Behavioral Characteristics and CO+CO2 Production Rates of Halley-Type Comets Observed by NEOWISE
Authors:
Joshua D. Rosser,
James M. Bauer,
Amy K. Mainzer,
Emily Kramer,
Joseph R. Masiero,
Carrie R. Nugent,
Sarah Sonnett,
Yanga R. Fernandez,
Kinjal Ruecker,
Philip Krings,
Edward L. Wright
Abstract:
From the entire dataset of comets observed by NEOWISE, we have analyzed 11 different Halley-Type Comets (HTCs) for dust production rates, CO+CO2 production rates, and nucleus sizes. Incorporating HTCs from previous studies and multiple comet visits we have a total of 21 stacked visits, 13 of which are active and 8 for which we calculated upper limits of production. We determined the nucleus sizes…
▽ More
From the entire dataset of comets observed by NEOWISE, we have analyzed 11 different Halley-Type Comets (HTCs) for dust production rates, CO+CO2 production rates, and nucleus sizes. Incorporating HTCs from previous studies and multiple comet visits we have a total of 21 stacked visits, 13 of which are active and 8 for which we calculated upper limits of production. We determined the nucleus sizes of 27P, P/2006 HR30, P/2012 NJ, and C/2016 S1. Furthermore, we analyzed the relationships between dust production and heliocentric distance, and gas production and heliocentric distance. We concluded that for this population of HTCs, ranging in heliocentric distance from 1.21 AU to 2.66 AU, there was no significant correlation between dust production and heliocentric distance, nor gas production and heliocentric distance.
△ Less
Submitted 19 February, 2018;
originally announced February 2018.
Proton irradiation results for long-wave HgCdTe infrared detector arrays for NEOCam
Authors:
M. Dorn,
J. L. Pipher,
C. McMurtry,
S. Hartman,
A. Mainzer,
M. McKelvey,
R. McMurray,
D. Chevara,
J. Rosser
Abstract:
HgCdTe detector arrays with a cutoff wavelength of ~10 $μ$m intended for the NEOCam space mission were subjected to proton beam irradiation at the University of California Davis Crocker Nuclear Laboratory. Three arrays were tested - one with 800 $μ$m substrate intact, one with 30 $μ$m substrate, and one completely substrate-removed. The CdZnTe substrate, on which the HgCdTe detector is grown, has…
▽ More
HgCdTe detector arrays with a cutoff wavelength of ~10 $μ$m intended for the NEOCam space mission were subjected to proton beam irradiation at the University of California Davis Crocker Nuclear Laboratory. Three arrays were tested - one with 800 $μ$m substrate intact, one with 30 $μ$m substrate, and one completely substrate-removed. The CdZnTe substrate, on which the HgCdTe detector is grown, has been shown to produce luminescence in shorter wave HgCdTe arrays that causes elevated signal in non-hit pixels when subjected to proton irradiation. This testing was conducted to ascertain whether or not full substrate removal is necessary. At the dark level of the dewar, we detect no luminescence in non-hit pixels during proton testing for both the substrate-removed detector array and the array with 30 $μ$m substrate. The detector array with full 800 $μ$m substrate exhibited substantial photocurrent for a flux of 103 protons/cm$^2$-s at a beam energy of 18.1 MeV (~ 750 e$^-$/s) and 34.4 MeV ($\sim$ 65 e$^-$/s). For the integrated space-like ambient proton flux level measured by the Spitzer Space Telescope, the luminescence would be well below the NEOCam dark current requirement of <200 e$^-$/s, but the pattern of luminescence could be problematic, possibly complicating calibration.
△ Less
Submitted 15 August, 2016;
originally announced August 2016.