-
MKIDGen3: Energy-Resolving, Single-Photon-Counting MKID Readout on an RFSoC
Authors:
Jennifer Pearl Smith,
John I. Bailey,
III.,
Aled Cuda,
Nicholas Zobrist,
Benjamin A. Mazin
Abstract:
Building large, cryogenic MKID arrays requires processing highly-multiplexed, wideband readout signals in real time; a task that has previously required large, heavy, and power-intensive custom electronics. In this work, we present the third-generation UVOIR MKID readout system (Gen3) which is capable of reading out twice as many detectors with a fifth the weight and power and an order of magnitud…
▽ More
Building large, cryogenic MKID arrays requires processing highly-multiplexed, wideband readout signals in real time; a task that has previously required large, heavy, and power-intensive custom electronics. In this work, we present the third-generation UVOIR MKID readout system (Gen3) which is capable of reading out twice as many detectors with a fifth the weight and power and an order of magnitude less volume and cost-per-pixel as compared to the previous system. Gen3 leverages the Xilinx RFSoC4x2 platform to read out 2048, 1 MHz MKID channels per board. The system takes a modern approach to FPGA design using Vitis High-Level Synthesis (HLS) to specify signal processing blocks in C/C++, Vivado ML Intelligent Design Runs (IDR) to inform implementation stragety and close timing, and Python Productivity for ZYNQ (PYNQ) to simplify interacting with and programming the FPGA using Python. This design suite and tool flow allows general users to contribute to and maintain the design and positions Gen3 to rapidly migrate to future platforms as they become available. In this work, we describe the system requirements, design, and implementation. We also provide performance characterization details and show that the system achieves detector-limited resolving power in the case of few readout tones and minimal degradation with all 2048 tones. Planned upgrades and future work are also discussed. The Gen3 MKID readout system is fully open-source and is expected to facilitate future array scaling to megapixel-sized formats and increase the feasibility of deploying UVOIR MKIDs in space.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
SCExAO and Keck Direct Imaging Discovery of a Low-Mass Companion Around the Accelerating F5 Star HIP 5319
Authors:
Noah Swimmer,
Thayne Currie,
Sarah Steiger,
Gregory Mirek Brandt,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Taylor Tobin,
Tyler D. Groff,
Julien Lozi,
John I. Bailey III,
Alexander B. Walter,
Neelay Fruitwala,
Nicholas Zobrist,
Jennifer Pearl Smith,
Gregoire Coiffard,
Rupert Dodkins,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Nour Skaf,
Vincent Deo,
Nemanja Jovanovic
, et al. (4 additional authors not shown)
Abstract:
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of…
▽ More
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of T=3200 K and surface gravity log($g$)=5.5. Using the relative astrometry for HIP 5319 B from CHARIS and NIRC2 and absolute astrometry for the primary from $Gaia$ and $Hipparcos$ and adopting a log-normal prior assumption for the companion mass, we measure a dynamical mass for HIP 5319 B of $31^{+35}_{-11}M_{\rm J}$, a semimajor axis of $18.6^{+10}_{-4.1}$ au, an inclination of $69.4^{+5.6}_{-15}$ degrees, and an eccentricity of $0.42^{+0.39}_{-0.29}$. However, using an alternate prior for our dynamical model yields a much higher mass of 128$^{+127}_{-88}M_{\rm J}$. Using data taken with the LCOGT NRES instrument we also show that the primary HIP 5319 A is a single star in contrast to previous characterizations of the system as a spectroscopic binary. This work underscores the importance of assumed priors in dynamical models for companions detected with imaging and astrometry and the need to have an updated inventory of system measurements.
△ Less
Submitted 30 July, 2022;
originally announced August 2022.
