-
Results from the CsI Calorimeter onboard the 2023 ComPair Balloon Flight
Authors:
Daniel Shy,
Richard S. Woolf,
Clio Sleator,
Bernard Phlips,
J. Eric Grove,
Eric A. Wulf,
Mary Johnson-Rambert,
Mitch Davis,
Emily Kong,
Thomas Caligiure,
A. Wilder Crosier,
Aleksey Bolotnikov,
Nicholas Cannady,
Gabriella A. Carini,
Regina Caputo,
Jack Fried,
Priyarshini Ghosh,
Sean Griffin,
Elizabeth Hays,
Sven Herrmann,
Carolyn Kierans,
Nicholas Kirschner,
Iker Liceaga-Indart,
Zachary Metzler,
Julie McEnery
, et al. (11 additional authors not shown)
Abstract:
The ComPair gamma-ray telescope is a technology demonstrator for a future gamma-ray telescope called the All-sky Medium Energy Gamma-ray Observatory (AMEGO). The instrument is composed of four subsystems, a double-sided silicon strip detector, a virtual Frisch grid CdZnTe calorimeter, a CsI:Tl based calorimeter, and an anti-coincidence detector (ACD). The CsI calorimeter's goal is to measure the p…
▽ More
The ComPair gamma-ray telescope is a technology demonstrator for a future gamma-ray telescope called the All-sky Medium Energy Gamma-ray Observatory (AMEGO). The instrument is composed of four subsystems, a double-sided silicon strip detector, a virtual Frisch grid CdZnTe calorimeter, a CsI:Tl based calorimeter, and an anti-coincidence detector (ACD). The CsI calorimeter's goal is to measure the position and energy deposited from high-energy events. To demonstrate the technological readiness, the calorimeter has flown onboard a NASA scientific balloon as part of the GRAPE-ComPair mission and accumulated around 3 hours of float time at an altitude of 40 km. During the flight, the CsI calorimeter observed background radiation, Regener-Pfotzer Maximum, and several gamma-ray activation lines originating from aluminum.
△ Less
Submitted 29 May, 2024; v1 submitted 10 May, 2024;
originally announced May 2024.
-
Exploring Large-Volume GAGG Scintillators for use in MeV Gamma-Ray Astrophysics
Authors:
Daniel Shy,
Richard Woolf,
Bernard Phlips,
Mary Johnson-Rambert,
Emily Kong
Abstract:
Gamma-ray astrophysics in the MeV band is an exciting field in astronomy due to its potential for multi-messenger astrophysics. It has, however, remained under-explored when compared to other wavelengths. One reason for this observational gap is the difficulties with measuring these high-energy photons and the requirement of large amounts of detection material. In this work, we investigate the usa…
▽ More
Gamma-ray astrophysics in the MeV band is an exciting field in astronomy due to its potential for multi-messenger astrophysics. It has, however, remained under-explored when compared to other wavelengths. One reason for this observational gap is the difficulties with measuring these high-energy photons and the requirement of large amounts of detection material. In this work, we investigate the usage of large-volume GAGG scintillators for use as a calorimeter in future MeV telescopes. We developed a $5\times5$ array calorimeter utilizing $1\times1\times6 \ \mathrm{cm}^3$ GAGG crystals with C-series SiPM readout. The calorimeter was tested at the High Intensity Gamma-ray Facility (HIGS) with monoenergetic beams ranging from $2-25 \ \mathrm{MeV}$. Finally, we also investigated larger $1\times1\times8 \ \mathrm{cm}^3$ crystals and characterized their response across their depth when their surface treatment is either polished or frosted.
△ Less
Submitted 24 May, 2024; v1 submitted 10 May, 2024;
originally announced May 2024.
-
The Compton-Pair telescope: A prototype for a next-generation MeV $γ$-ray observatory
Authors:
Janeth Valverde,
Nicholas Kirschner,
Zachary Metzler,
Lucas D. Smith,
Nicholas Cannady,
Regina Caputo,
Carolyn Kierans,
Iker Liceaga-Indart,
Alexander Moiseev,
Lucas Parker,
Makoto Sasaki,
Adam Schoenwald,
Daniel Shy,
Sambid Wasti,
Richard Woolf,
Aleksey Bolotnikov,
Gabriella Carini,
A. W. Crosier,
T. Caligure,
Alfred Dellapenna Jr,
Jack Fried,
P. Ghosh,
Sean Griffin,
J. Eric Grove,
Elizabeth Hays
, et al. (9 additional authors not shown)
Abstract:
The Compton Pair (ComPair) telescope is a prototype that aims to develop the necessary technologies for future medium energy gamma-ray missions and to design, build, and test the prototype in a gamma-ray beam and balloon flight. The ComPair team has built an instrument that consists of 4 detector subsystems: a double-sided silicon strip detector Tracker, a novel high-resolution virtual Frisch-grid…
▽ More
The Compton Pair (ComPair) telescope is a prototype that aims to develop the necessary technologies for future medium energy gamma-ray missions and to design, build, and test the prototype in a gamma-ray beam and balloon flight. The ComPair team has built an instrument that consists of 4 detector subsystems: a double-sided silicon strip detector Tracker, a novel high-resolution virtual Frisch-grid cadmium zinc telluride Calorimeter, and a high-energy hodoscopic cesium iodide Calorimeter, all of which are surrounded by a plastic scintillator anti-coincidence detector. These subsystems together detect and characterize photons via Compton scattering and pair production, enable a veto of cosmic rays, and are a proof-of-concept for a space telescope with the same architecture. A future medium-energy gamma-ray mission enabled through ComPair will address many questions posed in the Astro2020 Decadal survey in both the New Messengers and New Physics and the Cosmic Ecosystems themes. In this contribution, we will give an overview of the ComPair project and steps forward to the balloon flight.
△ Less
Submitted 26 August, 2023; v1 submitted 23 August, 2023;
originally announced August 2023.
