Measuring the CMB spectral distortions with COSMO: the multi-mode antenna system
Authors:
E. Manzan,
L. Albano,
C. Franceschet,
E. S. Battistelli,
P. de Bernardis,
M. Bersanelli,
F. Cacciotti,
A. Capponi,
F. Columbro,
G. Conenna,
G. Coppi,
A. Coppolecchia,
G. D'Alessandro,
G. De Gasperis,
M. De Petris,
M. Gervasi,
G. Isopi,
L. Lamagna,
A. Limonta,
E. Marchitelli,
S. Masi,
A. Mennella,
F. Montonati,
F. Nati,
A. Occhiuzzi
, et al. (7 additional authors not shown)
Abstract:
In this work, we present the design and manufacturing of the two multi-mode antenna arrays of the COSMO experiment and the preliminary beam pattern measurements of their fundamental mode compared with simulations.
COSMO is a cryogenic Martin-Puplett Fourier Transform Spectrometer that aims at measuring the isotropic y-type spectral distortion of the Cosmic Microwave Background from Antarctica, b…
▽ More
In this work, we present the design and manufacturing of the two multi-mode antenna arrays of the COSMO experiment and the preliminary beam pattern measurements of their fundamental mode compared with simulations.
COSMO is a cryogenic Martin-Puplett Fourier Transform Spectrometer that aims at measuring the isotropic y-type spectral distortion of the Cosmic Microwave Background from Antarctica, by performing differential measurements between the sky and an internal, cryogenic reference blackbody. To reduce the atmospheric contribution, a spinning wedge mirror performs fast sky-dips at varying elevations while fast, low-noise Kinetic Inductance detectors scan the interferogram.
Two arrays of antennas couple the radiation to the detectors. Each array consists of nine smooth-walled multi-mode feed-horns, operating in the $120-180$ GHz and $210-300$ GHz range, respectively. The multi-mode propagation helps increase the instrumental sensitivity without employing large focal planes with hundreds of detectors. The two arrays have a step-linear and a linear profile, respectively, and are obtained by superimposing aluminum plates made with CNC milling. The simulated multi-mode beam pattern has a $\sim 20^{\circ} - 26^{\circ}$ FWHM for the low-frequency array and $\sim 16^{\circ}$ FWHM for the high-frequency one. The side lobes are below $-15$ dB.
To characterize the antenna response, we measured the beam pattern of the fundamental mode using a Vector Network Analyzer, in far-field conditions inside an anechoic chamber at room temperature. We completed the measurements of the low-frequency array and found a good agreement with the simulations. We also identified a few non-idealities that we attribute to the measuring setup and will further investigate. A comprehensive multi-mode measurement will be feasible at cryogenic temperature once the full receiver is integrated.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
-
Total power horn-coupled 150 GHz LEKID array for space applications
Authors:
A. Paiella,
A. Coppolecchia,
P. de Bernardis,
S. Masi,
A. Cruciani,
L. Lamagna,
G. Pettinari,
F. Piacentini,
M. Bersanelli,
F. Cavaliere,
C. Franceschet,
M. Gervasi,
A. Limonta,
S. Mandelli,
E. Manzan,
A. Mennella,
A. Passerini,
E. Tommasi,
A. Volpe,
M. Zannoni
Abstract:
We have developed two arrays of lumped element kinetic inductance detectors working in the D-band, and optimised for the low radiative background conditions of a satellite mission aiming at precision measurements of the Cosmic Microwave Background (CMB). The first detector array is sensitive to the total power of the incoming radiation to which is coupled via single-mode waveguides and corrugated…
▽ More
We have developed two arrays of lumped element kinetic inductance detectors working in the D-band, and optimised for the low radiative background conditions of a satellite mission aiming at precision measurements of the Cosmic Microwave Background (CMB). The first detector array is sensitive to the total power of the incoming radiation to which is coupled via single-mode waveguides and corrugated feed-horns, while the second is sensitive to the polarisation of the radiation thanks to orthomode transducers. Here, we focus on the total power detector array, which is suitable, for instance, for precision measurements of unpolarised spectral distortions of the CMB, where detecting both polarisations provides a sensitivity advantage. We describe the optimisation of the array design, fabrication and packaging, the dark and optical characterisation, and the performance of the black-body calibrator used for the optical tests. We show that almost all the detectors of the array are photon-noise limited under the radiative background of a 3.6 K black-body. This result, combined with the weak sensitivity to cosmic rays hits demonstrated with the OLIMPO flight, validates the idea of using lumped elements kinetic inductance detectors for precision, space-based CMB missions.
