-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Long-term temporal stability of the DarkSide-50 dark matter detector
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time project…
▽ More
The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. In this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.
△ Less
Submitted 22 May, 2024; v1 submitted 30 November, 2023;
originally announced November 2023.
-
Search for dark matter annual modulation with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range abo…
▽ More
Dark matter induced event rate in an Earth-based detector is predicted to show an annual modulation as a result of the Earth's orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above $40~{\rm eV_{ee}}$, the lowest threshold ever achieved in such a search.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Search for low mass dark matter in DarkSide-50: the bayesian network approach
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
N. Cargioli,
M. Cariello,
M. Carlini,
V. Cataudella
, et al. (119 additional authors not shown)
Abstract:
We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there…
▽ More
We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.
△ Less
Submitted 26 April, 2023; v1 submitted 3 February, 2023;
originally announced February 2023.
-
Search for dark matter particle interactions with electron final states with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella
, et al. (120 additional authors not shown)
Abstract:
We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark pho…
▽ More
We present a search for dark matter particles with sub-GeV/$c^2$ masses whose interactions have final state electrons using the DarkSide-50 experiment's (12306 $\pm$ 184) kg d low-radioactivity liquid argon exposure. By analyzing the ionization signals, we exclude new parameter space for the dark matter-electron cross section $\barσ_e$, the axioelectric coupling constant $g_{Ae}$, and the dark photon kinetic mixing parameter $κ$. We also set the first dark matter direct-detection constraints on the mixing angle $\left|U_{e4}\right|^2$ for keV sterile neutrinos.
△ Less
Submitted 16 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Search for dark matter-nucleon interactions via Migdal effect with DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
M. D. Campos,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella
, et al. (121 additional authors not shown)
Abstract:
Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using…
▽ More
Dark matter elastic scattering off nuclei can result in the excitation and ionization of the recoiling atom through the so-called Migdal effect. The energy deposition from the ionization electron adds to the energy deposited by the recoiling nuclear system and allows for the detection of interactions of sub-GeV/c$^2$ mass dark matter. We present new constraints for sub-GeV/c$^2$ dark matter using the dual-phase liquid argon time projection chamber of the DarkSide-50 experiment with an exposure of (12306 $\pm$ 184) kg d. The analysis is based on the ionization signal alone and significantly enhances the sensitivity of DarkSide-50, enabling sensitivity to dark matter with masses down to 40 MeV/c$^2$. Furthermore, it sets the most stringent upper limit on the spin independent dark matter nucleon cross section for masses below $3.6$ GeV/c$^2$.
△ Less
Submitted 16 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Search for low-mass dark matter WIMPs with 12 ton-day exposure of DarkSide-50
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
V. Cataudella,
P. Cavalcante
, et al. (119 additional authors not shown)
Abstract:
We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately…
▽ More
We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from more accurate calibration of the detector response, improved background model, and better determination of systematic uncertainties, allowing us to accurately model the background rate and spectra down to 0.06 keV$_{er}$. A 90% C.L. exclusion limit for the spin-independent cross section of 3 GeV/c$^2$ mass WIMP on nucleons is set at 6$\times$10$^{-43}$ cm$^2$, about a factor 10 better than the previous DarkSide-50 limit. This analysis extends the exclusion region for spin-independent dark matter interactions below the current experimental constraints in the $[1.2, 3.6]$ GeV/c$^2$ WIMP mass range.
△ Less
Submitted 24 February, 2023; v1 submitted 25 July, 2022;
originally announced July 2022.
-
Characterization of the scintillation time response of liquid argon detectors for dark matter search
Authors:
P. Agnes,
S. De Cecco,
A. Fan,
G. Fiorillo,
D. Franco,
C. Galbiati,
C. Giganti,
G. Korga,
M. Lebois,
A. Mandarano,
C. J. Martoff,
L. Pagani,
E. Pantic,
A. Razeto,
A. L. Renshaw,
Q. Riffard,
B. Schlitzer,
A. Tonazzo,
H. Wang,
J. N. Wilson
Abstract:
The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chamber…
▽ More
The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. In this work, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.
△ Less
Submitted 11 October, 2021;
originally announced October 2021.
