-
DarkSide-20k sensitivity to light dark matter particles
Authors:
DarkSide-20k Collaboration,
:,
F. Acerbi,
P. Adhikari,
P. Agnes,
I. Ahmad,
S. Albergo,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
P. Amaudruz,
M. Angiolilli,
E. Aprile,
R. Ardito,
M. Atzori Corona,
D. J. Auty,
M. Ave,
I. C. Avetisov,
O. Azzolini,
H. O. Back,
Z. Balmforth,
A. Barrado Olmedo,
P. Barrillon,
G. Batignani,
P. Bhowmick
, et al. (289 additional authors not shown)
Abstract:
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more arg…
▽ More
The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV/c$^2$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV/c$^2$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP--nucleon interaction cross-sections below $1\times10^{-42}$ cm$^2$ is achievable for WIMP masses above 800 MeV/c$^2$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV/c$^2$.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Development of wavelength-shifting PEN foils for next generation experiments
Authors:
M. Kuźniak,
S. Pawłowski,
A. Abramowicz,
A. F. V. Cortez,
M. Kumosiński,
T. Łęcki,
G. Nieradka
Abstract:
Polyethylene naphthalate (PEN) foils have been demonstrated as a wavelength shifter suitable for operation in liquid argon. At the same time, wavelength shifting efficiency of technical grades of PEN, commercially available on the market, is lower than that of tetraphenyl butadiene (TPB). This paper reports on an R&D program focused on exploring the intrinsic limitations of PEN and optimizing it f…
▽ More
Polyethylene naphthalate (PEN) foils have been demonstrated as a wavelength shifter suitable for operation in liquid argon. At the same time, wavelength shifting efficiency of technical grades of PEN, commercially available on the market, is lower than that of tetraphenyl butadiene (TPB). This paper reports on an R&D program focused on exploring the intrinsic limitations of PEN and optimizing it for the highest achievable wavelength shifting efficiency.
△ Less
Submitted 28 March, 2024;
originally announced March 2024.
-
Ultralight vector dark matter search using data from the KAGRA O3GK run
Authors:
The LIGO Scientific Collaboration,
the Virgo Collaboration,
the KAGRA Collaboration,
A. G. Abac,
R. Abbott,
H. Abe,
I. Abouelfettouh,
F. Acernese,
K. Ackley,
C. Adamcewicz,
S. Adhicary,
N. Adhikari,
R. X. Adhikari,
V. K. Adkins,
V. B. Adya,
C. Affeldt,
D. Agarwal,
M. Agathos,
O. D. Aguiar,
I. Aguilar,
L. Aiello,
A. Ain,
P. Ajith,
T. Akutsu,
S. Albanesi
, et al. (1778 additional authors not shown)
Abstract:
Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we prese…
▽ More
Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for $U(1)_{B-L}$ gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the $U(1)_{B-L}$ gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Search for Eccentric Black Hole Coalescences during the Third Observing Run of LIGO and Virgo
Authors:
The LIGO Scientific Collaboration,
the Virgo Collaboration,
the KAGRA Collaboration,
A. G. Abac,
R. Abbott,
H. Abe,
F. Acernese,
K. Ackley,
C. Adamcewicz,
S. Adhicary,
N. Adhikari,
R. X. Adhikari,
V. K. Adkins,
V. B. Adya,
C. Affeldt,
D. Agarwal,
M. Agathos,
O. D. Aguiar,
I. Aguilar,
L. Aiello,
A. Ain,
P. Ajith,
T. Akutsu,
S. Albanesi,
R. A. Alfaidi
, et al. (1750 additional authors not shown)
Abstract:
Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effect…
▽ More
Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass $M>70$ $M_\odot$) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities $0 < e \leq 0.3$ at $0.33$ Gpc$^{-3}$ yr$^{-1}$ at 90\% confidence level.
△ Less
Submitted 7 August, 2023;
originally announced August 2023.
-
Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network
Authors:
The LIGO Scientific Collaboration,
the Virgo Collaboration,
the KAGRA Collaboration,
R. Abbott,
H. Abe,
F. Acernese,
K. Ackley,
S. Adhicary,
N. Adhikari,
R. X. Adhikari,
V. K. Adkins,
V. B. Adya,
C. Affeldt,
D. Agarwal,
M. Agathos,
O. D. Aguiar,
L. Aiello,
A. Ain,
P. Ajith,
T. Akutsu,
S. Albanesi,
R. A. Alfaidi,
C. Alléné,
A. Allocca,
P. A. Altin
, et al. (1670 additional authors not shown)
Abstract:
Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated…
▽ More
Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects.
△ Less
Submitted 17 April, 2023;
originally announced April 2023.
