Crosstalk effects in microwave SQUID multiplexed TES bolometer readout
Authors:
John C. Groh,
Zeeshan Ahmed,
Shawn W. Henderson,
Johannes Hubmayr,
John A. B. Mates,
Maximiliano Silva-Feaver,
Joel Ullom,
Cyndia Yu
Abstract:
Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband…
▽ More
Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.
△ Less
Submitted 8 April, 2024; v1 submitted 9 November, 2023;
originally announced November 2023.
-
Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier
Authors:
M. Malnou,
J. A. B. Mates,
M. R. Vissers,
L. R. Vale,
D. R. Schmidt,
D. A. Bennett,
J. Gao,
J. N. Ullom
Abstract:
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodi…
▽ More
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
ASCENT - A balloon-borne hard X-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors
Authors:
Fabian Kislat,
Daniel Becker,
Douglas Bennett,
Adrika Dasgupta,
Joseph Fowler,
Christopher L. Fryer,
Johnathon Gard,
Ephraim Gau,
Danielle Gurgew,
Keon Harmon,
Takayuki Hayashi,
Scott Heatwole,
Md Arman Hossen,
Henric Krawczynski,
R. James Lanzi,
Jason Legere,
John A. B. Mates,
Mark McConnell,
Johanna Nagy,
Takashi Okajima,
Toshiki Sato,
Daniel Schmidt,
Sean Spooner,
Daniel Swetz,
Keisuke Tamura
, et al. (4 additional authors not shown)
Abstract:
Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormou…
▽ More
Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. The isotope ${}^{44}$Ti is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard X-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called ASCENT (A SuperConducting ENergetic x-ray Telescope). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55 eV Full Width Half Maximum (FWHM) energy resolution at 97 keV. This 8--16-fold improvement in energy resolution over NuSTAR will allow high resolution imaging and spectroscopy of the ${}^{44}$Ti emission. This will allow a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as: What is the source of the neutron star "kicks"? What is the dominant production pathway for ${}^{44}$Ti? Is the engine of Cas A unique?
△ Less
Submitted 4 January, 2023;
originally announced January 2023.
-
Signal readout for Transition-Edge Sensor X-ray imaging spectrometers
Authors:
H. Akamatsu,
W. B. Doriese,
J. A. B. Mates,
B. D. Jackson
Abstract:
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/ΔE\urss{FWHM}$) of a few thousand across a broad energy range (200~eV to 10~keV or higher), would be a revolutionary instrument for the study of energetic astrophysical objects an…
▽ More
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/ΔE\urss{FWHM}$) of a few thousand across a broad energy range (200~eV to 10~keV or higher), would be a revolutionary instrument for the study of energetic astrophysical objects and phenomena. Signal readout is a critical enabling technology. Multiplexed readout, in which signals from multiple pixels are combined into a single amplifier channel, allows a kilo pixel-scale microcalorimeter array to meet the stringent requirements for power consumption, mass, volume, and cooling capacity in orbit. This chapter describes three different multiplexed-readout technologies for transition-edge-sensor microcalorimeters: time-division multiplexing, frequency-domain multiplexing, and microwave-SQUID multiplexing. For each multiplexing technique, we present the basic method, discuss some design considerations and parameters, and show the state of the art. The chapter concludes with a brief discussion of future prospects.
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Josef C. Frisch,
Shawn W. Henderson,
Max Silva-Feaver,
Kam Arnold,
David Brown,
Jake Connors,
Ari J. Cukierman,
J. Mitch D'Ewart,
Bradley J. Dober,
John E. Dusatko,
Gunther Haller,
Ryan Herbst,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Chao-Lin Kuo,
John A. B. Mates,
Larry Ruckman,
Joel Ullom,
Leila Vale,
Daniel D. Van Winkle,
Jesus Vasquez,
Edward Young
Abstract:
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arr…
▽ More
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. We focus in particular on the case of large channel count, low bandwidth applications, but the system has been easily reconfigured for high bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
△ Less
Submitted 22 August, 2022;
originally announced August 2022.