-
Searching for solar KDAR with DUNE
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
P. Amedo,
J. Anderson,
C. Andreopoulos,
M. Andreotti,
M. P. Andrews
, et al. (1157 additional authors not shown)
Abstract:
The observation of 236 MeV muon neutrinos from kaon-decay-at-rest (KDAR) originating in the core of the Sun would provide a unique signature of dark matter annihilation. Since excellent angle and energy reconstruction are necessary to detect this monoenergetic, directional neutrino flux, DUNE with its vast volume and reconstruction capabilities, is a promising candidate for a KDAR neutrino search.…
▽ More
The observation of 236 MeV muon neutrinos from kaon-decay-at-rest (KDAR) originating in the core of the Sun would provide a unique signature of dark matter annihilation. Since excellent angle and energy reconstruction are necessary to detect this monoenergetic, directional neutrino flux, DUNE with its vast volume and reconstruction capabilities, is a promising candidate for a KDAR neutrino search. In this work, we evaluate the proposed KDAR neutrino search strategies by realistically modeling both neutrino-nucleus interactions and the response of DUNE. We find that, although reconstruction of the neutrino energy and direction is difficult with current techniques in the relevant energy range, the superb energy resolution, angular resolution, and particle identification offered by DUNE can still permit great signal/background discrimination. Moreover, there are non-standard scenarios in which searches at DUNE for KDAR in the Sun can probe dark matter interactions.
△ Less
Submitted 26 October, 2021; v1 submitted 19 July, 2021;
originally announced July 2021.
-
Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50
Authors:
The DarkSide collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella,
P. Cavalcante
, et al. (114 additional authors not shown)
Abstract:
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionizat…
▽ More
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c$^2$ mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to $\sim$180~eV$_{er}$, exploiting $^{37}$Ar and $^{39}$Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Moreover, we present a model-dependent determination of the ionization response to nuclear recoils down to $\sim$500~eV$_{nr}$, the lowest ever achieved in liquid argon, using \textit{in situ} neutron calibration sources and external datasets from neutron beam experiments.
△ Less
Submitted 15 September, 2021; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Separating $^{39}$Ar from $^{40}$Ar by cryogenic distillation with Aria for dark matter searches
Authors:
DarkSide Collaboration,
P. Agnes,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
M. Arba,
P. Arpaia,
S. Arcelli,
M. Ave,
I. Ch. Avetissov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
A. Bondar,
W. M. Bonivento,
E. Borisova
, et al. (287 additional authors not shown)
Abstract:
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. Aria was designed to reduce the isotopi…
▽ More
The Aria project consists of a plant, hosting a 350 m cryogenic isotopic distillation column, the tallest ever built, which is currently in the installation phase in a mine shaft at Carbosulcis S.p.A., Nuraxi-Figus (SU), Italy. Aria is one of the pillars of the argon dark-matter search experimental program, lead by the Global Argon Dark Matter Collaboration. Aria was designed to reduce the isotopic abundance of $^{39}$Ar, a $β$-emitter of cosmogenic origin, whose activity poses background and pile-up concerns in the detectors, in the argon used for the dark-matter searches, the so-called Underground Argon (UAr). In this paper, we discuss the requirements, design, construction, tests, and projected performance of the plant for the isotopic cryogenic distillation of argon. We also present the successful results of isotopic cryogenic distillation of nitrogen with a prototype plant, operating the column at total reflux.
△ Less
Submitted 23 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Sensitivity of future liquid argon dark matter search experiments to core-collapse supernova neutrinos
Authors:
P. Agnes,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
S. Arcelli,
M. Ave,
I. Ch. Avetissov,
R. I. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
V. Barbarian,
A. Barrado Olmedo,
P. Barrillon,
A. Basco,
G. Batignani,
A. Bondar,
W. M. Bonivento,
E. Borisova,
B. Bottino,
M. G. Boulay,
G. Buccino
, et al. (251 additional authors not shown)
Abstract:
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and AR…
▽ More
Future liquid-argon DarkSide-20k and ARGO detectors, designed for direct dark matter search, will be sensitive also to core-collapse supernova neutrinos, via coherent elastic neutrino-nucleus scattering. This interaction channel is flavor-insensitive with a high-cross section, enabling for a high-statistics neutrino detection with target masses of $\sim$50~t and $\sim$360~t for DarkSide-20k and ARGO, respectively.
