-
Flux Calibration of Broadband Far Infrared and Submillimetre Photometric Instruments: Theory and Application to Herschel-SPIRE
Authors:
M. J. Griffin,
C. E. North,
B. Schulz,
A. Amaral-Rogers,
G. Bendo,
J. Bock,
L. Conversi,
A. Conley,
C. D. Dowell,
M. Ferlet,
J. Glenn,
T. Lim,
C. Pearson,
M. Pohlen,
B. Sibthorpe,
L. Spencer,
B. Swinyard,
I. Valtchanov
Abstract:
Photometric instruments operating at far infrared to millimetre wavelengths often have broad spectral passbands (central wavelength/bandwidth ~ 3 or less), especially those operating in space. A broad passband can result in significant variation of the beam profile and aperture efficiency across the passband, effects which thus far have not generally been taken into account in the flux calibration…
▽ More
Photometric instruments operating at far infrared to millimetre wavelengths often have broad spectral passbands (central wavelength/bandwidth ~ 3 or less), especially those operating in space. A broad passband can result in significant variation of the beam profile and aperture efficiency across the passband, effects which thus far have not generally been taken into account in the flux calibration of such instruments. With absolute calibration uncertainties associated with the brightness of primary calibration standards now in the region of 5% or less, variation of the beam properties across the passband can be a significant contributor to the overall calibration accuracy for extended emission. We present a calibration framework which takes such variations into account for both antenna-coupled and absorber-coupled focal plane architectures. The scheme covers point source and extended source cases, and also the intermediate case of a semi-extended source profile. We apply the new method to the Herschel-SPIRE space-borne photometer.
△ Less
Submitted 11 August, 2014; v1 submitted 7 June, 2013;
originally announced June 2013.
-
Flux calibration of the Herschel-SPIRE photometer
Authors:
G. J. Bendo,
M. J. Griffin,
J. J. Bock,
L. Conversi,
C. D. Dowell,
T. Lim,
N. Lu,
C. E. North,
A. Papageorgiou,
C. P. Pearson,
M. Pohlen,
E. T. Polehampton,
B. Schulz,
D. L. Shupe,
B. Sibthorpe,
L. D. Spencer,
B. M. Swinyard,
I. Valtchanov,
C. K. Xu
Abstract:
We describe the procedure used to flux calibrate the three-band submillimetre photometer in the Spectral and Photometric Imaging REceiver (SPIRE) instrument on the Herschel Space Observatory. This includes the equations describing the calibration scheme, a justification for using Neptune as the primary calibration source, a description of the observations and data processing procedures used to der…
▽ More
We describe the procedure used to flux calibrate the three-band submillimetre photometer in the Spectral and Photometric Imaging REceiver (SPIRE) instrument on the Herschel Space Observatory. This includes the equations describing the calibration scheme, a justification for using Neptune as the primary calibration source, a description of the observations and data processing procedures used to derive flux calibration parameters (for converting from voltage to flux density) for every bolometer in each array, an analysis of the error budget in the flux calibration for the individual bolometers, and tests of the flux calibration on observations of primary and secondary calibrators. The procedure for deriving the flux calibration parameters is divided into two parts. In the first part, we use observations of astronomical sources in conjunction with the operation of the photometer internal calibration source to derive the unscaled derivatives of the flux calibration curves. To scale the calibration curves in Jy/beam/V, we then use observations of Neptune in which the beam of each bolometer is mapped using Neptune observed in a very fine scan pattern. The total instrumental uncertainties in the flux calibration for the individual bolometers is ~0.5% for most bolometers, although a few bolometers have uncertainties of ~1-5% because of issues with the Neptune observations. Based on application of the flux calibration parameters to Neptune observations performed using typical scan map observing modes, we determined that measurements from each array as a whole have instrumental uncertainties of 1.5%. This is considerably less than the absolute calibration uncertainty associated with the model of Neptune, which is estimated at 4%.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.
-
The effect of a scanning flat fold mirror on a CMB B-mode experiment
Authors:
William F. Grainger,
Chris E. North,
Peter A. R. Ade
Abstract:
We investigate the possibility of using a flat-fold beam steering mirror for a CMB B-mode experiment. An aluminium flat-fold mirror is found to add $\sim$0.075% polarization, which varies in a scan synchronous way. Time-domain simulations of a realistic scanning pattern are performed, and the effect on the power-spectrum illustrated and a possible method of correction applied.
We investigate the possibility of using a flat-fold beam steering mirror for a CMB B-mode experiment. An aluminium flat-fold mirror is found to add $\sim$0.075% polarization, which varies in a scan synchronous way. Time-domain simulations of a realistic scanning pattern are performed, and the effect on the power-spectrum illustrated and a possible method of correction applied.
△ Less
Submitted 17 May, 2011;
originally announced May 2011.
