-
Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi
, et al. (38 additional authors not shown)
Abstract:
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is…
▽ More
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Initial operations of the Soft X-ray Imager onboard XRISM
Authors:
Hiromasa Suzuki,
Tomokage Yoneyama,
Shogo B. Kobayashi,
Hirofumi Noda,
Hiroyuki Uchida,
Kumiko K. Nobukawa,
Kouichi Hagino,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Yoshiaki Kanemaru,
Yoshinori Otsuka,
Haruhiko Yokosu,
Wakana Yonemaru,
Hanako Nakano,
Kazuhiro Ichikawa,
Reo Takemoto,
Tsukasa Matsushima,
Marina Yoshimoto,
Mio Aoyagi,
Kohei Shima
, et al. (30 additional authors not shown)
Abstract:
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. The Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The components of SXI include CCDs, analog and digital electr…
▽ More
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. The Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The components of SXI include CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C ~after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and operations for protection against South Atlantic Anomaly. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the specific modes with higher timing resolutions, and event selection algorithm. We summarize our policy and procedure of the initial operations for SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Evaluation of the X-ray SOI pixel detector with the on-chip ADC
Authors:
Hiroumi Matsuhashi,
Kouichi Hagino,
Aya Bamba,
Ayaki Takeda,
Masataka Yukumoto,
Koji Mori,
Yusuke Nishioka,
Takeshi Go Tsuru,
Mizuki Uenomachi,
Tomonori Ikeda,
Masamune Matsuda,
Takuto Narita,
Hiromasa Suzuki,
Takaaki Tanaka,
Ikuo Kurachi,
Takayoshi Kohmura,
Yusuke Uchida,
Yasuo Arai,
Shoji Kawahito
Abstract:
XRPIX is the monolithic X-ray SOI (silicon-on-insulator) pixel detector, which has a time resolution better than 10 $\rmμ$s as well as a high detection efficiency for X-rays above 10 keV. XRPIX is planned to be installed on future X-ray satellites. To mount on satellites, it is essential that the ADC (analog-to-digital converter) be implemented on the detector because such peripheral circuits must…
▽ More
XRPIX is the monolithic X-ray SOI (silicon-on-insulator) pixel detector, which has a time resolution better than 10 $\rmμ$s as well as a high detection efficiency for X-rays above 10 keV. XRPIX is planned to be installed on future X-ray satellites. To mount on satellites, it is essential that the ADC (analog-to-digital converter) be implemented on the detector because such peripheral circuits must be as compact as possible to achieve a large imaging area in the limited space in satellites. Thus, we developed a new XRPIX device with the on-chip ADC, and evaluated its performances. As the results, the integral non-linearity was evaluated to be 6 LSB (least significant bit), equivalent to 36 eV. The differential non-linearity was less than 0.7 LSB, and input noise from the on-chip ADC was 5~$\rm{e^{-}}$. Also, we evaluated end-to-end performance including the sensor part as well as the on-chip ADC. As the results, energy resolution at 5.9 keV was 294 $\rm{\pm}$ 4 eV in full-width at half maximum for the best pixel.
△ Less
Submitted 10 May, 2024; v1 submitted 9 May, 2024;
originally announced May 2024.
-
Design study and spectroscopic performance of SOI pixel detector with a pinned depleted diode structure for X-ray astronomy
Authors:
Masataka Yukumoto,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Syuto Yonemura,
Daisuke Izumi,
Uzuki Iwakiri,
Takeshi G. Tsuru,
Ikuo Kurachi,
Kouichi Hagino,
Yasuo Arai,
Takayoshi Kohmura,
Takaaki Tanaka,
Miraku Kimura,
Yuta Fuchita,
Taiga Yoshida,
Tomonori Ikeda
Abstract:
We have been developing silicon-on-insulator (SOI) pixel detectors with a pinned depleted diode (PDD) structure, named "XRPIX", for X-ray astronomy. The PDD structure is formed in a thick p-type substrate, to which high negative voltage is applied to make it fully depleted. A pinned p-well is introduced at the backside of the insulator layer to reduce a dark current generation at the Si-SiO$_{2}$…
▽ More
We have been developing silicon-on-insulator (SOI) pixel detectors with a pinned depleted diode (PDD) structure, named "XRPIX", for X-ray astronomy. The PDD structure is formed in a thick p-type substrate, to which high negative voltage is applied to make it fully depleted. A pinned p-well is introduced at the backside of the insulator layer to reduce a dark current generation at the Si-SiO$_{2}$ interface and to fix the back-gate voltage of the SOI transistors. An n-well is further introduced between the p-well and the substrate to make a potential barrier between them and suppress a leakage current. An optimization study on the n-well dopant concentration is necessary because a higher dopant concentration could result in a higher potential barrier but also in a larger sense-node capacitance leading to a lower spectroscopic performance, and vice versa. Based on a device simulation, we fabricated five candidate chips having different n-well dopant concentrations. We successfully found out the best n-well design, which suppressed a large leakage current and showed satisfactory X-ray spectroscopic performance. Too low and too high n-well dopant concentration chips showed a large leakage current and degraded X-ray spectroscopic performance, respectively. We also found that the dependency of X-ray spectroscopic performance on the n-well dopant concentration can be largely explained by the difference in sense-node capacitance.
△ Less
Submitted 9 January, 2024;
originally announced January 2024.
-
Radiation-Induced Degradation Mechanism of X-ray SOI Pixel Sensors with Pinned Depleted Diode Structure
Authors:
Kouichi Hagino,
Masatoshi Kitajima,
Takayoshi Kohmura,
Ikuo Kurachi,
Takeshi G. Tsuru,
Masataka Yukumoto,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Takaaki Tanaka
Abstract:
The X-ray Silicon-On-Insulator (SOI) pixel sensor named XRPIX has been developed for the future X-ray astronomical satellite FORCE. XRPIX is capable of a wide-band X-ray imaging spectroscopy from below 1 keV to a few tens of keV with a good timing resolution of a few tens of $μ$s. However, it had a major issue with its radiation tolerance to the total ionizing dose (TID) effect because of its thic…
▽ More
The X-ray Silicon-On-Insulator (SOI) pixel sensor named XRPIX has been developed for the future X-ray astronomical satellite FORCE. XRPIX is capable of a wide-band X-ray imaging spectroscopy from below 1 keV to a few tens of keV with a good timing resolution of a few tens of $μ$s. However, it had a major issue with its radiation tolerance to the total ionizing dose (TID) effect because of its thick buried oxide layer due to the SOI structure. Although new device structures introducing pinned depleted diodes dramatically improved radiation tolerance, it remained unknown how radiation effects degrade the sensor performance. Thus, this paper reports the results of a study of the degradation mechanism of XRPIX due to radiation using device simulations. In particular, mechanisms of increases in dark current and readout noise are investigated by simulation, taking into account the positive charge accumulation in the oxide layer and the increase in the surface recombination velocity at the interface between the sensor layer and the oxide layer. As a result, it is found that the depletion of the buried p-well at the interface increases the dark current, and that the increase in the sense-node capacitance increases the readout noise.
△ Less
Submitted 14 June, 2023;
originally announced June 2023.
-
A broadband X-ray imaging spectroscopy in the 2030s: the FORCE mission
Authors:
Koji Mori,
Takeshi G. Tsuru,
Kazuhiro Nakazawa,
Yoshihiro Ueda,
Shin Watanabe,
Takaaki Tanaka,
Manabu Ishida,
Hironori Matsumoto,
Hisamitsu Awaki,
Hiroshi Murakami,
Masayoshi Nobukawa,
Ayaki Takeda,
Yasushi Fukazawa,
Hiroshi Tsunemi,
Tadayuki Takahashi,
Ann Hornschemeier,
Takashi Okajima,
William W. Zhang,
Brian J. Williams,
Tonia Venters,
Kristin Madsen,
Mihoko Yukita,
Hiroki Akamatsu,
Aya Bamba,
Teruaki Enoto
, et al. (27 additional authors not shown)
Abstract:
In this multi-messenger astronomy era, all the observational probes are improving their sensitivities and overall performance. The Focusing on Relativistic universe and Cosmic Evolution (FORCE) mission, the product of a JAXA/NASA collaboration, will reach a 10 times higher sensitivity in the hard X-ray band ($E >$ 10~keV) in comparison with any previous hard X-ray missions, and provide simultaneou…
▽ More
In this multi-messenger astronomy era, all the observational probes are improving their sensitivities and overall performance. The Focusing on Relativistic universe and Cosmic Evolution (FORCE) mission, the product of a JAXA/NASA collaboration, will reach a 10 times higher sensitivity in the hard X-ray band ($E >$ 10~keV) in comparison with any previous hard X-ray missions, and provide simultaneous soft X-ray coverage. FORCE aims to be launched in the early 2030s, providing a perfect hard X-ray complement to the ESA flagship mission Athena. FORCE will be the most powerful X-ray probe for discovering obscured/hidden black holes and studying high energy particle acceleration in our Universe and will address how relativistic processes in the universe are realized and how these affect cosmic evolution. FORCE, which will operate over 1--79 keV, is equipped with two identical pairs of supermirrors and wideband X-ray imagers. The mirror and imager are connected by a high mechanical stiffness extensible optical bench with alignment monitor systems with a focal length of 12~m. A light-weight silicon mirror with multi-layer coating realizes a high angular resolution of $<15''$ in half-power diameter in the broad bandpass. The imager is a hybrid of a brand-new SOI-CMOS silicon-pixel detector and a CdTe detector responsible for the softer and harder energy bands, respectively. FORCE will play an essential role in the multi-messenger astronomy in the 2030s with its broadband X-ray sensitivity.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroyuki Uchida,
Kouichi Hagino,
Shogo Benjamin Kobayashi,
Hiromasa Suzuki,
Tessei Yoshida,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Kumiko Nobukawa,
Tomokage Yoneyama,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi,
Keisuke Tamura,
Rozenn Boissay-Malaquin
, et al. (30 additional authors not shown)
Abstract:
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an…
▽ More
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
Single Event Tolerance of X-ray SOI Pixel Sensors
Authors:
Kouichi Hagino,
Mitsuki Hayashida,
Takayoshi Kohmura,
Toshiki Doi,
Shun Tsunomachi,
Masatoshi Kitajima,
Takeshi G. Tsuru,
Hiroyuki Uchida,
Kazuho Kayama,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Masataka Yukumoto,
Kira Mieda,
Syuto Yonemura,
Tatsunori Ishida,
Takaaki Tanaka,
Yasuo Arai,
Ikuo Kurachi,
Hisashi Kitamura,
Shoji Kawahito,
Keita Yasutomi
Abstract:
We evaluate the single event tolerance of the X-ray silicon-on-insulator (SOI) pixel sensor named XRPIX, developed for the future X-ray astronomical satellite FORCE. In this work, we measure the cross-section of single event upset (SEU) of the shift register on XRPIX by irradiating heavy ion beams with linear energy transfer (LET) ranging from 0.022 MeV/(mg/cm2) to 68 MeV/(mg/cm2). From the SEU cr…
▽ More
We evaluate the single event tolerance of the X-ray silicon-on-insulator (SOI) pixel sensor named XRPIX, developed for the future X-ray astronomical satellite FORCE. In this work, we measure the cross-section of single event upset (SEU) of the shift register on XRPIX by irradiating heavy ion beams with linear energy transfer (LET) ranging from 0.022 MeV/(mg/cm2) to 68 MeV/(mg/cm2). From the SEU cross-section curve, the saturation cross-section and threshold LET are successfully obtained to be $3.4^{+2.9}_{-0.9}\times 10^{-10}~{\rm cm^2/bit}$ and $7.3^{+1.9}_{-3.5}~{\rm MeV/(mg/cm^2)}$, respectively. Using these values, the SEU rate in orbit is estimated to be $\lesssim$ 0.1 event/year primarily due to the secondary particles induced by cosmic-ray protons. This SEU rate of the shift register on XRPIX is negligible in the FORCE orbit.
