-
Measuring the CMB primordial B-modes with Bolometric Interferometry
Authors:
A. Mennella,
P. Ade,
A. Almela,
G. Amico,
L. H. Arnaldi,
J. Aumont,
S. Banfi,
E. S. Battistelli,
B. Bélier,
L. Bergé,
J. -Ph. Bernard,
P. de Bernardis,
M. Bersanelli,
J. Bonaparte,
J. D. Bonilla,
E. Bunn,
D. Buzi,
F. Cacciotti,
D. Camilieri,
F. Cavaliere,
P. Chanial,
C. Chapron,
L. Colombo,
F. Columbro,
A. Coppolecchia
, et al. (89 additional authors not shown)
Abstract:
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest fo…
▽ More
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest for the faint signal of the primordial B-modes. A unique feature is the so-called "spectral imaging", i.e., the ability to recover the sky signal in several sub-bands within the physical band during data analysis. This feature provides an in-band spectral resolution of Δν/ν \sim 0.04 that is unattainable by a traditional imager. This is a key tool for controlling the Galactic foregrounds contamination. In this paper, we describe the principles of bolometric interferometry, the current status of the QUBIC experiment and future prospects.
△ Less
Submitted 5 November, 2023;
originally announced November 2023.
-
Status of QUBIC, the Q&U Bolometer for Cosmology
Authors:
L. Mousset,
P. Ade,
A. Almela,
G. Amico,
L. H. Arnaldi,
J. Aumont,
S. Banfi,
E. S. Battistelli,
B. Bélier,
L. Bergé,
J. -Ph. Bernard,
P. de Bernardis,
M. Bersanelli,
J. Bonaparte,
J. D. Bonilla,
E. Bunn,
D. Buzi,
D. Camilieri,
F. Cavaliere,
P. Chanial,
C. Chapron,
S. Colombo,
F. Columbro,
A. Coppolecchia,
B. Costanza
, et al. (86 additional authors not shown)
Abstract:
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Back-ground (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregr…
▽ More
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Back-ground (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematics with those of bolometric detectors in terms of wide-band, background-limited sensitivity.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
High angular resolution Sunyaev Zel'dovich observations: the case of MISTRAL
Authors:
E. S. Battistelli,
E. Barbavara,
P. de Bernardis,
F. Cacciotti,
V. Capalbo,
E. Carretti,
F. Columbro,
A. Coppolecchia,
A. Cruciani,
G. D'Alessandro,
M. De Petris,
F. Govoni,
G. Isopi,
L. Lamagna,
P. Marongiu,
S. Masi,
L. Mele,
E. Molinari,
M. Murgia,
A. Navarrini,
A. Orlati,
A. Paiella,
G. Pettinari,
F. Piacentini,
T. Pisanu
, et al. (3 additional authors not shown)
Abstract:
The MIllimeter Sardinia radio Telescope Receiver based on Array of Lumped elements kids, MISTRAL, is a millimetric ($\simeq 90GHz$) multipixel camera being built for the Sardinia Radio Telescope. It is going to be a facility instrument and will sample the sky with 12 arcsec angular resolution, 4 arcmin field of view, through 408 Kinetic Inductance Detectors (KIDs). The construction and the beginni…
▽ More
The MIllimeter Sardinia radio Telescope Receiver based on Array of Lumped elements kids, MISTRAL, is a millimetric ($\simeq 90GHz$) multipixel camera being built for the Sardinia Radio Telescope. It is going to be a facility instrument and will sample the sky with 12 arcsec angular resolution, 4 arcmin field of view, through 408 Kinetic Inductance Detectors (KIDs). The construction and the beginning of commissioning is planned to be in 2022. MISTRAL will allow the scientific community to propose a wide variety of scientific cases including protoplanetary discs study, star forming regions, galaxies radial profiles, and high angular resolution measurements of the Sunyaev Zel'dovich (SZ) effect with the investigation of the morphology of galaxy cluster and the search for the Cosmic Web.
