Skip to main content

Showing 1–17 of 17 results for author: Mirel, P

  1. arXiv:2212.01370  [pdf, other

    astro-ph.IM

    Characterization of Low-noise Backshort-Under-Grid Kilopixel Transition Edge Sensor Arrays for PIPER

    Authors: Rahul Datta, Sumit Dahal, Eric R. Switzer, Regis P. Brekosky, Thomas Essinger-Hileman, Dale J. Fixsen, Christine A. Jhabvala, Alan J. Kogut, Timothy M. Miller, Paul Mirel, Edward J. Wollack

    Abstract: We present laboratory characterization of kilo-pixel, filled backshort-under-grid (BUG) transition-edge sensor (TES) arrays developed for the Primordial Inflation Polarization ExploreR (PIPER) balloon-borne instrument. PIPER is designed to map the polarization of the CMB on the largest angular scales and characterize dust foregrounds by observing a large fraction of the sky in four frequency bands… ▽ More

    Submitted 2 December, 2022; originally announced December 2022.

    Comments: 11 pages, 11 figures

  2. Superfluid Liquid Helium Control for the Primordial Inflation Polarization Explorer Balloon Payload

    Authors: A. Kogut, T. Essinger-Hileman, D. Fixsen, L. Lowe, P. Mirel, E. Switzer, E. Wollack

    Abstract: The Primordial Inflation Polarization Explorer (PIPER) is a stratospheric balloon payload to measure polarization of the cosmic microwave background. Twin telescopes mounted within an open-aperture bucket dewar couple the sky to bolometric detector arrays. We reduce detector loading and photon noise by cooling the entire optical chain to 1.7 K or colder. A set of fountain-effect pumps sprays super… ▽ More

    Submitted 18 May, 2021; originally announced May 2021.

    Comments: 23 pages including 14 figures, accepted for publication in Review of Scientific Instruments

  3. The Balloon-Borne Cryogenic Telescope Testbed Mission: Bulk Cryogen Transfer at 40 km Altitude

    Authors: A. Kogut, S. Denker, N. Bellis, T. Essinger-Hileman, L. Lowe, P. Mirel

    Abstract: The Balloon-Borne Cryogenic Telescope Testbed (BOBCAT) is a stratospheric balloon payload to develop technology for a future cryogenic suborbital observatory. A series of flights are intended to establish ultra-light dewar performance and open-aperture observing techniques for large (3--5 meter diameter) cryogenic telescopes at infrared wavelengths. An initial flight in 2019 demonstrated bulk tran… ▽ More

    Submitted 22 March, 2021; originally announced March 2021.

    Comments: 17 pages including 10 figures

    Journal ref: Review of Scientific Instruments, 2021, Volume 91, Issue 12, article id.124501

  4. arXiv:2103.07936  [pdf, other

    astro-ph.IM physics.ins-det

    Anti-reflection Coated Vacuum Window for the Primordial Inflation Polarization ExploreR (PIPER) balloon-borne instrument

    Authors: Rahul Datta, David T. Chuss, Joseph Eimer, Thomas Essinger-Hileman, Natalie N. Gandilo, Kyle Helson, Alan J. Kogut, Luke Lowe, Paul Mirel, Karwan Rostem, Marco Sagliocca, Danielle Sponseller, Eric R. Switzer, Peter A. Taraschi, Edward J. Wollack

    Abstract: Measuring the faint polarization signal of the cosmic microwave background (CMB) not only requires high optical throughput and instrument sensitivity but also control over systematic effects. Polarimetric cameras or receivers used in this setting often employ dielectric vacuum windows, filters, or lenses to appropriately prepare light for detection by cooled sensor arrays. These elements in the op… ▽ More

    Submitted 14 March, 2021; originally announced March 2021.

