-
Short-Timescale Variability of the Blazar Mrk 421 from AstroSat and Simultaneous Multi-Wavelength Observations
Authors:
Ritaban Chatterjee,
Susmita Das,
Archishman Khasnovis,
Ritesh Ghosh,
Neeraj Kumari,
Sachindra Naik,
V. M. Larionov,
T. S. Grishina,
E. N. Kopatskaya,
E. G. Larionova,
A. A. Nikiforova,
D. A. Morozov,
S. S. Savchenko,
Yu. V. Troitskaya,
I. S. Troitsky,
A. A. Vasilyev
Abstract:
We study the multi-wavelength variability of the blazar Mrk 421 at minutes to days timescales using simultaneous data at $γ$-rays from Fermi, 0.7-20 keV energies from AstroSat, and optical and near-infrared (NIR) wavelengths from ground-based observatories. We compute the shortest variability timescales at all of the above wavebands and find its value to be ~1.1 ks at the hard X-ray energies and i…
▽ More
We study the multi-wavelength variability of the blazar Mrk 421 at minutes to days timescales using simultaneous data at $γ$-rays from Fermi, 0.7-20 keV energies from AstroSat, and optical and near-infrared (NIR) wavelengths from ground-based observatories. We compute the shortest variability timescales at all of the above wavebands and find its value to be ~1.1 ks at the hard X-ray energies and increasingly longer at soft X-rays, optical and NIR wavelengths as well as at the GeV energies. We estimate the value of the magnetic field to be 0.5 Gauss and the maximum Lorentz factor of the emitting electrons ~1.6 x $10^5$ assuming that synchrotron radiation cooling drives the shortest variability timescale. Blazars vary at a large range of timescales often from minutes to years. These results, as obtained here from the very short end of the range of variability timescales of blazars, are a confirmation of the leptonic scenario and in particular the synchrotron origin of the X-ray emission from Mrk 421 by relativistic electrons of Lorentz factor as high as $10^5$. This particular mode of confirmation has been possible using minutes to days timescale variability data obtained from AstroSat and simultaneous multi-wavelength observations.
△ Less
Submitted 1 February, 2021;
originally announced February 2021.
-
Cosmic Inference: Constraining Parameters With Observations and Highly Limited Number of Simulations
Authors:
Timur Takhtaganov,
Zarija Lukic,
Juliane Mueller,
Dmitriy Morozov
Abstract:
Cosmological probes pose an inverse problem where the measurement result is obtained through observations, and the objective is to infer values of model parameters which characterize the underlying physical system -- our Universe. Modern cosmological probes increasingly rely on measurements of the small-scale structure, and the only way to accurately model physical behavior on those scales, roughl…
▽ More
Cosmological probes pose an inverse problem where the measurement result is obtained through observations, and the objective is to infer values of model parameters which characterize the underlying physical system -- our Universe. Modern cosmological probes increasingly rely on measurements of the small-scale structure, and the only way to accurately model physical behavior on those scales, roughly 65 Mpc/h or smaller, is via expensive numerical simulations. In this paper, we provide a detailed description of a novel statistical framework for obtaining accurate parameter constraints by combining observations with a very limited number of cosmological simulations. The proposed framework utilizes multi-output Gaussian process emulators that are adaptively constructed using Bayesian optimization methods. We compare several approaches for constructing multi-output emulators that enable us to take possible inter-output correlations into account while maintaining the efficiency needed for inference. Using Lyman alpha forest flux power spectrum, we demonstrate that our adaptive approach requires considerably fewer --- by a factor of a few in Lyman alpha P(k) case considered here --- simulations compared to the emulation based on Latin hypercube sampling, and that the method is more robust in reconstructing parameters and their Bayesian credible intervals.
△ Less
Submitted 17 May, 2019;
originally announced May 2019.
