Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and Some Preliminary Results from its performance in the orbit
Authors:
P. C. Agrawal,
J. S. Yadav,
H. M. Antia,
Dhiraj Dedhia,
P. Shah,
Jai Verdhan Chauhan,
R. K. Manchanda,
V. R. Chitnis,
V. M. Gujar,
Tilak Katoch,
V. N. Kurhade,
P. Madhwani,
T. K. Manojkumar,
V. A. Nikam,
A. S. Pandya,
J. V. Parmar,
D. M. Pawar,
Jayashree Roy,
B. Paul,
Mayukh Pahari,
Ranjeev Misra,
M. H. Ravichandran,
K. Anilkumar,
C. C. Joseph,
K. H. Navalgund
, et al. (3 additional authors not shown)
Abstract:
Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC d…
▽ More
Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. In this article, we present salient features of the LAXPC detectors, their testing and characterization in the laboratory prior to launch and calibration in the orbit. Some preliminary results on timing and spectral characteristics of a few X-ray binaries and other type of sources, are briefly discussed to demonstrate that the LAXPC instrument is performing as planned in the orbit.
△ Less
Submitted 25 May, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
Calibration of the Large Area X-ray Proportional Counter (LAXPC) instrument on-board AstroSat
Authors:
H. M. Antia,
J. S. Yadav,
P. C. Agrawal,
Jai Verdhan Chauhan,
R. K. Manchanda,
Varsha Chitnis,
Biswajit Paul,
Dhiraj Dedhia,
Parag Shah,
V. M. Gujar,
Tilak Katoch,
V. N. Kurhade,
Pankaj Madhwani,
T. K. Manojkumar,
V. A. Nikam,
A. S. Pandya,
J. V. Parmar,
D. M. Pawar,
Mayukh Pahari,
Ranjeev Misra,
K. H. Navalgund,
R. Pandiyan,
K. S. Sharma,
K. Subbarao
Abstract:
We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on-board AstroSat. LAXPC instrument has three nominally identical detectors to achieve large collecting area. These detectors are independent of each other and in the event analysis mode, they record the arrival time and energy of each photon that is detected. The detectors have a time-r…
▽ More
We present the calibration and background model for the Large Area X-ray Proportional Counter (LAXPC) detectors on-board AstroSat. LAXPC instrument has three nominally identical detectors to achieve large collecting area. These detectors are independent of each other and in the event analysis mode, they record the arrival time and energy of each photon that is detected. The detectors have a time-resolution of 10 $μ$s and a dead-time of about 42 $μ$s. This makes LAXPC ideal for timing studies. The energy resolution and peak channel to energy mapping were obtained from calibration on ground using radioactive sources coupled with GEANT4 simulations of the detectors. The response matrix was further refined from observations of the Crab X-ray source after launch. At around 20 keV the energy resolution of detector is about 10--15\%, while the combined effective area of the 3 detectors is about 6000 cm$^2$.
△ Less
Submitted 18 June, 2017; v1 submitted 27 February, 2017;
originally announced February 2017.