-
Search for subsolar-mass black hole binaries in the second part of Advanced LIGO's and Advanced Virgo's third observing run
Authors:
The LIGO Scientific Collaboration,
the Virgo Collaboration,
the KAGRA Collaboration,
R. Abbott,
H. Abe,
F. Acernese,
K. Ackley,
S. Adhicary,
N. Adhikari,
R. X. Adhikari,
V. K. Adkins,
V. B. Adya,
C. Affeldt,
D. Agarwal,
M. Agathos,
O. D. Aguiar,
L. Aiello,
A. Ain,
P. Ajith,
T. Akutsu,
S. Albanesi,
R. A. Alfaidi,
C. Alléné,
A. Allocca,
P. A. Altin
, et al. (1680 additional authors not shown)
Abstract:
We describe a search for gravitational waves from compact binaries with at least one component with mass 0.2 $M_\odot$ -- $1.0 M_\odot$ and mass ratio $q \geq 0.1$ in Advanced LIGO and Advanced Virgo data collected between 1 November 2019, 15:00 UTC and 27 March 2020, 17:00 UTC. No signals were detected. The most significant candidate has a false alarm rate of 0.2 $\mathrm{yr}^{-1}$. We estimate t…
▽ More
We describe a search for gravitational waves from compact binaries with at least one component with mass 0.2 $M_\odot$ -- $1.0 M_\odot$ and mass ratio $q \geq 0.1$ in Advanced LIGO and Advanced Virgo data collected between 1 November 2019, 15:00 UTC and 27 March 2020, 17:00 UTC. No signals were detected. The most significant candidate has a false alarm rate of 0.2 $\mathrm{yr}^{-1}$. We estimate the sensitivity of our search over the entirety of Advanced LIGO's and Advanced Virgo's third observing run, and present the most stringent limits to date on the merger rate of binary black holes with at least one subsolar-mass component. We use the upper limits to constrain two fiducial scenarios that could produce subsolar-mass black holes: primordial black holes (PBH) and a model of dissipative dark matter. The PBH model uses recent prescriptions for the merger rate of PBH binaries that include a rate suppression factor to effectively account for PBH early binary disruptions. If the PBHs are monochromatically distributed, we can exclude a dark matter fraction in PBHs $f_\mathrm{PBH} \gtrsim 0.6$ (at 90% confidence) in the probed subsolar-mass range. However, if we allow for broad PBH mass distributions we are unable to rule out $f_\mathrm{PBH} = 1$. For the dissipative model, where the dark matter has chemistry that allows a small fraction to cool and collapse into black holes, we find an upper bound $f_{\mathrm{DBH}} < 10^{-5}$ on the fraction of atomic dark matter collapsed into black holes.
△ Less
Submitted 26 January, 2024; v1 submitted 2 December, 2022;
originally announced December 2022.
-
Model-based cross-correlation search for gravitational waves from the low-mass X-ray binary Scorpius X-1 in LIGO O3 data
Authors:
The LIGO Scientific Collaboration,
the Virgo Collaboration,
the KAGRA Collaboration,
R. Abbott,
H. Abe,
F. Acernese,
K. Ackley,
S. Adhicary,
N. Adhikari,
R. X. Adhikari,
V. K. Adkins,
V. B. Adya,
C. Affeldt,
D. Agarwal,
M. Agathos,
O. D. Aguiar,
L. Aiello,
A. Ain,
P. Ajith,
T. Akutsu,
S. Albanesi,
R. A. Alfaidi,
C. Alléné,
A. Allocca,
P. A. Altin
, et al. (1670 additional authors not shown)
Abstract:
We present the results of a model-based search for continuous gravitational waves from the low-mass X-ray binary Scorpius X-1 using LIGO detector data from the third observing run of Advanced LIGO, Advanced Virgo and KAGRA. This is a semicoherent search which uses details of the signal model to coherently combine data separated by less than a specified coherence time, which can be adjusted to bala…
▽ More
We present the results of a model-based search for continuous gravitational waves from the low-mass X-ray binary Scorpius X-1 using LIGO detector data from the third observing run of Advanced LIGO, Advanced Virgo and KAGRA. This is a semicoherent search which uses details of the signal model to coherently combine data separated by less than a specified coherence time, which can be adjusted to balance sensitivity with computing cost. The search covered a range of gravitational-wave frequencies from 25Hz to 1600Hz, as well as ranges in orbital speed, frequency and phase determined from observational constraints. No significant detection candidates were found, and upper limits were set as a function of frequency. The most stringent limits, between 100Hz and 200Hz, correspond to an amplitude h0 of about 1e-25 when marginalized isotropically over the unknown inclination angle of the neutron star's rotation axis, or less than 4e-26 assuming the optimal orientation. The sensitivity of this search is now probing amplitudes predicted by models of torque balance equilibrium. For the usual conservative model assuming accretion at the surface of the neutron star, our isotropically-marginalized upper limits are close to the predicted amplitude from about 70Hz to 100Hz; the limits assuming the neutron star spin is aligned with the most likely orbital angular momentum are below the conservative torque balance predictions from 40Hz to 200Hz. Assuming a broader range of accretion models, our direct limits on gravitational-wave amplitude delve into the relevant parameter space over a wide range of frequencies, to 500Hz or more.
△ Less
Submitted 2 January, 2023; v1 submitted 6 September, 2022;
originally announced September 2022.