    Journal ref: Review of Scientific Instruments 92, 035111 (2021)

  5. Sub-Kelvin cooling for two kilopixel bolometer arrays in the PIPER receiver

    Authors: E. R. Switzer, P. A. R. Ade, T. Baildon, D. Benford, C. L. Bennett, D. T. Chuss, R. Datta, J. R. Eimer, D. J. Fixsen, N. N. Gandilo, T. M. Essinger-Hileman, M. Halpern, G. Hilton, K. Irwin, C. Jhabvala, M. Kimball, A. Kogut, J. Lazear, L. N. Lowe, J. J. McMahon, T. M. Miller, P. Mirel, S. H. Moseley, S. Pawlyk, S. Rodriguez , et al. (8 additional authors not shown)

    Abstract: The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne telescope mission to search for inflationary gravitational waves from the early universe. PIPER employs two 32x40 arrays of superconducting transition-edge sensors, which operate at 100 mK. An open bucket dewar of liquid helium maintains the receiver and telescope optics at 1.7 K. We describe the thermal design of the receiv… ▽ More

    Submitted 13 September, 2019; originally announced September 2019.

    Comments: 14 pages, 12 figures

    Journal ref: Rev. Sci. Inst 90(9) 2019

  6. The Primordial Inflation Polarization Explorer (PIPER)

    Authors: Natalie N. Gandilo, Peter A. R. Ade, Dominic Benford, Charles L. Bennett, David T. Chuss, Jessie L. Dotson, Joseph R. Eimer, Dale J. Fixsen, Mark Halpern, Gene Hilton, Gary F. Hinshaw, Kent Irwin, Christine Jhabvala, Mark Kimball, Alan Kogut, Luke Lowe, Jeff J. McMahon, Timothy M. Miller, Paul Mirel, S. Harvey Moseley, Samuel Pawlyk, Samelys Rodriguez, Elmer Sharp III, Peter Shirron, Johannes G. Staguhn , et al. (5 additional authors not shown)

    Abstract: The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne telescope designed to measure the polarization of the Cosmic Microwave Background on large angular scales. PIPER will map 85% of the sky at 200, 270, 350, and 600 GHz over a series of 8 conventional balloon flights from the northern and southern hemispheres. The first science flight will use two 32x40 arrays of backshort-und… ▽ More

    Submitted 20 July, 2016; originally announced July 2016.

    Comments: 8 pages, 6 figures. To be published in Proceedings of SPIE Volume 9914. Presented at SPIE Astronomical Telescopes + Instrumentation 2016, conference 9914

  7. The Primordial Inflation Polarization Explorer (PIPER)

    Authors: Justin Lazear, Peter A. R. Ade, Dominic Benford, Charles L. Bennett, David T. Chuss, Jessie L. Dotson, Joseph R. Eimer, Dale J. Fixsen, Mark Halpern, Gene Hilton, James Hinderks, Gary F. Hinshaw, Kent Irwin, Christine Jhabvala, Bradley Johnson, Alan Kogut, Luke Lowe, Jeff J. McMahon, Timothy M. Miller, Paul Mirel, S. Harvey Moseley, Samelys Rodriguez, Elmer Sharp, Johannes G. Staguhn, Eric R. Switzer , et al. (3 additional authors not shown)

    Abstract: The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne cosmic microwave background (CMB) polarimeter designed to search for evidence of inflation by measuring the large-angular scale CMB polarization signal. BICEP2 recently reported a detection of B-mode power corresponding to the tensor-to-scalar ratio r = 0.2 on ~2 degree scales. If the BICEP2 signal is caused by inflationary… ▽ More

    Submitted 9 July, 2014; originally announced July 2014.

