-
High hard X-ray polarization in Cygnus X-1 confined to the intermediate hard state: evidence for a variable jet component
Authors:
Tanmoy Chattopadhyay,
Abhay Kumar,
A. R. Rao,
Yash Bhargava,
Santosh V. Vadawale,
Ajay Ratheesh,
Gulab Dewangan,
Dipankar Bhattacharyay,
Mithun N. P. S.,
Varun Bhalerao
Abstract:
Cygnus X-1, the well-known accreting black hole system, exhibits several observational features hinting at an intricate interplay between the accretion disk, its atmosphere known as the corona and the putative relativistic jet. It has been extensively studied using all available observational methods, including using the newly available technique of sensitive X-ray polarimetry. X-ray polarization…
▽ More
Cygnus X-1, the well-known accreting black hole system, exhibits several observational features hinting at an intricate interplay between the accretion disk, its atmosphere known as the corona and the putative relativistic jet. It has been extensively studied using all available observational methods, including using the newly available technique of sensitive X-ray polarimetry. X-ray polarization characteristics are distinct for coronal and jet emissions. The low X-ray polarization measured below $\sim$100 keV is understood as arising from the corona. In contrast, the high polarization measurements reported above $\sim$400 keV required a separate jet-dominated spectral component, which spectroscopy does not demonstrate conclusively. Here we report precise polarization measurements in the 100-380 keV region made during three different sub-classes of spectral states of the source using the CZTI instrument onboard {\em AstroSat}. A high polarization (23$\pm$4 \%) is found mainly in the Intermediate Hard State of the source, and the energy-resolved measurements smoothly connect the coronal and the jet regimes. When high polarization is observed, the simultaneous spectral data hints at a separate power law component above 100 keV. We examine the possible sources of this energy-dependent high polarization in Cygnus X-1.
△ Less
Submitted 30 November, 2023; v1 submitted 6 June, 2023;
originally announced June 2023.
-
Extending the energy range of AstroSat-CZTI up to 380 keV with Compton Spectroscopy
Authors:
Abhay Kumar,
Tanmoy Chattopadhyay,
Santosh V. Vadawale,
A. R. Rao,
Mithun N. P. S.,
Varun Bhalerao,
Dipankar Bhattacharya
Abstract:
The CZTI (Cadmium Zinc Telluride Imager) onboard AstroSat is a high energy coded mask imager and spectrometer in the energy range of 20 - 100 keV. Above 100 keV, the dominance of Compton scattering cross-section in CZTI results in a significant number of 2-pixel Compton events and these have been successfully utilized for polarization analysis of Crab pulsar and nebula (and transients like Gamma-r…
▽ More
The CZTI (Cadmium Zinc Telluride Imager) onboard AstroSat is a high energy coded mask imager and spectrometer in the energy range of 20 - 100 keV. Above 100 keV, the dominance of Compton scattering cross-section in CZTI results in a significant number of 2-pixel Compton events and these have been successfully utilized for polarization analysis of Crab pulsar and nebula (and transients like Gamma-ray bursts) in 100 - 380 keV. These 2-pixel Compton events can also be used to extend the spectroscopic energy range of CZTI up to 380 keV for bright sources. However, unlike the spectroscopy in primary energy range, where simultaneous background measurement is available from masked pixels, Compton spectroscopy requires blank sky observation for background measurement. Background subtraction, in this case, is non-trivial because of the presence of both short-term and long-term temporal variations in the data, which depend on multiple factors like earth rotation and the effect of South Atlantic Anomaly (SAA) regions etc. We have developed a methodology of background selection and subtraction that takes into account for these effects. Here, we describe these background selection and subtraction techniques and validate them using spectroscopy of Crab in the extended energy range of 30 - 380 keV region, and compare the obtained spectral parameters with the INTEGRAL results. This new capability allows for the extension of the energy range of AstroSat spectroscopy and will also enable the simultaneous spectro-polarimetric study of other bright sources like Cygnus X-1.
△ Less
Submitted 24 August, 2022;
originally announced August 2022.
-
Exploring Sub-MeV Sensitivity of AstroSat-CZTI for ON-axis Bright Sources
Authors:
Abhay Kumar,
Tanmoy Chattopadhyay,
Santosh V Vadawale,
A. R. Rao,
Soumya Gupta,
Mithun N. P. S.,
Varun Bhalerao,
Dipankar Bhattacharya
Abstract:
The Cadmium Zinc Telluride Imager (CZTI) onboard AstroSat is designed for hard X-ray imaging and spectroscopy in the energy range of 20 - 100 keV. The CZT detectors are of 5 mm thickness and hence have good efficiency for Compton interactions beyond 100 keV. The polarisation analysis using CZTI relies on such Compton events and have been verified experimentally. The same Compton events can also be…
▽ More
The Cadmium Zinc Telluride Imager (CZTI) onboard AstroSat is designed for hard X-ray imaging and spectroscopy in the energy range of 20 - 100 keV. The CZT detectors are of 5 mm thickness and hence have good efficiency for Compton interactions beyond 100 keV. The polarisation analysis using CZTI relies on such Compton events and have been verified experimentally. The same Compton events can also be used to extend the spectroscopy up to 380 keV. Further, it has been observed that about 20% pixels of the CZTI detector plane have low gain, and they are excluded from the primary spectroscopy. If these pixels are included, then the spectroscopic capability of CZTI can be extended up to 500 keV and further up to 700 keV with a better gain calibration in the future. Here we explore the possibility of using the Compton events as well as the low gain pixels to extend the spectroscopic energy range of CZTI for ON-axis bright X-ray sources. We demonstrate this technique using Crab observations and explore its sensitivity.
