-
Plasma-Based Etching Approach for GEM Detector Microfabrication at FBK for X-ray polarimetry in space
Authors:
A. Lega,
D. Novel,
T. Facchinelli,
C. Sgro',
L. Baldini,
M. Minuti,
M. Boscardin,
G. Pepponi,
R. Iuppa,
R. Hall-Wilton,
L. Latronico
Abstract:
Gas Electron Multiplier (GEM) detectors are crucial for enabling high-resolution X-ray polarisation of astrophysical sources when coupled to custom pixel readout ASIC in Gas Pixel Detectors (GPD), as in the Imaging X-ray Polarimetry Explorer (IXPE), the Polarlight cubesat pathfinder and the PFA telescope onboard the future large enhanced X-ray Timing and Polarimetry (eXTP) Chinese mission. The R&D…
▽ More
Gas Electron Multiplier (GEM) detectors are crucial for enabling high-resolution X-ray polarisation of astrophysical sources when coupled to custom pixel readout ASIC in Gas Pixel Detectors (GPD), as in the Imaging X-ray Polarimetry Explorer (IXPE), the Polarlight cubesat pathfinder and the PFA telescope onboard the future large enhanced X-ray Timing and Polarimetry (eXTP) Chinese mission. The R&D efforts of the IXPE collaboration have resulted in mature GPD technology. However, limitations in the classical wet-etch or laser-drilled fabrication process of GEMs motivated our exploration of alternative methods. This work focuses on investigating a plasma-based etching approach for fabricating GEM patterns at Fondazione Bruno Kessler (FBK). The objective is to improve the aspect ratio of the GEM holes, to mitigate the charging of the GEM dielectric which generates rate-dependent gain changes. Unlike the traditional wet-etch process, Reactive Ion Etching (RIE) enables more vertical etching profiles and thus better aspect ratios. Moreover, the RIE process promises to overcome non-uniformities in the GEM hole patterns which are believed to cause systemic effects in the azimuthal response of GPDs equipped with either laser-drilled or wet-etch GEMs. We present a GEM geometry with 20 micrometers in diameter and 50 micrometers pitch, accompanied by extensive characterisation (SEM and PFIB) of the structural features and aspect ratios. The collaboration with INFN Pisa and Turin enabled us to compare the electrical properties of these detectors and test their performance in their use as electron multipliers in GPDs. Although this R&D work is in its initial stages, it holds promise for enhancing the sensitivity of the IXPE mission in X-ray polarimetry measurements through GEM pattern with more vertical hole profiles.
△ Less
Submitted 13 February, 2024; v1 submitted 12 December, 2023;
originally announced December 2023.
-
Polarization properties of X-ray tubes used for Imaging X-ray Polarimetry Explorer calibration
Authors:
Ajay Ratheesh,
John Rankin,
Enrico Costa,
Ettore Del Monte,
Alessandro Di Marco,
Sergio Fabiani,
Fabio La Monaca,
Fabio Muleri,
Alda Rubini,
Paolo Soffitta,
Luca Baldini,
Massimo Minuti,
Michele Pinchera,
Carmelo Sgrò
Abstract:
In this work, we measured the polarization properties of the X-rays emitted from the X-ray tubes, which were used during the calibration of the instrument onboard Imaging X-ray Polarimetry Explorer (IXPE). X-ray tubes are used as a source of unpolarized X-rays to calibrate the response of the gas pixel detectors to unpolarized radiation. However, even though the characteristic fluorescent emission…
▽ More
In this work, we measured the polarization properties of the X-rays emitted from the X-ray tubes, which were used during the calibration of the instrument onboard Imaging X-ray Polarimetry Explorer (IXPE). X-ray tubes are used as a source of unpolarized X-rays to calibrate the response of the gas pixel detectors to unpolarized radiation. However, even though the characteristic fluorescent emission lines are unpolarized, continuum bremsstrahlung emission can be polarized based on the geometry of the accelerated electrons and emitted photons. Hence, characterizing the contribution of polarized X-rays from bremsstrahlung emission is of interest, also for future measurements. We find that when accelerated electrons are parallel to the emitted photons, the bremsstrahlung emission is unpolarized, and when they are perpendicular, the polarization increases with energy, as expected from the theoretical predictions. A comparison with the theoretical predictions is also shown.
△ Less
Submitted 27 July, 2023;
originally announced July 2023.
-
X-ray Polarimetry of the accreting pulsar 1A~0535+262 in the supercritical state with PolarLight
Authors:
Xiangyun Long,
Hua Feng,
Hong Li,
Ling-Da Kong,
Jeremy Heyl,
Long Ji,
Lian Tao,
Fabio Muleri,
Qiong Wu,
Jiahuan Zhu,
Jiahui Huang,
Massimo Minuti,
Weichun Jiang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgrò,
Gloria Spandre
, et al. (3 additional authors not shown)
Abstract:
The X-ray pulsar 1A 0535+262 exhibited a giant outburst in 2020, offering us a unique opportunity for X-ray polarimetry of an accreting pulsar in the supercritical state. Measurement with PolarLight yielded a non-detection in 3-8 keV; the 99% upper limit of the polarization fraction (PF) is found to be 0.34 averaged over spin phases, or 0.51 based on the rotating vector model. No useful constraint…
▽ More
The X-ray pulsar 1A 0535+262 exhibited a giant outburst in 2020, offering us a unique opportunity for X-ray polarimetry of an accreting pulsar in the supercritical state. Measurement with PolarLight yielded a non-detection in 3-8 keV; the 99% upper limit of the polarization fraction (PF) is found to be 0.34 averaged over spin phases, or 0.51 based on the rotating vector model. No useful constraint can be placed with phase resolved polarimetry. These upper limits are lower than a previous theoretical prediction of 0.6-0.8, but consistent with those found in other accreting pulsars, like Her X-1, Cen X-3, 4U 1626-67, and GRO J1008-57, which were in the subcritical state, or at least not confidently in the supercritical state, during the polarization measurements. Our results suggest that the relatively low PF seen in accreting pulsars cannot be attributed to the source not being in the supercritical state, but could be a general feature.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
XPOL-III: a New-Generation VLSI CMOS ASIC for High-Throughput X-ray Polarimetry
Authors:
M. Minuti,
L. Baldini,
R. Bellazzini,
A. Brez,
M. Ceccanti,
F. Krummenacher,
L. Latronico,
L. Lucchesi,
A. Manfreda,
L. Orsini,
M. Pinchera,
A. Profeti,
C. Sgr`o,
G. Spandre
Abstract:
While the successful launch and operation in space of the Gas Pixel Detectors onboard the PolarLight cubesat and the Imaging X-ray Polarimetry Explorer demonstrate the viability and the technical soundness of this class of detectors for astronomical X-ray polarimetry, it is clear that the current state of the art is not ready to meet the challenges of the next generation of experiments, such as th…
▽ More
While the successful launch and operation in space of the Gas Pixel Detectors onboard the PolarLight cubesat and the Imaging X-ray Polarimetry Explorer demonstrate the viability and the technical soundness of this class of detectors for astronomical X-ray polarimetry, it is clear that the current state of the art is not ready to meet the challenges of the next generation of experiments, such as the enhanced X-ray Timing and Polarimetry mission, designed to allow for a significantly larger data throughput.