    Comments: 11 pages, 7 figures. To be published in Proceedings of SPIE Volume 9153. Presented at SPIE Astronomical Telescopes + Instrumentation 2014, conference 9153

  8. Variable-delay Polarization Modulators for Cryogenic Millimeter-wave Applications

    Authors: David T. Chuss, Joseph R. Eimer, Dale J. Fixsen, James Hinderks, Alan J. Kogut, Justin Lazear, Paul Mirel, Eric Switzer, George M. Voellmer, Edward J. Wollack

    Abstract: We describe the design, construction, and initial validation of the variable-delay polarization modulator (VPM) designed for the PIPER cosmic microwave background polarimeter. The VPM modulates between linear and circular polarization by introducing a variable phase delay between orthogonal linear polarizations. Each VPM has a diameter of 39 cm and is engineered to operate in a cryogenic environme… ▽ More

    Submitted 28 May, 2014; v1 submitted 6 March, 2014; originally announced March 2014.

    Comments: 8 pages, 10 Figures, Submitted to Review of Scientific Instruments

  9. ARCADE 2 Observations of Galactic Radio Emission

    Authors: A. Kogut, D. J. Fixsen, S. M. Levin, M. Limon, P. M. Lubin, P. Mirel, M. Seiffert, J. Singal, T. Villela, E. Wollack, C. A. Wuensche

    Abstract: We use absolutely calibrated data from the ARCADE 2 flight in July 2006 to model Galactic emission at frequencies 3, 8, and 10 GHz. The spatial structure in the data is consistent with a superposition of free-free and synchrotron emission. Emission with spatial morphology traced by the Haslam 408 MHz survey has spectral index beta_synch = -2.5 +/- 0.1, with free-free emission contributing 0.10 +… ▽ More

    Submitted 5 January, 2009; originally announced January 2009.

    Comments: 10 poges, 9 figures. Submitted to The Astrophysical Journal

    Journal ref: Astrophys.J.734:4,2011

  10. arXiv:0901.0559  [pdf, ps, other

    astro-ph.CO

    Interpretation of the Extragalactic Radio Background

    Authors: M. Seiffert, D. J. Fixsen, A. Kogut, S. M. Levin, M. Limon, P. M. Lubin, P. Mirel, J. Singal, T. Villela, E. Wollack, C. A. Wuensche

    Abstract: We use absolutely calibrated data between 3 and 90 GHz from the 2006 balloon flight of the ARCADE 2 instrument, along with previous measurements at other frequencies, to constrain models of extragalactic emission. Such emission is a combination of the Cosmic Microwave Background (CMB) monopole, Galactic foreground emission, the integrated contribution of radio emission from external galaxies, an… ▽ More

    Submitted 5 January, 2009; originally announced January 2009.

    Comments: 8 pages, 4 figures

  11. ARCADE 2 Measurement of the Extra-Galactic Sky Temperature at 3-90 GHz

    Authors: D. J. Fixsen, A. Kogut, S. Levin, M. Limon, P. Lubin, P. Mirel, M. Seiffert, J. Singal, E. Wollack, T. Villela, C. A. Wuensche

    Abstract: The ARCADE 2 instrument has measured the absolute temperature of the sky at frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic instrument observing at balloon altitudes with no emissive windows between the beam-forming optics and the sky. An external blackbody calibrator provides an {\it in situ} reference. Systematic errors were greatly reduced by using differential radiomet… ▽ More

    Submitted 5 January, 2009; originally announced January 2009.

    Comments: 11 pages 5 figures Submitted to ApJ

  12. The ARCADE 2 Instrument

    Authors: J. Singal, D. J. Fixsen, A. Kogut, S. Levin, M. Limon, P. Lubin, P. Mirel, M. Seiffert, T. Villela, E. Wollack, C. A. Wuensche

    Abstract: The second generation Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE 2) instrument is a balloon-borne experiment to measure the radiometric temperature of the cosmic microwave background and Galactic and extra-Galactic emission at six frequencies from 3 to 90 GHz. ARCADE 2 utilizes a double-nulled design where emission from the sky is compared to that from an extern… ▽ More

    Submitted 2 April, 2010; v1 submitted 5 January, 2009; originally announced January 2009.