-
Radiation Damage of $2 \times 2 \times 1 \ \mathrm{cm}^3$ Pixelated CdZnTe Due to High-Energy Protons
Authors:
Daniel Shy,
David Goodman,
Ryan Parsons,
Michael Streicher,
Willy Kaye,
Lee Mitchell,
Zhong He,
Bernard Phlips
Abstract:
Pixelated CdZnTe detectors are a promising imaging-spectrometer for gamma-ray astrophysics due to their combination of relatively high energy resolution with room temperature operation negating the need for cryogenic cooling. This reduces the size, weight, and power requirements for telescope-based radiation detectors. Nevertheless, operating CdZnTe in orbit will expose it to the harsh radiation e…
▽ More
Pixelated CdZnTe detectors are a promising imaging-spectrometer for gamma-ray astrophysics due to their combination of relatively high energy resolution with room temperature operation negating the need for cryogenic cooling. This reduces the size, weight, and power requirements for telescope-based radiation detectors. Nevertheless, operating CdZnTe in orbit will expose it to the harsh radiation environment of space. This work, therefore, studies the effects of $61 \ \mathrm{MeV}$ protons on $2 \times 2 \times 1 \ \mathrm{cm}^3$ pixelated CdZnTe and quantifies proton-induced radiation damage of fluences up to $2.6 \times 10^8 \ \mathrm{p/cm^2}$. In addition, we studied the effects of irradiation on two separate instruments: one was biased and operational during irradiation while the other remained unbiased. Following final irradiation, the $662 \ \mathrm{keV}$ centroid and nominal $1\%$ resolution of the detectors were degraded to $642.7 \ \mathrm{keV}, 4.9 \% \ ( \mathrm{FWHM})$ and $653.8 \ \mathrm{keV}, 1.75 \% \ (\mathrm{FWHM})$ for the biased and unbiased systems respectively. We therefore observe a possible bias dependency on proton-induced radiation damage in CdZnTe. This work also reports on the resulting activation and recovery of the instrument following room temperature and $60^{\circ}\mathrm{C}$ annealing.
△ Less
Submitted 5 August, 2023;
originally announced August 2023.
-
Development of Dual-Gain SiPM Boards for Extending the Energy Dynamic Range
Authors:
Daniel Shy,
Richard S. Woolf,
Eric A. Wulf,
Clio C. Sleator,
Mary Johnson-Rambert,
W. Neil Johnson,
J. Eric Grove,
Bernard F. Phlips
Abstract:
Astronomical observations with gamma rays in the range of several hundred keV to hundreds of MeV currently represent the least explored energy range. To address this so-called MeV gap, we designed and built a prototype CsI:Tl calorimeter instrument using a commercial off-the-shelf (COTS) SiPMs and front-ends which may serve as a subsystem for a larger gamma-ray mission concept. During development,…
▽ More
Astronomical observations with gamma rays in the range of several hundred keV to hundreds of MeV currently represent the least explored energy range. To address this so-called MeV gap, we designed and built a prototype CsI:Tl calorimeter instrument using a commercial off-the-shelf (COTS) SiPMs and front-ends which may serve as a subsystem for a larger gamma-ray mission concept. During development, we observed significant non-linearity in the energy response. Additionally, using the COTS readout, the calorimeter could not cover the four orders of magnitude in energy range required for the telescope. We, therefore, developed dual-gain silicon photomultiplier (SiPM) boards that make use of two SiPM species that are read out separately to increase the dynamic energy range of the readout. In this work, we investigate the SiPM's response with regards to active area ($3\times3 \ \mathrm{mm}^2$ and $1 \times 1 \ \mathrm{mm}^2$) and various microcell sizes ($10$, $20$, and $35 \ μ\mathrm{m}$). We read out $3\times3\times6 \ \mathrm{cm}^3$ CsI:Tl chunks using dual-gain SiPMs that utilize $35 \ μ\mathrm{m}$ microcells for both SiPM species and demonstrate the concept when tested with high-energy gamma-ray and proton beams. We also studied the response of $17 \times 17 \times 100 \ \mathrm{mm}^3$ CsI bars to high-energy protons. With the COTS readout, we demonstrate a sensitivity to $60 \ \mathrm{MeV}$ protons with the two SiPM species overlapping at a range of around $2.5-30 \ \mathrm{MeV}$. This development aims to demonstrate the concept for future scintillator-based high-energy calorimeters with applications in gamma-ray astrophysics.
△ Less
Submitted 31 August, 2023; v1 submitted 20 July, 2023;
originally announced July 2023.
-
Development of a CsI Calorimeter for the Compton-Pair (ComPair) Balloon-Borne Gamma-Ray Telescope
Authors:
Daniel Shy,
Richard S. Woolf,
Clio C. Sleator,
Eric A. Wulf,
Mary Johnson-Rambert,
Emily Kong,
J. Mitch Davis,
Thomas J. Caligiure,
J. Eric Grove,
Bernard F. Phlips
Abstract:
There is a growing interest in astrophysics to fill in the observational gamma-ray MeV gap. We, therefore, developed a CsI:Tl calorimeter prototype as a subsystem to a balloon-based Compton and Pair-production telescope known as ComPair. ComPair is a technology demonstrator for a gamma-ray telescope in the MeV range that is comprised of 4 subsystems: the double-sided silicon detector, virtual Fris…
▽ More
There is a growing interest in astrophysics to fill in the observational gamma-ray MeV gap. We, therefore, developed a CsI:Tl calorimeter prototype as a subsystem to a balloon-based Compton and Pair-production telescope known as ComPair. ComPair is a technology demonstrator for a gamma-ray telescope in the MeV range that is comprised of 4 subsystems: the double-sided silicon detector, virtual Frisch grid CdZnTe, CsI calorimeter, and a plastic-based anti-coincidence detector. The prototype CsI calorimeter is composed of thirty CsI logs, each with a geometry of $1.67 \times 1.67 \times 10 \ \mathrm{cm^3}$. The logs are arranged in a hodoscopic fashion with 6 in a row that alternate directions in each layer. Each log has a resolution of around $8 \%$ full-width-at-half-maximum (FWHM) at $662 \ \mathrm{keV}$ with a dynamic energy range of around $250\ \mathrm{keV}-30 \ \mathrm{MeV}$. A $2\times2$ array of SensL J-series SiPMs read out each end of the log to estimate the depth of interaction and energy deposition with signals read out with an IDEAS ROSSPAD. We also utilize an Arduino to synchronize with the other ComPair subsystems that comprise the full telescope. This work presents the development and performance of the calorimeter, its testing in thermal and vacuum conditions, and results from irradiation by $2-25 \ \mathrm{MeV}$ monoenergetic gamma-ray beams. The CsI calorimeter will fly onboard ComPair as a balloon experiment in the summer of 2023.
