-
Concordance: In-flight Calibration of X-ray Telescopes without Absolute References
Authors:
Herman L. Marshall,
Yang Chen,
Jeremy J. Drake,
Matteo Guainazzi,
Vinay L. Kashyap,
Xiao-Li Meng,
Paul P. Plucinsky,
Peter Ratzlaff,
David A. van Dyk,
Xufei Wang
Abstract:
We describe a process for cross-calibrating the effective areas of X-ray telescopes that observe common targets. The targets are not assumed to be "standard candles" in the classic sense, in that we assume that the source fluxes have well-defined, but {\it a priori} unknown values. Using a technique developed by Chen et al. (2019, arXiv:1711.09429) that involves a statistical method called {\em sh…
▽ More
We describe a process for cross-calibrating the effective areas of X-ray telescopes that observe common targets. The targets are not assumed to be "standard candles" in the classic sense, in that we assume that the source fluxes have well-defined, but {\it a priori} unknown values. Using a technique developed by Chen et al. (2019, arXiv:1711.09429) that involves a statistical method called {\em shrinkage estimation}, we determine effective area correction factors for each instrument that brings estimated fluxes into the best agreement, consistent with prior knowledge of their effective areas. We expand the technique to allow unique priors on systematic uncertainties in effective areas for each X-ray astronomy instrument and to allow correlations between effective areas in different energy bands. We demonstrate the method with several data sets from various X-ray telescopes.
△ Less
Submitted 30 August, 2021;
originally announced August 2021.
-
A 33 year constancy of the X-ray coronae of AR Lac and eclipse diagnosis of scale height
Authors:
Jeremy J. Drake,
Peter Ratzlaff,
Vinay Kashyap,
David P. Huenemoerder,
Bradford J. Wargelin,
Deron O. Pease
Abstract:
Extensive X-ray and extreme ultraviolet (EUV) photometric observations of the eclipsing RS CVn system AR Lac were obtained over the years 1997 to 2013 with the Chandra X-ray Observatory Extreme Ultraviolet Explorer. During primary eclipse, HRC count rates decrease by ~40%. A similar minimum is seen during one primary eclipse observed by EUVE but not in others owing to intrinsic source variability.…
▽ More
Extensive X-ray and extreme ultraviolet (EUV) photometric observations of the eclipsing RS CVn system AR Lac were obtained over the years 1997 to 2013 with the Chandra X-ray Observatory Extreme Ultraviolet Explorer. During primary eclipse, HRC count rates decrease by ~40%. A similar minimum is seen during one primary eclipse observed by EUVE but not in others owing to intrinsic source variability. Little evidence for secondary eclipses is present in either the X-ray or EUV data, reminiscent of earlier X-ray and EUV observations. Primary eclipses allow us to estimate the extent of a spherically symmetric corona on the primary G star of about 1.3Rsun, or 0.86Rstar, and indicate the G star is likely brighter than the K component by a factor of 2-5. Brightness changes not attributable to eclipses appear to be dominated by stochastic variability and are generally non-repeating. X-ray and EUV light curves cannot therefore be reliably used to reconstruct the spatial distribution of emission assuming only eclipses and rotational modulation are at work. Moderate flaring is observed, where count rates increase by up to a factor of three above quiescence. Combined with older ASCA, Einstein, EXOSAT, ROSAT and Beppo-SAX observations, the data show that the level of quiescent coronal emission at X-ray wavelengths has remained remarkably constant over 33 years, with no sign of variation due to magnetic cycles. Variations in base level X-ray emission seen by Chandra over 13 years are only ~10%, while variations back to pioneering Einstein observations in 1980 amount to a maximum of 45% and more typically about 15%.
△ Less
Submitted 28 January, 2014;
originally announced January 2014.