In this paper we describe the design and test of a new custom, self-triggering readout ASIC, dubbed XPOL-III, specifically conceived to address and overcome these limitations. While building upon the overall architecture of the previous generations, the new chip improves over its predecessors in several, different key areas: the sensitivity of the trigger electronics, the flexibility in the definition of the readout window, as well as the maximum speed for the serial event readout. These design improvements, when combined, allow for almost an order of magnitude smaller dead time per event with no measurable degradation of the polarimetric, spectral, imaging or timing capability of the detector, providing a good match for the next generation of X-ray missions.
△ Less
Submitted 19 October, 2022; v1 submitted 30 August, 2022;
originally announced August 2022.
-
Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation
Authors:
Alessandro Di Marco,
Sergio Fabiani,
Fabio La Monaca,
Fabio Muleri,
John Rankin,
Paolo Soffitta,
Fei Xie,
Fabrizio Amici,
Primo attinà,
Matteo Bachetti,
Luca Baldini,
Mattia Barbanera,
Wayne Baumgartner,
Ronaldo Bellazzini,
Fabio Borotto,
Alessandro Brez,
Daniele Brienza,
Ciro Caporale,
Claudia Cardelli,
Rita Carpentiero,
Simone Castellano,
Marco Castronuovo,
Luca Cavalli,
Elisabetta Cavazzuti,
Marco Ceccanti
, et al. (58 additional authors not shown)
Abstract:
IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by…
▽ More
IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.
△ Less
Submitted 15 June, 2022;
originally announced June 2022.
-
A significant detection of X-ray Polarization in Sco X-1 with PolarLight and constraints on the corona geometry
Authors:
Xiangyun Long,
Hua Feng,
Hong Li,
Jiahuan Zhu,
Qiong Wu,
Jiahui Huang,
Massimo Minuti,
Weichun Jiang,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Jiachen Jiang,
Enrico Costa,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri
, et al. (1 additional authors not shown)
Abstract:
We report the detection of X-ray polarization in the neutron star low mass X-ray binary Scorpius (Sco) X-1 with PolarLight. The result is energy dependent, with a non-detection in 3-4 keV but a 4$σ$ detection in 4-8 keV; it is also flux dependent in the 4-8 keV band, with a non-detection when the source displays low fluxes but a 5$σ$ detection during high fluxes, in which case we obtain a polariza…
▽ More
We report the detection of X-ray polarization in the neutron star low mass X-ray binary Scorpius (Sco) X-1 with PolarLight. The result is energy dependent, with a non-detection in 3-4 keV but a 4$σ$ detection in 4-8 keV; it is also flux dependent in the 4-8 keV band, with a non-detection when the source displays low fluxes but a 5$σ$ detection during high fluxes, in which case we obtain a polarization fraction of $0.043 \pm 0.008$ and a polarization angle of $52.6^\circ \pm 5.4^\circ$. This confirms a previous marginal detection with OSO-8 in the 1970s, and marks Sco X-1 the second astrophysical source with a significant polarization measurement in the keV band. The measured polarization angle is in line with the jet orientation of the source on the sky plane ($54^\circ$), which is supposedly the symmetric axis of the system. Combining previous spectral analysis, our measurements suggest that an optically thin corona is located in the transition layer under the highest accretion rates, and disfavor the extended accretion disk corona model.
△ Less
Submitted 6 December, 2021;
originally announced December 2021.
-
The Imaging X-Ray Polarimetry Explorer (IXPE): Pre-Launch
Authors:
Martin C. Weisskopf,
Paolo Soffitta,
Luca Baldini,
Brian D. Ramsey,
Stephen L. O'Dell,
Roger W. Romani,
Giorgio Matt,
William D. Deininger,
Wayne H. Baumgartner,
Ronaldo Bellazzini,
Enrico Costa,
Jeffery J. Kolodziejczak,
Luca Latronico,
Herman L. Marshall,
Fabio Muleri,
Stephen D. Bongiorno,
Allyn Tennant,
Niccolo Bucciantini,
Michal Dovciak,
Frederic Marin,
Alan Marscher,
Juri Poutanen,
Pat Slane,
Roberto Turolla,
William Kalinowski
, et al. (133 additional authors not shown)
Abstract:
Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the…
▽ More
Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the focus. A coilable boom, deployed on orbit, provides the necessary 4-m focal length. The observatory utilizes a 3-axis-stabilized spacecraft which provides services such as power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of X-ray sources, with follow-on observations of selected targets.
△ Less
Submitted 21 December, 2021; v1 submitted 2 December, 2021;
originally announced December 2021.
-
The Instrument of the Imaging X-ray Polarimetry Explorer
Authors:
Paolo Soffitta,
Luca Baldini,
Ronaldo Bellazzini,
Enrico Costa,
Luca Latronico,
Fabio Muleri,
Ettore Del Monte,
Sergio Fabiani,
Massimo Minuti,
Michele Pinchera,
Carmelo Sgrò,
Gloria Spandre,
Alessio Trois,
Fabrizio Amici,
Hans Andersson,
Primo Attinà,
Matteo Bachetti,
Mattia Barbanera,
Fabio Borotto,
Alessandro Brez,
Daniele Brienza,
Ciro Caporale,
Claudia Cardelli,
Rita Carpentiero,
Simone Castellano
, et al. (56 additional authors not shown)
Abstract:
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detecto…
▽ More
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, in part due to the fate of approved missions and in part because the celestial X-ray sources appeared less polarized than expected. Only one positive measurement has been available until now. Indeed the eight Orbiting Solar Observatory measured the polarization of the Crab nebula in the 70s.
The advent of techniques of microelectronics allowed for designing a detector based on the photoelectric effect in gas in an energy range where the optics are efficient in focusing X-rays. Herewe describe the Instrument, which is the major contribution of the Italian collaboration to the SmallExplorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will be flown in late 2021. The instrument, is composed of three Detector Units, based on this technique, and a Detector Service Unit. Three Mirror Modules provided by Marshall Space Flight Center focus X-rays onto the detectors. In the following we will show the technological choices, their scientific motivation and the results from the calibration of the Instrument.
IXPE will perform imaging, timing and energy resolved polarimetry in the 2-8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.
△ Less
Submitted 31 July, 2021;
originally announced August 2021.