Thanks to the low-energy threshold of $\sim$0.5~keV$_{nr}$ achievable by exploiting the ionization channel, DarkSide-20k and ARGO have the potential to discover supernova bursts throughout our galaxy and up to the Small Magellanic Cloud, respectively, assuming a 11-M$_{\odot}$ progenitor star. We report also on the sensitivity to the neutronization burst, whose electron neutrino flux is suppressed by oscillations when detected via charged current and elastic scattering. Finally, the accuracies in the reconstruction of the average and total neutrino energy in the different phases of the supernova burst, as well as its time profile, are also discussed, taking into account the expected background and the detector response.
△ Less
Submitted 31 December, 2020; v1 submitted 16 November, 2020;
originally announced November 2020.
-
Supernova Neutrino Burst Detection with the Deep Underground Neutrino Experiment
Authors:
DUNE collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
G. Adamov,
D. Adams,
M. Adinolfi,
Z. Ahmad,
J. Ahmed,
T. Alion,
S. Alonso Monsalve,
C. Alt,
J. Anderson,
C. Andreopoulos,
M. P. Andrews,
F. Andrianala,
S. Andringa,
A. Ankowski,
M. Antonova,
S. Antusch,
A. Aranda-Fernandez,
A. Ariga,
L. O. Arnold,
M. A. Arroyave,
J. Asaadi
, et al. (949 additional authors not shown)
Abstract:
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The gen…
▽ More
The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The general capabilities of DUNE for neutrino detection in the relevant few- to few-tens-of-MeV neutrino energy range will be described. As an example, DUNE's ability to constrain the $ν_e$ spectral parameters of the neutrino burst will be considered.
△ Less
Submitted 29 May, 2021; v1 submitted 15 August, 2020;
originally announced August 2020.
-
SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range
Authors:
The DarkSide collaboration,
C. E. Aalseth,
S. Abdelhakim,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
V. Barbaryan,
A. Barrado Olmedo,
G. Batignani
, et al. (290 additional authors not shown)
Abstract:
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the…
▽ More
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.
△ Less
Submitted 26 February, 2021; v1 submitted 4 April, 2020;
originally announced April 2020.
-
Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon
Authors:
The DarkSide Collaboration,
C. E. Aalseth,
S. Abdelhakim,
F. Acerbi,
P. Agnes,
R. Ajaj,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Amaudruz,
F. Ameli,
J. Anstey,
P. Antonioli,
M. Arba,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
P. Arpaia,
D. M. Asner,
A. Asunskis,
M. Ave,
H. O. Back,
A. Barrado Olmedo,
G. Batignani
, et al. (306 additional authors not shown)
Abstract:
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioa…
▽ More
Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
Measurement of the ion fraction and mobility of $^{218}$Po produced in $^{222}$Rn decays in liquid argon
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella
, et al. (141 additional authors not shown)
Abstract:
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)…
▽ More
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)$\times$10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
△ Less
Submitted 28 October, 2019; v1 submitted 22 July, 2019;
originally announced July 2019.
-
DarkSide-50 532-day Dark Matter Search with Low-Radioactivity Argon
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (150 additional authors not shown)
Abstract:
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark ma…
▽ More
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon time projection chamber operating at Laboratori Nazionali del Gran Sasso. This paper reports on the blind analysis of a (16,660+-270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We find no events in the dark matter selection box and set a 90% C.L. upper limit on the dark matter-nucleon spin-independent cross section of 1.14E-44 cm^2 (3.78E-44 cm^2, 3.43E-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10 TeV/c^2).
△ Less
Submitted 19 November, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Constraints on Sub-GeV Dark Matter-Electron Scattering from the DarkSide-50 Experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati
, et al. (171 additional authors not shown)
Abstract:
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
We present new constraints on sub-GeV dark matter particles scattering off electrons in argon based on an analysis of ionization signal data from the DarkSide-50 detector.
△ Less
Submitted 3 October, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Low-Mass Dark Matter Search with the DarkSide-50 Experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
G. R. Araujo,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati
, et al. (170 additional authors not shown)
Abstract:
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detecto…
▽ More
We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.
△ Less
Submitted 28 August, 2018; v1 submitted 20 February, 2018;
originally announced February 2018.