△ Less
Submitted 31 August, 2023; v1 submitted 20 July, 2023;
originally announced July 2023.
-
Development of the ComPair gamma-ray telescope prototype
Authors:
Daniel Shy,
Carolyn Kierans,
Nicolas Cannady,
Regina Caputo,
Sean Griffin,
J. Eric Grove,
Elizabeth Hays,
Emily Kong,
Nicholas Kirschner,
Iker Liceaga-Indart,
Julie McEnery,
John Mitchell,
A. A. Moiseev,
Lucas Parker,
Jeremy S. Perkins,
Bernard Phlips,
Makoto Sasaki,
Adam J. Schoenwald,
Clio Sleator,
Jacob Smith,
Lucas D. Smith,
Sambid Wasti,
Richard Woolf,
Eric Wulf,
Anna Zajczyk
Abstract:
There is a growing interest in the science uniquely enabled by observations in the MeV range, particularly in light of multi-messenger astrophysics. The Compton Pair (ComPair) telescope, a prototype of the AMEGO Probe-class concept, consists of four subsystems that together detect and characterize gamma rays in the MeV regime. A double-sided strip silicon Tracker gives a precise measure of the fir…
▽ More
There is a growing interest in the science uniquely enabled by observations in the MeV range, particularly in light of multi-messenger astrophysics. The Compton Pair (ComPair) telescope, a prototype of the AMEGO Probe-class concept, consists of four subsystems that together detect and characterize gamma rays in the MeV regime. A double-sided strip silicon Tracker gives a precise measure of the first Compton scatter interaction and tracks pair-conversion products. A novel cadmium zinc telluride (CZT) detector with excellent position and energy resolution beneath the Tracker detects the Compton-scattered photons. A thick cesium iodide (CsI) calorimeter contains the high-energy Compton and pair events. The instrument is surrounded by a plastic anti-coincidence (ACD) detector to veto the cosmic-ray background. In this work, we will give an overview of the science motivation and a description of the prototype development and performance.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
The All-sky Medium Energy Gamma-ray Observatory eXplorer (AMEGO-X) Mission Concept
Authors:
Regina Caputo,
Marco Ajello,
Carolyn Kierans,
Jeremy Perkins,
Judith Racusin,
Luca Baldini,
Matthew Barring,
Elisabetta Bissaldi,
Eric Burns,
Nicolas Cannady,
Eric Charles,
Rui Curado da Silva,
Ke Fang,
Henrike Fleischhack,
Chris Fryer,
Yasushi Fukazawa,
J. Eric Grove,
Dieter Hartmann,
Eric Howell,
Manoj Jadhav,
Christopher Karwin,
Daniel Kocevski,
Naoko Kurahashi,
Luca Latronico,
Tiffany Lewis
, et al. (30 additional authors not shown)
Abstract:
The All-sky Medium Energy Gamma-ray Observatory eXplorer (AMEGO-X) is designed to identify and characterize gamma rays from extreme explosions and accelerators. The main science themes include: supermassive black holes and their connections to neutrinos and cosmic rays; binary neutron star mergers and the relativistic jets they produce; cosmic ray particle acceleration sources including Galactic s…
▽ More
The All-sky Medium Energy Gamma-ray Observatory eXplorer (AMEGO-X) is designed to identify and characterize gamma rays from extreme explosions and accelerators. The main science themes include: supermassive black holes and their connections to neutrinos and cosmic rays; binary neutron star mergers and the relativistic jets they produce; cosmic ray particle acceleration sources including Galactic supernovae; and continuous monitoring of other astrophysical events and sources over the full sky in this important energy range. AMEGO-X will probe the medium energy gamma-ray band using a single instrument with sensitivity up to an order of magnitude greater than previous telescopes in the energy range 100 keV to 1 GeV that can be only realized in space. During its three-year baseline mission, AMEGO-X will observe nearly the entire sky every two orbits, building up a sensitive all-sky map of gamma-ray sources and emission. AMEGO-X was submitted in the recent 2021 NASA MIDEX Announcement of Opportunity.
△ Less
Submitted 4 November, 2022; v1 submitted 9 August, 2022;
originally announced August 2022.
-
The Compton Spectrometer and Imager Project for MeV Astronomy
Authors:
John A. Tomsick,
Steven E. Boggs,
Andreas Zoglauer,
Eric Wulf,
Lee Mitchell,
Bernard Phlips,
Clio Sleator,
Terri Brandt,
Albert Shih,
Jarred Roberts,
Pierre Jean,
Peter von Ballmoos,
Juan Martinez Oliveros,
Alan Smale,
Carolyn Kierans,
Dieter Hartmann,
Mark Leising,
Marco Ajello,
Eric Burns,
Chris Fryer,
Pascal Saint-Hilaire,
Julien Malzac,
Fabrizio Tavecchio,
Valentina Fioretti,
Andrea Bulgarelli
, et al. (11 additional authors not shown)
Abstract:
The Compton Spectrometer and Imager (COSI) is a 0.2-5 MeV Compton telescope capable of imaging, spectroscopy, and polarimetry of astrophysical sources. Such capabilities are made possible by COSI's germanium cross-strip detectors, which provide high efficiency, high resolution spectroscopy and precise 3D positioning of photon interactions. Science goals for COSI include studies of 0.511 MeV emissi…
▽ More
The Compton Spectrometer and Imager (COSI) is a 0.2-5 MeV Compton telescope capable of imaging, spectroscopy, and polarimetry of astrophysical sources. Such capabilities are made possible by COSI's germanium cross-strip detectors, which provide high efficiency, high resolution spectroscopy and precise 3D positioning of photon interactions. Science goals for COSI include studies of 0.511 MeV emission from antimatter annihilation in the Galaxy, mapping radioactive elements from nucleosynthesis, determining emission mechanisms and source geometries with polarization, and detecting and localizing multimessenger sources. The instantaneous field of view (FOV) for the germanium detectors is >25% of the sky, and they are surrounded on the sides and bottom by active shields, providing background rejection as well as allowing for detection of gamma-ray bursts or other gamma-ray flares over >50% of the sky. We have completed a Phase A concept study to consider COSI as a Small Explorer (SMEX) satellite mission, and here we discuss the advances COSI-SMEX provides for astrophysics in the MeV bandpass.