-
Design, Construction, and Test of the Gas Pixel Detectors for the IXPE Mission
Authors:
L. Baldini,
M. Barbanera,
R. Bellazzini,
R. Bonino,
F. Borotto,
A. Brez,
C. Caporale,
C. Cardelli,
S. Castellano,
M. Ceccanti,
S. Citraro,
N. Di Lalla,
L. Latronico,
L. Lucchesi,
C. Magazzù,
G. Magazzù,
S. Maldera,
A. Manfreda,
M. Marengo,
A. Marrocchesi,
P. Mereu,
M. Minuti,
F. Mosti,
H. Nasimi,
A. Nuti
, et al. (69 additional authors not shown)
Abstract:
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collectin…
▽ More
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis -- particularly as far as the response to unpolarized radiation and the stability in time are concerned.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Fermi Large Area Telescope Performance After 10 Years Of Operation
Authors:
The Fermi LAT Collaboration,
M. Ajello,
W. B. Atwood,
M. Axelsson,
R. Bagagli,
M. Bagni,
L. Baldini,
D. Bastieri,
F. Bellardi,
R. Bellazzini,
E. Bissaldi,
E. D. Bloom,
R. Bonino,
J. Bregeon,
A. Brez,
P. Bruel,
R. Buehler,
S. Buson,
R. A. Cameron,
P. A. Caraveo,
E. Cavazzuti,
M. Ceccanti,
S. Chen,
C. C. Cheung,
S. Ciprini
, et al. (104 additional authors not shown)
Abstract:
The Large Area Telescope (LAT), the primary instrument for the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy gamma-ray telescope, covering the energy range from 30 MeV to more than 300 GeV. We describe the performance of the instrument at the 10-year milestone. LAT performance remains well within the specifications defined during the planning phase…
▽ More
The Large Area Telescope (LAT), the primary instrument for the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view, high-energy gamma-ray telescope, covering the energy range from 30 MeV to more than 300 GeV. We describe the performance of the instrument at the 10-year milestone. LAT performance remains well within the specifications defined during the planning phase, validating the design choices and supporting the compelling case to extend the duration of the Fermi mission. The details provided here will be useful when designing the next generation of high-energy gamma-ray observatories.
△ Less
Submitted 6 September, 2021; v1 submitted 23 June, 2021;
originally announced June 2021.
-
X-ray polarimetry of the Crab nebula with PolarLight: polarization recovery after the glitch and a secular position angle variation
Authors:
Xiangyun Long,
Hua Feng,
Hong Li,
Jiahuan Zhu,
Qiong Wu,
Jiahui Huang,
Massimo Minuti,
Weichun Jiang,
Weihua Wang,
Renxin Xu,
Enrico Costa,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera
, et al. (2 additional authors not shown)
Abstract:
We report follow-up observations of the Crab nebula with the PolarLight X-ray polarimeter, which revealed a possible variation in polarization associated with a pulsar glitch in 2019. The new observations confirm that the polarization has recovered roughly 100 days after the glitch. With the new observations, we find that the polarization angle (PA) measured with PolarLight from the total nebular…
▽ More
We report follow-up observations of the Crab nebula with the PolarLight X-ray polarimeter, which revealed a possible variation in polarization associated with a pulsar glitch in 2019. The new observations confirm that the polarization has recovered roughly 100 days after the glitch. With the new observations, we find that the polarization angle (PA) measured with PolarLight from the total nebular emission has a difference of 18.0 +- 4.6 (deg) from that measured 42 years ago with OSO-8, indicating a secular evolution of polarization with either the Crab nebula or pulsar. The long-term variation in PA could be a result of multiple glitches in the history, magnetic reconnection or movement of synchrotron emitting structures in the nebula, or secular evolution of the pulsar magnetic geometry.
△ Less
Submitted 22 April, 2021;
originally announced April 2021.
-
Discrimination of background events in the PolarLight X-ray polarimeter
Authors:
Jiahuan Zhu,
Hong Li,
Hua Feng,
Jiahui Huang,
Xiangyun Long,
Qiong Wu,
Weichun Jiang,
Massimo Minuti,
Saverio Citraro,
Hikmat Nasimi,
Dongxin Yang,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri,
Paolo Soffitta,
Enrico Costa
Abstract:
PolarLight is a space-borne X-ray polarimeter that measures the X-ray polarization via electron tracking in an ionization chamber. It is a collimated instrument and thus suffers from the background on the whole detector plane. The majority of background events are induced by high energy charged particles and show ionization morphologies distinct from those produced by X-rays of interest. Comparing…
▽ More
PolarLight is a space-borne X-ray polarimeter that measures the X-ray polarization via electron tracking in an ionization chamber. It is a collimated instrument and thus suffers from the background on the whole detector plane. The majority of background events are induced by high energy charged particles and show ionization morphologies distinct from those produced by X-rays of interest. Comparing on-source and off-source observations, we find that the two datasets display different distributions on image properties. The boundaries between the source and background distributions are obtained and can be used for background discrimination. Such a means can remove over 70% of the background events measured with PolarLight. This approaches the theoretical upper limit of the background fraction that is removable and justifies its effectiveness. For observations with the Crab nebula, the background contamination decreases from 25% to 8% after discrimination, indicative of a polarimetric sensitivity of around 0.2 Crab for PolarLight. This work also provides insights into future X-ray polarimetric telescopes.
△ Less
Submitted 13 May, 2021; v1 submitted 23 March, 2021;
originally announced March 2021.
-
Modeling the in-orbit background of PolarLight
Authors:
Jiahui Huang,
Hua Feng,
Hong Li,
Xiangyun Long,
Dongxin Yang,
Weihe Zeng,
Qiong Wu,
Weichun Jiang,
Massimo Minuti,
Enrico Costa,
Fabio Muleri,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Zhi Zeng,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera
, et al. (1 additional authors not shown)
Abstract:
PolarLight is a gas pixel X-ray polarimeter mounted on a CubeSat, which was launched into a Sun-synchronous orbit in October 2018. We build a mass model of the whole CubeSat with the Geant4 toolkit to simulate the background induced by the cosmic X-ray background (CXB) and high energy charged particles in the orbit. The simulated energy spectra and morphologies of event images both suggest that th…
▽ More
PolarLight is a gas pixel X-ray polarimeter mounted on a CubeSat, which was launched into a Sun-synchronous orbit in October 2018. We build a mass model of the whole CubeSat with the Geant4 toolkit to simulate the background induced by the cosmic X-ray background (CXB) and high energy charged particles in the orbit. The simulated energy spectra and morphologies of event images both suggest that the measured background with PolarLight is dominated by high energy electrons, with a minor contribution from protons and the CXB. The simulation reveals that, in the energy range of 2-8 keV, there are roughly 28% of the background events are caused by energy deposit from a secondary electron with an energy of a few keV, in a physical process identical to the detection of X-rays. Thus, this fraction of background cannot be discriminated from X-ray events. The background distribution is uneven on the detector plane, with an enhancement near the edges. The edge effect is because high energy electrons tend to produce long tracks, which are discarded by the readout electronics unless they have partial energy deposits near the edges. The internal background rate is expected to be around 6 x 10^-3 counts/s/cm2 in 2-8 keV if an effective particle discrimination algorithm can be applied. This indicates that the internal background should be negligible for future focusing X-ray polarimeters with a focal size in the order of mm.
△ Less
Submitted 17 January, 2021;
originally announced January 2021.