△ Less
Submitted 10 October, 2022;
originally announced October 2022.
-
Proton radiation damage tolerance of wide dynamic range SOI pixel detectors
Authors:
Shun Tsunomachi,
Takayoshi Kohmura,
Kouichi Hagino,
Masatoshi Kitajima,
Toshiki Doi,
Daiki Aoki,
Asuka Ohira,
Yasuyuki Shimizu,
Kaito Fujisawa,
Shizusa Yamazaki,
Yuusuke Uchida,
Makoto Shimizu,
Naoki Itoh,
Yasuo Arai,
Toshinobu Miyoshi,
Ryutaro Nishimura,
Takeshi Go Tsuru,
Ikuo Kurachi
Abstract:
We have been developing the SOI pixel detector ``INTPIX'' for space use and general purpose applications such as the residual stress measurement of a rail and high energy physics experiments. INTPIX is a monolithic pixel detector composed of a high-resistivity Si sensor, a SiO2 insulator, and CMOS pixel circuits utilizing Silicon-On-Insulator (SOI) technology. We have considered the possibility of…
▽ More
We have been developing the SOI pixel detector ``INTPIX'' for space use and general purpose applications such as the residual stress measurement of a rail and high energy physics experiments. INTPIX is a monolithic pixel detector composed of a high-resistivity Si sensor, a SiO2 insulator, and CMOS pixel circuits utilizing Silicon-On-Insulator (SOI) technology. We have considered the possibility of using INTPIX to observe X-ray polarization in space. When the semiconductor detector is used in space, it is subject to radiation damage resulting from high-energy protons. Therefore, it is necessary to investigate whether INTPIX has high radiation tolerance for use in space. The INTPIX8 was irradiated with 6 MeV protons up to a total dose of 2 krad at HIMAC, National Institute of Quantum Science in Japan, and evaluated the degradation of the performance, such as energy resolution and non-uniformity of gain and readout noise between pixels. After 500 rad irradiation, which is the typical lifetime of an X-ray astronomy satellite, the degradation of energy resolution at 14.4 keV is less than 10%, and the non-uniformity of readout noise and gain between pixels is constant within 0.1%.
△ Less
Submitted 8 September, 2022;
originally announced September 2022.
-
X-ray Radiation Damage Effects on Double-SOI Pixel Detectors for the Future Astronomical Satellite "FORCE"
Authors:
Masatoshi Kitajima,
Kouichi Hagino,
Takayoshi Kohmura,
Mitsuki Hayashida,
Kenji Oono,
Kousuke Negishi,
Keigo Yarita,
Toshiki Doi,
Shun Tsunomachi,
Takeshi G. Tsuru,
Hiroyuki Uchida,
Kazuho Kayama,
Ryota Kodama,
Takaaki Tanaka,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Masataka Yukumoto,
Kira Mieda,
Syuto Yonemura,
Tatsunori Ishida,
Yasuo Arai,
Ikuo Kurachi
Abstract:
We have been developing the monolithic active pixel detector "XRPIX" onboard the future X-ray astronomical satellite "FORCE". XRPIX is composed of CMOS pixel circuits, SiO2 insulator, and Si sensor by utilizing the silicon-on-insulator (SOI) technology. When the semiconductor detector is operated in orbit, it suffers from radiation damage due to X-rays emitted from the celestial objects as well as…
▽ More
We have been developing the monolithic active pixel detector "XRPIX" onboard the future X-ray astronomical satellite "FORCE". XRPIX is composed of CMOS pixel circuits, SiO2 insulator, and Si sensor by utilizing the silicon-on-insulator (SOI) technology. When the semiconductor detector is operated in orbit, it suffers from radiation damage due to X-rays emitted from the celestial objects as well as cosmic rays. From previous studies, positive charges trapped in the SiO2 insulator are known to cause the degradation of the detector performance. To improve the radiation hardness, we developed XRPIX equipped with Double-SOI (D-SOI) structure, introducing an additional silicon layer in the SiO2 insulator. This structure is aimed at compensating for the effect of the trapped positive charges. Although the radiation hardness to cosmic rays of the D-SOI detectors has been evaluated, the radiation effect due to the X-ray irradiation has not been evaluated. Then, we conduct an X-ray irradiation experiment using an X-ray generator with a total dose of 10 krad at the SiO2 insulator, equivalent to 7 years in orbit. As a result of this experiment, the energy resolution in full-width half maximum for the 5.9 keV X-ray degrades by 17.8 $\pm$ 2.8% and the dark current increases by 89 $\pm$ 13%. We also investigate the physical mechanism of the increase in the dark current due to X-ray irradiation using TCAD simulation. It is found that the increase in the dark current can be explained by the increase in the interface state density at the Si/SiO2 interface.
△ Less
Submitted 26 May, 2022;
originally announced May 2022.
-
Proton radiation hardness of X-ray SOI pixel sensors with pinned depleted diode structure
Authors:
Mitsuki Hayashida,
Kouichi Hagino,
Takayoshi Kohmura,
Masatoshi Kitajima,
Keigo Yarita,
Kenji Oono,
Kousuke Negishi,
Takeshi G. Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Kazuho Kayama,
Ryota Kodama,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Takahiro Hida,
Masataka Yukumoto,
Yasuo Arai,
Ikuo Kurachi,
Hisashi Kitamura,
Shoji Kawahito,
Keita Yasutomi
Abstract:
X-ray SOI pixel sensors, "XRPIX", are being developed for the next-generation X-ray astronomical satellite, "FORCE". The XRPIX are fabricated with the SOI technology, which makes it possible to integrate a high-resistivity Si sensor and a low-resistivity Si CMOS circuit. The CMOS circuit in each pixel is equipped with a trigger function, allowing us to read out outputs only from the pixels with X-…
▽ More
X-ray SOI pixel sensors, "XRPIX", are being developed for the next-generation X-ray astronomical satellite, "FORCE". The XRPIX are fabricated with the SOI technology, which makes it possible to integrate a high-resistivity Si sensor and a low-resistivity Si CMOS circuit. The CMOS circuit in each pixel is equipped with a trigger function, allowing us to read out outputs only from the pixels with X-ray signals at the timing of X-ray detection. This function thus realizes high throughput and high time resolution, which enables to employ anti-coincidence technique for background rejection. A new series of XRPIX named XRPIX6E developed with a pinned depleted diode (PDD) structure improves spectral performance by suppressing the interference between the sensor and circuit layers. When semiconductor X-ray sensors are used in space, their spectral performance is generally degraded owing to the radiation damage caused by high-energy protons. Therefore, before using an XRPIX in space, it is necessary to evaluate the extent of degradation of its spectral performance by radiation damage. Thus, we performed a proton irradiation experiment for XRPIX6E for the first time at HIMAC in the NIRS. We irradiated XRPIX6E with high-energy protons with a total dose of up to 40 krad, equivalent to 400 years of irradiation in orbit. The 40-krad irradiation degraded the energy resolution of XRPIX6E by 25 $\pm$ 3%, yielding an energy resolution of 260.1 $\pm$ 5.6 eV at the full width half maximum for 5.9 keV X-rays. However, the value satisfies the requirement for FORCE, 300 eV at 6 keV, even after the irradiation. It was also found that the PDD XRPIX has enhanced radiation hardness compared to previous XRPIX devices. In addition, we investigated the degradation of the energy resolution; it was shown that the degradation would be due to increasing energy-independent components, e.g., readout noise.
△ Less
Submitted 11 August, 2021;
originally announced August 2021.
-
Low-Energy X-ray Performance of SOI Pixel Sensors for Astronomy, "XRPIX"
Authors:
Ryota Kodama,
Takeshi Go Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Kazuho Kayama,
Yuki Amano,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Masataka Yukumoto,
Takahiro Hida,
Yasuo Arai,
Ikuo Kurachi,
Takayoshi Kohmura,
Kouichi Hagino,
Mitsuki Hayashida,
Masatoshi Kitajima,
Shoji Kawahito,
Keita Yasutomi,
Hiroki Kamehama
Abstract:
We have been developing a new type of X-ray pixel sensors, "XRPIX", allowing us to perform imaging spectroscopy in the wide energy band of 1-20 keV for the future Japanese X-ray satellite "FORCE". The XRPIX devices are fabricated with complementary metal-oxide-semiconductor silicon-on-insulator technology, and have the "Event-Driven readout mode", in which only a hit event is read out by using hit…
▽ More
We have been developing a new type of X-ray pixel sensors, "XRPIX", allowing us to perform imaging spectroscopy in the wide energy band of 1-20 keV for the future Japanese X-ray satellite "FORCE". The XRPIX devices are fabricated with complementary metal-oxide-semiconductor silicon-on-insulator technology, and have the "Event-Driven readout mode", in which only a hit event is read out by using hit information from a trigger output function equipped with each pixel. This paper reports on the low-energy X-ray performance of the "XRPIX6E" device with a Pinned Depleted Diode (PDD) structure. The PDD structure especially reduces the readout noise, and hence is expected to largely improve the quantum efficiencies for low-energy X-rays. While F-K X-rays at 0.68 keV and Al-K X-rays at 1.5 keV are successfully detected in the "Frame readout mode", in which all pixels are read out serially without using the trigger output function, the device is able to detect Al-K X-rays, but not F-K X-rays in the Event-Driven readout mode. Non-uniformity is observed in the counts maps of Al-K X-rays in the Event-Driven readout mode, which is due to region-to-region variation of the pedestal voltages at the input to the comparator circuit. The lowest available threshold energy is 1.1 keV for a small region in the device where the non-uniformity is minimized. The noise of the charge sensitive amplifier at the sense node and the noise related to the trigger output function are ~$18~e^-$ (rms) and ~$13~e^-$ (rms), respectively.
