Time Assignment System and Its Performance aboard the Hitomi Satellite
Authors:
Yukikatsu Terada,
Sunao Yamaguchi,
Shigenobu Sugimoto,
Taku Inoue,
Souhei Nakaya,
Maika Murakami,
Seiya Yabe,
Kenya Oshimizu,
Mina Ogawa,
Tadayasu Dotani,
Yoshitaka Ishisaki,
Kazuyo Mizushima,
Takashi Kominato,
Hiroaki Mine,
Hiroki Hihara,
Kaori Iwase,
Tomomi Kouzu,
Makoto S. Tashiro,
Chikara Natsukari,
Masanobu Ozaki,
Motohide Kokubun,
Tadayuki Takahashi,
Satoko Kawakami,
Masaru Kasahara,
Susumu Kumagai
, et al. (2 additional authors not shown)
Abstract:
Fast timing capability in X-ray observation of astrophysical objects is one of the key properties for the ASTRO-H (Hitomi) mission. Absolute timing accuracies of 350 micro second or 35 micro second are required to achieve nominal scientific goals or to study fast variabilities of specific sources. The satellite carries a GPS receiver to obtain accurate time information, which is distributed from t…
▽ More
Fast timing capability in X-ray observation of astrophysical objects is one of the key properties for the ASTRO-H (Hitomi) mission. Absolute timing accuracies of 350 micro second or 35 micro second are required to achieve nominal scientific goals or to study fast variabilities of specific sources. The satellite carries a GPS receiver to obtain accurate time information, which is distributed from the central onboard computer through the large and complex SpaceWire network. The details on the time system on the hardware and software design are described. In the distribution of the time information, the propagation delays and jitters affect the timing accuracy. Six other items identified within the timing system will also contribute to absolute time error. These error items have been measured and checked on ground to ensure the time error budgets meet the mission requirements. The overall timing performance in combination with hardware performance, software algorithm, and the orbital determination accuracies, etc, under nominal conditions satisfies the mission requirements of 35 micro second. This work demonstrates key points for space-use instruments in hardware and software designs and calibration measurements for fine timing accuracy on the order of microseconds for mid-sized satellites using the SpaceWire (IEEE1355) network.
△ Less
Submitted 14 December, 2017; v1 submitted 5 December, 2017;
originally announced December 2017.
Hitomi X-ray studies of Giant Radio Pulses from the Crab pulsar
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (179 additional authors not shown)
Abstract:
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance…
▽ More
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance of the Hitomi instruments was confirmed to meet the timing requirement and about 1,000 and 100 GRPs were simultaneously observed at the main and inter-pulse phases, respectively, and we found no apparent correlation between the giant radio pulses and the X-ray emission in either the main or inter-pulse phases.All variations are within the 2 sigma fluctuations of the X-ray fluxes at the pulse peaks, and the 3 sigma upper limits of variations of main- or inter- pulse GRPs are 22\% or 80\% of the peak flux in a 0.20 phase width, respectively, in the 2 -- 300 keV band.The values become 25\% or 110\% for main or inter-pulse GRPs, respectively, when the phase width is restricted into the 0.03 phase.Among the upper limits from the Hitomi satellite, those in the 4.5-10 keV and the 70-300 keV are obtained for the first time, and those in other bands are consistent with previous reports.Numerically, the upper limits of main- and inter-pulse GRPs in the 0.20 phase width are about (2.4 and 9.3) $\times 10^{-11}$ erg cm$^{-2}$, respectively. No significant variability in pulse profiles implies that the GRPs originated from a local place within the magnetosphere and the number of photon-emitting particles temporally increases.However, the results do not statistically rule out variations correlated with the GRPs, because the possible X-ray enhancement may appear due to a $>0.02$\% brightening of the pulse-peak flux under such conditions.
△ Less
Submitted 7 August, 2017; v1 submitted 27 July, 2017;
originally announced July 2017.