-
Re-detection and a Possible Time Variation of Soft X-ray Polarisation from the Crab
Authors:
Hua Feng,
Hong Li,
Xiangyun Long,
Ronaldo Bellazzini,
Enrico Costa,
Qiong Wu,
Jiahui Huang,
Weichun Jiang,
Massimo Minuti,
Weihua Wang,
Renxin Xu,
Dongxin Yang,
Luca Baldini,
Saverio Citraro,
Hikmat Nasimi,
Paolo Soffitta,
Fabio Muleri,
Aera Jung,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro
, et al. (2 additional authors not shown)
Abstract:
The Crab nebula is so far the only celestial object with a statistically significant detection in soft x-ray polarimetry, a window that has not been explored in astronomy since the 1970s. However, soft x-ray polarimetry is expected to be a sensitive probe of magnetic fields in high energy astrophysical objects including rotation-powered pulsars and pulsar wind nebulae. Here we report the re-detect…
▽ More
The Crab nebula is so far the only celestial object with a statistically significant detection in soft x-ray polarimetry, a window that has not been explored in astronomy since the 1970s. However, soft x-ray polarimetry is expected to be a sensitive probe of magnetic fields in high energy astrophysical objects including rotation-powered pulsars and pulsar wind nebulae. Here we report the re-detection of soft x-ray polarisation after 40 years from the Crab nebula and pulsar with PolarLight, a miniature polarimeter utilising a novel technique onboard a CubeSat. The polarisation fraction of the Crab in the on-pulse phases was observed to decrease after a glitch of the Crab pulsar on July 23, 2019, while that of the pure nebular emission remained constant within uncertainty. The phenomenon may have lasted about 100 days. If the association between the glitch and polarisation change can be confirmed with future observations, it will place strong constraints on the physical mechanism of the high energy emission and glitch of pulsars.
△ Less
Submitted 10 November, 2020;
originally announced November 2020.
-
In-orbit Operation and Performance of the CubeSat Soft X-ray Polarimeter PolarLight
Authors:
Hong Li,
Xiangyun Long,
Hua Feng,
Qiong Wu,
Jiahui Huang,
Weichun Jiang,
Massimo Minuti,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri,
Paolo Soffitta,
Enrico Costa
Abstract:
PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we dis…
▽ More
PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we discuss how one can run a low-cost, shared CubeSat for space astronomy, and how CubeSats can play a role in modern space astronomy for technical demonstration, science observations, and student training.
△ Less
Submitted 2 September, 2020;
originally announced September 2020.
-
PolarLight: a CubeSat X-ray Polarimeter based on the Gas Pixel Detector
Authors:
Hua Feng,
Weichun Jiang,
Massimo Minuti,
Qiong Wu,
Aera Jung,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Jiahui Huang,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgrò,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri,
Paolo Soffitta,
Enrico Costa
Abstract:
The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the fi…
▽ More
The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the field of view to 2.3 degrees. Filled with pure dimethyl ether (DME) at 0.8 atm and sealed by a beryllium window of 100 micron thick, with a sensitive area of about 1.4 mm by 1.4 mm, PolarLight allows us to observe the brightest X-ray sources on the sky, with a count rate of, e.g., ~0.2 counts/s from the Crab nebula. The PolarLight is 1U in size and mounted in a 6U CubeSat, which was launched into a low Earth Sun-synchronous orbit on October 29, 2018, and is currently under test. More launches with improved designs are planned in 2019. These tests will help increase the technology readiness for future missions such as the enhanced X-ray Timing and Polarimetry (eXTP), better understand the orbital background, and may help constrain the physics with observations of the brightest objects.
△ Less
Submitted 4 March, 2019;
originally announced March 2019.
-
The enhanced X-ray Timing and Polarimetry mission - eXTP
Authors:
ShuangNan Zhang,
Andrea Santangelo,
Marco Feroci,
YuPeng Xu,
FangJun Lu,
Yong Chen,
Hua Feng,
Shu Zhang,
Søren Brandt,
Margarita Hernanz,
Luca Baldini,
Enrico Bozzo,
Riccardo Campana,
Alessandra De Rosa,
YongWei Dong,
Yuri Evangelista,
Vladimir Karas,
Norbert Meidinger,
Aline Meuris,
Kirpal Nandra,
Teng Pan,
Giovanni Pareschi,
Piotr Orleanski,
QiuShi Huang,
Stephane Schanne
, et al. (125 additional authors not shown)
Abstract:
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In ad…
▽ More
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Contributions of the Cherenkov Telescope Array (CTA) to the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
C. Adams,
G. Agnetta,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
J. Alfaro,
R. Alfaro,
A. J. Allafort,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
M. Anduze,
E. O. Angüner
, et al. (1387 additional authors not shown)
Abstract:
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
List of contributions from the Cherenkov Telescope Array (CTA) Consortium presented at the 6th International Symposium on High-Energy Gamma-Ray Astronomy (Gamma 2016), July 11-15, 2016, in Heidelberg, Germany.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Authors:
S. N. Zhang,
M. Feroci,
A. Santangelo,
Y. W. Dong,
H. Feng,
F. J. Lu,
K. Nandra,
Z. S. Wang,
S. Zhang,
E. Bozzo,
S. Brandt,
A. De Rosa,
L. J. Gou,
M. Hernanz,
M. van der Klis,
X. D. Li,
Y. Liu,
P. Orleanski,
G. Pareschi,
M. Pohl,
J. Poutanen,
J. L. Qu,
S. Schanne,
L. Stella,
P. Uttley
, et al. (160 additional authors not shown)
Abstract:
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time…
▽ More
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering <180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10 keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees FoV. The eXTP international consortium includes mostly major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
Assembly and Test of the Gas Pixel Detector for X-ray Polarimetry
Authors:
H. Li,
H. Feng,
F. Muleri,
R. Bellazzini,
M. Minuti,
P. Soffitta,
A. Brez,
G. Spandre,
M. Pinchera,
C. Sgro,
L. Baldini,
R. She,
E. Costa
Abstract:
The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is selected as the focal plane detector for the ESA medium-class mission concept X-ray Imaging and Polarimetry Explorer (XIPE). Here we show the design, assembly, and preliminary test results of a small GPD for the purpose of gas mixture optimization needed for the phase A study of XIPE. The detector is assembled in house a…
▽ More
The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is selected as the focal plane detector for the ESA medium-class mission concept X-ray Imaging and Polarimetry Explorer (XIPE). Here we show the design, assembly, and preliminary test results of a small GPD for the purpose of gas mixture optimization needed for the phase A study of XIPE. The detector is assembled in house at Tsinghua University following a design by the INFN-Pisa group. The improved detector design results in a good uniformity for the electric field. Filled with pure dimethyl ether (DME) at 0.8 atm, the measured energy resolution is 18% at 6 keV and inversely scales with the square root of the X-ray energy. The measured modulation factor is well consistent with that from simulation, up to ~0.6 above 6 keV. The residual modulation is found to be 0.30% +/- 0.15% at 6 keV for the whole sensitive area, which can be translated into a systematic error of less than 1% for polarization measurement at a confidence level of 99%. The position resolution of the detector is about 80 um in FWHM, consistent with previous studies and sufficient for XIPE requirements.
△ Less
Submitted 18 September, 2015;
originally announced September 2015.