△ Less
Submitted 21 September, 2021;
originally announced September 2021.
-
Glowbug, a Low-Cost, High-Sensitivity Gamma-Ray Burst Telescope
Authors:
J. E. Grove,
C. C. Cheung,
M. Kerr,
L. J. Mitchell,
B. F. Phlips,
R. S. Woolf,
E. A. Wulf,
M. S. Briggs,
C. A. Wilson-Hodge,
D. Kocevski,
J. Perkins
Abstract:
We describe Glowbug, a gamma-ray telescope for bursts and other transients in the 30 keV to 2 MeV band. It was recently selected for funding by the NASA Astrophysics Research and Analysis program, with an expected launch in the early 2020s. Similar in concept to the Fermi Gamma Burst Monitor (GBM) and with similar sensitivity, Glowbug will join and enhance future networks of burst telescopes to in…
▽ More
We describe Glowbug, a gamma-ray telescope for bursts and other transients in the 30 keV to 2 MeV band. It was recently selected for funding by the NASA Astrophysics Research and Analysis program, with an expected launch in the early 2020s. Similar in concept to the Fermi Gamma Burst Monitor (GBM) and with similar sensitivity, Glowbug will join and enhance future networks of burst telescopes to increase sky coverage to short Gamma-Ray Bursts (SGRBs) from binary neutron star (BNS) mergers, including possible SGRBs from NS-black hole mergers. With the recent discovery of the SGRB coincident with the gravitational wave transient GW170817, we know such events occur with reasonable frequency. Expanded sky coverage in gamma rays is essential, as more detections of gravitational waves are expected with the improved sensitivity of the upgraded ground-based interferometers in the coming years.
△ Less
Submitted 24 September, 2020;
originally announced September 2020.
-
Radiation damage assessment of SensL SiPMs
Authors:
Lee J. Mitchell,
Bernard Phlips,
W. Neil Johnson,
Mary Johnson-Rambert,
Anika N. Kansky,
Richard Woolf
Abstract:
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have shown to be susceptible to radiation damage. SensL SiPMs with different cell sizes were irradiated with 64 MeV protons and 8 MeV electrons. In general, results s…
▽ More
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have shown to be susceptible to radiation damage. SensL SiPMs with different cell sizes were irradiated with 64 MeV protons and 8 MeV electrons. In general, results show larger cell sizes are more susceptible to radiation damage with the largest 50 um SiPMs showing the greatest increase in current as a function of dose. Current increases were observed for doses as low at ~2 rad(Si) for protons and ~20 rad(Si) for electrons. The U.S. Naval Research Laboratory's (NRL) Strontium Iodide Radiation Instrument (SIRI-1) experienced a 528 uA increase in the bias current of the on-board 2x2 SensL J-series 60035 SiPM over its one-year mission in sun-synchronous orbit. The work here focuses on the increase in bulk current observed with increasing radiation damage and was performed to better quantify this effect as a function of dose for future mission. These include the future NRL mission SIRI-2, the follow on to SIRI-1, Glowbug and the GAGG Radiation Instrument (GARI).
△ Less
Submitted 17 March, 2020;
originally announced March 2020.
-
The Compton Spectrometer and Imager
Authors:
John A. Tomsick,
Andreas Zoglauer,
Clio Sleator,
Hadar Lazar,
Jacqueline Beechert,
Steven Boggs,
Jarred Roberts,
Thomas Siegert,
Alex Lowell,
Eric Wulf,
Eric Grove,
Bernard Phlips,
Terri Brandt,
Alan Smale,
Carolyn Kierans,
Eric Burns,
Dieter Hartmann,
Mark Leising,
Marco Ajello,
Chris Fryer,
Mark Amman,
Hsiang-Kuang Chang,
Pierre Jean,
Peter von Ballmoos
Abstract:
In this Astro2020 APC White Paper, we describe a Small Explorer (SMEX) mission concept called the Compton Spectrometer and Imager. COSI is a Compton telescope that covers the bandpass often referred to as the "MeV Gap" because it is the least explored region of the whole electromagnetic spectrum. COSI provides a significant improvement in sensitivity along with high-resolution spectroscopy, enabli…
▽ More
In this Astro2020 APC White Paper, we describe a Small Explorer (SMEX) mission concept called the Compton Spectrometer and Imager. COSI is a Compton telescope that covers the bandpass often referred to as the "MeV Gap" because it is the least explored region of the whole electromagnetic spectrum. COSI provides a significant improvement in sensitivity along with high-resolution spectroscopy, enabling studies of 511 keV electron-positron annihilation emission and measurements of several radioactive elements that trace the Galactic history of supernovae. COSI also measures polarization of gamma-ray bursts (GRBs), accreting black holes, and pulsars as well as detecting and localizing multimessenger sources. In the following, we describe the COSI science, the instrument, and its capabilities. We highlight many Astro2020 science WPs that describe the COSI science in depth.
△ Less
Submitted 12 August, 2019;
originally announced August 2019.