△ Less
Submitted 8 April, 2022;
originally announced April 2022.
-
Probing Cosmic Inflation with the LiteBIRD Cosmic Microwave Background Polarization Survey
Authors:
LiteBIRD Collaboration,
E. Allys,
K. Arnold,
J. Aumont,
R. Aurlien,
S. Azzoni,
C. Baccigalupi,
A. J. Banday,
R. Banerji,
R. B. Barreiro,
N. Bartolo,
L. Bautista,
D. Beck,
S. Beckman,
M. Bersanelli,
F. Boulanger,
M. Brilenkov,
M. Bucher,
E. Calabrese,
P. Campeti,
A. Carones,
F. J. Casas,
A. Catalano,
V. Chan,
K. Cheung
, et al. (166 additional authors not shown)
Abstract:
LiteBIRD, the Lite (Light) satellite for the study of B-mode polarization and Inflation from cosmic background Radiation Detection, is a space mission for primordial cosmology and fundamental physics. The Japan Aerospace Exploration Agency (JAXA) selected LiteBIRD in May 2019 as a strategic large-class (L-class) mission, with an expected launch in the late 2020s using JAXA's H3 rocket. LiteBIRD is…
▽ More
LiteBIRD, the Lite (Light) satellite for the study of B-mode polarization and Inflation from cosmic background Radiation Detection, is a space mission for primordial cosmology and fundamental physics. The Japan Aerospace Exploration Agency (JAXA) selected LiteBIRD in May 2019 as a strategic large-class (L-class) mission, with an expected launch in the late 2020s using JAXA's H3 rocket. LiteBIRD is planned to orbit the Sun-Earth Lagrangian point L2, where it will map the cosmic microwave background (CMB) polarization over the entire sky for three years, with three telescopes in 15 frequency bands between 34 and 448 GHz, to achieve an unprecedented total sensitivity of 2.2$μ$K-arcmin, with a typical angular resolution of 0.5$^\circ$ at 100 GHz. The primary scientific objective of LiteBIRD is to search for the signal from cosmic inflation, either making a discovery or ruling out well-motivated inflationary models. The measurements of LiteBIRD will also provide us with insight into the quantum nature of gravity and other new physics beyond the standard models of particle physics and cosmology. We provide an overview of the LiteBIRD project, including scientific objectives, mission and system requirements, operation concept, spacecraft and payload module design, expected scientific outcomes, potential design extensions and synergies with other projects.
△ Less
Submitted 27 March, 2023; v1 submitted 6 February, 2022;
originally announced February 2022.
-
The COSmic Monopole Observer (COSMO)
Authors:
S. Masi,
E. Battistelli,
P. de Bernardis,
A. Coppolecchia,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Lamagna,
E. Marchitelli,
L. Mele,
A. Paiella,
F. Piacentini,
G. Pisano,
M. Bersanelli,
C. Franceschet,
E. Manzan,
D. Mennella,
S. Realini,
S. Cibella,
F. Martini,
G. Pettinari,
G. Coppi,
M. Gervasi,
A. Limonta,
M. Zannoni
, et al. (2 additional authors not shown)
Abstract:
The COSmic Monopole Observer (COSMO) is an experiment to measure low-level spectral distortions in the isotropic component of the Cosmic Microwave Background (CMB). Deviations from a pure blackbody spectrum are expected at low level ($<$ 1 ppm) due to several astrophysical and cosmological phenomena, and promise to provide important independent information on the early and late phases of the unive…
▽ More
The COSmic Monopole Observer (COSMO) is an experiment to measure low-level spectral distortions in the isotropic component of the Cosmic Microwave Background (CMB). Deviations from a pure blackbody spectrum are expected at low level ($<$ 1 ppm) due to several astrophysical and cosmological phenomena, and promise to provide important independent information on the early and late phases of the universe. They have not been detected yet, due to the extreme accuracy required, the best upper limits being still those from the COBE-FIRAS mission. COSMO is based on a cryogenic differential Fourier Transform Spectrometer, measuring the spectral brightness difference between the sky and an accurate cryogenic blackbody. The first implementation of COSMO, funded by the Italian PRIN and PNRA programs, will operate from the Concordia station at Dome-C, in Antarctica, and will take advantage of a fast sky-dip technique to get rid of atmospheric emission and its fluctuations, separating them from the monopole component of the sky brightness. Here we describe the instrument design, its capabilities, the current status. We also discuss its subsequent implementation in a balloon-flight, which has been studied within the COSMOS program of the Italian Space Agency.