-
LAMP: a micro-satellite based soft X-ray polarimeter for astrophysics
Authors:
Rui She,
Hua Feng,
Fabio Muleri,
Paolo Soffitta,
Renxin Xu,
Hong Li,
Ronaldo Bellazzini,
Zhanshan Wang,
Daniele Spiga,
Massimo Minuti,
Alessandro Brez,
Gloria Spandre,
Michele Pinchera,
Carmelo Sgro,
Luca Baldini,
Mingwu Wen,
Zhengxiang Shen,
Giovanni Pareschi,
Gianpiero Tagliaferri,
Kashmira Tayabaly,
Bianca Salmaso,
Yafeng Zhan
Abstract:
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite mission concept dedicated for astronomical X-ray polarimetry and is currently under early phase study. It consists of segmented paraboloidal multilayer mirrors with a collecting area of about 1300 cm^2 to reflect and focus 250 eV X-rays, which will be detected by position sensitive detectors at the focal plane. The primary t…
▽ More
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite mission concept dedicated for astronomical X-ray polarimetry and is currently under early phase study. It consists of segmented paraboloidal multilayer mirrors with a collecting area of about 1300 cm^2 to reflect and focus 250 eV X-rays, which will be detected by position sensitive detectors at the focal plane. The primary targets of LAMP include the thermal emission from the surface of pulsars and synchrotron emission produced by relativistic jets in blazars. With the expected sensitivity, it will allow us to detect polarization or place a tight upper limit for about 10 pulsars and 20 blazars. In addition to measuring magnetic structures in these objects, LAMP will also enable us to discover bare quark stars if they exist, whose thermal emission is expected to be zero polarized, while the thermal emission from neutron stars is believed to be highly polarized due to plasma polarization and the quantum electrodynamics (QED) effect. Here we present an overview of the mission concept, its science objectives and simulated observational results.
△ Less
Submitted 15 September, 2015;
originally announced September 2015.
-
INFN Camera demonstrator for the Cherenkov Telescope Array
Authors:
G. Ambrosi,
M. Ambrosio,
C. Aramo,
B. Bertucci,
E. Bissaldi,
M. Bitossi,
S. Brasolin,
G. Busetto,
R. Carosi,
S. Catalanotti,
M. A. Ciocci,
R. Consoletti,
P. Da Vela,
F. Dazzi,
A. De Angelis,
B. De Lotto,
F. de Palma,
R. Desiante,
T. Di Girolamo,
C. Di Giulio,
M. Doro,
D. D'Urso,
G. Ferraro,
F. Ferrarotto,
F. Gargano
, et al. (24 additional authors not shown)
Abstract:
The Cherenkov Telescope Array is a world-wide project for a new generation of ground-based Cherenkov telescopes of the Imaging class with the aim of exploring the highest energy region of the electromagnetic spectrum. With two planned arrays, one for each hemisphere, it will guarantee a good sky coverage in the energy range from a few tens of GeV to hundreds of TeV, with improved angular resolutio…
▽ More
The Cherenkov Telescope Array is a world-wide project for a new generation of ground-based Cherenkov telescopes of the Imaging class with the aim of exploring the highest energy region of the electromagnetic spectrum. With two planned arrays, one for each hemisphere, it will guarantee a good sky coverage in the energy range from a few tens of GeV to hundreds of TeV, with improved angular resolution and a sensitivity in the TeV energy region better by one order of magnitude than the currently operating arrays. In order to cover this wide energy range, three different telescope types are envisaged, with different mirror sizes and focal plane features. In particular, for the highest energies a possible design is a dual-mirror Schwarzschild-Couder optical scheme, with a compact focal plane. A silicon photomultiplier (SiPM) based camera is being proposed as a solution to match the dimensions of the pixel (angular size of ~ 0.17 degrees). INFN is developing a camera demonstrator made by 9 Photo Sensor Modules (PSMs, 64 pixels each, with total coverage 1/4 of the focal plane) equipped with FBK (Fondazione Bruno Kessler, Italy) Near UltraViolet High Fill factor SiPMs and Front-End Electronics (FEE) based on a Target 7 ASIC, a 16 channels fast sampler (up to 2GS/s) with deep buffer, self-trigger and on-demand digitization capabilities specifically developed for this purpose. The pixel dimensions of $6\times6$ mm$^2$ lead to a very compact design with challenging problems of thermal dissipation. A modular structure, made by copper frames hosting one PSM and the corresponding FEE, has been conceived, with a water cooling system to keep the required working temperature. The actual design, the adopted technical solutions and the achieved results for this demonstrator are presented and discussed.
△ Less
Submitted 7 September, 2015;
originally announced September 2015.
-
CTA Contributions to the 34th International Cosmic Ray Conference (ICRC2015)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio
, et al. (1290 additional authors not shown)
Abstract:
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
△ Less
Submitted 11 September, 2015; v1 submitted 24 August, 2015;
originally announced August 2015.
-
The imaging properties of the Gas Pixel Detector as a focal plane polarimeter
Authors:
S. Fabiani,
E. Costa,
E. Del Monte,
F. Muleri,
P. Soffitta,
A. Rubini,
R. Bellazzini,
A. Brez,
L. de Ruvo,
M. Minuti,
M. Pinchera,
C. Sgrò,
G. Spandre,
D. Spiga,
G. Tagliaferri,
G. Pareschi,
S. Basso,
O. Citterio,
V. Burwitz,
W. Burkert,
B. Menz,
G. Hartner
Abstract:
X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a te…
▽ More
X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time and the polarization angle of every single photon, allows to perform polarimetry of subsets of data singled out from the spectrum, the light curve or the image of source. The GPD has an intrinsic very fine imaging capability and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray test facility of the Max-Planck-Institut für extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it to a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the XIPE configuration, discussing also possible improvements by coupling the detector with advanced optics, having finer angular resolution and larger effective area, to study with more details extended objects.
△ Less
Submitted 27 March, 2014;
originally announced March 2014.
-
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Authors:
Daniele Spiga,
Gianpiero Tagliaferri,
Paolo Soffitta,
Oberto Citterio,
Stefano Basso,
Ronaldo Bellazzini,
Alessandro Brez,
Wolfgang Burkert,
Vadim Burwitz,
Enrico Costa,
Luca de Ruvo,
Ettore Del Monte,
Sergio Fabiani,
Gisela Hartner,
Benedikt Menz,
Massimo Minuti,
Fabio Muleri,
Giovanni Pareschi,
Michele Pinchera,
Alda Rubini,
Carmelo Sgrò,
Gloria Spandre
Abstract:
The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera…
▽ More
The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera Astronomical Observatory where they had been manufactured. After 16 years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel Detector (GPD) with polarimetric capabilities in the focal plane of the FM2. The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In the first phase of the test campaign, we have re-tested the FM2 at PANTER to have an up-to-date characterization in terms of angular resolution and effective area, while in the second part of the test the GPD has been placed in the focal plane of the FM2. In this paper we report the results of the tests of the sole FM2, using an unpolarized X-ray source, comparing the results with the calibration done in 1996.
△ Less
Submitted 18 February, 2014; v1 submitted 9 November, 2013;
originally announced November 2013.
-
XIPE: the X-ray Imaging Polarimetry Explorer
Authors:
Paolo Soffitta,
Xavier Barcons,
Ronaldo Bellazzini,
João Braga,
Enrico Costa,
George W. Fraser,
Szymon Gburek,
Juhani Huovelin,
Giorgio Matt,
Mark Pearce,
Juri Poutanen,
Victor Reglero,
Andrea Santangelo,
Rashid A. Sunyaev,
Gianpiero Tagliaferri,
Martin Weisskopf,
Roberto Aloisio,
Elena Amato,
Primo Attiná,
Magnus Axelsson,
Luca Baldini,
Stefano Basso,
Stefano Bianchi,
Pasquale Blasi,
Johan Bregeon
, et al. (74 additional authors not shown)
Abstract:
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and wh…
▽ More
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017 but not selected. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus and two additional GPDs filled with pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 % at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil).