-
Strontium Iodide Radiation Instrument (SIRI) -- Early On-Orbit Results
Authors:
Lee J. Mitchell,
Bernard F. Phlips,
J. Eric Grove,
Theodore Finne,
Mary Johnson-Rambert,
W. Neil Johnson
Abstract:
The Strontium Iodide Radiation Instrument (SIRI) is a single detector, gamma-ray spectrometer designed to space-qualify the new scintillation detector material europium-doped strontium iodide (SrI2:Eu) and new silicon photomultiplier (SiPM) technology. SIRI covers the energy range from 0.04-8 MeV and was launched into 600 km sun-synchronous orbit on Dec 3, 2018 onboard STPSat5 with a one-year miss…
▽ More
The Strontium Iodide Radiation Instrument (SIRI) is a single detector, gamma-ray spectrometer designed to space-qualify the new scintillation detector material europium-doped strontium iodide (SrI2:Eu) and new silicon photomultiplier (SiPM) technology. SIRI covers the energy range from 0.04-8 MeV and was launched into 600 km sun-synchronous orbit on Dec 3, 2018 onboard STPSat5 with a one-year mission to investigate the detector's response to on-orbit background radiation. The detector has an active volume of 11.6 cm3 and a photo fraction efficiency of 50% at 662 keV for gamma-rays parallel to the long axis of the crystal. Its spectroscopic resolution of 4.3% was measured by the FWHM of the characteristic Cs-137 gamma-ray line at 662 keV. Measured background rates external to the trapped particle regions are 40-50 counts per second for energies greater than 40 keV and are largely the result of short- and long-term activation products generated by transits of the SAA and the continual cosmic-ray bombardment. Rate maps determined from energy cuts of the collected spectral data show the expected contributions from the various trapped particle regions. Early spectra acquired by the instrument show the presence of at least 10 characteristic gamma-ray lines and a beta continuum generated by activation products within the detector and surrounding materials. As of April 2019, the instrument has acquired over 1000 hours of data and is expected to continue operations until the space vehicle is decommissioned in Dec. 2019. Results indicate SrI2:Eu provides a feasible alternative to traditional sodium iodide and cesium iodide scintillators, especially for missions where a factor-of-two improvement in energy resolution would represent a significant difference in scientific return. To the best of our knowledge, SIRI is the first on-orbit use of SrI2:Eu scintillator with SiPM readouts.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
STROBE-X: X-ray Timing and Spectroscopy on Dynamical Timescales from Microseconds to Years
Authors:
Paul S. Ray,
Zaven Arzoumanian,
David Ballantyne,
Enrico Bozzo,
Soren Brandt,
Laura Brenneman,
Deepto Chakrabarty,
Marc Christophersen,
Alessandra DeRosa,
Marco Feroci,
Keith Gendreau,
Adam Goldstein,
Dieter Hartmann,
Margarita Hernanz,
Peter Jenke,
Erin Kara,
Tom Maccarone,
Michael McDonald,
Michael Nowak,
Bernard Phlips,
Ron Remillard,
Abigail Stevens,
John Tomsick,
Anna Watts,
Colleen Wilson-Hodge
, et al. (134 additional authors not shown)
Abstract:
We present the Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X), a probe-class mission concept selected for study by NASA. It combines huge collecting area, high throughput, broad energy coverage, and excellent spectral and temporal resolution in a single facility. STROBE-X offers an enormous increase in sensitivity for X-ray spectral timing, extending these techniqu…
▽ More
We present the Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X), a probe-class mission concept selected for study by NASA. It combines huge collecting area, high throughput, broad energy coverage, and excellent spectral and temporal resolution in a single facility. STROBE-X offers an enormous increase in sensitivity for X-ray spectral timing, extending these techniques to extragalactic targets for the first time. It is also an agile mission capable of rapid response to transient events, making it an essential X-ray partner facility in the era of time-domain, multi-wavelength, and multi-messenger astronomy. Optimized for study of the most extreme conditions found in the Universe, its key science objectives include: (1) Robustly measuring mass and spin and mapping inner accretion flows across the black hole mass spectrum, from compact stars to intermediate-mass objects to active galactic nuclei. (2) Mapping out the full mass-radius relation of neutron stars using an ensemble of nearly two dozen rotation-powered pulsars and accreting neutron stars, and hence measuring the equation of state for ultradense matter over a much wider range of densities than explored by NICER. (3) Identifying and studying X-ray counterparts (in the post-Swift era) for multiwavelength and multi-messenger transients in the dynamic sky through cross-correlation with gravitational wave interferometers, neutrino observatories, and high-cadence time-domain surveys in other electromagnetic bands. (4) Continuously surveying the dynamic X-ray sky with a large duty cycle and high time resolution to characterize the behavior of X-ray sources over an unprecedentedly vast range of time scales. STROBE-X's formidable capabilities will also enable a broad portfolio of additional science.
△ Less
Submitted 8 March, 2019; v1 submitted 7 March, 2019;
originally announced March 2019.
-
The MERger-event Gamma-Ray (MERGR) Telescope
Authors:
L. J. Mitchell,
J. E. Grove,
B. F. Phlips,
C. C. Cheung,
M. Kerr,
R. S. Woolf,
M. S. Briggs,
J. S. Perkins
Abstract:
We describe the MERger-event Gamma-Ray (MERGR) Telescope intended for deployment by ~2021. MERGR will cover from 20 keV to 2 MeV with a wide field of view (6 sr) using nineteen gamma-ray detectors arranged on a section of a sphere. The telescope will work as a standalone system or as part of a network of sensors, to increase by ~50% the current sky coverage to detect short Gamma-Ray Burst (SGRB) c…
▽ More
We describe the MERger-event Gamma-Ray (MERGR) Telescope intended for deployment by ~2021. MERGR will cover from 20 keV to 2 MeV with a wide field of view (6 sr) using nineteen gamma-ray detectors arranged on a section of a sphere. The telescope will work as a standalone system or as part of a network of sensors, to increase by ~50% the current sky coverage to detect short Gamma-Ray Burst (SGRB) counterparts to neutron-star binary mergers within the ~200 Mpc range of gravitational wave detectors in the early 2020's. Inflight software will provide realtime burst detections with mean localization uncertainties of 6 deg for a photon fluence of 5 ph cm^-2 (the mean fluence of Fermi-GBM SGRBs) and <3 deg for the brightest ~5% of SGRBs to enable rapid multi-wavelength follow-up to identify a host galaxy and its redshift. To minimize cost and time to first light, MERGR is directly derived from demonstrators designed and built at NRL for the DoD Space Test Program (STP). We argue that the deployment of a network that provides all-sky coverage for SGRB detection is of immediate urgency to the multi-messenger astrophysics community.
△ Less
Submitted 9 November, 2017;
originally announced November 2017.
-
The Advanced X-ray Timing Array (AXTAR): A US MIDEX Mission Concept
Authors:
Paul S. Ray,
Bernard F. Phlips,
Kent S. Wood,
Deepto Chakrabarty,
Ronald A. Remillard,
Colleen A. Wilson-Hodge
Abstract:
AXTAR is a NASA MIDEX mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at the natural time scales…
▽ More
AXTAR is a NASA MIDEX mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at the natural time scales of neutron star surfaces and black hole event horizons, thus probing the physics of ultradense matter, strongly curved spacetimes, and intense magnetic fields. AXTAR's main instrument is a collimated, thick Si pixel detector with 2-50 keV coverage and over 3 square meters effective area. For timing observations of accreting neutron stars and black holes, AXTAR provides at least a factor of five improvement in sensitivity over the RXTE PCA. AXTAR also carries a sensitive sky monitor that acts as a trigger for pointed observations of X-ray transients in addition to providing high duty cycle monitoring of the X-ray sky. We review the science goals and design choices that face a next generation timing mission. We then describe the technical concept for AXTAR and summarize a preliminary mission design study at the NASA/MSFC Advanced Concepts Office.