△ Less
Submitted 23 October, 2021;
originally announced October 2021.
-
The Crab Nebula as a Calibrator for wide-beam Cosmic Microwave Background polarization surveys
Authors:
Silvia Masi,
Paolo de Bernardis,
Fabio Columbro,
Alessandro Coppolecchia,
Giuseppe D'Alessandro,
Lorenzo Mele,
Alessandro Paiella,
Francesco Piacentini
Abstract:
We analyze the effect of polarized diffuse emission in the calibration of wide-beam mm-wave polarimeters, when using the Crab Nebula as a reference source for both polarized brightness and polarization angle. We show that, for CMB polarization experiments aiming at detecting B-mode in a scenario with a tensor to scalar ratio $r \sim 0.001$, wide (a few degrees in diameter), precise ($σ_Q$ , $σ_U$…
▽ More
We analyze the effect of polarized diffuse emission in the calibration of wide-beam mm-wave polarimeters, when using the Crab Nebula as a reference source for both polarized brightness and polarization angle. We show that, for CMB polarization experiments aiming at detecting B-mode in a scenario with a tensor to scalar ratio $r \sim 0.001$, wide (a few degrees in diameter), precise ($σ_Q$ , $σ_U$ $\sim$ 20 $μ$$K_{CMB}$ arcmin), high angular resolution ($< \mathrm{FWHM}$) reference maps are needed to properly take into account the effects of diffuse polarized emission and avoid significant bias in the calibration.
△ Less
Submitted 9 June, 2021;
originally announced June 2021.
-
QUBIC IV: Performance of TES Bolometers and Readout Electronics
Authors:
M. Piat,
G. Stankowiak,
E. S. Battistelli,
P. de Bernardis,
G. D Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
T. D. Hoang,
S. Marnieros,
S. Masi,
A. Mennella,
L. Mousset,
C. O Sullivan,
D. Prele,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi
, et al. (104 additional authors not shown)
Abstract:
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are…
▽ More
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are controlled and amplified by an SiGe application specific integrated circuit at 40 K. We report the performance of this readout chain and the characterization of the TES. The readout system has been functionally tested and characterized in the lab and in QUBIC. The low noise amplifier demonstrated a white noise level of 0.3 nV.Hz^-0.5. Characterizations of the QUBIC detectors and readout electronics includes the measurement of I-V curves, time constant and the noise equivalent power. The QUBIC TES bolometer array has approximately 80% detectors within operational parameters. It demonstrated a thermal decoupling compatible with a phonon noise of about 5.10^-17 W.Hz^-0.5 at 410 mK critical temperature. While still limited by microphonics from the pulse tubes and noise aliasing from readout system, the instrument noise equivalent power is about 2.10^-16 W.Hz^-0.5, enough for the demonstration of bolometric interferometry.
△ Less
Submitted 20 October, 2021; v1 submitted 17 January, 2021;
originally announced January 2021.
-
QUBIC I: Overview and ScienceProgram
Authors:
J. -Ch. Hamilton,
L. Mousset,
E. S. Battistelli,
M. -A. Bigot-Sazy,
P. Chanial,
R. Charlassier,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
M. M. Gamboa Lerena,
L. Grandsire,
S. Lau,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
M. Piat,
G. Riccardi,
C. Scóccola,
M. Stolpovskiy,
A. Tartari,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade
, et al. (105 additional authors not shown)
Abstract:
The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical fo…
▽ More
The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.