-
Optical performance of an ultra-sensitive horn-coupled transition-edge-sensor bolometer with hemispherical backshort in the far infrared
Authors:
Michael D. Audley,
Gert de Lange,
Jian-Rong Gao,
Pourya Khosropanah,
Richard Hijmering,
Marcel Ridder,
Philip D. Mauskopf,
Dmitry Morozov,
Neil A. Trappe,
Stephen Doherty
Abstract:
The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\ aW/\sqrt Hz$) in the 30--60-$μ\rm m$ band where radiation is coupled to the detectors with a few-mode…
▽ More
The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\ aW/\sqrt Hz$) in the 30--60-$μ\rm m$ band where radiation is coupled to the detectors with a few-moded conical feedhorn and a hemispherical backshort. We show that these detectors have an optical efficiency of 60% (the ratio of the power detected by the TES bolometer to the total power propagating through the feedhorn). We find that the measured optical efficiency can be understood in terms of the modes propagating through the feedhorn with the aid of a spatial mode-filtering technique.
△ Less
Submitted 25 March, 2016;
originally announced March 2016.
-
Optical Response of Strained- and Unstrained-Silicon Cold-Electron Bolometers
Authors:
T. L. R. Brien,
P. A. R. Ade,
P. S. Barry,
C. J. Dunscombe,
D. R. Leadley,
D. V. Morozov,
M. Myronov,
E. H. C. Parker,
M. J. Prest,
M. Prunnila,
R. V. Sudiwala,
T. E. Whall,
P. D. Mauskopf
Abstract:
We describe the optical characterisation of two silicon cold-electron bolometers each consisting of a small ($32 \times 14~\mathrm{μm}$) island of degenerately doped silicon with superconducting aluminium contacts. Radiation is coupled into the silicon absorber with a twin-slot antenna designed to couple to 160-GHz radiation through a silicon lens.The first device has a highly doped silicon absorb…
▽ More
We describe the optical characterisation of two silicon cold-electron bolometers each consisting of a small ($32 \times 14~\mathrm{μm}$) island of degenerately doped silicon with superconducting aluminium contacts. Radiation is coupled into the silicon absorber with a twin-slot antenna designed to couple to 160-GHz radiation through a silicon lens.The first device has a highly doped silicon absorber, the second has a highly doped strained-silicon absorber.Using a novel method of cross-correlating the outputs from two parallel amplifiers, we measure noise-equivalent powers of $3.0 \times 10^{-16}$ and $6.6 \times 10^{-17}~\mathrm{W\,Hz^{-1/2}}$ for the control and strained device, respectively, when observing radiation from a 77-K source. In the case of the strained device, the noise-equivalent power is limited by the photon noise.
△ Less
Submitted 10 March, 2016;
originally announced March 2016.
-
A Strained Silicon Cold Electron Bolometer using Schottky Contacts
Authors:
T. L. R. Brien,
P. A. R. Ade,
P. S. Barry,
C. Dunscombe,
D. R. Leadley,
D. V. Morozov,
M. Myronov,
E. H. C. Parker,
M. Prunnila,
M. J. Prest,
R. V. Sudiwala,
T. E. Whall,
P. D. Mauskopf
Abstract:
We describe optical characterisation of a Strained Silicon Cold Electron Bolometer (CEB), operating on a $350~\mathrm{mK}$ stage, designed for absorption of millimetre-wave radiation. The silicon Cold Electron Bolometer utilises Schottky contacts between a superconductor and an n++ doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in…
▽ More
We describe optical characterisation of a Strained Silicon Cold Electron Bolometer (CEB), operating on a $350~\mathrm{mK}$ stage, designed for absorption of millimetre-wave radiation. The silicon Cold Electron Bolometer utilises Schottky contacts between a superconductor and an n++ doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to $160~\mathrm{GHz}$ and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of $50~\%$ for radiation coupled into the device by the planar antenna and an overall noise equivalent power (NEP), referred to absorbed optical power, of $1.1 \times 10^{-16}~\mathrm{\mbox{W Hz}^{-1/2}}$ when the detector is observing a $300~\mathrm{K}$ source through a $4~\mathrm{K}$ throughput limiting aperture. Even though this optical system is not optimised we measure a system noise equivalent temperature difference (NETD) of $6~\mathrm{\mbox{mK Hz}^{-1/2}}$. We measure the noise of the device using a cross-correlation of time stream data measured simultaneously with two junction field-effect transistor (JFET) amplifiers, with a base correlated noise level of $300~\mathrm{\mbox{pV Hz}^{-1/2}}$ and find that the total noise is consistent with a combination of photon noise, current shot noise and electron-phonon thermal noise.
△ Less
Submitted 31 July, 2014; v1 submitted 8 July, 2014;
originally announced July 2014.