-
CCAT: Comparisons of 280 GHz TiN and Al Kinetic Inductance Detector Arrays
Authors:
Cody J. Duell,
Jason Austermann,
James Beall,
James R. Burgoyne,
Scott C. Chapman,
Steve K. Choi,
Rodrigo G. Freundt,
Jiansong Gao,
Christopher Groppi,
Anthony I. Huber,
Zachary B. Huber,
Johannes Hubmayr,
Ben Keller,
Yaqiong Li,
Lawrence T. Lin,
Justin Matthewson,
Philip Mauskopf,
Alicia Middleton,
Colin C. Murphy,
Michael D. Niemack,
Thomas Nikola,
Adrian K. Sinclair,
Ema Smith,
Jeff van Lanen,
Anna Vaskuri
, et al. (5 additional authors not shown)
Abstract:
The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submilli…
▽ More
The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submillimeter wavelengths. The first of these instrument modules, the 280 GHz module, will include ${\sim}$10,000 kinetic inductance detectors (KIDs) across three arrays. While the first array was fabricated out of tri-layer TiN/Ti/TiN, the other two arrays were fabricated out of a single layer of Al. This combination of materials within the same instrument provides a unique opportunity to directly compare the performance and noise properties of two different detector materials that are seeing increasing use within the field. We present preliminary comparisons here based on lab testing, along with a discussion of the potential impacts on operation when observing and translating raw data to science-grade maps.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
Optical modeling of systematic uncertainties in detector polarization angles for the Atacama Cosmology Telescope
Authors:
Colin C. Murphy,
Steve K. Choi,
Rahul Datta,
Mark J. Devlin,
Matthew Hasselfield,
Brian J. Koopman,
Jeff McMahon,
Sigurd Naess,
Michael D. Niemack,
Lyman A. Page,
Suzanne T. Staggs,
Robert Thornton,
Edward J. Wollack
Abstract:
We present an estimate of the Atacama Cosmology Telescope (ACT) detector polarization angle systematic uncertainty from optics perturbation analysis using polarization-sensitive ray tracing in CODE V optical design software. Uncertainties in polarization angle calibration in CMB measurements can limit constraints on cosmic birefringence and other cosmological measurements. Our framework estimates…
▽ More
We present an estimate of the Atacama Cosmology Telescope (ACT) detector polarization angle systematic uncertainty from optics perturbation analysis using polarization-sensitive ray tracing in CODE V optical design software. Uncertainties in polarization angle calibration in CMB measurements can limit constraints on cosmic birefringence and other cosmological measurements. Our framework estimates the angle calibration systematic uncertainties from possible displacements in lens positions and orientations, and anti-reflection coating (ARC) thicknesses and refractive indices. With millimeter displacements in lens positions and percent-level perturbations in ARC thicknesses and indices from design, we find the total systematic uncertainty for three ACT detector arrays operating between 90--220 GHz to be at the tenth of degree scale. Reduced lens position and orientation uncertainties from physical measurements could lead to a reduction in the systematic uncertainty estimated with the framework presented here. This optical modeling can inform polarization angle systematic uncertainties for current and future microwave polarimeters, such as the CCAT Observatory, Simons Observatory, and CMB-S4.
△ Less
Submitted 1 March, 2024;
originally announced March 2024.
-
CCAT-prime: Design of the Mod-Cam receiver and 280 GHz MKID instrument module
Authors:
Eve M. Vavagiakis,
Cody J. Duell,
Jason Austermann,
James Beall,
Tanay Bhandarkar,
Scott C. Chapman,
Steve K. Choi,
Gabriele Coppi,
Simon Dicker,
Mark Devlin,
Rodrigo G. Freundt,
Jiansong Gao,
Christopher Groppi,
Terry L. Herter,
Zachary B. Huber,
Johannes Hubmayr,
Doug Johnstone,
Ben Keller,
Anna M. Kofman,
Yaqiong Li,
Philip Mauskopf,
Jeff McMahon,
Jenna Moore,
Colin C. Murphy,
Michael D. Niemack
, et al. (11 additional authors not shown)
Abstract:
Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a first-generation science instrument for FYST, will deliver over ten times greater mapping speed than current and near-term facilities for unprecedented 280-…
▽ More
Mod-Cam is a first light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a first-generation science instrument for FYST, will deliver over ten times greater mapping speed than current and near-term facilities for unprecedented 280-850 GHz broadband and spectroscopic measurements with microwave kinetic inductance detectors (MKIDs). CCAT-prime will address a suite of science goals, from Big Bang cosmology to star formation and galaxy evolution over cosmic time. Mod-Cam deployment on FYST with a 280 GHz instrument module containing MKID arrays is planned for early science observations in 2024. Mod-Cam will be used to test instrument modules for Prime-Cam, which can house up to seven instrument modules. We discuss the design and status of the 0.9 m diameter, 1.8 m long Mod-Cam receiver and 40 cm diameter 280 GHz instrument module, with cold stages at 40 K, 4 K, 1 K, and 100 mK. We also describe the instrument module's cryogenic readout designs to enable the readout of more than 10,000 MKIDs across 18 networks.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.