△ Less
Submitted 26 August, 2021; v1 submitted 4 November, 2020;
originally announced November 2020.
-
QUBIC II: Spectro-Polarimetry with Bolometric Interferometry
Authors:
L. Mousset,
M. M. Gamboa Lerena,
E. S. Battistelli,
P. de Bernardis,
P. Chanial,
G. D'Alessandro,
G. Dashyan,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
F. Incardona,
S. Landau,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
M. Piat,
G. Ricciardi,
C. G. Scóccola,
M. Stolpovskiy,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (106 additional authors not shown)
Abstract:
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foreg…
▽ More
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.
△ Less
Submitted 28 March, 2022; v1 submitted 28 October, 2020;
originally announced October 2020.
-
QUBIC VII: The feedhorn-switch system of the technological demonstrator
Authors:
F. Cavaliere,
A. Mennella,
M. Zannoni,
P. Battaglia,
E. S. Battistelli,
D. Burke,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
C. Franceschet,
L. Grandsire,
J. -Ch. Hamilton,
B. Maffei,
E. Manzan,
S. Marnieros,
S. Masi,
C. O'Sullivan,
A. Passerini,
F. Pezzotta,
M. Piat,
A. Tartari,
S. A. Torchinsky,
D. Viganò,
F. Voisin,
P. Ade
, et al. (106 additional authors not shown)
Abstract:
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration…
▽ More
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.
△ Less
Submitted 1 April, 2022; v1 submitted 28 August, 2020;
originally announced August 2020.
-
The large scale polarization explorer (LSPE) for CMB measurements: performance forecast
Authors:
The LSPE collaboration,
G. Addamo,
P. A. R. Ade,
C. Baccigalupi,
A. M. Baldini,
P. M. Battaglia,
E. S. Battistelli,
A. Baù,
P. de Bernardis,
M. Bersanelli,
M. Biasotti,
A. Boscaleri,
B. Caccianiga,
S. Caprioli,
F. Cavaliere,
F. Cei,
K. A. Cleary,
F. Columbro,
G. Coppi,
A. Coppolecchia,
F. Cuttaia,
G. D'Alessandro,
G. De Gasperis,
M. De Petris,
V. Fafone
, et al. (80 additional authors not shown)
Abstract:
[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very ear…
▽ More
[Abridged] The measurement of the polarization of the Cosmic Microwave Background radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial B-modes, could reveal the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: Strip, a radiometer-based telescope on the ground in Tenerife, and SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2021/22 for SWIPE, with a flight duration up to 15 days, and in Summer 2021 with two years observations for Strip. We describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact into performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE can reach a sensitivity in tensor-to-scalar ratio of $σ_r<0.01$, and improve constrains on other cosmological parameters.
△ Less
Submitted 9 August, 2021; v1 submitted 25 August, 2020;
originally announced August 2020.
-
QUBIC VI: cryogenic half wave plate rotator, design and performances
Authors:
G. D'Alessandro,
L. Mele,
F. Columbro,
G. Amico,
E. S. Battistelli,
P. de Bernardis,
A. Coppolecchia,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
L. Lamagna,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
G. Pisano,
G. Presta,
A. Tartari,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade
, et al. (104 additional authors not shown)
Abstract:
Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used t…
▽ More
Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).
△ Less
Submitted 19 November, 2020; v1 submitted 24 August, 2020;
originally announced August 2020.
-
QUBIC V: Cryogenic system design and performance
Authors:
S. Masi,
E. S. Battistelli,
P. de Bernardis,
C. Chapron,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
L. Mele,
A. May,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
L. Piccirillo,
G. Presta,
A. Schillaci,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (104 additional authors not shown)
Abstract:
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interfe…
▽ More
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.