-
Accounting for Calibration Uncertainties in X-ray Analysis: Effective Areas in Spectral Fitting
Authors:
Hyunsook Lee,
Vinay L. Kashyap,
David A. van Dyk,
Alanna Connors,
Jeremy J. Drake,
Rima Izem,
Xiao-Li Meng,
Shandong Min,
Taeyoung Park,
Pete Ratzlaff,
Aneta Siemiginowska,
Andreas Zezas
Abstract:
While considerable advance has been made to account for statistical uncertainties in astronomical analyses, systematic instrumental uncertainties have been generally ignored. This can be crucial to a proper interpretation of analysis results because instrumental calibration uncertainty is a form of systematic uncertainty. Ignoring it can underestimate error bars and introduce bias into the fitted…
▽ More
While considerable advance has been made to account for statistical uncertainties in astronomical analyses, systematic instrumental uncertainties have been generally ignored. This can be crucial to a proper interpretation of analysis results because instrumental calibration uncertainty is a form of systematic uncertainty. Ignoring it can underestimate error bars and introduce bias into the fitted values of model parameters. Accounting for such uncertainties currently requires extensive case-specific simulations if using existing analysis packages. Here we present general statistical methods that incorporate calibration uncertainties into spectral analysis of high-energy data. We first present a method based on multiple imputation that can be applied with any fitting method, but is necessarily approximate. We then describe a more exact Bayesian approach that works in conjunction with a Markov chain Monte Carlo based fitting. We explore methods for improving computational efficiency, and in particular detail a method of summarizing calibration uncertainties with a principal component analysis of samples of plausible calibration files. This method is implemented using recently codified Chandra effective area uncertainties for low-resolution spectral analysis and is verified using both simulated and actual Chandra data. Our procedure for incorporating effective area uncertainty is easily generalized to other types of calibration uncertainties.
△ Less
Submitted 22 February, 2011;
originally announced February 2011.
-
X-Ray Flaring on the dMe Star, Ross 154
Authors:
B. J. Wargelin,
V. L. Kashyap,
J. J. Drake,
D. García-Alvarez,
P. W. Ratzlaff
Abstract:
We present results from two Chandra imaging observations of Ross 154, a nearby flaring M dwarf star. During a 61-ks ACIS-S exposure, a very large flare occurred (the equivalent of a solar X3400 event, with L_X = 1.8x10^30 ergs/s) in which the count rate increased by a factor of over 100. The early phase of the flare shows evidence for the Neupert effect, followed by a further rise and then a two…
▽ More
We present results from two Chandra imaging observations of Ross 154, a nearby flaring M dwarf star. During a 61-ks ACIS-S exposure, a very large flare occurred (the equivalent of a solar X3400 event, with L_X = 1.8x10^30 ergs/s) in which the count rate increased by a factor of over 100. The early phase of the flare shows evidence for the Neupert effect, followed by a further rise and then a two-component exponential decay. A large flare was also observed at the end of a later 48-ks HRC-I observation. Emission from the non-flaring phases of both observations was analyzed for evidence of low level flaring. From these temporal studies we find that microflaring probably accounts for most of the `quiescent' emission, and that, unlike for the Sun and the handful of other stars that have been studied, the distribution of flare intensities does not appear to follow a power-law with a single index. Analysis of the ACIS spectra, which was complicated by exclusion of the heavily piled-up source core, suggests that the quiescent Ne/O abundance ratio is enhanced by a factor of ~2.5 compared to the commonly adopted solar abundance ratio, and that the Ne/O ratio and overall coronal metallicity during the flare appear to be enhanced relative to quiescent abundances. Based on the temperatures and emission measures derived from the spectral fits, we estimate the length scales and plasma densities in the flaring volume and also track the evolution of the flare in color-intensity space. Lastly, we searched for a stellar-wind charge-exchange X-ray halo around the star but without success; because of the relationship between mass-loss rate and the halo surface brightness, not even an upper limit on the stellar mass-loss rate can be determined.
△ Less
Submitted 17 December, 2007;
originally announced December 2007.