△ Less
Submitted 29 September, 2020;
originally announced September 2020.
-
Experimental studies on the charge transfer inefficiency of CCD developed for the soft X-ray imaging telescope Xtend aboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
Jin Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Mariko Saito,
Kumiko K. Nobukawa,
Takaaki Tanaka,
Hiroyuki Uchida,
Kiyoshi Hayashida,
Hironori Matsumoto,
Hirofumi Noda,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hiroshi Tomida,
Hikari Kashimura,
Hiroshi Nakajima
, et al. (16 additional authors not shown)
Abstract:
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the…
▽ More
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI) capability, in which sacrificial charge is periodically injected to fill the charge traps. By evaluating the re-emission of the trapped charge observed behind the CI rows, we find that there are at least three trap populations with different time constants. The traps with the shortest time constant, which is equivalent to a transfer time of approximately one pixel, are mainly responsible for the trailing charge of an X-ray event seen in the following pixel. A comparison of the trailing charge in two clocking modes reveals that the CTI depends not only on the transfer time but also on the area, namely the imaging or storage area. We construct a new CTI model with taking into account with both transfer-time and area dependence. This model reproduces the data obtained in both clocking modes consistently. We also examine apparent flux dependence of the CTI observed without the CI technique. The higher incident X-ray flux is, the lower the CTI value becomes. It is due to a sacrificial charge effect by another X-ray photon. This effect is found to be negligible when the CI technique is used.
△ Less
Submitted 15 September, 2020; v1 submitted 14 September, 2020;
originally announced September 2020.
-
Radiation Damage Effects on Double-SOI Pixel Sensors for X-ray Astronomy
Authors:
Kouichi Hagino,
Keigo Yarita,
Kousuke Negishi,
Kenji Oono,
Mitsuki Hayashida,
Masatoshi Kitajima,
Takayoshi Kohmura,
Takeshi G. Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Kazuho Kayama,
Yuki Amano,
Ryota Kodama,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Masataka Yukumoto,
Takahiro Hida,
Yasuo Arai,
Ikuo Kurachi,
Tsuyoshi Hamano,
Hisashi Kitamura
Abstract:
The X-ray SOI pixel sensor onboard the FORCE satellite will be placed in the low earth orbit and will consequently suffer from the radiation effects mainly caused by geomagnetically trapped cosmic-ray protons. Based on previous studies on the effects of radiation on SOI pixel sensors, the positive charges trapped in the oxide layer significantly affect the performance of the sensor. To improve the…
▽ More
The X-ray SOI pixel sensor onboard the FORCE satellite will be placed in the low earth orbit and will consequently suffer from the radiation effects mainly caused by geomagnetically trapped cosmic-ray protons. Based on previous studies on the effects of radiation on SOI pixel sensors, the positive charges trapped in the oxide layer significantly affect the performance of the sensor. To improve the radiation hardness of the SOI pixel sensors, we introduced a double-SOI (D-SOI) structure containing an additional middle Si layer in the oxide layer. The negative potential applied on the middle Si layer compensates for the radiation effects, due to the trapped positive charges. Although the radiation hardness of the D-SOI pixel sensors for applications in high-energy accelerators has been evaluated, radiation effects for astronomical application in the D-SOI sensors has not been evaluated thus far. To evaluate the radiation effects of the D-SOI sensor, we perform an irradiation experiment using a 6-MeV proton beam with a total dose of ~ 5 krad, corresponding to a few tens of years of in-orbit operation. This experiment indicates an improvement in the radiation hardness of the X- ray D-SOI devices. On using an irradiation of 5 krad on the D-SOI device, the energy resolution in the full-width half maximum for the 5.9-keV X-ray increases by 7 $\pm$ 2%, and the chip output gain decreases by 0.35 $\pm$ 0.09%. The physical mechanism of the gain degradation is also investigated; it is found that the gain degradation is caused by an increase in the parasitic capacitance due to the enlarged buried n-well.
△ Less
Submitted 16 July, 2020;
originally announced July 2020.
-
Optical Blocking Performance of CCDs Developed for the X-ray Astronomy Satellite XRISM
Authors:
Hiroyuki Uchida,
Takaaki Tanaka,
Yuki Amano,
Hiromichi Okon,
Takeshi G. Tsuru,
Hirofumi Noda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Maho Hanaoka,
Tomokage Yoneyama,
Koki Okazaki,
Kazunori Asakura,
Shotaro Sakuma,
Kengo Hattori,
Ayami Ishikura,
Hiroshi Nakajima,
Mariko Saito,
Kumiko K. Nobukawa,
Hiroshi Tomida,
Yoshiaki Kanemaru,
Jin Sato,
Toshiyuki Takaki,
Yuta Terada,
Koji Mori,
Hikari Kashimura
, et al. (21 additional authors not shown)
Abstract:
We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopte…
▽ More
We have been developing P-channel Charge-Coupled Devices (CCDs) for the upcoming X-ray Astronomy Satellite XRISM, planned to be launched in 2021. While the basic design of the CCD camera (Soft X-ray Imager: SXI) is almost the same as that of the lost Hitomi (ASTRO-H) observatory, we are planning to reduce the "light leakages" that is one of the largest problems recognized in Hitomi data. We adopted a double-layer optical blocking layer on the XRISM CCDs and also added an extra aluminum layer on the backside of them. We develop a newly designed test sample CCD and irradiate it with optical light to evaluate the optical blocking performance. As a result, light leakages are effectively reduced compared with that of the Hitomi CCDs. We thus conclude that the issue is solved by the new design and that the XRISM CCDs satisfy the mission requirement for the SXI.
△ Less
Submitted 16 July, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.
-
Sub-pixel Response of Double-SOI Pixel Sensors for X-ray Astronomy
Authors:
K. Hagino,
K. Negishi,
K. Oono,
K. Yarita,
T. Kohmura,
T. G. Tsuru,
T. Tanaka,
S. Harada,
K. Kayama,
H. Matsumura,
K. Mori,
A. Takeda,
Y. Nishioka,
M. Yukumoto,
K. Fukuda,
T. Hida,
Y. Arai,
I. Kurachi,
S. Kishimoto
Abstract:
We have been developing the X-ray silicon-on-insulator (SOI) pixel sensor called XRPIX for future astrophysical satellites. XRPIX is a monolithic active pixel sensor consisting of a high-resistivity Si sensor, thin SiO$_2$ insulator, and CMOS pixel circuits that utilize SOI technology. Since XRPIX is capable of event-driven readouts, it can achieve high timing resolution greater than…
▽ More
We have been developing the X-ray silicon-on-insulator (SOI) pixel sensor called XRPIX for future astrophysical satellites. XRPIX is a monolithic active pixel sensor consisting of a high-resistivity Si sensor, thin SiO$_2$ insulator, and CMOS pixel circuits that utilize SOI technology. Since XRPIX is capable of event-driven readouts, it can achieve high timing resolution greater than $\sim 10{\rm ~μs}$, which enables low background observation by adopting the anti-coincidence technique. One of the major issues in the development of XRPIX is the electrical interference between the sensor layer and circuit layer, which causes nonuniform detection efficiency at the pixel boundaries. In order to reduce the interference, we introduce a Double-SOI (D-SOI) structure, in which a thin Si layer (middle Si) is added to the insulator layer of the SOI structure. In this structure, the middle Si layer works as an electrical shield to decouple the sensor layer and circuit layer. We measured the detector response of the XRPIX with D-SOI structure at KEK. We irradiated the X-ray beam collimated with $4{\rm ~μmφ}$ pinhole, and scanned the device with $6{\rm ~μm}$ pitch, which is 1/6 of the pixel size. In this paper, we present the improvement in the uniformity of the detection efficiency in D-SOI sensors, and discuss the detailed X-ray response and its physical origins.
△ Less
Submitted 26 August, 2019;
originally announced August 2019.
-
Radiation hardness of a p-channel notch CCD developed for the X-ray CCD camera onboard the XRISM satellite
Authors:
Yoshiaki Kanemaru,
Jin Sato,
Koji Mori,
Hiroshi Nakajima,
Yusuke Nishioka,
Ayaki Takeda,
Kiyoshi Hayashida,
Hironori Matsumoto,
Junichi Iwagaki,
Koki Okazaki,
Kazunori Asakura,
Tomokage Yoneyama,
Hiroyuki Uchida,
Hiromichi Okon,
Takaaki Tanaka,
Takeshi G. Tsuru,
Hiroshi Tomida,
Takeo Shimoi,
Takayoshi Kohmura,
Kouichi Hagino,
Hiroshi Murakami,
Shogo B. Kobayashi,
Makoto Yamauchi,
Isamu Hatsukade,
Masayoshi Nobukawa
, et al. (8 additional authors not shown)
Abstract:
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately…
▽ More
We report the radiation hardness of a p-channel CCD developed for the X-ray CCD camera onboard the XRISM satellite. This CCD has basically the same characteristics as the one used in the previous Hitomi satellite, but newly employs a notch structure of potential for signal charges by increasing the implant concentration in the channel. The new device was exposed up to approximately $7.9 \times 10^{10} \mathrm{~protons~cm^{-2}}$ at 100 MeV. The charge transfer inefficiency was estimated as a function of proton fluence with an ${}^{55} \mathrm{Fe}$ source. A device without the notch structure was also examined for comparison. The result shows that the notch device has a significantly higher radiation hardness than those without the notch structure including the device adopted for Hitomi. This proves that the new CCD is radiation tolerant for space applications with a sufficient margin.
△ Less
Submitted 1 June, 2019;
originally announced June 2019.
-
Measurement of Charge Cloud Size in X-ray SOI Pixel Sensors
Authors:
Kouichi Hagino,
Kenji Oono,
Kousuke Negishi,
Keigo Yarita,
Takayoshi Kohmura,
Takeshi G. Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Sodai Harada,
Tomoyuki Okuno,
Kazuho Kayama,
Yuki Amano,
Hideaki Matsumura,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Kohei Fukuda,
Takahiro Hida,
Masataka Yukumoto,
Yasuo Arai,
Ikuo Kurachi,
Toshinobu Miyoshi,
Shunji Kishimoto
Abstract:
We report on a measurement of the size of charge clouds produced by X-ray photons in X-ray SOI (Silicon-On-Insulator) pixel sensor named XRPIX. We carry out a beam scanning experiment of XRPIX using a monochromatic X-ray beam at 5.0 keV collimated to $\sim 10$ $μ$m with a 4-$μ$m$φ$ pinhole, and obtain the spatial distribution of single-pixel events at a sub-pixel scale. The standard deviation of c…
▽ More
We report on a measurement of the size of charge clouds produced by X-ray photons in X-ray SOI (Silicon-On-Insulator) pixel sensor named XRPIX. We carry out a beam scanning experiment of XRPIX using a monochromatic X-ray beam at 5.0 keV collimated to $\sim 10$ $μ$m with a 4-$μ$m$φ$ pinhole, and obtain the spatial distribution of single-pixel events at a sub-pixel scale. The standard deviation of charge clouds of 5.0 keV X-ray is estimated to be $σ_{\rm cloud} = 4.30 \pm 0.07$ $μ$m. Compared to the detector response simulation, the estimated charge cloud size is well explained by a combination of photoelectron range, thermal diffusion, and Coulomb repulsion. Moreover, by analyzing the fraction of multi-pixel events in various energies, we find that the energy dependence of the charge cloud size is also consistent with the simulation.