    Comments: 12 pages, 14 figues, 3 tables, 2 figures added, Accepted to ApJ

    Journal ref: Astrophys.J.730:138,2011

  13. ARCADE: Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission

    Authors: A. Kogut, D. Fixsen, S. Fixsen, S. Levin, M. Limon, L. Lowe, P. Mirel, M. Seiffert, J. Singal, P. Lubin, E. Wollack

    Abstract: The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument designed to measure the temperature of the cosmic microwave background at centimeter wavelengths. ARCADE searches for deviations from a blackbody spectrum resulting from energy releases in the early universe. Long-wavelength distortions in the CMB spectrum are expected in all viable c… ▽ More

    Submitted 13 September, 2006; originally announced September 2006.

    Comments: 12 pages, 6 figures. Proceedings of the Fundamental Physics With CMB workshop, UC Irvine, March 23-25, 2006, to be published in New Astronomy Reviews

    Journal ref: New Astron.Rev. 50 (2006) 925-931

  14. Design and Calibration of a Cryogenic Blackbody Calibrator at Centimeter Wavelengths

    Authors: A. Kogut, E. Wollack, D. J. Fixsen, M. Limon, P. Mirel, S. Levin, M. Seiffert, P. M. Lubin

    Abstract: We describe the design and calibration of an external cryogenic blackbody calibrator used for the first two flights of the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) instrument. The calibrator consists of a microwave absorber weakly coupled to a superfluid liquid helium bath. Half-wave corrugations viewed 30 deg off axis reduce the return loss below -35 dB. Ru… ▽ More

    Submitted 24 February, 2004; originally announced February 2004.

    Comments: 5 pages including 5 figures. Submitted to Review of Scientific Instruments

    Journal ref: Rev.Sci.Instrum. 75 (2004) 5079-5083

  15. The Temperature of the CMB at 10 GHz

    Authors: D. J. Fixsen, A. Kogut, S. Levin, M. Limon, P. Lubin, P. Mirel, M. Seiffert, E. Wollack

    Abstract: We report the results of an effort to measure the low frequency portion of the spectrum of the Cosmic Microwave Background Radiation (CMB), using a balloon-borne instrument called ARCADE (Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission). These measurements are to search for deviations from a thermal spectrum that are expected to exist in the CMB due to various processes in… ▽ More

    Submitted 24 February, 2004; originally announced February 2004.

    Comments: 8 pages including 5 figures. Submitted to The Astrophysical Journal

    Journal ref: Astrophys.J. 612 (2004) 86-95

  16. An Instrument to Measure the Temperature of the Cosmic Microwave Background Radiation at Centimeter Wavelengths

    Authors: A. Kogut, D. J. Fixsen, S. Levin, M. Limon, P. M. Lubin, P. Mirel, M. Seiffert, E. Wollack

    Abstract: The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument to measure the temperature of the cosmic microwave background at centimeter wavelengths. ARCADE uses narrow-band cryogenic radiometers to compare the sky to an external full-aperture calibrator. To minimize potential sources of systematic error, ARCADE uses a novel open-aperture desig… ▽ More

    Submitted 24 February, 2004; originally announced February 2004.

    Comments: 6 pages including 5 figures. Submitted to The Astrophysical Journal

  17. A Low Noise Thermometer Readout for Ruthenium Oxide Resistors

    Authors: D. J. Fixsen, P. G. A. Mirel, A. Kogut, M. Seiffert

    Abstract: The thermometer and thermal control system, for the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) experiment, is described, including the design, testing, and results from the first flight of ARCADE. The noise is equivalent to about 1 Omega or 0.15 mK in a second for the RuO_2 resistive thermometers at 2.7 K. The average power dissipation in each thermometer is 1… ▽ More

    Submitted 30 August, 2002; originally announced August 2002.

    Comments: 5 pages text 7 figures

    Journal ref: Rev.Sci.Instrum. 73 (2002) 3659-3663