-
Ultra stable and very low noise signal source using a cryocooled sapphire oscillator for VLBI
Authors:
Nitin R. Nand,
John G. Hartnett,
Eugene N. Ivanov,
Giorgio Santarelli
Abstract:
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected…
▽ More
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected from the synthesizer seeded with a signal near 11.2 GHz from an ultra-stable cryocooled sapphire oscillator.
The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10 MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130 dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and 100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and sigma_y = 2.2 x 10^-15, at 1 s integration time.
The Allan Deviation of the total fractional frequency noise on the 10 MHz and 100 MHz signals derived from the synthesizer with the cryocooled sapphire oscillator, may be estimated as sigma_y = 5.2 x 10^-15 τ^-1 + 3.6 x 10^-15 τ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 τ^-1/2 + 3 x 10^-16, respectively, for 1 s < τ< 10^4 s.
We also calculate the coherence function, (a figure of merit in VLBI) for observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the cryocooled sapphire oscillator and an hydrogen maser. The results show that the cryocooled sapphire oscillator offers a significant advantage at frequencies above 100 GHz.
△ Less
Submitted 20 April, 2011;
originally announced April 2011.
-
Quantum Physics Exploring Gravity in the Outer Solar System: The Sagas Project
Authors:
P. Wolf,
Ch. J. Bordé,
A. Clairon,
L. Duchayne,
A. Landragin,
P. Lemonde,
G. Santarelli,
W. Ertmer,
E. Rasel,
F. S. Cataliotti,
M. Inguscio,
G. M. Tino,
P. Gill,
H. Klein,
S. Reynaud,
C. Salomon,
E. Peik,
O. Bertolami,
P. Gil,
J. Páramos,
C. Jentsch,
U. Johann,
A. Rathke,
P. Bouyer,
L. Cacciapuoti
, et al. (30 additional authors not shown)
Abstract:
We summarise the scientific and technological aspects of the SAGAS (Search for Anomalous Gravitation using Atomic Sensors) project, submitted to ESA in June 2007 in response to the Cosmic Vision 2015-2025 call for proposals. The proposed mission aims at flying highly sensitive atomic sensors (optical clock, cold atom accelerometer, optical link) on a Solar System escape trajectory in the 2020 to…
▽ More
We summarise the scientific and technological aspects of the SAGAS (Search for Anomalous Gravitation using Atomic Sensors) project, submitted to ESA in June 2007 in response to the Cosmic Vision 2015-2025 call for proposals. The proposed mission aims at flying highly sensitive atomic sensors (optical clock, cold atom accelerometer, optical link) on a Solar System escape trajectory in the 2020 to 2030 time-frame. SAGAS has numerous science objectives in fundamental physics and Solar System science, for example numerous tests of general relativity and the exploration of the Kuiper belt. The combination of highly sensitive atomic sensors and of the laser link well adapted for large distances will allow measurements with unprecedented accuracy and on scales never reached before. We present the proposed mission in some detail, with particular emphasis on the science goals and associated measurements.
△ Less
Submitted 12 August, 2008; v1 submitted 2 November, 2007;
originally announced November 2007.
-
Whispering Gallery Resonators and Tests of Lorentz Invariance
Authors:
Peter Wolf,
Michael E. Tobar,
Sebastien Bize,
Andre Clairon,
Andre N. Luiten,
Giorgio Santarelli
Abstract:
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We give a detailed description of microwave resonators operating in Whispering Gallery modes and then apply it to derive explicit models for Lorentz violating effects in our experiment. Models are calculated in the theoretical framework of Rob…
▽ More
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We give a detailed description of microwave resonators operating in Whispering Gallery modes and then apply it to derive explicit models for Lorentz violating effects in our experiment. Models are calculated in the theoretical framework of Robertson, Mansouri and Sexl and in the standard model extension (SME) of Kostelecky and co-workers. We constrain the parameters of the Mansouri and Sexl test theory to $1/2 - β_{MS} + δ_{MS} = (1.2 \pm 2.2) \times 10^{-9}$ and $β_{MS} - α_{MS} - 1 = (1.6 \pm 3.0) \times 10^{-7}$ which is of the same order as the best results from other experiments for the former and represents a 70 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2.
△ Less
Submitted 10 February, 2004; v1 submitted 6 January, 2004;
originally announced January 2004.
-
Cold Atom Clocks, Precision Oscillators and Fundamental Tests
Authors:
S. Bize,
P. Wolf,
M. Abgrall,
L. Cacciapuoti,
A. Clairon,
J. Gruenert,
Ph. Laurent,
P. Lemonde,
I. Maksimovic,
C. Mandache,
H. Marion,
F. Pereira Dos Santos,
P. Rosenbusch,
G. Santarelli,
Y. Sortais,
C. Vian,
S. Zhang,
C. Salomon,
A. N. Luiten,
M. E. Tobar
Abstract:
We describe two experimental tests of the Equivalence Principle that are based on frequency measurements between precision oscillators and/or highly accurate atomic frequency standards. Based on comparisons between the hyperfine frequencies of 87Rb and 133Cs in atomic fountains, the first experiment constrains the stability of fundamental constants. The second experiment is based on a comparison…
▽ More
We describe two experimental tests of the Equivalence Principle that are based on frequency measurements between precision oscillators and/or highly accurate atomic frequency standards. Based on comparisons between the hyperfine frequencies of 87Rb and 133Cs in atomic fountains, the first experiment constrains the stability of fundamental constants. The second experiment is based on a comparison between a cryogenic sapphire oscillator and a hydrogen maser. It tests Local Lorentz Invariance. In both cases, we report recent results which improve significantly over previous experiments.
△ Less
Submitted 4 October, 2003;
originally announced October 2003.
-
Tests of Lorentz Invariance Using a Microwave Resonator: An Update
Authors:
P. Wolf,
S. Bize,
A. Clairon,
A. N. Luiten,
G. Santarelli,
M. E. Tobar
Abstract:
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters…
▽ More
The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to $δ- β+ 1/2 \leq 3.4 \times 10^{-9}$ and $β- α- 1 \leq 4.1 \times 10^{-7}$ which is of the same order as the best previous result for the former and represents a 50 fold improvement for the latter. These results correspond to an improvement of our previously published limits [Wolf P. et al., Phys. Rev. Lett. {\bf 90}, 6, 060402, (2003)] by about a factor 2. We describe the changes of the experiment, and show the new data that lead to that improvement.
△ Less
Submitted 11 June, 2003;
originally announced June 2003.
-
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Authors:
H. Marion,
F. Pereira Dos Santos,
M. Abgrall,
S. Zhang,
Y. Sortais,
S. Bize,
I. Maksimovic,
D. Calonico,
J. Gruenert,
C. Mandache,
P. Lemonde,
G. Santarelli,
Ph. Laurent,
A. Clairon,
C. Salomon
Abstract:
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma…
▽ More
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.
△ Less
Submitted 31 December, 2002;
originally announced December 2002.