-
Impact of modulation on CMB B-mode polarization experiments
Authors:
Michael L. Brown,
Anthony Challinor,
Chris E. North,
Bradley R. Johnson,
Daniel O'Dea,
David Sutton
Abstract:
We investigate the impact of both slow and fast polarization modulation strategies on the science return of upcoming ground-based experiments aimed at measuring the B-mode polarization of the CMB. Using simulations of the Clover experiment, we compare the ability of modulated and un-modulated observations to recover the signature of gravitational waves in the polarized CMB sky in the presence of…
▽ More
We investigate the impact of both slow and fast polarization modulation strategies on the science return of upcoming ground-based experiments aimed at measuring the B-mode polarization of the CMB. Using simulations of the Clover experiment, we compare the ability of modulated and un-modulated observations to recover the signature of gravitational waves in the polarized CMB sky in the presence of a number of anticipated systematic effects. The general expectations that fast modulation is helpful in mitigating low-frequency detector noise, and that the additional redundancy in the projection of the instrument's polarization sensitivity directions onto the sky when modulating reduces the impact of instrumental polarization, are borne out by our simulations. Neither low-frequency polarized atmospheric fluctuations nor systematic errors in the polarization sensitivity directions are mitigated by modulation. Additionally, we find no significant reduction in the effect of pointing errors by modulation. For a Clover-like experiment, pointing jitter should be negligible but any systematic mis-calibration of the polarization coordinate reference system results in significant E-B mixing on all angular scales and will require careful control. We also stress the importance of combining data from multiple detectors in order to remove the effects of common-mode systematics (such as 1/f atmospheric noise) on the measured polarization signal. Finally we compare the performance of our simulated experiment with the predicted performance from a Fisher analysis. We find good agreement between the Fisher predictions and the simulations except for the very largest scales where the power spectrum estimator we have used introduces additional variance to the B-mode signal recovered from our simulations.
△ Less
Submitted 26 May, 2009; v1 submitted 24 September, 2008;
originally announced September 2008.
-
Waveguide-to-planar circuit transition for millimetre-wave detectors
Authors:
G. Yassin,
P. K. Grimes,
O. G. King,
C. E. North
Abstract:
We present a novel design of a waveguide to microstrip or coplanar waveguide transition using a unilateral finline taper. The transition from the unilateral finline mode to the TEM microstrip mode is done directly, avoiding the antipodal finline tapers that have commonly been employed. This results in significant simplification of the design and fabrication, and shortening of the chip length, th…
▽ More
We present a novel design of a waveguide to microstrip or coplanar waveguide transition using a unilateral finline taper. The transition from the unilateral finline mode to the TEM microstrip mode is done directly, avoiding the antipodal finline tapers that have commonly been employed. This results in significant simplification of the design and fabrication, and shortening of the chip length, thereby reducing insertion loss. In this paper we shall present designs at 90 GHz that can be employed in superconducting tunnel junction mixers or Transition Edge Sensor bolometers, and scale-model measurements at 15 GHz.
△ Less
Submitted 7 September, 2008; v1 submitted 2 June, 2008;
originally announced June 2008.
-
Detecting the B-mode Polarisation of the CMB with Clover
Authors:
C. E. North,
B. R. Johnson,
P. A. R. Ade,
M. D. Audley,
C. Baines,
R. A. Battye,
M. L. Brown,
P. Cabella,
P. G. Calisse,
A. D. Challinor,
W. D. Duncan,
P. G. Ferreira,
W. K. Gear,
D. Glowacka,
D. J. Goldie,
P. K. Grimes,
M. Halpern,
V. Haynes,
G. C. Hilton,
K. D. Irwin,
M. E. Jones,
A. N. Lasenby,
P. J. Leahy,
J. Leech,
B. Maffei
, et al. (19 additional authors not shown)
Abstract:
We describe the objectives, design and predicted performance of Clover, which is a ground-based experiment to measure the faint ``B-mode'' polarisation pattern in the cosmic microwave background (CMB). To achieve this goal, clover will make polarimetric observations of approximately 1000 deg^2 of the sky in spectral bands centred on 97, 150 and 225 GHz. The observations will be made with a two-m…
▽ More
We describe the objectives, design and predicted performance of Clover, which is a ground-based experiment to measure the faint ``B-mode'' polarisation pattern in the cosmic microwave background (CMB). To achieve this goal, clover will make polarimetric observations of approximately 1000 deg^2 of the sky in spectral bands centred on 97, 150 and 225 GHz. The observations will be made with a two-mirror compact range antenna fed by profiled corrugated horns. The telescope beam sizes for each band are 7.5, 5.5 and 5.5 arcmin, respectively. The polarisation of the sky will be measured with a rotating half-wave plate and stationary analyser, which will be an orthomode transducer. The sky coverage combined with the angular resolution will allow us to measure the angular power spectra between 20 < l < 1000. Each frequency band will employ 192 single polarisation, photon noise limited TES bolometers cooled to 100 mK. The background-limited sensitivity of these detector arrays will allow us to constrain the tensor-to-scalar ratio to 0.026 at 3sigma, assuming any polarised foreground signals can be subtracted with minimal degradation to the 150 GHz sensitivity. Systematic errors will be mitigated by modulating the polarisation of the sky signals with the rotating half-wave plate, fast azimuth scans and periodic telescope rotations about its boresight. The three spectral bands will be divided into two separate but nearly identical instruments - one for 97 GHz and another for 150 and 225 GHz. The two instruments will be sited on identical three-axis mounts in the Atacama Desert in Chile near Pampa la Bola. Observations are expected to begin in late 2009.
△ Less
Submitted 3 June, 2008; v1 submitted 23 May, 2008;
originally announced May 2008.