△ Less
Submitted 26 September, 2013;
originally announced September 2013.
-
CTA contributions to the 33rd International Cosmic Ray Conference (ICRC2013)
Authors:
The CTA Consortium,
:,
O. Abril,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
M. Ajello,
A. Akhperjanian,
M. Alcubierre,
J. Aleksic,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
E. Amato,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
E. O. Angüner,
L. A. Antonelli,
V. Antonuccio
, et al. (1082 additional authors not shown)
Abstract:
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
△ Less
Submitted 29 July, 2013; v1 submitted 8 July, 2013;
originally announced July 2013.
-
Measurement of the position resolution of the Gas Pixel Detector
Authors:
Paolo Soffitta,
Fabio Muleri,
Sergio Fabiani,
Enrico Costa,
Ronaldo Bellazzini,
Alessandro Brez,
Massimo Minuti,
Michele Pinchera,
Gloria Spandre
Abstract:
The Gas Pixel Detector was designed and built as a focal plane instrument for X-ray polarimetry of celestial sources, the last unexplored subtopics of X-ray astronomy. It promises to perform detailed and sensitive measurements resolving extended sources and detecting polarization in faint sources in crowded fields at the focus of telescopes of good angular resolution. Its polarimetric and spectral…
▽ More
The Gas Pixel Detector was designed and built as a focal plane instrument for X-ray polarimetry of celestial sources, the last unexplored subtopics of X-ray astronomy. It promises to perform detailed and sensitive measurements resolving extended sources and detecting polarization in faint sources in crowded fields at the focus of telescopes of good angular resolution. Its polarimetric and spectral capability were already studied in earlier works. Here we investigate for the first time, with both laboratory measurements and Monte Carlo simulations, its imaging properties to confirm its unique capability to carry out imaging spectral-polarimetry in future X-ray missions.
△ Less
Submitted 30 August, 2012;
originally announced August 2012.
-
POLARIX: a pathfinder mission of X-ray polarimetry
Authors:
Enrico Costa,
Ronaldo Bellazzini,
Gianpiero Tagliaferri,
Giorgio Matt,
Andrea Argan,
Primo Attina',
Luca Baldini,
Stefano Basso,
Alessandro Brez,
Oberto Citterio,
Sergio Di Cosimo,
Vincenzo Cotroneo,
Sergio Fabiani,
Marco Feroci,
Antonella Ferri,
Luca Latronico,
Francesco Lazzarotto,
Massimo Minuti,
Ennio Morelli,
Fabio Muleri,
Lucio Nicolini,
Giovanni Pareschi,
Giuseppe Di Persio,
Michele Pinchera,
Massimiliano Razzano
, et al. (8 additional authors not shown)
Abstract:
Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a m…
▽ More
Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a mission dedicated to X-ray polarimetry. It exploits the polarimetric response of a Gas Pixel Detector, combined with position sensitivity, that, at the focus of a telescope, results in a huge increase of sensitivity. Three Gas Pixel Detectors are coupled with three X-ray optics which are the heritage of JET-X mission. POLARIX will measure time resolved X-ray polarization with an angular resolution of about 20 arcsec in a field of view of 15 arcmin $\times$ 15 arcmin and with an energy resolution of 20 % at 6 keV. The Minimum Detectable Polarization is 12 % for a source having a flux of 1 mCrab and 10^5 s of observing time. The satellite will be placed in an equatorial orbit of 505 km of altitude by a Vega launcher.The telemetry down-link station will be Malindi. The pointing of POLARIX satellite will be gyroless and it will perform a double pointing during the earth occultation of one source, so maximizing the scientific return. POLARIX data are for 75 % open to the community while 25 % + SVP (Science Verification Phase, 1 month of operation) is dedicated to a core program activity open to the contribution of associated scientists. The planned duration of the mission is one year plus three months of commissioning and SVP, suitable to perform most of the basic science within the reach of this instrument.
△ Less
Submitted 3 May, 2011;
originally announced May 2011.
-
Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether
Authors:
F. Muleri,
P. Soffitta,
L. Baldini,
R. Bellazzini,
A. Brez,
E. Costa,
S. Fabiani,
F. Krummenacher,
L. Latronico,
F. Lazzarotto,
M. Minuti,
M. Pinchera,
A. Rubini,
C. Sgro,
G. Spandre
Abstract:
The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric se…
▽ More
The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric sensitivity. Here we present the characterization of the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME) at 0.79 atm, selected among other mixtures for the very low diffusion coefficient. Almost completely polarized and monochromatic photons were produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg diffraction at nearly 45 degrees. For the first time ever, we measured the modulation factor and the spectral capabilities of the instrument at energies as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV. These measurements cover almost completely the energy range of the instrument and allows to compare the sensitivity achieved with that of the standard mixture, composed of helium and DME.
△ Less
Submitted 31 March, 2010;
originally announced March 2010.
-
X-ray polarimetry in Astrophysics with the Gas Pixel Detector
Authors:
F. Muleri,
R. Bellazzini,
A. Brez,
E. Costa,
F. Lazzarotto,
M. Minuti,
M. Pinchera,
A. Rubini,
P. Soffitta,
G. Spandre
Abstract:
The Gas Pixel Detector, recently developed and continuously improved by Pisa INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point and the original direction of the photoelectrons, the GPD can measure the linear polarization of X-rays, while preserving the information on the absorption p…
▽ More
The Gas Pixel Detector, recently developed and continuously improved by Pisa INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point and the original direction of the photoelectrons, the GPD can measure the linear polarization of X-rays, while preserving the information on the absorption point, the energy and the time of individual photons. Applied to X-ray Astrophysics, in the focus of grazing incidence telescopes, it can perform angular resolved polarimetry with a huge improvement of sensitivity, when compared with the conventional techniques of Bragg diffraction at 45 degrees and Compton scattering around 90 degrees. This configuration is the basis of POLARIX and HXMT, two pathfinder missions, and is included in the baseline design of IXO, the very large X-ray telescope under study by NASA, ESA and JAXA.
△ Less
Submitted 30 November, 2009;
originally announced November 2009.
