of 40 eV, making the search for dark matter particles with low masses (~ 5 GeV) possible. The results of an engineering run performed in a shallow underground site are presented, demonstrating…
▽ More
A direct dark matter search is performed using fully-depleted high-resistivity CCD detectors . Due to their low electronic readout noise (RMS ~ 7 eV) these devices operate with a very low detection threshold of 40 eV, making the search for dark matter particles with low masses (~ 5 GeV) possible. The results of an engineering run performed in a shallow underground site are presented, demonstrating the potential of this technology in the low mass region.
△ Less
Submitted 2 April, 2012; v1 submitted 25 May, 2011;
originally announced May 2011.
-
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two Liter CF$_3$I Bubble Chamber
Authors:
E. Behnke,
J. Behnke,
S. J. Brice,
D. Broemmelsiek,
J. I. Collar,
P. S. Cooper,
M. Crisler,
C. E. Dahl,
D. Fustin,
J. Hall,
J. H. Hinnefeld,
M. Hu,
I. Levine,
E. Ramberg,
T. Shepherd,
A. Sonnenschein,
M. Szydagis
Abstract:
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during a…
▽ More
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg-day, consistent with a neutron background. This observation provides the strongest direct detection constraint to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$ GeV/c$^{2}$.
△ Less
Submitted 7 March, 2011; v1 submitted 20 August, 2010;
originally announced August 2010.
-
Improved Spin-Dependent WIMP Limits from a Bubble Chamber
Authors:
E. Behnke,
J. I. Collar,
P. S. Cooper,
K. Crum,
M. Crisler,
M. Hu,
I. Levine,
D. Nakazawa,
H. Nguyen,
B. Odom,
E. Ramberg,
J. Rasmussen,
N. Riley,
A. Sonnenschein,
M. Szydagis,
R. Tschirhart
Abstract:
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly…
▽ More
Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly Interacting Massive Particle (WIMP) couplings. An exposure in excess of 250 kg-days is obtained, with a live-time fraction reaching 80%. This illustrates the ability to employ bubble chambers in a new realm, the search for dark matter particles. Improved limits on the spin-dependent WIMP-proton scattering cross section are extracted from this first period. An extreme intrinsic insensitivity to the backgrounds commonly limiting these experiments (a rejection factor for photon-induced electrons of $\sim10^{-10}$) has been measured in operating conditions leading to the detection of low-energy nuclear recoils such as those expected from WIMPs.
△ Less
Submitted 17 April, 2008;
originally announced April 2008.
-
Deep Underground Science and Engineering Lab: S1 Dark Matter Working Group
Authors:
D. S. Akerib,
E. Aprile,
E. A. Baltz,
M. R. Dragowsky,
R. J. Gaitskell,
P. Gondolo,
A. Hime,
C. J. Martoff,
D. -M. Mei,
H. Nelson,
B. Sadoulet,
R. W. Schnee,
A. H. Sonnenschein,
L. E. Strigari
Abstract:
A study of the current status of WIMP dark matter searches has been made in the context of scientific and technical planning for a Deep Underground Science and Engineering Laboratory (DUSEL) in the U.S. The table of contents follows:
1. Overview
2. WIMP Dark Matter: Cosmology, Astrophysics, and Particle Physics
3. Direct Detection of WIMPs
4. Indirect Detection of WIMPs
5. Dark Matter…
▽ More
A study of the current status of WIMP dark matter searches has been made in the context of scientific and technical planning for a Deep Underground Science and Engineering Laboratory (DUSEL) in the U.S. The table of contents follows:
1. Overview
2. WIMP Dark Matter: Cosmology, Astrophysics, and Particle Physics
3. Direct Detection of WIMPs
4. Indirect Detection of WIMPs
5. Dark Matter Candidates and New Physics in the Laboratory
6. Synergies with Other Sub-Fields
7. Direct Detection Experiments: Status and Future Prospects
8. Infrastructure
9. International Context
10. Summary and Outlook
11. Acknowledgments
△ Less
Submitted 23 April, 2007; v1 submitted 30 May, 2006;
originally announced May 2006.
-
Development of Bubble Chambers With Enhanced Stability and Sensitivity to Low-Energy Nuclear Recoils
Authors:
W. J. Bolte,
J. I. Collar,
M. Crisler,
J. Hall,
D. Holmgren,
D. Nakazawa,
B. Odom,
K. O'Sullivan,
R. Plunkett,
E. Ramberg,
A. Raskin,
A. Sonnenschein,
J. D. Vieira
Abstract:
The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent enhanced stability in such a detector are described. Results from prototype trials indicate that sensitivity to low-energy nuclear recoils like those expected…
▽ More
The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent enhanced stability in such a detector are described. Results from prototype trials indicate that sensitivity to low-energy nuclear recoils like those expected from Weakly Interacting Massive Particles can be obtained in conditions of near total insensitivity to minimum ionizing backgrounds. An understanding of the response of superheated heavy refrigerants to these recoils is demonstrated within the context of existing theoretical models. We comment on the prospects for the detection of supersymmetric dark matter particles with a large $CF_{3}I$ chamber.
△ Less
Submitted 17 March, 2005;
originally announced March 2005.
-
Preliminary Limits on the WIMP-Nucleon Cross Section from the Cryogenic Dark Matter Search (CDMS)
Authors:
DS Akerib,
PD Barnes Jr,
DA Bauer,
PL Brink,
B Cabrera,
DO Caldwell,
RM Clarke,
A Da Silva,
AK Davies,
BL Dougherty,
KD Irwin,
RJ Gaitskell,
SR Golwala,
EE Haller,
J Jochum,
WB Knowlton,
V Kuzminov,
SW Nam,
V Novikov,
MJ Penn,
TA Perera,
RR Ross,
B Sadoulet,
RW Schnee,
T Shutt
, et al. (6 additional authors not shown)
Abstract:
We are conducting an experiment to search for WIMPs, or weakly-interacting massive particles, in the galactic halo using terrestrial detectors. This generic class of hypothetical particles, whose properties are similar to those predicted by extensions of the standard model of particle physics, could comprise the cold component of non-baryonic dark matter. We describe our experiment, which is bas…
▽ More
We are conducting an experiment to search for WIMPs, or weakly-interacting massive particles, in the galactic halo using terrestrial detectors. This generic class of hypothetical particles, whose properties are similar to those predicted by extensions of the standard model of particle physics, could comprise the cold component of non-baryonic dark matter. We describe our experiment, which is based on cooled germanium and silicon detectors in a shielded low-background cryostat. The detectors achieve a high degree of background rejection through the simultaneous measurement of the energy in phonons and ionization. Using exposures on the order of one kilogram-day from initial runs of our experiment, we have achieved (preliminary) upper limits on the WIMP-nucleon cross section that are comparable to much longer runs of other experiments.
△ Less
Submitted 30 December, 1997;
originally announced December 1997.