△ Less
Submitted 6 September, 2011;
originally announced September 2011.
-
AXTAR: Mission Design Concept
Authors:
Paul S. Ray,
Deepto Chakrabarty,
Colleen A. Wilson-Hodge,
Bernard F. Phlips,
Ronald A. Remillard,
Alan M. Levine,
Kent S. Wood,
Michael T. Wolff,
Chul S. Gwon,
Tod E. Strohmayer,
Michael Baysinger,
Michael S. Briggs,
Peter Capizzo,
Leo Fabisinski,
Randall C. Hopkins,
Linda S. Hornsby,
Les Johnson,
C. Dauphne Maples,
Janie H. Miernik,
Dan Thomas,
Gianluigi De Geronimo
Abstract:
The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at…
▽ More
The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for submillisecond timing of bright Galactic X-ray sources in order to study phenomena at the natural time scales of neutron star surfaces and black hole event horizons, thus probing the physics of ultradense matter, strongly curved spacetimes, and intense magnetic fields. AXTAR's main instrument, the Large Area Timing Array (LATA) is a collimated instrument with 2-50 keV coverage and over 3 square meters effective area. The LATA is made up of an array of supermodules that house 2-mm thick silicon pixel detectors. AXTAR will provide a significant improvement in effective area (a factor of 7 at 4 keV and a factor of 36 at 30 keV) over the RXTE PCA. AXTAR will also carry a sensitive Sky Monitor (SM) that acts as a trigger for pointed observations of X-ray transients in addition to providing high duty cycle monitoring of the X-ray sky. We review the science goals and technical concept for AXTAR and present results from a preliminary mission design study.
△ Less
Submitted 6 July, 2010;
originally announced July 2010.
-
DUAL Gamma-Ray Mission
Authors:
S. Boggs,
C. Wunderer,
P. von Ballmoos,
T. Takahashi,
N. Gehrels,
J. Tueller,
M. Baring,
J. Beacom,
R. Diehl,
J. Greiner,
E. Grove,
D. Hartmann,
M. Hernanz,
P. Jean,
N. Johnson,
G. Kanbach,
M. Kippen,
J. Knödlseder,
M. Leising,
G. Madejski,
M. McConnell,
P. Milne,
K. Motohide,
K. Nakazawa,
U. Oberlack
, et al. (8 additional authors not shown)
Abstract:
Gamma-ray astronomy presents an extraordinary scientific potential for the study of the most powerful sources and the most violent events in the Universe. In order to take full advantage of this potential, the next generation of instrumentation for this domain will have to achieve an improvement in sensitivity over present technologies of at least an order of magnitude. The DUAL mission concept ta…
▽ More
Gamma-ray astronomy presents an extraordinary scientific potential for the study of the most powerful sources and the most violent events in the Universe. In order to take full advantage of this potential, the next generation of instrumentation for this domain will have to achieve an improvement in sensitivity over present technologies of at least an order of magnitude. The DUAL mission concept takes up this challenge in two complementary ways: a very long observation of the entire sky, combined with a large collection area for simultaneous observations of Type Ia SNe. While the Wide-Field Compton Telescope (WCT) accumulates data from the full gamma-ray sky (0.1-10 MeV) over the entire mission lifetime, the Laue-Lens Telescope (LLT) focuses on 56Co emission from SNe Ia (0.8-0.9 MeV), collecting gamma-rays from its large area crystal lens onto the WCT. Two separated spacecraft flying in formation will maintain the DUAL payloads at the lens' focal distance.
△ Less
Submitted 10 June, 2010;
originally announced June 2010.
-
The Advanced Compton Telescope Mission
Authors:
Steven E. Boggs,
James Kurfess,
James Ryan,
Elena Aprile,
Neil Gehrels,
Marc Kippen,
Mark Leising,
Uwe Oberlack,
Cornelia Wunderer,
Allen Zych,
Peter Bloser,
Michael Harris,
Andrew Hoover,
Alexei Klimenk,
Dan Kocevski,
Mark McConnell,
Peter Milne,
Elena I. Novikova,
Bernard Phlips,
Mark Polsen,
Steven Sturner,
Derek Tournear,
Georg Weidenspointner,
Eric Wulf,
Andreas Zoglauer
, et al. (8 additional authors not shown)
Abstract:
The Advanced Compton Telescope (ACT), the next major step in gamma-ray astronomy, will probe the fires where chemical elements are formed by enabling high-resolution spectroscopy of nuclear emission from supernova explosions. During the past two years, our collaboration has been undertaking a NASA mission concept study for ACT. This study was designed to (1) transform the key scientific objectiv…
▽ More
The Advanced Compton Telescope (ACT), the next major step in gamma-ray astronomy, will probe the fires where chemical elements are formed by enabling high-resolution spectroscopy of nuclear emission from supernova explosions. During the past two years, our collaboration has been undertaking a NASA mission concept study for ACT. This study was designed to (1) transform the key scientific objectives into specific instrument requirements, (2) to identify the most promising technologies to meet those requirements, and (3) to design a viable mission concept for this instrument. We present the results of this study, including scientific goals and expected performance, mission design, and technology recommendations.
△ Less
Submitted 24 August, 2006;
originally announced August 2006.