△ Less
Submitted 30 May, 2019;
originally announced May 2019.
-
Subpixel Response of SOI Pixel Sensor for X-ray Astronomy with Pinned Depleted Diode: First Result from Mesh Experiment
Authors:
Kazuho Kayama,
Takeshi G. Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Sodai Harada,
Tomoyuki Okuno,
Yuki Amano,
Junko S. Hiraga,
Masayuki Yoshida,
Yasuaki Kamata,
Shotaro Sakuma,
Daito Yuhi,
Yukino Urabe,
Hiroshi Tsunemi,
Hideaki Matsumura,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Syunta Nakanishi,
Hiroki Kamehama,
Yasuo Arai,
Ikuo Kurachi,
Ayaki Takeda,
Koji Mori
, et al. (9 additional authors not shown)
Abstract:
We have been developing a monolithic active pixel sensor, ``XRPIX``, for the Japan led future X-ray astronomy mission ``FORCE`` observing the X-ray sky in the energy band of 1-80 keV with angular resolution of better than 15``. XRPIX is an upper part of a stack of two sensors of an imager system onboard FORCE, and covers the X-ray energy band lower than 20 keV. The XRPIX device consists of a fully…
▽ More
We have been developing a monolithic active pixel sensor, ``XRPIX``, for the Japan led future X-ray astronomy mission ``FORCE`` observing the X-ray sky in the energy band of 1-80 keV with angular resolution of better than 15``. XRPIX is an upper part of a stack of two sensors of an imager system onboard FORCE, and covers the X-ray energy band lower than 20 keV. The XRPIX device consists of a fully depleted high-resistivity silicon sensor layer for X-ray detection, a low resistivity silicon layer for CMOS readout circuit, and a buried oxide layer in between, which is fabricated with 0.2 $μ$ m CMOS silicon-on-insulator (SOI) technology. Each pixel has a trigger circuit with which we can achieve a 10 $μ$ s time resolution, a few orders of magnitude higher than that with X-ray astronomy CCDs. We recently introduced a new type of a device structure, a pinned depleted diode (PDD), in the XRPIX device, and succeeded in improving the spectral performance, especially in a readout mode using the trigger function. In this paper, we apply a mesh experiment to the XRPIX devices for the first time in order to study the spectral response of the PDD device at the subpixel resolution. We confirmed that the PDD structure solves the significant degradation of the charge collection efficiency at the pixel boundaries and in the region under the pixel circuits, which is found in the single SOI structure, the conventional type of the device structure. On the other hand, the spectral line profiles are skewed with low energy tails and the line peaks slightly shift near the pixel boundaries, which contribute to a degradation of the energy resolution.
△ Less
Submitted 26 May, 2019;
originally announced May 2019.
-
Evaluation of Kyoto's Event-Driven X-ray Astronomical SOI Pixel Sensor with a Large Imaging Area
Authors:
Hideki Hayashi,
Takeshi Go Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Hideaki Matsumura,
Katsuhiro Tachibana,
Sodai Harada,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Yasuo Arai,
Ikuo Kurachi,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Syunta Nakanishi,
Hiroki Kamehama,
Takayoshi Kohmura,
Kouichi Hagino,
Kousuke Negishi,
Kenji Oono
, et al. (1 additional authors not shown)
Abstract:
We have been developing monolithic active pixel sensors, named ``XRPIX'', based on the silicon-on-insulator (SOI) pixel technology for future X-ray astronomy satellites. XRPIX has the function of event trigger and hit address outputs. This function allows us to read out analog signals only of hit pixels on trigger timing, which is referred to as the event-driven readout mode. Recently, we processe…
▽ More
We have been developing monolithic active pixel sensors, named ``XRPIX'', based on the silicon-on-insulator (SOI) pixel technology for future X-ray astronomy satellites. XRPIX has the function of event trigger and hit address outputs. This function allows us to read out analog signals only of hit pixels on trigger timing, which is referred to as the event-driven readout mode. Recently, we processed ``XRPIX5b'' with the largest imaging area of 21.9~mm $\times$ 13.8~mm in the XRPIX series. X-ray spectra are successfully obtained from all the pixels, and the readout noise is 46~e$^-$~(rms) in the frame readout mode. The gain variation was measured to be 1.2\%~(FWHM) among the pixels. We successfully obtain the X-ray image in the event-driven readout mode.
△ Less
Submitted 29 April, 2019;
originally announced April 2019.
-
Performance of SOI Pixel Sensors Developed for X-ray Astronomy
Authors:
Takaaki Tanaka,
Takeshi Go Tsuru,
Hiroyuki Uchida,
Sodai Harada,
Tomoyuki Okuno,
Kazuho Kayama,
Yuki Amano,
Hideaki Matsumura,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Kohei Fukuda,
Takahiro Hida,
Masataka Yukumoto,
Yasuo Arai,
Ikuo Kurachi,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Syunta Nakanishi,
Hiroki Kamehama,
Takayoshi Kohmura,
Kouichi Hagino,
Kousuke Negishi
, et al. (2 additional authors not shown)
Abstract:
We have been developing monolithic active pixel sensors for X-rays based on the silicon-on-insulator technology. Our device consists of a low-resistivity Si layer for readout CMOS electronics, a high-resistivity Si sensor layer, and a SiO$_2$ layer between them. This configuration allows us both high-speed readout circuits and a thick (on the order of $100~μ{\rm m}$) depletion layer in a monolithi…
▽ More
We have been developing monolithic active pixel sensors for X-rays based on the silicon-on-insulator technology. Our device consists of a low-resistivity Si layer for readout CMOS electronics, a high-resistivity Si sensor layer, and a SiO$_2$ layer between them. This configuration allows us both high-speed readout circuits and a thick (on the order of $100~μ{\rm m}$) depletion layer in a monolithic device. Each pixel circuit contains a trigger output function, with which we can achieve a time resolution of $\lesssim 10~μ{\rm s}$. One of our key development items is improvement of the energy resolution. We recently fabricated a device named XRPIX6E, to which we introduced a pinned depleted diode (PDD) structure. The structure reduces the capacitance coupling between the sensing area in the sensor layer and the pixel circuit, which degrades the spectral performance. With XRPIX6E, we achieve an energy resolution of $\sim 150$~eV in full width at half maximum for 6.4-keV X-rays. In addition to the good energy resolution, a large imaging area is required for practical use. We developed and tested XRPIX5b, which has an imaging area size of $21.9~{\rm mm} \times 13.8~{\rm mm}$ and is the largest device that we ever fabricated. We successfully obtain X-ray data from almost all the $608 \times 384$ pixels with high uniformity.
△ Less
Submitted 14 December, 2018;
originally announced December 2018.
-
X-ray response evaluation in subpixel level for X-ray SOI pixel detectors
Authors:
Kousuke Negishi,
Takayoshi Kohmura,
Kouichi Hagino,
Taku Kogiso,
Kenji Oono,
Keigo Yarita,
Akinori Sasaki,
Koki Tamasawa,
Takeshi G. Tsuru,
Takaaki Tanaka,
Hideaki Matsumura,
Katsuhiro Tachibana,
Hideki Hayashi,
Sodai Harada,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Yasuo Arai,
Toshinobu Miyoshi,
Shunji Kishimoto,
Ikuo Kurachi
Abstract:
We have been developing event-driven SOI Pixel Detectors, named `XRPIX' (X-Ray soiPIXel) based on the silicon-on-insulator (SOI) pixel technology, for the future X-ray astronomical satellite with wide band coverage from 0.5 keV to 40 keV. XRPIX has event trigger output function at each pixel to acquire a good time resolution of a few $μ\rm s$ and has Correlated Double Sampling function to reduce e…
▽ More
We have been developing event-driven SOI Pixel Detectors, named `XRPIX' (X-Ray soiPIXel) based on the silicon-on-insulator (SOI) pixel technology, for the future X-ray astronomical satellite with wide band coverage from 0.5 keV to 40 keV. XRPIX has event trigger output function at each pixel to acquire a good time resolution of a few $μ\rm s$ and has Correlated Double Sampling function to reduce electric noises. The good time resolution enables the XRPIX to reduce Non X-ray Background in the high energy band above 10\,keV drastically by using anti-coincidence technique with active shield counters surrounding XRPIX. In order to increase the soft X-ray sensitivity, it is necessary to make the dead layer on the X-ray incident surface as thin as possible. Since XRPIX1b, which is a device at the initial stage of development, is a front-illuminated (FI) type of XRPIX, low energy X-ray photons are absorbed in the 8 $\rm μ$m thick circuit layer, lowering the sensitivity in the soft X-ray band. Therefore, we developed a back-illuminated (BI) device XRPIX2b, and confirmed high detection efficiency down to 2.6 keV, below which the efficiency is affected by the readout noise. In order to further improve the detection efficiency in the soft X-ray band, we developed a back-illuminated device XRPIX3b with lower readout noise. In this work, we irradiated 2--5 keV X-ray beam collimated to 4 $\rm μm φ$ to the sensor layer side of the XRPIX3b at 6 $\rm μm$ pitch. In this paper, we reported the uniformity of the relative detection efficiency, gain and energy resolution in the subpixel level for the first time. We also confirmed that the variation in the relative detection efficiency at the subpixel level reported by Matsumura et al. has improved.
△ Less
Submitted 25 October, 2018;
originally announced October 2018.