-
Doppler Shifts and Broadening and the Structure of the X-ray Emission from Algol
Authors:
Sun Mi Chung,
Jeremy J. Drake,
Vinay L. Kashyap,
Li Wei Lin,
Peter W. Ratzlaff
Abstract:
In a study of Chandra High Energy Transmission Grating spectra of Algol, we clearly detect Doppler shifts caused by the orbital motion of Algol B. These data provide the first definitive proof that the X-ray emission of Algol is dominated by the secondary, in concordance with expectations that Algol A (B8) is X-ray dark. The measured Doppler shifts are slightly smaller than expected, implying an…
▽ More
In a study of Chandra High Energy Transmission Grating spectra of Algol, we clearly detect Doppler shifts caused by the orbital motion of Algol B. These data provide the first definitive proof that the X-ray emission of Algol is dominated by the secondary, in concordance with expectations that Algol A (B8) is X-ray dark. The measured Doppler shifts are slightly smaller than expected, implying an effective orbital radius of about 10 Rsolar, instead of 11.5 Rsolar for the Algol B center of mass. This could be caused by a small contribution of X-ray flux from Algol A (10-15%), possibly through accretion. The more likely explanation is an asymmetric corona biased toward the system center of mass by the tidal distortion of the surface of Algol B. Analysis of the strongest lines indicates excess line broadening of ~150 km/s above that expected from thermal motion and surface rotation. Possible explanations include turbulence, flows or explosive events, or rotational broadening from a radially extended corona. We favor the latter scenario and infer that a significant component of the corona at temperatures <10^7 K has a scale height of order the stellar radius. This is supported by the shape of the X-ray lightcurve and the shallow dip at secondary eclipse. We also examine the O VII intercombination and forbidden lines in a Low Energy Transmission Grating Spectrograph observation and find no change in their relative line fluxes as the system goes from quadrature to primary eclipse. Since these lines are strongly affected by UV irradiation from Algol A, this supports the conjecture that the corona of Algol B at temperatures of several million K must be significantly extended and/or located toward the poles to avoid being shadowed from Algol A during primary eclipse.
△ Less
Submitted 27 January, 2004;
originally announced January 2004.
-
Chandra Multi-wavelength Project (ChaMP). II. First Results of X-ray Source Properties
Authors:
D. -W. Kim,
B. J. Wilkes,
P. J. Green,
R. A. Cameron,
J. J. Drake,
N. R. Evans,
P. Freeman,
T. J. Gaetz,
H. Ghosh,
F. R. Harnden, Jr.,
M. Karovska,
V. Kashyap,
P. W. Maksym,
P. W. Ratzlaff,
E. M. Schlegel,
J. D. Silverman,
H. D. Tananbaum,
A. A. Vikhlinin
Abstract:
We present the first results of ChaMP X-ray source properties obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. Utilizing only near on-axis, bright X-ray sources (to avoid problems caused by incompleteness and the Eddington bias), we derive the Log(N…
▽ More
We present the first results of ChaMP X-ray source properties obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. Utilizing only near on-axis, bright X-ray sources (to avoid problems caused by incompleteness and the Eddington bias), we derive the Log(N)-Log(S) relation in soft (0.5-2 keV) and hard (2-8 keV) energy bands. The ChaMP data are consistent with previous results of ROSAT, ASCA and Chandra deep surveys. In particular, our data nicely fill in the flux gap in the hard band between the Chandra Deep Field data and the previous ASCA data. We check whether there is any systematic difference in the source density between cluster and non-cluster fields and also search for field-to-field variations, both of which have been previously reported. We found no significant field-to-field cosmic variation in either test within the statistics (~1 sigma) across the flux levels included in our sample. In the X-ray color-color plot, most sources fall in the location characterized by photon index = 1.5-2 and NH = a few x 10^20 cm^2, suggesting that they are typical broad-line AGNs. There also exist a considerable number of sources with peculiar X-ray colors (e.g., highly absorbed, very hard, very soft). We confirm a trend that on average the X-ray color hardens as the count rate decreases. Since the hardening is confined to the softest energy band (0.3-0.9 keV), we conclude it is most likely due to absorption. We cross-correlate the X-ray sources with other catalogs and describe their properties in terms of optical color, X-ray-to-optical luminosity ratio and X-ray colors.
△ Less
Submitted 27 August, 2003;
originally announced August 2003.