△ Less
Submitted 10 June, 2022; v1 submitted 16 November, 2021;
originally announced November 2021.
-
The COSmic Monopole Observer (COSMO)
Authors:
S. Masi,
E. Battistelli,
P. de Bernardis,
A. Coppolecchia,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Lamagna,
E. Marchitelli,
L. Mele,
A. Paiella,
F. Piacentini,
G. Pisano,
M. Bersanelli,
C. Franceschet,
E. Manzan,
D. Mennella,
S. Realini,
S. Cibella,
F. Martini,
G. Pettinari,
G. Coppi,
M. Gervasi,
A. Limonta,
M. Zannoni
, et al. (2 additional authors not shown)
Abstract:
The COSmic Monopole Observer (COSMO) is an experiment to measure low-level spectral distortions in the isotropic component of the Cosmic Microwave Background (CMB). Deviations from a pure blackbody spectrum are expected at low level ($<$ 1 ppm) due to several astrophysical and cosmological phenomena, and promise to provide important independent information on the early and late phases of the unive…
▽ More
The COSmic Monopole Observer (COSMO) is an experiment to measure low-level spectral distortions in the isotropic component of the Cosmic Microwave Background (CMB). Deviations from a pure blackbody spectrum are expected at low level ($<$ 1 ppm) due to several astrophysical and cosmological phenomena, and promise to provide important independent information on the early and late phases of the universe. They have not been detected yet, due to the extreme accuracy required, the best upper limits being still those from the COBE-FIRAS mission. COSMO is based on a cryogenic differential Fourier Transform Spectrometer, measuring the spectral brightness difference between the sky and an accurate cryogenic blackbody. The first implementation of COSMO, funded by the Italian PRIN and PNRA programs, will operate from the Concordia station at Dome-C, in Antarctica, and will take advantage of a fast sky-dip technique to get rid of atmospheric emission and its fluctuations, separating them from the monopole component of the sky brightness. Here we describe the instrument design, its capabilities, the current status. We also discuss its subsequent implementation in a balloon-flight, which has been studied within the COSMOS program of the Italian Space Agency.
△ Less
Submitted 23 October, 2021;
originally announced October 2021.
-
A chemically etched corrugated feedhorn array for D-band CMB observations
Authors:
Stefano Mandelli,
Elenia Manzan,
Aniello Mennella,
Francesco Cavaliere,
Daniele Viganò,
Cristian Franceschet,
Paolo de Bernardis,
Marco Bersanelli,
Maria Gabriella Castellano,
Alessandro Coppolecchia,
Angelo Cruciani,
Massimo Gervasi,
Luca Lamagna,
Andrea Limonta,
Silvia Masi,
Alessandro Paiella,
Andrea Passerini,
Giorgio Pettinari,
Francesco Piacentini,
Elisabetta Tommasi,
Angela Volpe,
Mario Zannoni
Abstract:
We present the design, manufacturing, and testing of a 37-element array of corrugated feedhorns for Cosmic Microwave Background (CMB) measurements between $140$ and $170$ GHz. The array was designed to be coupled to Kinetic Inductance Detector arrays, either directly (for total power measurements) or through an orthomode transducer (for polarization measurements). We manufactured the array in plat…
▽ More
We present the design, manufacturing, and testing of a 37-element array of corrugated feedhorns for Cosmic Microwave Background (CMB) measurements between $140$ and $170$ GHz. The array was designed to be coupled to Kinetic Inductance Detector arrays, either directly (for total power measurements) or through an orthomode transducer (for polarization measurements). We manufactured the array in platelets by chemically etching aluminum plates of $0.3$ mm and $0.4$ mm thickness. The process is fast, low-cost, scalable, and yields high-performance antennas compared to other techniques in the same frequency range. Room temperature electromagnetic measurements show excellent repeatability with an average cross polarization level about $-20$ dB, return loss about $-25$ dB, first sidelobes below $-25$ dB and far sidelobes below $-35$ dB. Our results qualify this process as a valid candidate for state-of-the-art CMB experiments, where large detector arrays with high sensitivity and polarization purity are of paramount importance in the quest for the discovery of CMB polarization $B$-modes.
△ Less
Submitted 21 October, 2020; v1 submitted 26 June, 2020;
originally announced June 2020.