△ Less
Submitted 26 February, 2021;
originally announced February 2021.
-
Design & development of position sensitive detector for hard X-ray using SiPM and new generation scintillators
Authors:
S. K. Goyal,
Amisha P. Naik,
Mithun N. P. S.,
S. V. Vadawale,
Neeraj K. Tiwari,
T. Chattopadhyay,
N. Nagrani,
S. Madhavi,
T. ladiya,
A. R. Patel,
M. Shanmugam,
H. L. Adalja,
V. R. patel,
G. P. Ubale
Abstract:
There is growing interest in high-energy astrophysics community for the development of sensitive instruments in the hard X-ray energy extending to few hundred keV. This requires position sensitive detector modules with high efficiency in the hard X-ray energy range. Here, we present development of a detector module, which consists of 25 mm x 25 mm CeBr3 scintillation detector, read out by a custom…
▽ More
There is growing interest in high-energy astrophysics community for the development of sensitive instruments in the hard X-ray energy extending to few hundred keV. This requires position sensitive detector modules with high efficiency in the hard X-ray energy range. Here, we present development of a detector module, which consists of 25 mm x 25 mm CeBr3 scintillation detector, read out by a custom designed two dimensional array of Silicon Photo-Multipliers (SiPM). Readout of common cathode of SiPMs provides the spectral measurement whereas the readout of individual SiPM anodes provides measurement of interaction position in the crystal. Preliminary results for spectral and position measurements with the detector module are presented here.
△ Less
Submitted 19 October, 2017;
originally announced October 2017.
-
In-orbit performance of AstroSat CZTI
Authors:
Santosh V. Vadawale,
A. R. Rao,
Dipankar Bhattacharya,
Varun B. Bhalerao,
Gulab Chand Dewangan,
Ajay M. Vibute,
Mithun N. P. S.,
Tanmoy Chattopadhyay,
S. Sreekumar
Abstract:
Cadmium-Zinc-Telluride Imager (CZTI) is one of the five payloads on-board recently launched Indian astronomy satellite AstroSat. CZTI is primarily designed for simultaneous hard X-ray imaging and spectroscopy of celestial X-ray sources. It employs the technique of coded mask imaging for measuring spectra in the energy range of 20 - 150 keV. It was the first scientific payload of AstroSat to be swi…
▽ More
Cadmium-Zinc-Telluride Imager (CZTI) is one of the five payloads on-board recently launched Indian astronomy satellite AstroSat. CZTI is primarily designed for simultaneous hard X-ray imaging and spectroscopy of celestial X-ray sources. It employs the technique of coded mask imaging for measuring spectra in the energy range of 20 - 150 keV. It was the first scientific payload of AstroSat to be switched on after one week of the launch and was made operational during the subsequent week. Here we present preliminary results from the performance verification phase observations and discuss the in-orbit performance of CZTI.
△ Less
Submitted 2 September, 2016;
originally announced September 2016.
-
Investigating the connection between Quasi Periodic Oscillations and spectral components with NuSTAR data of GRS 1915+105
Authors:
Anjali Rao Jassal,
Santosh V. Vadawale,
Mithun N. P. S,
Ranjeev Misra
Abstract:
The low frequency quasi periodic oscillations (QPOs) are commonly observed during hard states of black hole binaries. Several studies have established various observational/empirical correlations between spectral parameters and QPO properties, indicating a close link between the two. However, the exact mechanism of generation of QPO is not yet well understood. In this paper, we present our attempt…
▽ More
The low frequency quasi periodic oscillations (QPOs) are commonly observed during hard states of black hole binaries. Several studies have established various observational/empirical correlations between spectral parameters and QPO properties, indicating a close link between the two. However, the exact mechanism of generation of QPO is not yet well understood. In this paper, we present our attempts to comprehend the connection between the spectral components and the low frequency QPO observed in GRS 1915+105 using the data from NuSTAR. Detailed spectral modeling as well as the presence of the low frequency QPO and its energy dependence during this observation have been reported by Miller et al. (2013) and Zhang et al. (2015) respectively. We investigate the compatibility of the spectral model and energy dependence of the QPO by simulating light curves in various energy bands for small variation of the spectral parameters. The basic concept here is to establish connection, if any, between the QPO and the variation of either a spectral component or a specific parameter, which in turn can shed some light on the origin of the QPO. We begin with the best fit spectral model of Miller et al. (2013) and simulate the light curve by varying the spectral parameter at frequencies close to the observed QPO frequency in order to generate the simulated QPO. Further we simulate similar light curves in various energy bands in order to reproduce the observed energy dependence of RMS amplitude of the QPO. We find that the observed trend of increasing RMS amplitude with energy can be reproduced qualitatively if the spectral index is assumed to be varying with the phases of the QPO. Variation of any other spectral parameter does not reproduce the observed energy dependence.
△ Less
Submitted 6 December, 2015;
originally announced December 2015.
-
Development of a Hard X-ray focal plane Compton Polarimeter: A compact polarimetric configuration with Scintillators and Si photomultipliers
Authors:
T. Chattopadhyay,
S. V. Vadawale,
S. K. Goyal,
Mithun N. P. S.,
A. R. Patel,
R. Shukla,
T. Ladiya,
M. Shanmugam,
V. R. Patel,
G. P. Ubale
Abstract:
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of…
▽ More
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm x 5 mm x 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in Chattopadhyay et al. (Exp. Astron. 35, 391-412, 2013; Astrophys. J. Suppl. 212, 12, 2014). In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.
△ Less
Submitted 22 October, 2015;
originally announced October 2015.