-
Solar neutrino detection in a large volume double-phase liquid argon experiment
Authors:
D. Franco,
C. Giganti,
P. Agnes,
L. Agostino,
B. Bottino,
N. Canci,
S. Davini,
S. De Cecco,
A. Fan,
G. Fiorillo,
C. Galbiati,
A. M. Goretti,
E. V. Hungerford,
Al. Ianni,
An. Ianni,
C. Jollet,
L. Marini,
C. J. Martoff,
A. Meregaglia,
L. Pagani,
M. Pallavicini,
E. Pantic,
A. Pocar,
M. Razeti,
A. L. Renshaw
, et al. (7 additional authors not shown)
Abstract:
Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with go…
▽ More
Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the "neutrino floor" (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ~15% precision, and significantly improve the precision of the 7Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.
△ Less
Submitted 1 August, 2016; v1 submitted 14 October, 2015;
originally announced October 2015.
-
Results from the first use of low radioactivity argon in a dark matter search
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the La…
▽ More
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
△ Less
Submitted 13 April, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
Authors:
The XENON Collaboration,
E. Aprile,
F. Agostini,
M. Alfonsi,
L. Arazi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Coderre,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau
, et al. (76 additional authors not shown)
Abstract:
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic re…
▽ More
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2 GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4 sigma confidence level, mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
△ Less
Submitted 28 July, 2015;
originally announced July 2015.
-
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
Authors:
E. Aprile,
F. Agostini,
M. Alfonsi,
L. Arazi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
D. Coderre,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowksi
, et al. (73 additional authors not shown)
Abstract:
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experime…
▽ More
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
△ Less
Submitted 26 March, 2015;
originally announced March 2015.
-
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
Authors:
The DarkSide Collaboration,
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo
, et al. (121 additional authors not shown)
Abstract:
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del…
▽ More
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions.
△ Less
Submitted 22 January, 2015; v1 submitted 9 December, 2014;
originally announced December 2014.
-
First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
Authors:
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo,
M. D'Incecco
, et al. (121 additional authors not shown)
Abstract:
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid sci…
▽ More
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We report here the null results of a dark matter search for a (1422+-67) kg d exposure with an atmospheric argon fill. This is the most sensitive dark matter search performed with an argon target, corresponding to a 90% CL upper limit on the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP mass of 100 GeV/c^2.
△ Less
Submitted 27 February, 2015; v1 submitted 2 October, 2014;
originally announced October 2014.
-
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
Authors:
E. Aprile,
F. Agostini,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni
, et al. (66 additional authors not shown)
Abstract:
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for W…
▽ More
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of $\sim$10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons ($>99.5%$) and showers of secondary particles from muon interactions in the rock ($>70%$). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
△ Less
Submitted 25 February, 2015; v1 submitted 9 June, 2014;
originally announced June 2014.
-
First Axion Results from the XENON100 Experiment
Authors:
The XENON100 Collaboration,
E. Aprile,
F. Agostini,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni
, et al. (65 additional authors not shown)
Abstract:
We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been probed by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90\% C…
▽ More
We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been probed by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For axion-like-particles, under the assumption that they constitute the whole abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than $1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set the best limit to date as well.
△ Less
Submitted 22 December, 2016; v1 submitted 5 April, 2014;
originally announced April 2014.
-
Observation and applications of single-electron charge signals in the XENON100 experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (55 additional authors not shown)
Abstract:
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector…
▽ More
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
△ Less
Submitted 28 January, 2014; v1 submitted 5 November, 2013;
originally announced November 2013.
-
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Authors:
P. Cushman,
C. Galbiati,
D. N. McKinsey,
H. Robertson,
T. M. P. Tait,
D. Bauer,
A. Borgland,
B. Cabrera,
F. Calaprice,
J. Cooley,
T. Empl,
R. Essig,
E. Figueroa-Feliciano,
R. Gaitskell,
S. Golwala,
J. Hall,
R. Hill,
A. Hime,
E. Hoppe,
L. Hsu,
E. Hungerford,
R. Jacobsen,
M. Kelsey,
R. F. Lang,
W. H. Lippincott
, et al. (24 additional authors not shown)
Abstract:
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter spa…
▽ More
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
△ Less
Submitted 3 November, 2013; v1 submitted 30 October, 2013;
originally announced October 2013.
-
The neutron background of the XENON100 dark matter experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione
, et al. (52 additional authors not shown)
Abstract:
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($α$,n) and spontaneous fission re…
▽ More
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($α$,n) and spontaneous fission reactions due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively, and conclude that they do not limit the sensitivity of the experiment.