-
Proton Radiation Damage Experiment for X-Ray SOI Pixel Detectors
Authors:
Keigo Yarita,
Takayoshi Kohmura,
Kouichi Hagino,
Taku Kogiso,
Kenji Oono,
Kousuke Negishi,
Koki Tamasawa,
Akinori Sasaki,
Satoshi Yoshiki,
Takeshi Go Tsuru,
Takaaki Tanaka,
Hideaki Matsumura,
Katsuhiro Tachibana,
Hideki Hayashi,
Sodai Harada,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Yasuo Arai,
Toshinobu Miyoshi,
Ikuo Kurachi,
Tsuyoshi Hamano
, et al. (1 additional authors not shown)
Abstract:
In low earth orbit, there are many cosmic rays composed primarily of high energy protons. These cosmic rays cause surface and bulk radiation effects, resulting in degradation of detector performance. Quantitative evaluation of radiation hardness is essential in development of X-ray detectors for astronomical satellites. We performed proton irradiation experiments on newly developed X-ray detectors…
▽ More
In low earth orbit, there are many cosmic rays composed primarily of high energy protons. These cosmic rays cause surface and bulk radiation effects, resulting in degradation of detector performance. Quantitative evaluation of radiation hardness is essential in development of X-ray detectors for astronomical satellites. We performed proton irradiation experiments on newly developed X-ray detectors called XRPIX based on silicon-on-insulator technology at HIMAC in National Institute of Radiological Sciences. We irradiated 6 MeV protons with a total dose of 0.5 krad, equivalent to 6 years irradiation in orbit. As a result, the gain increases by 0.2% and the energy resolution degrades by 0.5%. Finally we irradiated protons up to 20 krad and found that detector performance degraded significantly at 5 krad. With 5 krad irradiation corresponding to 60 years in orbit, the gain increases by 0.7% and the energy resolution worsens by 10%. By decomposing into noise components, we found that the increase of the circuit noise is dominant in the degradation of the energy resolution.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.
-
Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. S…
▽ More
We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.
△ Less
Submitted 1 October, 2018;
originally announced October 2018.
-
Performance of the Silicon-On-Insulator Pixel Sensor for X-ray Astronomy, XRPIX6E, Equipped with Pinned Depleted Diode Structure
Authors:
Sodai Harada,
Takeshi Go Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Hideaki Matsumura,
Katsuhiro Tachibana,
Hideki Hayashi,
Ayaki Takeda,
Koji Mori,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Yasuo Arai,
Ikuo Kurachi,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Syunta Nakanishi,
Hiroki Kamehama,
Takayoshi Kohmura,
Kouichi Hagino,
Kousuke Negishi,
Kenji Oono
, et al. (1 additional authors not shown)
Abstract:
We have been developing event driven X-ray Silicon-On-Insulator (SOI) pixel sensors, called "XRPIX", for the next generation of X-ray astronomy satellites. XRPIX is a monolithic active pixel sensor, fabricated using the SOI CMOS technology, and is equipped with the so-called "Event-Driven readout", which allows reading out only hit pixels by using the trigger circuit implemented in each pixel. The…
▽ More
We have been developing event driven X-ray Silicon-On-Insulator (SOI) pixel sensors, called "XRPIX", for the next generation of X-ray astronomy satellites. XRPIX is a monolithic active pixel sensor, fabricated using the SOI CMOS technology, and is equipped with the so-called "Event-Driven readout", which allows reading out only hit pixels by using the trigger circuit implemented in each pixel. The current version of XRPIX has lower spectral performance in the Event-Driven readout mode than in the Frame readout mode, which is due to the interference between the sensor layer and the circuit layer. The interference also lowers the gain. In order to suppress the interference, we developed a new device, "XRPIX6E" equipped with the Pinned Depleted Diode structure. A sufficiently highly-doped buried p-well is formed at the interface between the buried oxide layer and the sensor layer, and acts as a shield layer. XRPIX6E exhibits improved spectral performances both in the Event-Driven readout mode and in the Frame readout mode in comparison to previous devices. The energy resolutions in full width at half maximum at 6.4 keV are 236 $\pm$ 1 eV and 335 $\pm$ 4 eV in the Frame and Event-Driven readout modes, respectively. There are differences between the readout noise and the spectral performance in the two modes, which suggests that some mechanism still degrades the performance in the Event-Driven readout mode.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
Kyoto's Event-Driven X-ray Astronomy SOI pixel sensor for the FORCE mission
Authors:
Takeshi G. Tsuru,
Hideki Hayashi,
Katsuhiro Tachibana,
Sodai Harada,
Hiroyuki Uchida,
Takaaki Tanaka,
Yasuo Arai,
Ikuo Kurachi,
Koji Mori,
Ayaki Takeda,
Yusuke Nishioka,
Nobuaki Takebayashi,
Shoma Yokoyama,
Kohei Fukuda,
Takayoshi Kohmura,
Kouichi Hagino,
Kenji Ohno,
Kohsuke Negishi,
Keigo Yarita,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Sumeet Shrestha,
Shunta Nakanishi,
Hiroki Kamehama
, et al. (1 additional authors not shown)
Abstract:
We have been developing monolithic active pixel sensors, X-ray Astronomy SOI pixel sensors, XRPIXs, based on a Silicon-On-Insulator (SOI) CMOS technology as soft X-ray sensors for a future Japanese mission, FORCE (Focusing On Relativistic universe and Cosmic Evolution). The mission is characterized by broadband (1-80 keV) X-ray imaging spectroscopy with high angular resolution ($<15$~arcsec), with…
▽ More
We have been developing monolithic active pixel sensors, X-ray Astronomy SOI pixel sensors, XRPIXs, based on a Silicon-On-Insulator (SOI) CMOS technology as soft X-ray sensors for a future Japanese mission, FORCE (Focusing On Relativistic universe and Cosmic Evolution). The mission is characterized by broadband (1-80 keV) X-ray imaging spectroscopy with high angular resolution ($<15$~arcsec), with which we can achieve about ten times higher sensitivity in comparison to the previous missions above 10~keV. Immediate readout of only those pixels hit by an X-ray is available by an event trigger output function implemented in each pixel with the time resolution higher than $10~{\rm μsec}$ (Event-Driven readout mode). It allows us to do fast timing observation and also reduces non-X-ray background dominating at a high X-ray energy band above 5--10~keV by adopting an anti-coincidence technique. In this paper, we introduce our latest results from the developments of the XRPIXs. (1) We successfully developed a 3-side buttable back-side illumination device with an imaging area size of 21.9~mm$\times$13.8~mm and an pixel size of $36~{\rm μm} \times 36~{\rm μm}$. The X-ray throughput with the device reaches higher than 0.57~kHz in the Event-Driven readout mode. (2) We developed a device using the double SOI structure and found that the structure improves the spectral performance in the Event-Driven readout mode by suppressing the capacitive coupling interference between the sensor and circuit layers. (3) We also developed a new device equipped with the Pinned Depleted Diode structure and confirmed that the structure reduces the dark current generated at the interface region between the sensor and the SiO$_2$ insulator layers. The device shows an energy resolution of 216~eV in FWHM at 6.4~keV in the Event-Driven readout mode.
△ Less
Submitted 29 July, 2018;
originally announced July 2018.
-
Hitomi X-ray Observation of the Pulsar Wind Nebula G21.5$-$0.9
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (173 additional authors not shown)
Abstract:
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with…
▽ More
We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Γ_1=1.74\pm0.02$ and $Γ_2=2.14\pm0.01$ below and above the break at $7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $σ$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
Soft X-ray Imager aboard Hitomi (ASTRO-H)
Authors:
Takaaki Tanaka,
Hiroyuki Uchida,
Hiroshi Nakajima,
Hiroshi Tsunemi,
Kiyoshi Hayashida,
Takeshi G. Tsuru,
Tadayasu Dotani,
Ryo Nagino,
Shota Inoue,
Shohei Katada,
Ryosaku Washino,
Masanobu Ozaki,
Hiroshi Tomida,
Chikara Natsukari,
Shutaro Ueda,
Masachika Iwai,
Koji Mori,
Makoto Yamauchi,
Isamu Hatsukade,
Yusuke Nishioka,
Eri Isoda,
Masayoshi Nobukawa,
Junko S. Hiraga,
Takayoshi Kohmura,
Hiroshi Murakami
, et al. (3 additional authors not shown)
Abstract:
The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2 \times 2$ array. Combined with the X-ray mirror, the Soft X-ray Telescope, the SXI detects X-rays between $0.4~{\rm keV}$ and $12~{\rm keV}$ and covers a…
▽ More
The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2 \times 2$ array. Combined with the X-ray mirror, the Soft X-ray Telescope, the SXI detects X-rays between $0.4~{\rm keV}$ and $12~{\rm keV}$ and covers a $38^{\prime} \times 38^{\prime}$ field-of-view. The CCDs are P-channel fully-depleted, back-illumination type with a depletion layer thickness of $200~μ{\rm m}$. Low operation temperature down to $-120~^\circ{\rm C}$ as well as charge injection is employed to reduce the charge transfer inefficiency of the CCDs. The functionality and performance of the SXI are verified in on-ground tests. The energy resolution measured is $161$-$170~{\rm eV}$ in full width at half maximum for $5.9~{\rm keV}$ X-rays. In the tests, we found that the CTI of some regions are significantly higher. A method is developed to properly treat the position-dependent CTI. Another problem we found is pinholes in the Al coating on the incident surface of the CCDs for optical light blocking. The Al thickness of the contamination blocking filter is increased in order to sufficiently block optical light.
△ Less
Submitted 2 February, 2018; v1 submitted 21 January, 2018;
originally announced January 2018.
-
Temperature Structure in the Perseus Cluster Core Observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated wi…
▽ More
The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated with an energy resolution of $\sim$5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV energy band.
△ Less
Submitted 18 December, 2017;
originally announced December 2017.
-
Atomic data and spectral modeling constraints from high-resolution X-ray observations of the Perseus cluster with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, a…
▽ More
The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, and are in close agreement on best-fit temperature, emission measure, and abundances of a few elements such as Ni. For the Fe abundance, the APEC and SPEX measurements differ by 16%, which is 17 times higher than the statistical uncertainty. This is mostly attributed to the differences in adopted collisional excitation and dielectronic recombination rates of the strongest emission lines. We further investigate and compare the sensitivity of the derived physical parameters to the astrophysical source modeling and instrumental effects. The Hitomi results show that an accurate atomic code is as important as the astrophysical modeling and instrumental calibration aspects. Substantial updates of atomic databases and targeted laboratory measurements are needed to get the current codes ready for the data from the next Hitomi-level mission.
△ Less
Submitted 14 December, 2017;
originally announced December 2017.
-
Hitomi Observations of the LMC SNR N132D: Highly Redshifted X-ray Emission from Iron Ejecta
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on t…
▽ More
We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on the plausible assumption that the Fe K emission is dominated by He-like ions, we find that the material responsible for this Fe emission is highly redshifted at ~800 km/s compared to the local LMC interstellar medium (ISM), with a 90% credible interval of 50-1500 km/s if a weakly informative prior is placed on possible line broadening. This indicates (1) that the Fe emission arises from the supernova ejecta, and (2) that these ejecta are highly asymmetric, since no blue-shifted component is found. The S K velocity is consistent with the local LMC ISM, and is likely from swept-up ISM material. These results are consistent with spatial mapping that shows the He-like Fe concentrated in the interior of the remnant and the S tracing the outer shell. The results also show that even with a very small number of counts, direct velocity measurements from Doppler-shifted lines detected in extended objects like supernova remnants are now possible. Thanks to the very low SXS background of ~1 event per spectral resolution element per 100 ks, such results are obtainable during short pointed or slew observations with similar instruments. This highlights the power of high-spectral-resolution imaging observations, and demonstrates the new window that has been opened with Hitomi and will be greatly widened with future missions such as the X-ray Astronomy Recovery Mission (XARM) and Athena.
