-
Anti-reflection Coated Vacuum Window for the Primordial Inflation Polarization ExploreR (PIPER) balloon-borne instrument
Authors:
Rahul Datta,
David T. Chuss,
Joseph Eimer,
Thomas Essinger-Hileman,
Natalie N. Gandilo,
Kyle Helson,
Alan J. Kogut,
Luke Lowe,
Paul Mirel,
Karwan Rostem,
Marco Sagliocca,
Danielle Sponseller,
Eric R. Switzer,
Peter A. Taraschi,
Edward J. Wollack
Abstract:
Measuring the faint polarization signal of the cosmic microwave background (CMB) not only requires high optical throughput and instrument sensitivity but also control over systematic effects. Polarimetric cameras or receivers used in this setting often employ dielectric vacuum windows, filters, or lenses to appropriately prepare light for detection by cooled sensor arrays. These elements in the op…
▽ More
Measuring the faint polarization signal of the cosmic microwave background (CMB) not only requires high optical throughput and instrument sensitivity but also control over systematic effects. Polarimetric cameras or receivers used in this setting often employ dielectric vacuum windows, filters, or lenses to appropriately prepare light for detection by cooled sensor arrays. These elements in the optical chain are typically designed to minimize reflective losses and hence improve sensitivity while minimizing potential imaging artifacts such as glint and ghosting. The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne instrument designed to measure the polarization of the CMB radiation at the largest angular scales and characterize astrophysical dust foregrounds. PIPER's twin telescopes and detector systems are submerged in an open-aperture liquid helium bucket dewar. A fused-silica window anti-reflection (AR) coated with polytetrafluoroethylene (PTFE) is installed on the vacuum cryostat that houses the cryogenic detector arrays. Light passes from the skyward portions of the telescope to the detector arrays though this window, which utilizes an indium seal to prevent superfluid helium leaks into the vacuum cryostat volume. The AR coating implemented reduces reflections from each interface to <1% compared to ~10% from an uncoated window surface. The AR coating procedure and room temperature optical measurements of the window are presented. The indium vacuum sealing process is also described in detail and test results characterizing its integrity to superfluid helium leaks are provided.
△ Less
Submitted 14 March, 2021;
originally announced March 2021.
-
Fabrication of phononic filter structures for far-IR/sub-mm detector applications
Authors:
Kevin L. Denis,
Karwan Rostem,
Marco A. Sagliocca,
Elissa H. Williams,
Edward J. Wollack
Abstract:
A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19 W/Hz1/2 for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the f…
▽ More
A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19 W/Hz1/2 for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 μm) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one- and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.
△ Less
Submitted 20 December, 2018;
originally announced December 2018.
-
Design and characterization of the Cosmology Large Angular Scale Surveyor (CLASS) 93 GHz focal plane
Authors:
Sumit Dahal,
Aamir Ali,
John W. Appel,
Thomas Essinger-Hileman,
Charles Bennett,
Michael Brewer,
Ricardo Bustos,
Manwei Chan,
David T. Chuss,
Joseph Cleary,
Felipe Colazo,
Jullianna Couto,
Kevin Denis,
Rolando Dünner,
Joseph Eimer,
Trevor Engelhoven,
Pedro Fluxa,
Mark Halpern,
Kathleen Harrington,
Kyle Helson,
Gene Hilton,
Gary Hinshaw,
Johannes Hubmayr,
Jeffrey Iuliano,
Tobias Marriage
, et al. (22 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) aims to detect and characterize the primordial B-mode signal and make a sample-variance-limited measurement of the optical depth to reionization. CLASS is a ground-based, multi-frequency microwave polarimeter that surveys 70% of the microwave sky every day from the Atacama Desert. The focal plane detector arrays of all CLASS telescopes contain smo…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) aims to detect and characterize the primordial B-mode signal and make a sample-variance-limited measurement of the optical depth to reionization. CLASS is a ground-based, multi-frequency microwave polarimeter that surveys 70% of the microwave sky every day from the Atacama Desert. The focal plane detector arrays of all CLASS telescopes contain smooth-walled feedhorns that couple to transition-edge sensor (TES) bolometers through symmetric planar orthomode transducer (OMT) antennas. These low noise polarization-sensitive detector arrays are fabricated on mono-crystalline silicon wafers to maintain TES uniformity and optimize optical efficiency throughout the wafer. In this paper, we discuss the design and characterization of the first CLASS 93 GHz detector array. We measure the dark parameters, bandpass, and noise spectra of the detectors and report that the detectors are photon-noise limited. With current array yield of 82%, we estimate the total array noise-equivalent power (NEP) to be 2.1 aW$\sqrt[]{\mathrm{s}}$.