△ Less
Submitted 2 September, 2013; v1 submitted 10 June, 2013;
originally announced June 2013.
-
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
Authors:
The XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori
, et al. (58 additional authors not shown)
Abstract:
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A ve…
▽ More
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.
△ Less
Submitted 18 July, 2013; v1 submitted 4 April, 2013;
originally announced April 2013.
-
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
Authors:
XENON100 collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (53 additional authors not shown)
Abstract:
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to th…
▽ More
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x 10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
△ Less
Submitted 29 January, 2013; v1 submitted 28 January, 2013;
originally announced January 2013.
-
The distributed Slow Control System of the XENON100 Experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. M. Bruno,
R. Budnik,
M. Le Calloch,
J. M. Cardoso,
W. -T. Chen,
B. Choi,
H. Contreras,
J. -P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione,
F. Gao,
M. Garbini
, et al. (50 additional authors not shown)
Abstract:
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature…
▽ More
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
Authors:
The XENON Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (52 additional authors not shown)
Abstract:
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the ratio…
▽ More
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.
△ Less
Submitted 28 August, 2012;
originally announced August 2012.
-
Dark Matter Results from 225 Live Days of XENON100 Data
Authors:
XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (53 additional authors not shown)
Abstract:
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence…
▽ More
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on the spin-independent elastic WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2 and 90% confidence level.
△ Less
Submitted 20 March, 2013; v1 submitted 25 July, 2012;
originally announced July 2012.
-
Analysis of the XENON100 Dark Matter Search Data
Authors:
The XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. B. Cline,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione,
F. Gao
, et al. (49 additional authors not shown)
Abstract:
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have…
▽ More
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.
△ Less
Submitted 14 October, 2013; v1 submitted 14 July, 2012;
originally announced July 2012.
-
Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches
Authors:
T. Alexander,
D. Alton,
K. Arisaka,
H. O. Back,
P. Beltrame,
J. Benziger,
G. Bonfini,
A. Brigatti,
J. Brodsky,
L. Cadonati,
F. Calaprice,
A. Candela,
H. Cao,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
D. Cline,
A. G. Cocco,
C. Condon,
D. D'Angelo,
S. Davini,
E. De Haas,
A. Derbin,
G. Di Pietro,
I. Dratchnev
, et al. (97 additional authors not shown)
Abstract:
As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-r…
▽ More
As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.
△ Less
Submitted 14 August, 2013; v1 submitted 27 April, 2012;
originally announced April 2012.
-
The XENON100 Dark Matter Experiment
Authors:
XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
E. Brown,
J. M. R. Cardoso,
B. Choi,
D. Cline,
S. Fattori,
A. D. Ferella,
K. L. Giboni,
A. Kish,
C. W. Lam,
R. F. Lang,
K. E. Lim,
J. A. M. Lopes,
T. Marrodan Undagoitia,
Y. Mei,
A. J. Melgarejo Fernandez,
K. Ni,
U. Oberlack,
S. E. A. Orrigo
, et al. (11 additional authors not shown)
Abstract:
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science ru…
▽ More
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of σ= 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
△ Less
Submitted 8 February, 2012; v1 submitted 11 July, 2011;
originally announced July 2011.
-
Studies of a three-stage dark matter and neutrino observatory based on multi-ton combinations of liquid xenon and liquid argon detectors
Authors:
K. Arisaka,
P. Beltrame,
C. W. Lam,
P. F. Smith,
C. Ghag,
D. B. Cline,
K. Lung,
Y. Meng,
E. Pantic,
P. R. Scovell,
A. Teymourian,
H. Wang
Abstract:
We study a three stage dark matter and neutrino observatory based on multi-ton two-phase liquid Xe and Ar detectors with sufficiently low backgrounds to be sensitive to WIMP dark matter interaction cross sections down to 10E-47 cm^2, and to provide both identification and two independent measurements of the WIMP mass through the use of the two target elements in a 5:1 mass ratio, giving an expecte…
▽ More
We study a three stage dark matter and neutrino observatory based on multi-ton two-phase liquid Xe and Ar detectors with sufficiently low backgrounds to be sensitive to WIMP dark matter interaction cross sections down to 10E-47 cm^2, and to provide both identification and two independent measurements of the WIMP mass through the use of the two target elements in a 5:1 mass ratio, giving an expected similarity of event numbers. The same detection systems will also allow measurement of the pp solar neutrino spectrum, the neutrino flux and temperature from a Galactic supernova, and neutrinoless double beta decay of 136Xe to the lifetime level of 10E27 - 10E28 y corresponding to the Majorana mass predicted from current neutrino oscillation data. The proposed scheme would be operated in three stages G2, G3, G4, beginning with fiducial masses 1-ton Xe + 5-ton Ar (G2), progressing to 10-ton Xe + 50-ton Ar (G3) then, dependent on results and performance of the latter, expandable to 100-ton Xe + 500-ton Ar (G4). This method of scale-up offers the advantage of utilizing the Ar vessel and ancillary systems of one stage for the Xe detector of the succeeding stage, requiring only one new detector vessel at each stage. Simulations show the feasibility of reducing or rejecting all external and internal background levels to a level <1 events per year for each succeeding mass level, by utilizing an increasing outer thickness of target material as self-shielding. The system would, with increasing mass scale, become increasingly sensitive to annual signal modulation, the agreement of Xe and Ar results confirming the Galactic origin of the signal. Dark matter sensitivities for spin-dependent and inelastic interactions are also included, and we conclude with a discussion of possible further gains from the use of Xe/Ar mixtures.