-
The Soft Gamma-Ray Spectral Variability of Cygnus X-1
Authors:
M. L. McConnell,
A. A. Zdziarski,
K. Bennett,
H. Bloemen,
W. Collmar,
W. Hermsen,
L. Kuiper,
W. Paciesas,
B. F. Phlips,
J. Poutanen,
J. M. Ryan,
V. Schoenfelder,
H. Steinle,
A. W. Strong
Abstract:
We have used observations of Cygnus X-1 from the Compton Gamma-Ray Observatory (CGRO) and BeppoSAX to study the variation in the MeV gamma-ray emission between the hard and soft spectral states, using spectra that cover the energy range 20 keV up to 10 MeV. These data provide evidence for significant spectral variability at energies above 1 MeV. In particular, whereas the hard X-ray flux decreas…
▽ More
We have used observations of Cygnus X-1 from the Compton Gamma-Ray Observatory (CGRO) and BeppoSAX to study the variation in the MeV gamma-ray emission between the hard and soft spectral states, using spectra that cover the energy range 20 keV up to 10 MeV. These data provide evidence for significant spectral variability at energies above 1 MeV. In particular, whereas the hard X-ray flux decreases during the soft state, the flux at energies above 1 MeV increases, resulting in a significantly harder gamma-ray spectrum at energies above 1 MeV. This behavior is consistent with the general picture of galactic black hole candidates having two distinct spectral forms at soft gamma-ray energies. These data extend this picture, for the first time, to energies above 1 MeV. We have used two different hybrid thermal/non-thermal Comptonization models to fit broad band spectral data obtained in both the hard and soft spectral states. These fits provide a quantitative estimate of the electron distribution and allow us to probe the physical changes that take place during transitions between the low and high X-ray states. We find that there is a significant increase (by a factor of ~4) in the bolometric luminosity as the source moves from the hard state to the soft state. Furthermore, the presence of a non-thermal tail in the Comptonizing electron distribution provides significant constraints on the magnetic field in the source region.
△ Less
Submitted 25 February, 2002; v1 submitted 13 December, 2001;
originally announced December 2001.
-
Gamma-Ray Spectral Variability of Cygnus X-1
Authors:
M. L. McConnell,
K. Bennett,
H. Bloemen,
W. Collmar,
W. Hermsen,
L. Kuiper,
W. Paciesas,
B. Phlips,
J. Poutanen,
J. M. Ryan,
V. Schoenfelder,
H. Steinle,
A. W. Strong,
A. A. Zdziarski
Abstract:
We have used observations from CGRO to study the variation in the MeV emission of Cygnus X-1 between its low and high X-ray states. These data provide a measurement of the spectral variability above 1 MeV. The high state MeV spectrum is found to be much harder than that of the low state MeV spectrum. In particular, the power-law emission seen at hard X-ray energies in the high state spectrum (wi…
▽ More
We have used observations from CGRO to study the variation in the MeV emission of Cygnus X-1 between its low and high X-ray states. These data provide a measurement of the spectral variability above 1 MeV. The high state MeV spectrum is found to be much harder than that of the low state MeV spectrum. In particular, the power-law emission seen at hard X-ray energies in the high state spectrum (with a photon spectral index of 2.6) is found to extend out to at least 5 MeV, with no evidence for any cutoff. Here we present the data and describe our efforts to model both the low state and high state spectra using a hybrid thermal/nonthermal model in which the emission results from the Comptonization of an electron population that consists of both a thermal and nonthermal component.
△ Less
Submitted 4 June, 2001;
originally announced June 2001.
-
The Spectral Variability of Cygnus X-1 at MeV Energies
Authors:
M. L. McConnell,
K. Bennett,
H. Bloemen,
W. Collmar,
W. Hermsen,
L. Kuiper,
B. Phlips,
J. M. Ryan,
V. Schoenfelder,
H. Steinle,
A. W. Strong
Abstract:
In previous work, we have used data from the first three years of the CGRO mission to assemble a broad-band $γ$-ray spectrum of the galactic black hole candidate Cygnus X-1. Contemporaneous data from the COMPTEL, OSSE and BATSE experiments on CGRO were selected on the basis of the hard X-ray flux (45--140 keV) as measured by BATSE. This provided a spectrum of Cygnus X-1 in its canonical low X-ra…
▽ More
In previous work, we have used data from the first three years of the CGRO mission to assemble a broad-band $γ$-ray spectrum of the galactic black hole candidate Cygnus X-1. Contemporaneous data from the COMPTEL, OSSE and BATSE experiments on CGRO were selected on the basis of the hard X-ray flux (45--140 keV) as measured by BATSE. This provided a spectrum of Cygnus X-1 in its canonical low X-ray state (as measured at energies below 10 keV), covering the energy range from 50 keV to 5 MeV. Here we report on a comparison of this spectrum to a COMPTEL-OSSE spectrum collected during a high X-ray state of Cygnus X-1 (May, 1996). These data provide evidence for significant spectral variability at energies above 1 MeV. In particular, whereas the hard X-ray flux {\it decreases} during the high X-ray state, the flux at energies above 1 MeV {\it increases}, resulting in a significantly harder high energy spectrum. This behavior is consistent with the general picture of galactic black hole candidates having two distinct spectral forms at soft $γ$-ray energies. These data extend this picture, for the first time, to energies above 1 MeV.
△ Less
Submitted 27 January, 2000;
originally announced January 2000.
-
A High Sensitivity Measurement of the MeV Gamma-Ray Spectrum of Cygnus X-1
Authors:
M. L. McConnell,
J. M. Ryan,
W. Collmar,
V. Schoenfelder,
H. Steinle,
A. W. Strong,
H. Bloemen,
W. Hermsen,
L. Kuiper,
K. Bennett,
B. F. Phlips,
J. C. Ling
Abstract:
The Compton Gamma-Ray Observatory (CGRO) has observed the Cygnus region on several occasions since its launch in 1991. The data collected by the COMPTEL experiment on CGRO represent the most sensitive observations to date of Cygnus X-1 in the 0.75-30 MeV range. A spectrum accumulated by COMPTEL over 10 weeks of observation time shows significant evidence for emission extending out to several MeV…
▽ More
The Compton Gamma-Ray Observatory (CGRO) has observed the Cygnus region on several occasions since its launch in 1991. The data collected by the COMPTEL experiment on CGRO represent the most sensitive observations to date of Cygnus X-1 in the 0.75-30 MeV range. A spectrum accumulated by COMPTEL over 10 weeks of observation time shows significant evidence for emission extending out to several MeV. We have combined these data with contemporaneous data from both BATSE and OSSE to produce a broad-band gamma-ray spectrum, corresponding to the low X-ray state of Cygnus X-1, extending from 50 keV up to approximately 5 MeV. Although there is no evidence for any broad line-like emissions in the MeV region, these data further confirm the presence of a hard tail at energies above several hundred keV. In particular, the spectrum at MeV energies can be described as a power-law with a photon spectral index of $α$ = -3.2, with no evidence for a cutoff at high energies. For the 200 keV to 5 MeV spectrum, we provide a quantitative description of the underlying electron spectrum, in the context of a hybrid thermal/non-thermal model for the emission. The electron spectrum can be described by a thermal Maxwellian with a temperature of $kT_e$ = 86 keV and a non-thermal power-law component with a spectral index of $p_e$ = 4.5. The spectral data presented here should provide a useful basis for further theoretical modeling.