-
X-ray polarimetry on-board HXMT
Authors:
Paolo Soffitta,
Ronaldo Bellazzini,
Gianpiero Tagliaferri,
Enrico Costa,
Giovanni Pareschi,
Stefano Basso,
Vincenzo Cotroneo,
Massimo Frutti,
Francesco Lazzarotto,
Fabio Muleri,
Alda Rubini,
Gloria Spandre,
Alessandro Brez,
Luca Baldini,
Jean Bregeon,
Massimo Minuti,
Giorgio Matt,
Filippo Frontera
Abstract:
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fractio…
▽ More
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter (EXP2, Efficient X-ray Photoelectric Polarimeter) in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources, the proposed instrument can represent a breakthrough in X-ray Polarimetry.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
XPOL: a photoelectric polarimeter onboard XEUS
Authors:
Enrico Costa,
Ronaldo Bellazzini,
Jean Bregeon,
Alessandro Brez,
Massimo Frutti,
Sergio Di Cosimo,
Luca Latronicio,
Francesco Lazzarotto,
Giorgio Matt,
Massimo Minuti,
Ennio Morelli,
Fabio Muleri,
Michele Pinchera,
Massimiliano Razzano,
Alda Rubini,
Paolo Soffitta,
Gloria Spandre
Abstract:
The XEUS mission incorporates two satellites: the Mirror Spacecraft with 5 m2 of collecting area at 1 keV and 2 m2 at 7 keV, and an imaging resolution of 5" HEW and the Payload Spacecraft which carries the focal plane instrumentation. XEUS was submitted to ESA Cosmic Vision and was selected for an advanced study as a large mission. The baseline design includes XPOL, a polarimeter based on the ph…
▽ More
The XEUS mission incorporates two satellites: the Mirror Spacecraft with 5 m2 of collecting area at 1 keV and 2 m2 at 7 keV, and an imaging resolution of 5" HEW and the Payload Spacecraft which carries the focal plane instrumentation. XEUS was submitted to ESA Cosmic Vision and was selected for an advanced study as a large mission. The baseline design includes XPOL, a polarimeter based on the photoelectric effect, that takes advantage of the large effective area which permits the study of the faint sources and of the long focal length, resulting in a very good spatial resolution, which allows the study of spatial features in extended sources. We show how, with XEUS, Polarimetry becomes an efficient tool at disposition of the Astronomical community.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
The Gas Pixel Detector as an X-ray photoelectric polarimeter with a large field of view
Authors:
Fabio Muleri,
Paolo Soffitta,
Ronaldo Bellazzini,
Alessandro Brez,
Enrico Costa,
Sergio Fabiani,
Massimo Frutti,
Massimo Minuti,
Maria Barbara Negri,
Michele Pinchera,
Alda Rubini,
Gloria Spandre
Abstract:
The Gas Pixel Detector (GPD) is a new generation device which, thanks to its 50 um pixels, is capable of imaging the photoelectrons tracks produced by photoelectric absorption in a gas. Since the direction of emission of the photoelectrons is strongly correlated with the direction of polarization of the absorbed photons, this device has been proposed as a polarimeter for the study of astrophysic…
▽ More
The Gas Pixel Detector (GPD) is a new generation device which, thanks to its 50 um pixels, is capable of imaging the photoelectrons tracks produced by photoelectric absorption in a gas. Since the direction of emission of the photoelectrons is strongly correlated with the direction of polarization of the absorbed photons, this device has been proposed as a polarimeter for the study of astrophysical sources, with a sensitivity far higher than the instruments flown to date. The GPD has been always regarded as a focal plane instrument and then it has been proposed to be included on the next generation space-borne missions together with a grazing incidence optics. Instead in this paper we explore the feasibility of a new kind of application of the GPD and of the photoelectric polarimeters in general, i.e. an instrument with a large field of view. By means of an analytical treatment and measurements, we verify if it is possible to preserve the sensitivity to the polarization for inclined beams, opening the way for the measurement of X-ray polarization for transient astrophysical sources. While severe systematic effects arise for inclination greater than about 20 degrees, methods and algorithms to control them are discussed.
△ Less
Submitted 15 October, 2008;
originally announced October 2008.
-
Low energy polarization sensitivity of the Gas Pixel Detector
Authors:
F. Muleri,
P. Soffitta,
L. Baldini,
R. Bellazzini,
J. Bregeon,
A. Brez,
E. Costa,
M. Frutti,
L. Latronico,
M. Minuti,
M. B. Negri,
N. Omodei,
M. Pinchera,
M. Pesce-Rollins,
M. Razzano,
A. Rubini,
C. Sgro',
G. Spandre
Abstract:
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3 keV, but the lack of readily available…
▽ More
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3 keV, but the lack of readily available polarized sources in this energy range has prevented the measurement of detector polarimetric performances.
In this paper we present the measurement of the Gas Pixel Detector polarimetric sensitivity at energies of a few keV and the new, light, compact and transportable polarized source that was devised and built to this aim. Polarized photons are produced, from unpolarized radiation generated with an X-ray tube, by means of Bragg diffraction at nearly 45 degrees.
The employment of mosaic graphite and flat aluminum crystals allow the production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from the diffraction of unpolarized continuum or line emission. The measured modulation factor of the Gas Pixel Detector at these energies is in good agreement with the estimates derived from a Monte Carlo software, which was up to now employed for driving the development of the instrument and for estimating its low energy sensitivity. In this paper we present the excellent polarimetric performance of the Gas Pixel Detector at energies where the peak sensitivity is expected. These measurements not only support our previous claims of high sensitivity but confirm the feasibility of astrophysical X-ray photoelectric polarimetry.
△ Less
Submitted 28 September, 2007;
originally announced September 2007.
-
An X-ray Polarimeter for HXMT Mission
Authors:
Enrico Costa,
Ronaldo Bellazzini,
Gianpiero Tagliaferri,
Luca Baldini,
Stefano Basso,
Johan Bregeon,
Alessandro Brez,
Oberto Citterio,
Vincenzo Cotroneo,
Filippo Frontera,
Massimo Frutti,
Giorgio Matt,
Massimo Minuti,
Fabio Muleri,
Giovanni Pareschi,
Giuseppe Cesare Perola,
Alda Rubini,
Carmelo Sgro',
Paolo Soffitta,
Gloria Spandre
Abstract:
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fractio…
▽ More
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources the proposed instrument can represent a breakthrough in X-ray Polarimetry.
△ Less
Submitted 25 September, 2007;
originally announced September 2007.
-
A very compact polarizer for an X-ray polarimeter calibration
Authors:
Fabio Muleri,
Paolo Soffitta,
Ronaldo Bellazzini,
Alessandro Brez,
Enrico Costa,
Sergio Fabiani,
Massimo Frutti,
Massimo Minuti,
Maria Barbara Negri,
Piermarco Pascale,
Alda Rubini,
Giuseppe Sindoni,
Gloria Spandre
Abstract:
We devised and built a light, compact and transportable X-ray polarized source based on the Bragg diffraction at nearly 45 degrees. The source is composed by a crystal coupled to a small power X-ray tube. The angles of incidence are selected by means of two orthogonal capillary plates which, due to the small diameter holes (10 um) allow good collimation with limited sizes. All the orders of diff…
▽ More
We devised and built a light, compact and transportable X-ray polarized source based on the Bragg diffraction at nearly 45 degrees. The source is composed by a crystal coupled to a small power X-ray tube. The angles of incidence are selected by means of two orthogonal capillary plates which, due to the small diameter holes (10 um) allow good collimation with limited sizes. All the orders of diffraction defined by the crystal lattice spacing are polarized up to the maximum order limited by the X-ray tube voltage. Selecting suitably the crystal and the X-ray tube, either the line or the continuum emission can be diffracted, producing polarized photons at different energies. A very high degree of polarization and reasonable fluxes can be reached with a suitable choice of the capillary plates collimation.