△ Less
Submitted 15 April, 2012; v1 submitted 7 July, 2011;
originally announced July 2011.
-
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
Authors:
XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
K. Bokeloh,
E. Brown,
T. Bruch,
G. Bruno,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
E. Duchovni,
S. Fattori,
A. D. Ferella,
F. Gao,
K. -L. Giboni,
E. Gross,
A. Kish,
C. W. Lam,
J. Lamblin,
R. F. Lang
, et al. (30 additional authors not shown)
Abstract:
The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we presen…
▽ More
The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.
△ Less
Submitted 9 September, 2011; v1 submitted 15 April, 2011;
originally announced April 2011.
-
Dark Matter Results from 100 Live Days of XENON100 Data
Authors:
XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
K. Bokeloh,
E. Brown,
T. Bruch,
G. Bruno,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
E. Duchovni,
S. Fattori,
A. D. Ferella,
F. Gao,
K. -L. Giboni,
E. Gross,
A. Kish,
C. W. Lam,
J. Lamblin,
R. F. Lang
, et al. (30 additional authors not shown)
Abstract:
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiduc…
▽ More
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.
△ Less
Submitted 7 September, 2011; v1 submitted 13 April, 2011;
originally announced April 2011.
-
Characterization of the QUartz Photon Intensifying Detector (QUPID) for Noble Liquid Detectors
Authors:
A. Teymourian,
D. Aharoni,
L. Baudis,
P. Beltrame,
E. Brown,
D. Cline,
A. D. Ferella,
A. Fukasawa,
C. W. Lam,
T. Lim,
K. Lung,
Y. Meng,
S. Muramatsu,
E. Pantic,
M. Suyama,
H. Wang,
K. Arisaka
Abstract:
Dark Matter and Double Beta Decay experiments require extremely low radioactivity within the detector materials. For this purpose, the University of California, Los Angeles and Hamamatsu Photonics have developed the QUartz Photon Intensifying Detector (QUPID), an ultra-low background photodetector based on the Hybrid Avalanche Photo Diode (HAPD) and entirely made of ultraclean synthetic fused sili…
▽ More
Dark Matter and Double Beta Decay experiments require extremely low radioactivity within the detector materials. For this purpose, the University of California, Los Angeles and Hamamatsu Photonics have developed the QUartz Photon Intensifying Detector (QUPID), an ultra-low background photodetector based on the Hybrid Avalanche Photo Diode (HAPD) and entirely made of ultraclean synthetic fused silica. In this work we present the basic concept of the QUPID and the testing measurements on QUPIDs from the first production line. Screening of radioactivity at the Gator facility in the Laboratori Nazionali del Gran Sasso has shown that the QUPIDs safely fulfill the low radioactive contamination requirements for the next generation zero background experiments set by Monte Carlo simulations. The quantum efficiency of the QUPID at room temperature is > 30% at the xenon scintillation wavelength. At low temperatures, the QUPID shows a leakage current less than 1 nA and a global gain of 10^5. In these conditions, the photocathode and the anode show > 95% linearity up to 1 uA for the cathode and 3 mA for the anode. The photocathode and collection efficiency are uniform to 80% over the entire surface. In parallel with single photon counting capabilities, the QUPIDs have a good timing response: 1.8 +/- 0.1 ns rise time, 2.5 +/- 0.2 ns fall time, 4.20 +/- 0.05 ns pulse width, and 160 +/- 30 ps transit time spread. The QUPIDs have also been tested in a liquid xenon environment, and scintillation light from 57Co and 210Po radioactive sources were observed.