-
Highly-Multiplexed Superconducting Detector Readout: Approachable High-Speed FPGA Design
Authors:
Jennifer Pearl Smith,
John I. Bailey,
III.,
Benjamin A. Mazin
Abstract:
This work presents the design and preliminary performance of a highly-multiplexed superconducting detector readout. The readout system is implemented on the Xilinx ZCU111 RFSoC Evaluation Board. The current design uses 12% of the DSPs, 60% of the LUTs, 20% of the FFs, and 30% of the BRAM and makes timing at 512 MHz. The system uses two integrated ADCs and DACs running at 4.096 GSPS to read out 2,0…
▽ More
This work presents the design and preliminary performance of a highly-multiplexed superconducting detector readout. The readout system is implemented on the Xilinx ZCU111 RFSoC Evaluation Board. The current design uses 12% of the DSPs, 60% of the LUTs, 20% of the FFs, and 30% of the BRAM and makes timing at 512 MHz. The system uses two integrated ADCs and DACs running at 4.096 GSPS to read out 2,048 superconducting detectors. This work targets a 2x increase in the number of superconducting detectors processed per board with 80% less power than previous readout schemes. The open-source design leverages modern FPGA productivity tools including Vivado High-Level Synthesis to create all custom IP blocks, PYNQ to test and verify individual IP and develop Python drivers, and Vivado ML Intelligent Design Runs to close timing. We emphasize strategies for achieving timing closure without custom HDL which we expect to be useful for superconducting device groups looking to utilize FPGAs in high-performance applications without specialized knowledge in FPGA design.
△ Less
Submitted 30 March, 2022;
originally announced March 2022.
-
SCExAO/MEC and CHARIS Discovery of a Low Mass, 6 AU-Separation Companion to HIP 109427 using Stochastic Speckle Discrimination and High-Contrast Spectroscopy
Authors:
Sarah Steiger,
Thayne Currie,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Tyler D. Groff,
Julien Lozi,
Alexander B. Walter,
Neelay Fruitwala,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Clint Bockstiegel,
Seth R. Meeker,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Ananya Sahoo
, et al. (6 additional authors not shown)
Abstract:
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band a…
▽ More
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up $L_{\rm p}$ photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4-M5.5, 3000-3200 $K$, and $\log_{10}(L/L_{\rm \odot}) = -2.28^{+0.04}_{-0.04}$, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia-Hipparcos absolute astrometry of the primary favor a semimajor axis of $6.55^{+3.0}_{-0.48}$ au, an eccentricity of $0.54^{+0.28}_{-0.15}$, an inclination of $66.7^{+8.5}_{-14}$ degrees, and a dynamical mass of $0.280^{+0.18}_{-0.059}$ $M_{\odot}$. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely-used post-processing methods to directly image faint companions to nearby stars near the telescope diffraction limit.
△ Less
Submitted 12 July, 2021; v1 submitted 11 March, 2021;
originally announced March 2021.
-
The MKID Exoplanet Camera for Subaru SCExAO
Authors:
Alexander B. Walter,
Neelay Fruitwala,
Sarah Steiger,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Seth R. Meeker,
Clint Bockstiegel,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Giulia Collura,
Olivier Guyon,
Julien Lozi,
Sebastien Vievard,
Nemanja Jovanovic,
Frantz Martinache,
Thayne Currie,
Benjamin A. Mazin
Abstract:
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument a…
▽ More
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of $10^{-7}$ at 2$λ/ D$. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MEC's current on-sky performance and end with future upgrades and plans.
△ Less
Submitted 23 October, 2020;
originally announced October 2020.
-
Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave Device Arrays
Authors:
Jennifer Pearl Smith,
Benjamin A. Mazin,
Alex B. Walter,
Miguel Daal,
J. I. Bailey, III,
Clinton Bockstiegel,
Nicholas Zobrist,
Noah Swimmer,
Sarah Steiger,
Neelay Fruitwala
Abstract:
Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA…
▽ More
Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick) soldered to a coplanar wave guide transition board. The 30 cm long cable has 1 dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss is 0.5 dB more than commercially available superconducting coax likely due to impedance mismatches caused by manufacturing imperfections in the cable. The reported cross talk is 30 dB lower than previously developed laminated NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to be 20 nW per trace, approximately half the computed load from the smallest commercially available superconducting coax from CryoCoax
△ Less
Submitted 13 July, 2020;
originally announced July 2020.