△ Less
Submitted 25 August, 2021; v1 submitted 24 August, 2020;
originally announced August 2020.
-
QUBIC VIII: Optical design and performance
Authors:
C. O'Sullivan,
M. De Petris,
G. Amico,
E. S. Battistelli,
D. Burke,
D. Buzi,
C. Chapron,
L. Conversi,
G. D'Alessandro,
P. de Bernardis,
M. De Leo,
D. Gayer,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
S. Masi,
A. Mattei,
A. Mennella,
L. Mousset,
J. D. Murphy,
A. Pelosi,
M. Perciballi,
M. Piat,
S. Scully,
A. Tartari
, et al. (104 additional authors not shown)
Abstract:
The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or p…
▽ More
The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or planned experiments using the novel technique of bolometric interferometry. This technique takes advantage of the sensitivity of an imager and the systematic error control of an interferometer. A cold reflective optical combiner superimposes there-emitted beams from 400 aperture feedhorns on two focal planes. A shielding system composedof a fixed groundshield, and a forebaffle that moves with the instrument, limits the impact of local contaminants. The modelling, design, manufacturing and preliminary measurements of the optical components are described in this paper.
△ Less
Submitted 25 August, 2021; v1 submitted 23 August, 2020;
originally announced August 2020.
-
QUBIC III: Laboratory Characterization
Authors:
S. A. Torchinsky,
J. -Ch. Hamilton,
M. Piat,
E. S. Battistelli,
C. Chapron,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
M. M. Gamboa Lerena,
M. González,
L. Grandsire,
S. Masi,
S. Marnieros,
A. Mennella,
L. Mousset,
J. D. Murphy,
D. Prêle,
G. Stankowiak,
C. O'Sullivan,
A. Tartari,
J. -P. Thermeau,
F. Voisin,
M. Zannoni,
P. Ade,
J. G. Alberro
, et al. (103 additional authors not shown)
Abstract:
A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam,…
▽ More
A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.
△ Less
Submitted 15 March, 2022; v1 submitted 23 August, 2020;
originally announced August 2020.
-
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Authors:
E. S. Battistelli,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi,
D. Auguste,
J. Aumont,
S. Azzoni,
S. Banfi,
P. Battaglia,
A. Baù,
B. Bèlier,
D. Bennett,
L. Bergè,
J. -Ph. Bernard,
M. Bersanelli,
M. -A. Bigot-Sazy,
N. Bleurvacq,
J. Bonaparte,
J. Bonis,
A. Bottani,
E. Bunn,
D. Burke,
D. Buzi
, et al. (114 additional authors not shown)
Abstract:
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addr…
▽ More
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.
△ Less
Submitted 28 January, 2020;
originally announced January 2020.
-
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
Authors:
M. Piat,
B. Bélier,
L. Bergé,
N. Bleurvacq,
C. Chapron,
S. Dheilly,
L. Dumoulin,
M. González,
L. Grandsire,
J. -Ch. Hamilton,
S. Henrot-Versillé,
D. T. Hoang,
S. Marnieros,
W. Marty,
L. Montier,
E. Olivieri,
C. Oriol,
C. Perbost,
D. Prêle,
D. Rambaud,
M. Salatino,
G. Stankowiak,
J. -P. Thermeau,
S. Torchinsky,
F. Voisin
, et al. (113 additional authors not shown)
Abstract:
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detec…
▽ More
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.
△ Less
Submitted 9 December, 2019; v1 submitted 27 November, 2019;
originally announced November 2019.