△ Less
Submitted 15 July, 2011; v1 submitted 18 March, 2011;
originally announced March 2011.
-
Likelihood Approach to the First Dark Matter Results from XENON100
Authors:
XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
K. Bokeloh,
E. Brown,
T. Bruch,
J. M. R. Cardoso,
B. Choi,
D. Cline,
E. Duchovni,
S. Fattori,
A. D. Ferella,
K. -L. Giboni,
E. Gross,
A. Kish,
C. W. Lam,
J. Lamblin,
R. F. Lang,
K. E. Lim,
S. Lindemann,
M. Lindner
, et al. (21 additional authors not shown)
Abstract:
Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and ba…
▽ More
Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to make a discovery claim, and the results are derived with a proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows to extract additional information from the data, and place stronger limits on the spin-independent elastic WIMP-nucleon scattering cross-section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
△ Less
Submitted 7 September, 2011; v1 submitted 1 March, 2011;
originally announced March 2011.
-
Study of the electromagnetic background in the XENON100 experiment
Authors:
XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
K. Bokeloh,
E. Brown,
J. M. R. Cardoso,
B. Choi,
D. Cline,
S. Fattori,
A. D. Ferella,
K. -L. Giboni,
A. Kish,
C. W. Lam,
J. Lamblin,
R. F. Lang,
K. E. Lim,
Q. Lin,
S. Lindemann,
M. Lindner,
J. A. M. Lopes,
K. Lung
, et al. (20 additional authors not shown)
Abstract:
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contami…
▽ More
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a detailed geometry together with the measured radioactivity of all detector components, we predict an electronic recoil background in the WIMP-search energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2 events/(kg-day-keV), consistent with the experiment's design goal. The predicted background spectrum is in very good agreement with the data taken during the commissioning of the detector, in Fall 2009.
△ Less
Submitted 21 February, 2013; v1 submitted 20 January, 2011;
originally announced January 2011.
-
First Dark Matter Results from the XENON100 Experiment
Authors:
The XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
E. Brown,
J. M. R. Cardoso,
B. Choi,
D. B. Cline,
S. Fattori,
A. D. Ferella,
K. -L. Giboni,
K. Hugenberg,
A. Kish,
C. W. Lam,
J. Lamblin,
R. F. Lang,
K. E. Lim,
J. A. M. Lopes,
T. Marrodán Undagoitia,
Y. Mei,
A. J. Melgarejo Fernandez,
K. Ni
, et al. (14 additional authors not shown)
Abstract:
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected f…
▽ More
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the pre-defined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs at 90% confidence level. Below 20 GeV/c^2, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.
△ Less
Submitted 1 March, 2011; v1 submitted 3 May, 2010;
originally announced May 2010.
-
Status of the CRESST Dark Matter Search
Authors:
J. Schmaler,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
R. F. Lang,
M. Malek,
R. McGowan
, et al. (16 additional authors not shown)
Abstract:
The CRESST experiment aims for a detection of dark matter in the form of WIMPs. These particles are expected to scatter elastically off the nuclei of a target material, thereby depositing energy on the recoiling nucleus. CRESST uses scintillating CaWO4 crystals as such a target. The energy deposited by an interacting particle is primarily converted to phonons which are detected by transition edg…
▽ More
The CRESST experiment aims for a detection of dark matter in the form of WIMPs. These particles are expected to scatter elastically off the nuclei of a target material, thereby depositing energy on the recoiling nucleus. CRESST uses scintillating CaWO4 crystals as such a target. The energy deposited by an interacting particle is primarily converted to phonons which are detected by transition edge sensors. In addition, a small fraction of the interaction energy is emitted from the crystals in the form of scintillation light which is measured in coincidence with the phonon signal by a separate cryogenic light detector for each target crystal. The ratio of light to phonon energy permits the discrimination between the nuclear recoils expected from WIMPs and events from radioactive backgrounds which primarily lead to electron recoils. CRESST has shown the success of this method in a commissioning run in 2007 and, since then, further investigated possibilities for an even better suppression of backgrounds. Here, we report on a new class of background events observed in the course of this work. The consequences of this observation are discussed and we present the current status of the experiment.