-
Bandwidth and Aliasing in the Microwave SQUID Multiplexer
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Jake A. Connors,
J. Mitch D'Ewart,
Bradley Dober,
Josef C. Frisch,
Shawn W. Henderson,
Gene C. Hilton,
Johannes Hubmayr,
Stephen E. Kuenstner,
J. A. Ben Mates,
Maximiliano Silva-Feaver,
Joel N. Ullom,
Leila R. Vale,
Dan Van Winkle,
Edward Young
Abstract:
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts.…
▽ More
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of umux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. We present simulations and measurements of umux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Observations of compact sources in galaxy clusters using MUSTANG2
Authors:
Simon R. Dicker,
Elia S. Battistelli,
Tanay Bhandarkar,
Mark J. Devlin,
Shannon M. Duff,
Gene Hilton,
Matt Hilton,
Adam D. Hincks,
Johannes Hubmayr,
Kevin Huffenberger,
John P. Hughes,
Luca Di Mascolo,
Brian S. Mason,
J. A. B. Mates,
Jeff McMahon,
Tony Mroczkowski,
Sigurd Naess,
John Orlowski-Scherer,
Bruce Partridge,
Federico Radiconi,
Charles Romero,
Craig L. Sarazin,
Neelima Sehgal,
Jonathan Sievers,
Cristóbal Sifón
, et al. (4 additional authors not shown)
Abstract:
Compact sources can cause scatter in the scaling relationships between the amplitude of the thermal Sunyaev-Zel'dovich Effect (tSZE) in galaxy clusters and cluster mass. Estimates of the importance of this scatter vary - largely due to limited data on sources in clusters at the frequencies at which tSZE cluster surveys operate. In this paper we present 90 GHz compact source measurements from a sam…
▽ More
Compact sources can cause scatter in the scaling relationships between the amplitude of the thermal Sunyaev-Zel'dovich Effect (tSZE) in galaxy clusters and cluster mass. Estimates of the importance of this scatter vary - largely due to limited data on sources in clusters at the frequencies at which tSZE cluster surveys operate. In this paper we present 90 GHz compact source measurements from a sample of 30 clusters observed using the MUSTANG2 instrument on the Green Bank Telescope. We present simulations of how a source's flux density, spectral index, and angular separation from the cluster's center affect the measured tSZE in clusters detected by the Atacama Cosmology Telescope (ACT). By comparing the MUSTANG2 measurements with these simulations we calibrate an empirical relationship between 1.4 GHz flux densities from radio surveys and source contamination in ACT tSZE measurements. We find 3 per cent of the ACT clusters have more than a 20 per cent decrease in Compton-y but another 3 per cent have a 10 per cent increase in the Compton-y due to the matched filters used to find clusters. As sources affect the measured tSZE signal and hence the likelihood that a cluster will be detected, testing the level of source contamination in the tSZE signal using a tSZE selected catalog is inherently biased. We confirm this by comparing the ACT tSZE catalog with optically and X-ray selected cluster catalogs. There is a strong case for a large, high resolution survey of clusters to better characterize their source population.
△ Less
Submitted 22 September, 2021; v1 submitted 14 July, 2021;
originally announced July 2021.
-
The Simons Observatory microwave SQUID multiplexing detector module design
Authors:
Heather McCarrick,
Erin Healy,
Zeeshan Ahmed,
Kam Arnold,
Zachary Atkins,
Jason E. Austermann,
Tanay Bhandarkar,
Jim A. Beall,
Sarah Marie Bruno,
Steve K. Choi,
Jake Connors,
Nicholas F. Cothard,
Kevin D. Crowley,
Simon Dicker,
Bradley Dober,
Cody J. Duell,
Shannon M. Duff,
Daniel Dutcher,
Josef C. Frisch,
Nicholas Galitzki,
Megan B. Gralla,
Jon E. Gudmundsson,
Shawn W. Henderson,
Gene C. Hilton,
Shuay-Pwu Patty Ho
, et al. (34 additional authors not shown)
Abstract:
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of…
▽ More
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing ($μ$mux). Simons Observatory will use 49 modules containing 60,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a $95\%$ yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 $\mathrm{pA/\sqrt{Hz}}$. This impacts the projected SO mapping speed by $< 8\%$, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.
△ Less
Submitted 16 September, 2021; v1 submitted 28 June, 2021;
originally announced June 2021.
-
The design of the Ali CMB Polarization Telescope receiver
Authors:
Maria Salatino,
Jason E. Austermann,
Keith L. Thompson,
Peter A. R. Ade,
Xiran Bai,
James A. Beall,
Dan T. Becker,
Yifu Cai,
Zhi Chang,
Ding Chen,
Pisin Chen,
Jake Connors,
Jacques Delabrouille,
Bradley Dober,
Shannon M. Duff,
Guanhua Gao,
Shamik Ghosh,
Richard C. Givhan,
Gene C. Hilton,
Bin Hu,
Johannes Hubmayr,
Ethan D. Karpel,
Chao-Lin Kuo,
Hong Li,
Mingzhe Li
, et al. (50 additional authors not shown)
Abstract:
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polariza…
▽ More
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.
△ Less
Submitted 23 January, 2021;
originally announced January 2021.