We present the source and test its performances with the production of nearly completely polarized radiation at 2.6, 5.2, 3.7 and 7.4 keV thanks to the employment of graphite and aluminum crystals, with copper and calcium X-ray tubes respectively. Triggered by the very compact design of the source, we also present a feasibility study for an on-board polarized source, coupled to a radioactive Fe55 nuclide and a PVC thin film, for the calibration of the next generation space-borne X-ray polarimeters at 2.6 and 5.9 keV.
△ Less
Submitted 25 September, 2007;
originally announced September 2007.
-
Imaging with the invisible light
Authors:
R. Bellazzini,
G. Spandre,
A. Brez,
M. Minuti,
L. Baldini,
L. Latronico,
M. M. Massai,
N. Omodei,
M. Pesce-Rollins,
C Sgró,
M. Razzano,
M. Pinchera,
J. Bregeon,
M. Kuss,
A. Braem
Abstract:
We describe a UV photo-detector with single photon(electron) counting and imaging capability. It is based on a CsI photocathode, a GEM charge multiplier and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron pitch. The single photoelectron produced by the absorption of a UV photon is drifted to and multiplied inside a single GEM hole. The coordinates of the GEM avalanche are…
▽ More
We describe a UV photo-detector with single photon(electron) counting and imaging capability. It is based on a CsI photocathode, a GEM charge multiplier and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron pitch. The single photoelectron produced by the absorption of a UV photon is drifted to and multiplied inside a single GEM hole. The coordinates of the GEM avalanche are reconstructed with high accuracy (4 micron rms) by the pixel chip. As a result the map of the GEM holes, arranged on a triangular pattern at 50micron pitch, is finely imaged.
△ Less
Submitted 20 March, 2007; v1 submitted 19 March, 2007;
originally announced March 2007.
-
A Sealed Gas Pixel Detector for X-ray Astronomy
Authors:
R. Bellazzini,
G. Spandre,
M. Minuti,
L. Baldini,
A. Brez,
L. Latronico,
N. Omodei,
M. Razzano,
M. M. Massai,
M. Pinchera,
M. Pesce-Rollins,
C. Sgro,
E. Costa,
P. Soffitta,
H. Sipila,
E. Lempinen
Abstract:
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The instrument brings high sensitivity to X-ray polarimetry, which is the last unexplored field of X-ray astronomy. It derives the polarization information from the…
▽ More
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The instrument brings high sensitivity to X-ray polarimetry, which is the last unexplored field of X-ray astronomy. It derives the polarization information from the track of the photoelectrons that are imaged by a high gain (>1000), fine pitch GEM that matches the pitch of a pixel ASIC which is the collecting anode of the GPD (105k, 50 micron wide, hexagonal cells). The device is able to simultaneously perform good imaging (50-60 micron), moderate spectroscopy (~15% at 6 keV) as well as fast, high rate timing in the 1-10keV range. Moreover, being truly 2D, it is non dispersive and does not require any rotation. The great improvement of sensitivity, at least two orders of magnitude with respect to traditional polarimeters (based on Bragg crystals or Thomson scattering), will allow the direct exploration of the most dramatic objects of the X-ray sky. At the focus of the large mirror area of the XEUS telescope it will be decisive in reaching many of the scientific goals of the mission. With integration times of the order of one day, polarimetry of Active Galactic Nuclei at the per cent level will be possible, making for a real breakthrough in high energy astrophysics.
△ Less
Submitted 20 November, 2006; v1 submitted 16 November, 2006;
originally announced November 2006.
-
Direct reading of charge multipliers with a self-triggering CMOS analog chip with 105k pixels at 50 micron pitch
Authors:
R. Bellazzini,
G. Spandre,
M. Minuti,
L. Baldini,
A. Brez,
F. Cavalca,
L. Latronico,
N. Omodei,
M. M. Massai,
C. Sgro,
E. Costa,
P. Soffitta F. Krummenacher,
R. DeOliveira
Abstract:
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel…
▽ More
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel array has the top metal layer patterned in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is directly connected to the underneath full electronics chain which has been realized in the remaining five metal and two poly-silicon layers of a 0.18 micron VLSI technology. The chip has customizable self-triggering capability and includes a signal pre-processing function for the automatic localization of the event coordinates. In this way it is possible to reduce significantly the readout time and the data volume by limiting the signal output only to those pixels belonging to the region of interest. The very small pixel area and the use of a deep sub-micron CMOS technology has brought the noise down to 50 electrons ENC. Results from in depth tests of this device when coupled to a fine pitch (50 micron on a triangular pattern) Gas Electron Multiplier are presented. The matching of readout and gas amplification pitch allows to get optimal results. The application of this detector for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation when working with two gas mixtures and two different photon energies is shown. Results from a full MonteCarlo simulation for several galactic and extragalactic atronomical sources are also reported.
△ Less
Submitted 26 April, 2006; v1 submitted 14 April, 2006;
originally announced April 2006.
-
Gas Pixel Detectors for X-ray Polarimetry applications
Authors:
R. Bellazzini,
F. Angelini,
L. Baldini,
F. Bitti,
A. Brez,
F. Cavalca,
M. Del Prete,
M. Kuss,
L. Latronico,
N. Omodei,
M. Pinchera,
M. M. Massai,
M. Minuti,
M. Razzano,
C. Sgro,
G. Spandre,
A. Tenze,
E. Costa,
P. Soffitta
Abstract:
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting…
▽ More
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting electrode and the amplifying, shaping and charge measuring front-end electronics. The CMOS chip has the top metal layer patterned in a matrix of 80 micron pitch hexagonal pixels, each of them directly connected to the underneath electronics chain which has been realized in the remaining five layers of the 0.35 micron VLSI technology. Results from tests of a first prototype of such detector with 2k pixels and a full scale version with 22k pixels are presented. The application of this device for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation is shown. Results from a full MonteCarlo simulation for two astronomical sources, the Crab Nebula and the Hercules X1, are also reported.
△ Less
Submitted 8 February, 2006; v1 submitted 9 December, 2005;
originally announced December 2005.
-
Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode
Authors:
R. Bellazzini,
F. Angelini,
L. Baldini,
F. Bitti,
A. Brez,
L. Latronico,
M. M. Massai,
M. Minuti,
N. Omodei,
M. Razzano,
C. Sgro,
G. Spandre,
E. Costa,
P. Soffitta
Abstract:
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 micron pitch, directly used as the charge colle…
▽ More
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 micron pitch, directly used as the charge collecting anode of a GEM amplifying structure, has been developed and built. Each charge collecting pad, hexagonally shaped, realized using the top metal layer of a deep submicron VLSI technology is individually connected to a full electronics chain (pre-amplifier, shaping-amplifier, sample and hold, multiplexer) which is built immediately below it by using the remaining five active layers. The GEM and the drift electrode window are assembled directly over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern Gas Detector. With this approach, for the first time, gas detectors have reached the level of integration and resolution typical of solid state pixel detectors. Results from the first tests of this new read-out concept are presented. An Astronomical X-Ray Polarimetry application is also discussed.
△ Less
Submitted 1 March, 2004;
originally announced March 2004.