△ Less
Submitted 10 July, 2018;
originally announced July 2018.
-
A Compact Cryogenic Thermal Source for Detector Array Characterization
Authors:
David T. Chuss,
Karwan Rostem,
Edward J. Wollack,
Leah Berman,
Felipe Colazo,
Martin DeGeorge,
Kyle Helson,
Marco Sagliocca
Abstract:
We describe the design, fabrication, and validation of a cryogenically-compatible quasioptical thermal source designed to be used for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure. The mold is fabricated using a hardened steel template produced via a wire EDM process. The absorptive mixture is bo…
▽ More
We describe the design, fabrication, and validation of a cryogenically-compatible quasioptical thermal source designed to be used for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure. The mold is fabricated using a hardened steel template produced via a wire EDM process. The absorptive mixture is bonded to a copper backplate enabling thermalization of the entire structure. The source reflectance is measured from 30-300 GHz and compared to models.
△ Less
Submitted 18 July, 2017;
originally announced July 2017.
-
The Cosmology Large Angular Scale Surveyor
Authors:
Kathleen Harrington,
Tobias Marriage,
Aamir Ali,
John W. Appel,
Charles L. Bennett,
Fletcher Boone,
Michael Brewer,
Manwei Chan,
David T. Chuss,
Felipe Colazo,
Sumit Dahal,
Kevin Denis,
Rolando Dünner,
Joseph Eimer,
Thomas Essinger-Hileman,
Pedro Fluxa,
Mark Halpern,
Gene Hilton,
Gary F. Hinshaw,
Johannes Hubmayr,
Jeffery Iuliano,
John Karakla,
Jeff McMahon,
Nathan T. Miller,
Samuel H. Moseley
, et al. (11 additional authors not shown)
Abstract:
The Cosmology Large Angular Scale Surveyor (CLASS) is a four telescope array designed to characterize relic primordial gravitational waves from inflation and the optical depth to reionization through a measurement of the polarized cosmic microwave background (CMB) on the largest angular scales. The frequencies of the four CLASS telescopes, one at 38 GHz, two at 93 GHz, and one dichroic system at 1…
▽ More
The Cosmology Large Angular Scale Surveyor (CLASS) is a four telescope array designed to characterize relic primordial gravitational waves from inflation and the optical depth to reionization through a measurement of the polarized cosmic microwave background (CMB) on the largest angular scales. The frequencies of the four CLASS telescopes, one at 38 GHz, two at 93 GHz, and one dichroic system at 145/217 GHz, are chosen to avoid spectral regions of high atmospheric emission and span the minimum of the polarized Galactic foregrounds: synchrotron emission at lower frequencies and dust emission at higher frequencies. Low-noise transition edge sensor detectors and a rapid front-end polarization modulator provide a unique combination of high sensitivity, stability, and control of systematics. The CLASS site, at 5200 m in the Chilean Atacama desert, allows for daily mapping of up to 70\% of the sky and enables the characterization of CMB polarization at the largest angular scales. Using this combination of a broad frequency range, large sky coverage, control over systematics, and high sensitivity, CLASS will observe the reionization and recombination peaks of the CMB E- and B-mode power spectra. CLASS will make a cosmic variance limited measurement of the optical depth to reionization and will measure or place upper limits on the tensor-to-scalar ratio, $r$, down to a level of 0.01 (95\% C.L.).
△ Less
Submitted 29 August, 2016;
originally announced August 2016.