-
SiPM cross-talk in liquid argon detectors
Authors:
M. G. Boulay,
V. Camillo,
N. Canci,
S. Choudhary,
L. Consiglio,
A. Flammini,
C. Galbiati,
C. Ghiano,
A. Gola,
S. Horikawa,
P. Kachru,
I. Kochanek,
K. Kondo,
G. Korga,
M. Kuźniak,
A. Mazzi,
A. Moharana,
G. Nieradka,
G. Paternoster,
A. Razeto,
D. Sablone,
T. N. Thorpe,
C. Türkoğlu,
H. Wang,
M. Rescigno
, et al. (1 additional authors not shown)
Abstract:
SiPM-based readouts are becoming the standard for light detection in particle detectors given their superior resolution and ease of use with respect to vacuum tube photo-multipliers. However, the contributions of detection noise such as the dark rate, cross-talk, and after-pulsing may impact significantly their performance. In this work, we present the development of highly reflective single-phase…
▽ More
SiPM-based readouts are becoming the standard for light detection in particle detectors given their superior resolution and ease of use with respect to vacuum tube photo-multipliers. However, the contributions of detection noise such as the dark rate, cross-talk, and after-pulsing may impact significantly their performance. In this work, we present the development of highly reflective single-phase argon chambers capable of light yields up to 32 photo-electrons per keV, with roughly 12 being primary photo-electrons generated by the argon scintillation, while the rest are accounted by optical cross-talk. Furthermore, the presence of compound processes results in a generalized Fano factor larger than 2 already at an over-voltage of 5 V. Finally, we present a parametrization of the optical cross-talk for the FBK NUV-HD-Cryo SiPMs at 87 K that can be extended to future detectors with tailored optical simulations.
△ Less
Submitted 6 July, 2022; v1 submitted 5 January, 2022;
originally announced January 2022.
-
Direct comparison of PEN and TPB wavelength shifters in a liquid argon detector
Authors:
M. G. Boulay,
V. Camillo,
N. Canci,
S. Choudhary,
L. Consiglio,
A. Flammini,
C. Galbiati,
C. Ghiano,
A. Gola,
S. Horikawa,
P. Kachru,
I. Kochanek,
K. Kondo,
G. Korga,
M. Kuźniak,
M. Kuźwa,
A. Leonhardt,
T. Łęcki,
A. Mazzi,
A. Moharana,
G. Nieradka,
G. Paternoster,
T. R. Pollmann,
A. Razeto,
D. Sablone
, et al. (4 additional authors not shown)
Abstract:
A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and a wavelength shifter is required for its efficient detection. In this work, we directly compare the light yield achieved in two identical liquid argon chambers,…
▽ More
A large number of particle detectors employ liquid argon as their target material owing to its high scintillation yield and its ability to drift ionization charge over large distances. Scintillation light from argon is peaked at 128 nm and a wavelength shifter is required for its efficient detection. In this work, we directly compare the light yield achieved in two identical liquid argon chambers, one of which is equipped with PolyEthylene Naphthalate (PEN) and the other with TetraPhenyl Butadiene (TPB) wavelength shifter. Both chambers are lined with enhanced specular reflectors and instrumented with SiPMs with a coverage fraction of approximately 1%, which represents a geometry comparable to the future large scale detectors. We measured the light yield of the PEN chamber to be 39.4$\pm$0.4(stat)$\pm$1.9(syst)% of the yield of the TPB chamber. Using a Monte Carlo simulation this result is used to extract the wavelength shifting efficiency of PEN relative to TPB equal to 47.2$\pm$5.7%. This result paves the way for the use of easily available PEN foils as a wavelength shifter, which can substantially simplify the construction of future liquid argon detectors.
△ Less
Submitted 15 March, 2022; v1 submitted 29 June, 2021;
originally announced June 2021.
-
Development of very-thick transparent GEMs with wavelength-shifting capability for noble element TPCs
Authors:
M. Kuźniak,
D. González-Díaz,
P. Amedo,
C. D. R. Azevedo,
D. J. Fernández-Posada,
M. Kuźwa,
S. Leardini,
A. Leonhardt,
T. Łęcki,
L. Manzanillas,
D. Muenstermann,
G. Nieradka,
R. de Oliveira,
T. R. Pollmann,
A. Saá Hernández,
T. Sworobowicz,
C. Türkoğlu,
S. Williams
Abstract:
A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a polyethylene naphthalate plate, a natural wavelength-shifter. Such a device has good prospects for scalability and, by virtue of its genuine optical properties, it…
▽ More
A new concept for the simultaneous detection of primary and secondary scintillation in time projection chambers is proposed. Its core element is a type of very-thick GEM structure supplied with transparent electrodes and machined from a polyethylene naphthalate plate, a natural wavelength-shifter. Such a device has good prospects for scalability and, by virtue of its genuine optical properties, it can improve on the light collection efficiency, energy threshold and resolution of conventional micropattern gas detectors. This, together with the intrinsic radiopurity of its constituting elements, offers advantages for noble gas and liquid based time projection chambers, used for dark matter searches and neutrino experiments. Production, optical and electrical characterization, and first measurements performed with the new device are reported.
△ Less
Submitted 15 March, 2022; v1 submitted 7 June, 2021;
originally announced June 2021.