△ Less
Submitted 6 December, 2017;
originally announced December 2017.
-
Glimpse of the highly obscured HMXB IGR J16318-4848 with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving p…
▽ More
We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving power of the X-ray microcalorimeter (the soft X-ray spectrometer; SXS) and the wide-band sensitivity by the soft and hard X-ray imager (SXI and HXI) aboard Hitomi. Even though photon counts are limited due to unintended off-axis pointing, the SXS spectrum resolves Fe K{α_1} and K{α_2} lines and puts strong constraints on the line centroid and width. The line width corresponds to the velocity of 160^{+300}_{-70} km s^{-1}. This represents the most accurate, and smallest, width measurement of this line made so far from any X-ray binary, much less than the Doppler broadening and shift expected from speeds which are characteristic of similar systems. Combined with the K-shell edge energy measured by the SXI and HXI spectra, the ionization state of Fe is estimated to be in the range of Fe I--IV. Considering the estimated ionization parameter and the distance between the X-ray source and the absorber, the density and thickness of the materials are estimated. The extraordinarily strong absorption and the absence of a Compton shoulder component is confirmed. These characteristics suggest reprocessing materials which are distributed in a narrow solid angle or scattering primarily with warm free electrons or neutral hydrogen.
△ Less
Submitted 21 November, 2017;
originally announced November 2017.
-
Development of a 32-channel ASIC for an X-ray APD Detector onboard the ISS
Authors:
M. Arimoto,
S. Harita,
S. Sugita,
Y. Yatsu,
N. Kawai,
H. Ikeda,
H. Tomida,
N. Isobe,
S. Ueno,
T. Mihara,
M. Serino,
T. Kohmura,
T. Sakamoto,
A. Yoshida,
H. Tsunemi,
S. Hatori,
K. Kume,
T. Hasegawa
Abstract:
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capabl…
▽ More
We report on the design and performance of a mixed-signal application specific integrated circuit (ASIC) dedicated to avalanche photodiodes (APDs) in order to detect hard X-ray emissions in a wide energy band onboard the International Space Station. To realize wide-band detection from 20 keV to 1 MeV, we use Ce:GAGG scintillators, each coupled to an APD, with low-noise front-end electronics capable of achieving a minimum energy detection threshold of 20 keV. The developed ASIC has the ability to read out 32-channel APD signals using 0.35 $μ$m CMOS technology, and an analog amplifier at the input stage is designed to suppress the capacitive noise primarily arising from the large detector capacitance of the APDs. The ASIC achieves a performance of 2099 e$^{-}$ + 1.5 e$^{-}$/pF at root mean square (RMS) with a wide 300 fC dynamic range. Coupling a reverse-type APD with a Ce:GAGG scintillator, we obtain an energy resolution of 6.7% (FWHM) at 662 keV and a minimum detectable energy of 20 keV at room temperature (20 $^{\circ}$C). Furthermore, we examine the radiation tolerance for space applications by using a 90 MeV proton beam, confirming that the ASIC is free of single-event effects and can operate properly without serious degradation in analog and digital processing.
△ Less
Submitted 17 November, 2017;
originally announced November 2017.
-
Hitomi Observation of Radio Galaxy NGC 1275: The First X-ray Microcalorimeter Spectroscopy of Fe-Kα Line Emission from an Active Galactic Nucleus
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (169 additional authors not shown)
Abstract:
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellit…
▽ More
The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellite of the Fanaroff-Riley type I radio galaxy NGC 1275 at the center of the Perseus cluster of galaxies. With the high energy resolution of ~5 eV at 6 keV achieved by Hitomi/SXS, we detected the Fe-Kα line with ~5.4 σ significance. The velocity width is constrained to be 500-1600 km s$^{-1}$ (FWHM for Gaussian models) at 90% confidence. The SXS also constrains the continuum level from the NGC 1275 nucleus up to ~20 keV, giving an equivalent width ~20 eV of the 6.4 keV line. Because the velocity width is narrower than that of broad Hα line of ~2750 km s$^{-1}$, we can exclude a large contribution to the line flux from the accretion disk and the broad line region. Furthermore, we performed pixel map analyses on the Hitomi/SXS data and image analyses on the Chandra archival data, and revealed that the Fe-Kα line comes from a region within ~1.6 kpc from the NGC 1275 core, where an active galactic nucleus emission dominates, rather than that from intracluster media. Therefore, we suggest that the source of the Fe-Kα line from NGC 1275 is likely a low-covering fraction molecular torus or a rotating molecular disk which probably extends from a pc to hundreds pc scale in the active galactic nucleus system.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Atmospheric gas dynamics in the Perseus cluster observed with Hitomi
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Rebecca E. A. Canning,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done
, et al. (173 additional authors not shown)
Abstract:
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the…
▽ More
Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the hot gas is remarkably low and mostly uniform. The velocity dispersion reaches maxima of approximately 200~km~s$^{-1}$ toward the central active galactic nucleus (AGN) and toward the AGN inflated north-western `ghost' bubble. Elsewhere within the observed region, the velocity dispersion appears constant around 100~km~s$^{-1}$. We also detect a velocity gradient with a 100~km~s$^{-1}$ amplitude across the cluster core, consistent with large-scale sloshing of the core gas. If the observed gas motions are isotropic, the kinetic pressure support is less than 10\% of the thermal pressure support in the cluster core. The well-resolved optically thin emission lines have Gaussian shapes, indicating that the turbulent driving scale is likely below 100~kpc, which is consistent with the size of the AGN jet inflated bubbles. We also report the first measurement of the ion temperature in the intracluster medium, which we find to be consistent with the electron temperature. In addition, we present a new measurement of the redshift to the brightest cluster galaxy NGC~1275.
△ Less
Submitted 1 November, 2017;
originally announced November 2017.
-
Measurements of resonant scattering in the Perseus cluster core with Hitomi SXS
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the ga…
▽ More
Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the gas in the core of the Perseus cluster. Here, we show that when inferring physical properties from line emissivities in systems like Perseus, the resonant scattering (RS) effect should be taken into account. In the Hitomi waveband, RS mostly affects the FeXXV He$α$ line ($w$) - the strongest line in the spectrum. The flux measured by Hitomi in this line is suppressed by a factor ~1.3 in the inner ~30 kpc, compared to predictions for an optically thin plasma; the suppression decreases with the distance from the center. The $w$ line also appears slightly broader than other lines from the same ion. The observed distortions of the $w$ line flux, shape and distance dependence are all consistent with the expected effect of the resonant scattering in the Perseus core. By measuring the ratio of fluxes in optically thick ($w$) and thin (FeXXV forbidden, He$β$, Ly$α$) lines, and comparing these ratios with predictions from Monte Carlo radiative transfer simulations, the velocities of gas motions have been obtained. The results are consistent with the direct measurements of gas velocities from line broadening described elsewhere in this series, although the systematic and statistical uncertainties remain significant. Further improvements in the predictions of line emissivities in plasma models, and deeper observations with future X-ray missions will enable RS measurements to provide powerful constraints on the amplitude and anisotropy of clusters gas motions.
△ Less
Submitted 11 October, 2017;
originally announced October 2017.
-
In-orbit performance of the soft X-ray imaging system aboard Hitomi (ASTRO-H)
Authors:
H. Nakajima,
Y. Maeda,
H. Uchida,
T. Tanaka,
H. Tsunemi,
K. Hayashida,
T. G. Tsuru,
T. Dotani,
R. Nagino,
S. Inoue,
M. Ozaki,
H. Tomida,
C. Natsukari,
S. Ueda,
K. Mori,
M. Yamauchi,
I. Hatsukade,
Y. Nishioka,
M. Sakata,
T. Beppu,
D. Honda,
M. Nobukawa,
J. S. Hiraga,
T. Kohmura,
H. Murakami
, et al. (24 additional authors not shown)
Abstract:
We describe the in-orbit performance of the soft X-ray imaging system consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi. Verification and calibration of imaging and spectroscopic performance are carried out making the best use of the limited data of less than three weeks. Basic performance including a large field of view of 38'x38' is verified with the first light imag…
▽ More
We describe the in-orbit performance of the soft X-ray imaging system consisting of the Soft X-ray Telescope and the Soft X-ray Imager aboard Hitomi. Verification and calibration of imaging and spectroscopic performance are carried out making the best use of the limited data of less than three weeks. Basic performance including a large field of view of 38'x38' is verified with the first light image of the Perseus cluster of galaxies. Amongst the small number of observed targets, the on-minus-off pulse image for the out-of-time events of the Crab pulsar enables us to measure a half power diameter of the telescope as about 1.3'. The average energy resolution measured with the onboard calibration source events at 5.89 keV is 179 pm 3 eV in full width at half maximum. Light leak and cross talk issues affected the effective exposure time and the effective area, respectively, because all the observations were performed before optimizing an observation schedule and parameters for the dark level calculation. Screening the data affected by these two issues, we measure the background level to be 5.6x10^{-6} counts s^{-1} arcmin^{-2} cm^{-2} in the energy band of 5-12 keV, which is seven times lower than that of the Suzaku XIS-BI.
△ Less
Submitted 26 September, 2017;
originally announced September 2017.
-
Hitomi X-ray studies of Giant Radio Pulses from the Crab pulsar
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (179 additional authors not shown)
Abstract:
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance…
▽ More
To search for giant X-ray pulses correlated with the giant radio pulses (GRPs) from the Crab pulsar, we performed a simultaneous observation of the Crab pulsar with the X-ray satellite Hitomi in the 2 -- 300 keV band and the Kashima NICT radio observatory in the 1.4 -- 1.7 GHz band with a net exposure of about 2 ks on 25 March 2016, just before the loss of the Hitomi mission.The timing performance of the Hitomi instruments was confirmed to meet the timing requirement and about 1,000 and 100 GRPs were simultaneously observed at the main and inter-pulse phases, respectively, and we found no apparent correlation between the giant radio pulses and the X-ray emission in either the main or inter-pulse phases.All variations are within the 2 sigma fluctuations of the X-ray fluxes at the pulse peaks, and the 3 sigma upper limits of variations of main- or inter- pulse GRPs are 22\% or 80\% of the peak flux in a 0.20 phase width, respectively, in the 2 -- 300 keV band.The values become 25\% or 110\% for main or inter-pulse GRPs, respectively, when the phase width is restricted into the 0.03 phase.Among the upper limits from the Hitomi satellite, those in the 4.5-10 keV and the 70-300 keV are obtained for the first time, and those in other bands are consistent with previous reports.Numerically, the upper limits of main- and inter-pulse GRPs in the 0.20 phase width are about (2.4 and 9.3) $\times 10^{-11}$ erg cm$^{-2}$, respectively. No significant variability in pulse profiles implies that the GRPs originated from a local place within the magnetosphere and the number of photon-emitting particles temporally increases.However, the results do not statistically rule out variations correlated with the GRPs, because the possible X-ray enhancement may appear due to a $>0.02$\% brightening of the pulse-peak flux under such conditions.