-
Chandra Multi-wavelength Project (ChaMP). I. First X-ray Source Catalog
Authors:
D. -W. Kim,
R. A. Cameron,
J. J. Drake,
N. R. Evans,
P. Freeman,
T. J. Gaetz,
H. Ghosh,
P. J. Green,
F. R. Harnden, Jr.,
M. Karovska,
V. Kashyap,
P. W. Maksym,
P. W. Ratzlaff,
E. M. Schlegel,
J. D. Silverman,
H. D. Tananbaum,
A. A. Vikhlinin,
B. J. Wilkes,
J. P. Grimes
Abstract:
The Chandra Multi-wavelength Project (ChaMP) is a wide-area (~14 deg^2) survey of serendipitous Chandra X-ray sources, aiming to establish fair statistical samples covering a wide range of characteristics (such as absorbed AGNs, high z clusters of galaxies) at flux levels (fX ~ 10^-15 - 10^-14 erg sec-1 cm-2) intermediate between the Chandra Deep surveys and previous missions. We present the fir…
▽ More
The Chandra Multi-wavelength Project (ChaMP) is a wide-area (~14 deg^2) survey of serendipitous Chandra X-ray sources, aiming to establish fair statistical samples covering a wide range of characteristics (such as absorbed AGNs, high z clusters of galaxies) at flux levels (fX ~ 10^-15 - 10^-14 erg sec-1 cm-2) intermediate between the Chandra Deep surveys and previous missions. We present the first ChaMP catalog, which consists of 991 near on-axis, bright X-ray sources obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. To assess source reliability and positional uncertainty, we perform a series of simulations and also use Chandra data to complement the simulation study. The false source detection rate is found to be as good as or better than expected for a given limiting threshold. On the other hand, the chance of missing a real source is rather complex, depending on the source counts, off-axis distance (or PSF), and background rate. The positional error (95% confidence level) is usually < 1" for a bright source, regardless of its off-axis distance while it can be as large as 4" for a weak source (~20 counts) at a large off-axis distance (Doff-axis > 8'). We have also developed new methods to find spatially extended or temporary variable sources and those sources are listed in the catalog.
△ Less
Submitted 27 August, 2003;
originally announced August 2003.
-
First Light Measurements of Capella with the Low Energy Transmission Grating Spectrometer aboard the Chandra X-ray Observatory
Authors:
A. C. Brinkman,
C. J. T. Gunsing,
J. S. Kaastra,
R. L. J. van der Meer,
R. Mewe,
F. Paerels,
A. J. J. Raassen,
J. J. van Rooijen,
H. Bräuninger,
W. Burkert,
V. Burwitz,
G. Hartner,
P. Predehl,
J. -U. Ness,
J. H. M. M. Schmitt,
J. J. Drake,
O. Johnson,
M. Juda,
V. Kashyap,
S. S. Murray,
D. Pease,
P. Ratzlaff,
B. J. Wargelin
Abstract:
We present the first X-ray spectrum obtained by the Low Energy Transmission Grating Spectrometer (LETGS) aboard the Chandra X-ray Observatory. The spectrum is of Capella and covers a wavelength range of 5-175 A (2.5-0.07 keV). The measured wavelength resolution, which is in good agreement with ground calibration, is $Δλ\simeq$ 0.06 A (FWHM). Although in-flight calibration of the LETGS is in prog…
▽ More
We present the first X-ray spectrum obtained by the Low Energy Transmission Grating Spectrometer (LETGS) aboard the Chandra X-ray Observatory. The spectrum is of Capella and covers a wavelength range of 5-175 A (2.5-0.07 keV). The measured wavelength resolution, which is in good agreement with ground calibration, is $Δλ\simeq$ 0.06 A (FWHM). Although in-flight calibration of the LETGS is in progress, the high spectral resolution and unique wavelength coverage of the LETGS are well demonstrated by the results from Capella, a coronal source rich in spectral emission lines. While the primary purpose of this letter is to demonstrate the spectroscopic potential of the LETGS, we also briefly present some preliminary astrophysical results. We discuss plasma parameters derived from line ratios in narrow spectral bands, such as the electron density diagnostics of the He-like triplets of carbon, nitrogen, and oxygen, as well as resonance scattering of the strong Fe XVII line at 15.014 A.
△ Less
Submitted 4 January, 2000;
originally announced January 2000.