△ Less
Submitted 18 December, 2009;
originally announced December 2009.
-
Composite CaWO4 Detectors for the CRESST-II Experiment
Authors:
M. Kiefer,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
R. F. Lang,
M. Malek,
R. McGowan,
V. B. Mikhailik
, et al. (16 additional authors not shown)
Abstract:
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of…
▽ More
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order to detect WIMPs by elastic scattering off nuclei, generating phononic lattice excitations and scintillation light. The thermometers used in the experiment consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber crystal. The process of evaporation causes a decrease in the scintillation light output. This, together with the need of a big-scale detector production for the upcoming EURECA experiment lead to investigations for producing thermometers on smaller crystals which are glued onto the absorber crystal. In our Run 31 we tested composite detectors for the first time in the Gran Sasso setup. They seem to produce higher light yields as hoped and could provide an additional time based discrimination mechanism for low light yield clamp events.
△ Less
Submitted 1 December, 2009;
originally announced December 2009.
-
Electron and Gamma Background in CRESST Detectors
Authors:
R. F. Lang,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
B. Majorovits,
M. Malek,
R. McGowan
, et al. (17 additional authors not shown)
Abstract:
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by three detectors over many weeks of data taking. Understanding these spectra is mandatory if one wants to further reduce the background level, and allows us to cross-check the calibration of the detec…
▽ More
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle interactions in an ultra low background environment. In this paper, we analyze the background spectra that are recorded by three detectors over many weeks of data taking. Understanding these spectra is mandatory if one wants to further reduce the background level, and allows us to cross-check the calibration of the detectors. We identify a variety of sources, such as intrinsic contaminations due to primordial radioisotopes and cosmogenic activation of the target material. In particular, we detect a 3.6keV X-ray line from the decay of 41-Ca with an activity of (26\pm4)μBq, corresponding to a ratio 41-Ca/40-Ca=(2.2\pm0.3)\times10^{-16}.
△ Less
Submitted 26 May, 2009;
originally announced May 2009.
-
Discrimination of Recoil Backgrounds in Scintillating Calorimeters
Authors:
R. F. Lang,
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
M. Malek,
R. McGowan,
V. B. Mikhailik
, et al. (16 additional authors not shown)
Abstract:
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a way to dis…
▽ More
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event searches. Here, we describe observations related to this alpha decay in the Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a way to discriminate this source of nuclear recoil background by means of a scintillating foil, and demonstrate its effectiveness. This leads to an observable difference in the pulse shape of the light detector, which can be used to tag these events. Differences in pulse shape of the phonon detector between lead and electron recoils are also extracted, opening the window to future additional background suppression techniques based on pulse shape discrimination in such experiments.
△ Less
Submitted 26 March, 2009;
originally announced March 2009.
-
Commissioning Run of the CRESST-II Dark Matter Search
Authors:
G. Angloher,
M. Bauer,
I. Bavykina,
A. Bento,
A. Brown,
C. Bucci,
C. Ciemniak,
C. Coppi,
G. Deuter,
F. von Feilitzsch,
D. Hauff,
S. Henry,
P. Huff,
J. Imber,
S. Ingleby,
C. Isaila,
J. Jochum,
M. Kiefer,
M. Kimmerle,
H. Kraus,
J. -C. Lanfranchi,
R. F. Lang,
B. Majorovits,
M. Malek,
R. McGowan
, et al. (18 additional authors not shown)
Abstract:
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect…
▽ More
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~ 300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to detect the scintillation light from the CaWO_4.Information from light-quenching factor studies allows the definition of a region of the energy-light yield plane which corresponds to tungsten recoils. A neutron test is reported which supports the principle of using the light yield to identify the recoiling nucleus.
Data obtained with two detector modules for a total exposure of 48 kg-days are presented. Judging by the rate of events in the "all nuclear recoils" acceptance region the apparatus shows a factor ~ten improvement with respect to previous results, which we attribute principally to the presence of the neutron shield.
In the "tungsten recoils" acceptance region three events are found, corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark matter flux, coherent or spin independent interactions,then yield a limit for WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
△ Less
Submitted 16 February, 2009; v1 submitted 10 September, 2008;
originally announced September 2008.