△ Less
Submitted 7 August, 2017; v1 submitted 27 July, 2017;
originally announced July 2017.
-
Search for Thermal X-ray Features from the Crab nebula with Hitomi Soft X-ray Spectrometer
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger Blandford,
Laura W. Brenneman,
Greg V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo S. Coppi,
Elisa Costantini,
Jelle de Plaa,
Cor P. de Vries,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (170 additional authors not shown)
Abstract:
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture…
▽ More
The Crab nebula originated from a core-collapse supernova (SN) explosion observed in 1054 A.D. When viewed as a supernova remnant (SNR), it has an anomalously low observed ejecta mass and kinetic energy for an Fe-core collapse SN. Intensive searches were made for a massive shell that solves this discrepancy, but none has been detected. An alternative idea is that the SN1054 is an electron-capture (EC) explosion with a lower explosion energy by an order of magnitude than Fe-core collapse SNe. In the X-rays, imaging searches were performed for the plasma emission from the shell in the Crab outskirts to set a stringent upper limit to the X-ray emitting mass. However, the extreme brightness of the source hampers access to its vicinity. We thus employed spectroscopic technique using the X-ray micro-calorimeter onboard the Hitomi satellite. By exploiting its superb energy resolution, we set an upper limit for emission or absorption features from yet undetected thermal plasma in the 2-12 keV range. We also re-evaluated the existing Chandra and XMM-Newton data. By assembling these results, a new upper limit was obtained for the X-ray plasma mass of <~ 1Mo for a wide range of assumed shell radius, size, and plasma temperature both in and out of the collisional equilibrium. To compare with the observation, we further performed hydrodynamic simulations of the Crab SNR for two SN models (Fe-core versus EC) under two SN environments (uniform ISM versus progenitor wind). We found that the observed mass limit can be compatible with both SN models if the SN environment has a low density of <~ 0.03 cm-3 (Fe core) or <~ 0.1 cm-3 (EC) for the uniform density, or a progenitor wind density somewhat less than that provided by a mass loss rate of 10-5 Mo yr-1 at 20 km s-1 for the wind environment.
△ Less
Submitted 4 July, 2017; v1 submitted 30 June, 2017;
originally announced July 2017.
-
Hitomi constraints on the 3.5 keV line in the Perseus galaxy cluster
Authors:
Hitomi Collaboration,
Felix A. Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Lorella Angelini,
Keith A. Arnaud,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall W. Bautz,
Roger D. Blandford,
Laura W. Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward M. Cackett,
Maria Chernyakova,
Meng P. Chiao,
Paolo Coppi,
Elisa Costantini,
Jelle de Plaa,
Jan-Willem den Herder,
Chris Done,
Tadayasu Dotani
, et al. (193 additional authors not shown)
Abstract:
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-New…
▽ More
High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-Newton signal from the large cluster sample under the dark matter decay scenario is too faint to be detectable in the Hitomi data. However, the previously reported 3.5 keV flux from Perseus was anomalously high compared to the sample-based prediction. We find no unidentified line at the reported high flux level. Taking into account the XMM measurement uncertainties for this region, the inconsistency with Hitomi is at a 99% significance for a broad dark-matter line and at 99.7% for a narrow line from the gas. We do not find anomalously high fluxes of the nearby faint K line or the Ar satellite line that were proposed as explanations for the earlier 3.5 keV detections. We do find a hint of a broad excess near the energies of high-n transitions of Sxvi (E=3.44 keV rest-frame) -- a possible signature of charge exchange in the molecular nebula and another proposed explanation for the unidentified line. While its energy is consistent with XMM pn detections, it is unlikely to explain the MOS signal. A confirmation of this interesting feature has to wait for a more sensitive observation with a future calorimeter experiment.
△ Less
Submitted 27 February, 2017; v1 submitted 25 July, 2016;
originally announced July 2016.
-
The Quiescent Intracluster Medium in the Core of the Perseus Cluster
Authors:
Hitomi Collaboration,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steven W. Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Marc Audard,
Hisamitsu Awaki,
Magnus Axelsson,
Aya Bamba,
Marshall Bautz,
Roger Blandford,
Laura Brenneman,
Gregory V. Brown,
Esra Bulbul,
Edward Cackett,
Maria Chernyakova,
Meng Chiao,
Paolo Coppi,
Elisa Costantini,
Jelle de Plaa,
Jan-Willem den Herder,
Chris Done
, et al. (191 additional authors not shown)
Abstract:
Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injectio…
▽ More
Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injection by the central supermassive black hole and the use of hydrostatic equilibrium for the determination of cluster masses. X-rays from the core of the Perseus cluster are emitted by the 50 million K diffuse hot plasma filling its gravitational potential well. The Active Galactic Nucleus of the central galaxy NGC1275 is pumping jetted energy into the surrounding intracluster medium, creating buoyant bubbles filled with relativistic plasma. These likely induce motions in the intracluster medium and heat the inner gas preventing runaway radiative cooling; a process known as Active Galactic Nucleus Feedback. Here we report on Hitomi X-ray observations of the Perseus cluster core, which reveal a remarkably quiescent atmosphere where the gas has a line-of-sight velocity dispersion of 164+/-10 km/s in a region 30-60 kpc from the central nucleus. A gradient in the line-of-sight velocity of 150+/-70 km/s is found across the 60 kpc image of the cluster core. Turbulent pressure support in the gas is 4% or less of the thermodynamic pressure, with large scale shear at most doubling that estimate. We infer that total cluster masses determined from hydrostatic equilibrium in the central regions need little correction for turbulent pressure.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
X-ray Performance of Back-Side Illuminated Type of Kyoto's X-ray Astronomical SOI Pixel Sensor, XRPIX
Authors:
Makoto Itou,
Takeshi Go Tsuru,
Takaaki Tanaka,
Ayaki Takeda,
Hideaki Matsumura,
Shunichi Ohmura,
Shinya Nakashima,
Yasuo Arai,
Koji Mori,
Ryota Takenaka,
Yusuke Nishioka,
Takayoshi Kohmura,
Koki Tamasawa,
Craig Tindall
Abstract:
We have been developing X-ray SOI pixel Sensors, called "XRPIX", for future X-ray astronomy satellites that enable us to observe in the wide energy band of 0.5-40 keV. Since XRPIXs have the circuitry layer with a thickness of about 8 μm in the front side of the sensor, it is impossible to detect low energy X-rays with a front-illuminated type. So, we have been developing back-illuminated type of X…
▽ More
We have been developing X-ray SOI pixel Sensors, called "XRPIX", for future X-ray astronomy satellites that enable us to observe in the wide energy band of 0.5-40 keV. Since XRPIXs have the circuitry layer with a thickness of about 8 μm in the front side of the sensor, it is impossible to detect low energy X-rays with a front-illuminated type. So, we have been developing back-illuminated type of XRPIX with a less 1 μm dead layer in the back-side, which enables the sensitivity to reach 0.5 keV. We produced two types of back-side illuminated (BI) XRPIXs, one of which is produced in "Pizza process" which LBNL developed and the other is processed in the ion implantation and laser annealing. We irradiated both of the BI-XRPIXs with soft X-ray and investigate soft X-ray performance of them. We report results from soft X-ray evaluation test of the device.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Improvement of Spectroscopic Performance using a Charge-sensitive Amplifier Circuit for an X-Ray Astronomical SOI Pixel Detector
Authors:
Ayaki Takeda,
Takeshi Go Tsuru,
Takaaki Tanaka,
Hiroyuki Uchida,
Hideaki Matsumura,
Yasuo Arai,
Koji Mori,
Yusuke Nishioka,
Ryota Takenaka,
Takayoshi Kohmura,
Shinya Nakashima,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Hiroki Kamehama,
Sumeet Shrestha
Abstract:
We have been developing monolithic active pixel sensors series, named "XRPIX," based on the silicon-on-insulator (SOI) pixel technology, for future X-ray astronomical satellites. The XRPIX series offers high coincidence time resolution ({\rm \sim}1 {\rm μ}s), superior readout time ({\rm \sim}10 {\rm μ}s), and a wide energy range (0.5--40 keV). In the previous study, we successfully demonstrated X-…
▽ More
We have been developing monolithic active pixel sensors series, named "XRPIX," based on the silicon-on-insulator (SOI) pixel technology, for future X-ray astronomical satellites. The XRPIX series offers high coincidence time resolution ({\rm \sim}1 {\rm μ}s), superior readout time ({\rm \sim}10 {\rm μ}s), and a wide energy range (0.5--40 keV). In the previous study, we successfully demonstrated X-ray detection by event-driven readout of XRPIX2b. We here report recent improvements in spectroscopic performance. We successfully increased the gain and reduced the readout noise in XRPIX2b by decreasing the parasitic capacitance of the sense-node originated in the buried p-well (BPW). On the other hand, we found significant tail structures in the spectral response due to the loss of the charge collection efficiency when a small BPW is employed. Thus, we increased the gain in XRPIX3b by introducing in-pixel charge sensitive amplifiers instead of having even smaller BPW. We finally achieved the readout noise of 35 e{\rm ^{-}} (rms) and the energy resolution of 320 eV (FWHM) at 6 keV without significant loss of the charge collection efficiency.
△ Less
Submitted 21 March, 2016;
originally announced March 2016.