△ Less
Submitted 19 June, 2000; v1 submitted 27 January, 2000;
originally announced January 2000.
-
Gamma-Ray Spectral States of Galactic Black Hole Candidates
Authors:
J. E. Grove,
W. N. Johnson,
R. A. Kroeger,
K. McNaron-Brown,
J. G. Skibo,
B. F. Phlips
Abstract:
OSSE has observed seven transient black hole candidates: GRO J0422+32, GX339-4, GRS 1716-249, GRS 1009-45, 4U 1543-47, GRO J1655-40, and GRS 1915+105. Two gamma-ray spectral states are evident and, based on a limited number of contemporaneous X-ray and gamma-ray observations, these states appear to be correlated with X-ray states. The former three objects show hard spectra below 100 keV (photon…
▽ More
OSSE has observed seven transient black hole candidates: GRO J0422+32, GX339-4, GRS 1716-249, GRS 1009-45, 4U 1543-47, GRO J1655-40, and GRS 1915+105. Two gamma-ray spectral states are evident and, based on a limited number of contemporaneous X-ray and gamma-ray observations, these states appear to be correlated with X-ray states. The former three objects show hard spectra below 100 keV (photon number indices Gamma < 2) that are exponentially cut off with folding energy ~100 keV, a spectral form that is consistent with thermal Comptonization. This "breaking gamma-ray state" is the high-energy extension of the X-ray low, hard state. In this state, the majority of the luminosity is above the X-ray band, carried by photons of energy ~100 keV. The latter four objects exhibit a "power-law gamma-ray state" with a relatively soft spectral index (Gamma ~ 2.5-3) and no evidence for a spectral break. For GRO J1655-40, the lower limit on the break energy is 690 keV. GRS 1716-249 exhibits both spectral states, with the power-law state having significantly lower gamma-ray luminosity. The power-law gamma-ray state is associated with the presence of a strong ultrasoft X-ray excess (kT ~ 1 keV), the signature of the X-ray high, soft (or perhaps very high) state. The physical process responsible for the unbroken power law is not well understood, although the spectra are consistent with bulk-motion Comptonization in the convergent accretion flow.
△ Less
Submitted 18 February, 1998;
originally announced February 1998.
-
Simultaneous X-ray and gamma-ray observations of Cyg X-1 in the hard state by Ginga and OSSE
Authors:
Marek Gierlinski,
Andrzej A. Zdziarski,
Chris Done,
W. Neil Johnson,
Ken Ebisawa,
Yoshihiro Ueda,
Francesco Haardt,
Bernard F. Phlips
Abstract:
We present four X-ray/gamma-ray spectra of Cyg X-1 observed in the hard ('low') state simultaneously by Ginga and GRO/OSSE on 1991 July 6. The 3-30 keV Ginga spectra are well represented by power laws with an energy spectral index of alpha~0.6 and a Compton reflection component including a fluorescent Fe K-alpha corresponding to the solid angle of the reflector of ~0.3 times 2 Pi. The overall Gi…
▽ More
We present four X-ray/gamma-ray spectra of Cyg X-1 observed in the hard ('low') state simultaneously by Ginga and GRO/OSSE on 1991 July 6. The 3-30 keV Ginga spectra are well represented by power laws with an energy spectral index of alpha~0.6 and a Compton reflection component including a fluorescent Fe K-alpha corresponding to the solid angle of the reflector of ~0.3 times 2 Pi. The overall Ginga/OSSE spectra can be modelled by repeated Compton scattering in a mildly-relativistic, tau ~1, plasma. However, the high-energy cutoff is steeper than that due to single-temperature thermal Comptonisation. It can be described by a superposition of dominant optically-thin, thermal emission at kT~140 keV and a Wien-like component from an optically-thick plasma at kT~50 keV. The X-ray spectra do not show the presence of an anisotropy break required if thermal Compton scattering takes place in a corona above a cold disc. Also, the flat spectral index shows that the plasma is soft-photon starved, i.e., the luminosity in incident soft X-ray seed photons is very much less than that in the hard X-rays. Furthermore, the observed solid angle of the reflector is significantly less than 2 pi. These facts taken together strongly rule out a disc-corona geometry. Rather, the observed spectra are consistent with a geometry in which the cold accretion disc (which both supplies the seed soft X-rays and reflects hard X-rays) only exists at large radii, while the Comptonising hot plasma is located in an inner region with no cold disc. This hot plasma consists of either pure electron-positron pairs if the source size is ~5 Schwarzschild radii or it contains also protons if the size is larger.
△ Less
Submitted 17 February, 1997; v1 submitted 21 October, 1996;
originally announced October 1996.
-
The first simultaneous X-ray/gamma-ray observations of Cyg X-1 by Ginga and OSSE
Authors:
Marek Gierlinski,
Andrzej A. Zdziarski,
W. Neil Johnson,
Bernard F. Phlips,
Ken Ebisawa,
Chris Done
Abstract:
We present the results of 4 simultaneous observations of Cygnus X-1 by Ginga and OSSE. The X-ray/gamma-ray spectra can be described by an intrinsic continuum and a component due to Compton reflection including an iron K-alpha line. The intrinsic spectrum at X-ray energies is a power-law with a photon spectral index of Gamma=1.6. The intrinsic gamma-ray spectrum can be phenomenologically describe…
▽ More
We present the results of 4 simultaneous observations of Cygnus X-1 by Ginga and OSSE. The X-ray/gamma-ray spectra can be described by an intrinsic continuum and a component due to Compton reflection including an iron K-alpha line. The intrinsic spectrum at X-ray energies is a power-law with a photon spectral index of Gamma=1.6. The intrinsic gamma-ray spectrum can be phenomenologically described by either a power-law without cutoff up to 150 keV, and an exponential cutoff above that energy, or by an exponentially cutoff power law and a second hard component.
△ Less
Submitted 12 December, 1995;
originally announced December 1995.