-
A Microwave SQUID Multiplexer Optimized for Bolometric Applications
Authors:
B. Dober,
Z. Ahmed,
K. Arnold,
D. T. Becker,
D. A. Bennett,
J. A. Connors,
A. Cukierman,
J. M. D'Ewart,
S. M. Duff,
J. E. Dusatko,
J. C. Frisch,
J. D. Gard,
S. W. Henderson,
R. Herbst,
G. C. Hilton,
J. Hubmayr,
Y. Li,
J. A. B. Mates,
H. McCarrick,
C. D Reintsema,
M. Silva-Feaver,
L. Ruckman,
J. N. Ullom,
L. R. Vale,
D. D. Van Winkle
, et al. (5 additional authors not shown)
Abstract:
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4…
▽ More
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.
△ Less
Submitted 19 January, 2021; v1 submitted 15 October, 2020;
originally announced October 2020.
-
Microwave multiplexing on the Keck Array
Authors:
Ari Cukierman,
Zeeshan Ahmed,
Shawn Henderson,
Edward Young,
Cyndia Yu,
Denis Barkats,
David Brown,
Saptarshi Chaudhuri,
James Cornelison,
John M. D'Ewart,
Marion Dierickx,
Bradley J. Dober,
John Dusatko,
Sofia Fatigoni,
Jeff P. Filippini,
Josef C. Frisch,
Gunther Haller,
Mark Halpern,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Kirit S. Karkare,
Ethan Karpel,
Sarah A. Kernasovskiy,
John M. Kovac
, et al. (60 additional authors not shown)
Abstract:
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled…
▽ More
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio-frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5-6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.
△ Less
Submitted 17 January, 2020; v1 submitted 3 September, 2019;
originally announced September 2019.
-
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Authors:
Shawn W. Henderson,
Zeeshan Ahmed,
Jason Austermann,
Daniel Becker,
Douglas A. Bennett,
David Brown,
Saptarshi Chaudhuri,
Hsiao-Mei Sherry Cho,
John M. D'Ewart,
Bradley Dober,
Shannon M. Duff,
John E. Dusatko,
Sofia Fatigoni,
Josef C. Frisch,
Jonathon D. Gard,
Mark Halpern,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Ethan D. Karpel,
Sarah S. Kernasovskiy,
Stephen E. Kuenstner,
Chao-Lin Kuo,
Dale Li,
John A. B. Mates
, et al. (7 additional authors not shown)
Abstract:
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per se…
▽ More
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers ($\sim$10,000--100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to read out each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for several future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. Parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.
△ Less
Submitted 11 September, 2018;
originally announced September 2018.
-
SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors
Authors:
S. A. Kernasovskiy,
S. E. Kuenstner,
E. Karpel,
Z. Ahmed,
D. D. Van Winkle,
S. Smith,
J. Dusatko,
J. C. Frisch,
S. Chaudhuri,
H. M. Cho,
B. J. Dober,
S. W. Henderson,
G. C. Hilton,
J. Hubmayr,
K. D. Irwin,
C. L. Kuo,
D. Li,
J. A. B. Mates,
M. Nasr,
S. Tantawi,
J. Ullom,
L. Vale,
B. Young
Abstract:
Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detecto…
▽ More
Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detectors (MKIDs). In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator's excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at $\sim$6 MHz with center frequencies $\sim$5-6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.
△ Less
Submitted 21 May, 2018;
originally announced May 2018.
-
Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers
Authors:
B. Dober,
D. T. Becker,
D. A. Bennett,
S. A. Bryan,
S. M. Duff,
J. D. Gard,
J. P. Hays-Wehle,
G. C. Hilton,
J. Hubmayr,
J. A. B. Mates,
C. D. Reintsema,
L. R. Vale,
J. N. Ullom
Abstract:
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, wh…
▽ More
Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($μ$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $μ$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $μ$MUX as a viable readout technique for future CMB imaging instruments.
△ Less
Submitted 15 December, 2017; v1 submitted 11 October, 2017;
originally announced October 2017.
-
High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array
Authors:
Omid Noroozian,
John A. B. Mates,
Douglas A. Bennett,
Justus A. Brevik,
Joseph W. Fowler,
Jiansong Gao,
Gene C. Hilton,
Robert D. Horansky,
Kent D. Irwin,
Zhao Kang,
Daniel R. Schmidt,
Leila R. Vale,
Joel N. Ullom
Abstract:
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators co…
▽ More
We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a $^{153}$Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/$\sqrt{\text{Hz}}$ at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices (SQUID) and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than $10^3$ elements and spectral resolving powers $R=λ/Δλ> 10^3$.
△ Less
Submitted 27 October, 2013;
originally announced October 2013.
-
Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields
Authors:
G. M. Stiehl,
H. M. Cho,
G. C. Hilton,
K. D. Irwin,
J. A. B. Mates,
C. D. Reintsema,
B. L. Zink
Abstract:
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs.…
▽ More
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs. These designs include a new variety with improved gradiometry that significantly reduces the effective area of both the first and second stage SQUID amplifiers.
△ Less
Submitted 30 August, 2010;
originally announced August 2010.