-
Systematic effects induced by Half Wave Plate precession into Cosmic Microwave Background polarization measurements
Authors:
G. D'Alessandro,
L. Mele,
F. Columbro,
L. Pagano,
F. Piacentini,
P. de Bernardis,
S. Masi
Abstract:
The most accessible method to measure polarization features of the CMB radiation is by means of a Stokes Polarimeter based on the rotation of an Half Wave Plate. The current observational cosmology is starting to be limited by the presence of systematic effects. The Stokes polarimeter with a rotating Half Wave Plate (HWP) has the advantage of mitigating a long list of potential systematics, by mod…
▽ More
The most accessible method to measure polarization features of the CMB radiation is by means of a Stokes Polarimeter based on the rotation of an Half Wave Plate. The current observational cosmology is starting to be limited by the presence of systematic effects. The Stokes polarimeter with a rotating Half Wave Plate (HWP) has the advantage of mitigating a long list of potential systematics, by modulation of the linearly polarized component of the radiation, but the presence of the rotating HWP can by itself introduce new systematic effects, which must be under control, representing one of the most critical part in the design of a B-Modes experiment. In this paper we present, simulate and analyse the spurious signal arising from the precession of a rotating HWP. We first find an analytical formula for the impact of the systematic effect induced by the HWP precession on the propagating radiation, using the 3D generalization of the Muller formalism. We then perform several numerical simulations, showing the effect induced on the Stokes parameters by this systematic. We also derive and discuss the impact into B-modes measured by a satellite experiment. We find the analytical formula for the Stokes parameters from a Stokes polarimeter where the HWP follows a precessional motion with an angle $θ_0$. We show the result depending on the HWP inertia tensor, spinning speed and on $θ_0$. The result of numerical simulations is reported as a simple timeline of the electric fields. Finally, assuming to observe all the sky with a satellite mission, we analyze the effect on B-modes measurements. The effect is not negligible giving the current B-modes experiments sensitivity, therefore it is a systematic which needs to be carefully considered for future experiments.
△ Less
Submitted 17 June, 2019;
originally announced June 2019.
-
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric Interferometer
Authors:
Aniello Mennella,
Peter Ade,
Giorgio Amico,
Didier Auguste,
Jonathan Aumont,
Stefano Banfi,
Gustavo Barbaràn,
Paola Battaglia,
Elia Battistelli,
Alessandro Baù,
Benoit Bélier,
David G. Bennett,
Laurent Bergé,
Jean Philippe Bernard,
Marco Bersanelli,
Marie Anne Bigot Sazy,
Nathat Bleurvacq,
Juan Bonaparte,
Julien Bonis,
Emory F. Bunn,
David Burke,
Daniele Buzi,
Alessandro Buzzelli,
Francesco Cavaliere,
Pierre Chanial
, et al. (105 additional authors not shown)
Abstract:
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its…
▽ More
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e. the ability to separate the signal in various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.
△ Less
Submitted 23 January, 2019; v1 submitted 30 November, 2018;
originally announced December 2018.
-
Thermal architecture for the QUBIC cryogenic receiver
Authors:
A. J. May,
C. Chapron,
G. Coppi,
G. D'Alessandro,
P. de Bernardis,
S. Masi,
S. Melhuish,
M. Piat,
L. Piccirillo,
A. Schillaci,
J. -P. Thermeau,
P. Ade,
G. Amico,
D. Auguste,
J. Aumont,
S. Banfi,
G. Barbara,
P. Battaglia,
E. Battistelli,
A. Bau,
B. Belier,
D. Bennett,
L. Berge,
J. -Ph. Bernard,
M. Bersanelli
, et al. (105 additional authors not shown)
Abstract:
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex opt…
▽ More
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
Authors:
A. Mennella,
P. A. R. Ade,
J. Aumont,
S. Banfi,
P. Battaglia,
E. S. Battistelli,
A. Baù,
B. Bélier,
D. Bennett,
L. Bergé,
J. Ph. Bernard,
M. Bersanelli,
M. A. Bigot-Sazy,
N. Bleurvacq,
G. Bordier,
J. Brossard,
E. F. Bunn,
D. P. Burke,
D. Buzi,
A. Buzzelli,
D. Cammilleri,
F. Cavaliere,
P. Chanial,
C. Chapron,
F. Columbro
, et al. (83 additional authors not shown)
Abstract:
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument…
▽ More
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.