-
Wide-Field MAXI: soft X-ray transient monitor
Authors:
Makoto Arimoto,
Nobuyuki Kawai,
Yoichi Yatsu,
Hiroshi Tomida,
Shiro Ueno,
Masashi Kimura,
Tatehiro Mihara,
Motoko Serino,
Mikio Morii,
Hiroshi Tsunemi,
Atsumasa Yoshida,
Takanori Sakamoto,
Takayoshi Kohmura,
Hitoshi Negoro,
Yoshihiro Ueda,
Yohko Tsuboi,
Ken Ebisawa
Abstract:
Wide-Field MAXI (WF-MAXI: Wide-Field Monitor of All-sky X-ray Image) is a proposed mission to detect and localize X-ray transients including electro-magnetic counterparts of gravitational-wave events such as gamma-ray bursts and supernovae etc., which are expected to be directly detected for the first time in late 2010's by the next generation gravitational telescopes such as Advanced LIGO and KAG…
▽ More
Wide-Field MAXI (WF-MAXI: Wide-Field Monitor of All-sky X-ray Image) is a proposed mission to detect and localize X-ray transients including electro-magnetic counterparts of gravitational-wave events such as gamma-ray bursts and supernovae etc., which are expected to be directly detected for the first time in late 2010's by the next generation gravitational telescopes such as Advanced LIGO and KAGRA. The most distinguishing characteristics of WF-MAXI are a wide energy range from 0.7 keV to 1 MeV and a large field of view (~25 % of the entire sky), which are realized by two main instruments: (i) Soft X-ray Large Solid Angle Camera (SLC) which consists of four pairs of crisscross coded aperture cameras using CCDs as one-dimensional fast-readout detectors covering 0.7 - 12 keV and (ii) Hard X-ray Monitor (HXM) which is a multi-channel array of crystal scintillators coupled with avalanche photo-diodes covering 20 keV - 1 MeV.
△ Less
Submitted 12 February, 2015;
originally announced February 2015.
-
The ASTRO-H X-ray Astronomy Satellite
Authors:
Tadayuki Takahashi,
Kazuhisa Mitsuda,
Richard Kelley,
Felix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steve Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Makoto Asai,
Marc Audard,
Hisamitsu Awaki,
Philipp Azzarello,
Chris Baluta,
Aya Bamba,
Nobutaka Bando,
Marshall Bautz,
Thomas Bialas,
Roger Blandford,
Kevin Boyce,
Laura Brenneman,
Greg Brown,
Edward Cackett,
Edgar Canavan
, et al. (228 additional authors not shown)
Abstract:
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-ra…
▽ More
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. The simultaneous broad band pass, coupled with the high spectral resolution of Delta E < 7 eV of the micro-calorimeter, will enable a wide variety of important science themes to be pursued. ASTRO-H is expected to provide breakthrough results in scientific areas as diverse as the large-scale structure of the Universe and its evolution, the behavior of matter in the gravitational strong field regime, the physical conditions in sites of cosmic-ray acceleration, and the distribution of dark matter in galaxy clusters at different redshifts.
△ Less
Submitted 3 December, 2014;
originally announced December 2014.
-
ASTRO-H White Paper - Accreting Pulsars, Magnetars, and Related Sources
Authors:
S. Kitamoto,
T. Enoto,
S. Safi-Harb,
K. Pottschmidt,
C. Ferrigno,
M. Chernyakova,
T. Hayashi,
N. Hell,
K. Kaneko,
D. Khangulyan,
T. Kohmura,
H. Krimm,
K. Makishima,
T. Nakano,
H. Odaka,
M. Ohno,
M. Sasano,
S. Sugita,
Y. Terada,
T. Yasuda,
T. Yuasa
Abstract:
As the endpoints of massive star evolution, neutron stars are enigmatic celestial objects characterized by extremely dense and exotic nuclear matter, magnetospheres with positrons (antimatter), rapid rotation and ultra-strong magnetic fields. Such an extreme environment has provided an accessible astrophysical laboratory to study physics under conditions unattainable on Earth and to tackle a range…
▽ More
As the endpoints of massive star evolution, neutron stars are enigmatic celestial objects characterized by extremely dense and exotic nuclear matter, magnetospheres with positrons (antimatter), rapid rotation and ultra-strong magnetic fields. Such an extreme environment has provided an accessible astrophysical laboratory to study physics under conditions unattainable on Earth and to tackle a range of fundamental questions related to: the aftermath of stellar evolution and the powerful explosions of massive stars, the equation of state and physics of some of the most exotic and magnetic stars in the Universe, the workings of the most powerful particle accelerators in our Galaxy and beyond, and the sources of gravitational waves that are yet to be detected. Recent observations revealed a great diversity of neutron stars, including ultra-strongly magnetized pulsars, referred to as "magnetars", and unusual types of accreting X-ray pulsars. In this white paper, we highlight the prospects of the upcoming X-ray mission, ASTRO-H, in studying these highly magnetized neutron stars.
△ Less
Submitted 2 December, 2014;
originally announced December 2014.
-
ASTRO-H White Paper - Low-mass X-ray Binaries
Authors:
C. Done,
M. Tsujimoto,
E. Cackett,
J. W. den Herder,
T. Dotani,
T. Enoto,
C. Ferrigno,
T. Kallman,
T. Kohmura,
P. Laurent,
J. Miller,
S. Mineshige,
H. Mori,
K. Nakazawa,
F. Paerels,
S. Sakurai,
Y. Soong,
S. Sugita,
H. Takahashi,
T. Tamagawa,
Y. Tanaka,
Y. Terada,
S. Uno
Abstract:
There is still 10-20% uncertainty on the neutron star (NS) mass-radius relation. These uncertainties could be reduced by an order of magnitude through an unambiguous measure of M/R from the surface redshift of a narrow line, greatly constraining the Equation of State for ultra-dense material. It is possible that the SXS on ASTRO-H can detect this from an accreting neutron star with low surface vel…
▽ More
There is still 10-20% uncertainty on the neutron star (NS) mass-radius relation. These uncertainties could be reduced by an order of magnitude through an unambiguous measure of M/R from the surface redshift of a narrow line, greatly constraining the Equation of State for ultra-dense material. It is possible that the SXS on ASTRO-H can detect this from an accreting neutron star with low surface velocity in the line of sight i.e. either low inclination or low spin. Currently there is only one known low inclination LMXB, Ser X-1, and one known slow spin LMXB, J17480-2446 in Terzan 5. Ser X-1 is a persistent source which is always in the soft state (banana branch), where the accreting material should form a equatorial belt around the neutron star. A pole-on view should then allow the NS surface to be seen directly. A 100 ks observation should allow us to measure M/R if there are any heavy elements in the photosphere at the poles. Conversely, J17480-2446 in Terzan 5 is a transient accretion powered millisecond pulsar, where the accreting material is collimated onto the magnetic pole in the hard (island) state (L_x < 0.1 L_Edd). The hotspot where the shock illuminates the NS surface is clearly seen in this state. A 100 ks ToO observation of this (or any other similarly slow spin system) in this state, may again allow the surface redshift to be directly measured. (abstract continues)
△ Less
Submitted 2 December, 2014;
originally announced December 2014.
-
Development and Performance of Kyoto's X-ray Astronomical SOI pixel (SOIPIX) sensor
Authors:
Takeshi G. Tsuru,
Hideaki Matsumura,
Ayaki Takeda,
Takaaki Tanaka,
Shinya Nakashima,
Yasuo Arai,
Koji Mori,
Ryota Takenaka,
Yusuke Nishioka,
Takayoshi Kohmura,
Takaki Hatsui,
Takashi Kameshima,
Kyosuke Ozaki,
Yoshiki Kohmura,
Tatsuya Wagai,
Dai Takei,
Shoji Kawahito,
Keiichiro Kagawa,
Keita Yasutomi,
Hiroki Kamehama,
Sumeet Shrestha
Abstract:
We have been developing monolithic active pixel sensors, known as Kyoto's X-ray SOIPIXs, based on the CMOS SOI (silicon-on-insulator) technology for next-generation X-ray astronomy satellites. The event trigger output function implemented in each pixel offers microsecond time resolution and enables reduction of the non-X-ray background that dominates the high X-ray energy band above 5--10 keV. A f…
▽ More
We have been developing monolithic active pixel sensors, known as Kyoto's X-ray SOIPIXs, based on the CMOS SOI (silicon-on-insulator) technology for next-generation X-ray astronomy satellites. The event trigger output function implemented in each pixel offers microsecond time resolution and enables reduction of the non-X-ray background that dominates the high X-ray energy band above 5--10 keV. A fully depleted SOI with a thick depletion layer and back illumination offers wide band coverage of 0.3--40 keV. Here, we report recent progress in the X-ray SOIPIX development. In this study, we achieved an energy resolution of 300~eV (FWHM) at 6~keV and a read-out noise of 33~e- (rms) in the frame readout mode, which allows us to clearly resolve Mn-K$α$ and K$β$. Moreover, we produced a fully depleted layer with a thickness of $500~{\rm μm}$. The event-driven readout mode has already been successfully demonstrated.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
Proton Radiation Damage Experiment on P-Channel CCD for an X-ray CCD camera onboard the Astro-H satellite
Authors:
Koji Mori,
Yusuke Nishioka,
Satoshi Ohura,
Yoshiaki Koura,
Makoto Yamauchi,
Hiroshi Nakajima,
Shutaro Ueda,
Hiroaki Kan,
Naohisa Anabuki,
Ryo Nagino,
Kiyoshi Hayashida,
Hiroshi Tsunemi,
Takayoshi Kohmura,
Shoma Ikeda,
Hiroshi Murakami,
Masanobu Ozaki,
Tadayasu Dotani,
Yukie Maeda,
Kenshi Sagara
Abstract:
We report on a proton radiation damage experiment on P-channel CCD newly developed for an X-ray CCD camera onboard the Astro-H satellite. The device was exposed up to 10^9 protons cm^{-2} at 6.7 MeV. The charge transfer inefficiency (CTI) was measured as a function of radiation dose. In comparison with the CTI currently measured in the CCD camera onboard the Suzaku satellite for 6 years, we confir…
▽ More
We report on a proton radiation damage experiment on P-channel CCD newly developed for an X-ray CCD camera onboard the Astro-H satellite. The device was exposed up to 10^9 protons cm^{-2} at 6.7 MeV. The charge transfer inefficiency (CTI) was measured as a function of radiation dose. In comparison with the CTI currently measured in the CCD camera onboard the Suzaku satellite for 6 years, we confirmed that the new type of P-channel CCD is radiation tolerant enough for space use. We also confirmed that a charge-injection technique and lowering the operating temperature efficiently work to reduce the CTI for our device. A comparison with other P-channel CCD experiments is also discussed.
△ Less
Submitted 23 June, 2013;
originally announced June 2013.
-
The ASTRO-H X-ray Observatory
Authors:
Tadayuki Takahashi,
Kazuhisa Mitsuda,
Richard Kelley,
Henri AartsFelix Aharonian,
Hiroki Akamatsu,
Fumie Akimoto,
Steve Allen,
Naohisa Anabuki,
Lorella Angelini,
Keith Arnaud,
Makoto Asai,
Marc Audard,
Hisamitsu Awaki,
Philipp Azzarello,
Chris Baluta,
Aya Bamba,
Nobutaka Bando,
Mark Bautz,
Roger Blandford,
Kevin Boyce,
Greg Brown,
Ed Cackett,
Maria Chernyakova,
Paolo Coppi,
Elisa Costantini
, et al. (198 additional authors not shown)
Abstract:
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer s…
▽ More
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.
△ Less
Submitted 16 October, 2012;
originally announced October 2012.