-
Revealing the broad iron Kalpha line in Cygnus X-1 through simultaneous XMM-Newton, RXTE, and INTEGRAL observations
Authors:
Refiz Duro,
Thomas Dauser,
Victoria Grinberg,
Ivica Miškovičová,
Jérôme Rodriguez,
John Tomsick,
Manfred Hanke,
Katja Pottschmidt,
Michael A. Nowak,
Sonja Kreykenbohm,
Marion Cadolle Bel,
Arash Bodaghee,
Anne Lohfink,
Christopher S. Reynolds,
Eckhard Kendziorra,
Marcus G. F. Kirsch,
Rüdiger Staubert,
Jörn Wilms
Abstract:
We report on the analysis of the broad Fe Kalpha line feature of Cygnus X-1 in the spectra of four simultaneous hard intermediate state observations made with the X-ray Multiple Mirror mission (XMM-Newton), the Rossi X-ray Timing Explorer (RXTE), and the International Gamma-Ray Astrophysics Laboratory (INTEGRAL). The high quality of the XMM-Newton data taken in the Modified Timing Mode of the EPIC…
▽ More
We report on the analysis of the broad Fe Kalpha line feature of Cygnus X-1 in the spectra of four simultaneous hard intermediate state observations made with the X-ray Multiple Mirror mission (XMM-Newton), the Rossi X-ray Timing Explorer (RXTE), and the International Gamma-Ray Astrophysics Laboratory (INTEGRAL). The high quality of the XMM-Newton data taken in the Modified Timing Mode of the EPIC-pn camera provides a great opportunity to investigate the broadened Fe Kalpha reflection line at 6.4keV with a very high signal to noise ratio. The 4-500keV energy range is used to constrain the underlying continuum and the reflection at higher energies. We first investigate the data by applying a phenomenological model that consists of the sum of an exponentially cutoff power law and relativistically smeared reflection. Additionally, we apply a more physical approach and model the irradiation of the accretion disk directly from the lamp post geometry. All four observations show consistent values for the black hole parameters with a spin of $a\sim 0.9$, in agreement with recent measurements from reflection and disk continuum fitting. The inclination is found to be $i\sim30^\circ$, consistent with the orbital inclination and different from inclination measurements made during the soft state, which show a higher inclination. We speculate that the difference between the inclination measurements is due to changes in the inner region of the accretion disk.
△ Less
Submitted 28 February, 2016;
originally announced February 2016.
-
The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
Authors:
A. Martin-Carrillo,
M. G. F. Kirsch,
I. Caballero,
M. J. Freyberg,
A. Ibarra,
E. Kendziorra,
U. Lammers,
K. Mukerjee,
G. Schönherr,
M. Stuhlinger,
R. D. Saxton,
R. Staubert,
S. Suchy,
A. Wellbrock,
N. Webb,
M. Guainazzi
Abstract:
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-…
▽ More
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with χ^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.
△ Less
Submitted 4 April, 2012;
originally announced April 2012.
-
The broad iron Kalpha line of Cygnus X-1 as seen by XMM-Newton in the EPIC-pn modified timing mode
Authors:
R. Duro,
T. Dauser,
J. Wilms,
K. Pottschmidt,
M. A. Nowak,
S. Fritz,
E. Kendziorra,
M. G. F. Kirsch,
C. S. Reynolds,
R. Staubert
Abstract:
We present the analysis of the broadened, flourescent iron Kalpha line in simultaneous XMM-Newton and RXTE data from the black hole Cygnus X-1. The XMM-Newton data were taken in a modified version of the timing mode of the EPIC-pn camera. In this mode the lower energy threshold of the instrument is increased to 2.8 keV to avoid telemetry drop outs due to the brightness of the source, while at the…
▽ More
We present the analysis of the broadened, flourescent iron Kalpha line in simultaneous XMM-Newton and RXTE data from the black hole Cygnus X-1. The XMM-Newton data were taken in a modified version of the timing mode of the EPIC-pn camera. In this mode the lower energy threshold of the instrument is increased to 2.8 keV to avoid telemetry drop outs due to the brightness of the source, while at the same time preserving the signal-to-noise ratio in the Fe Kalpha band. We find that the best-fit spectrum consists of the sum of an exponentially cut off power-law and relativistically smeared, ionized reflection. The shape of the broadened Fe Kalpha feature is due to strong Compton broadening combined with relativistic broadening. Assuming a standard, thin accretion disk, the black hole is close to rotating maximally.
△ Less
Submitted 4 August, 2011;
originally announced August 2011.
-
Thermal emission, shock modification, and X-ray emitting ejecta in SN 1006
Authors:
M. Miceli,
F. Bocchino,
D. Iakubovskyi,
S. Orlando,
I. Telezhinsky,
M. G. F. Kirsch,
O. Petruk,
G. Dubner,
G. Castelletti
Abstract:
Efficient particle acceleration can modify the structure of supernova remnants. In this context we present the results of the combined analysis of the XMM-Newton EPIC archive observations of SN 1006. We aim at describing the spatial distribution of the physical and chemical properties of the X-ray emitting plasma at the shock front. We investigate the contribution of thermal and non-thermal emis…
▽ More
Efficient particle acceleration can modify the structure of supernova remnants. In this context we present the results of the combined analysis of the XMM-Newton EPIC archive observations of SN 1006. We aim at describing the spatial distribution of the physical and chemical properties of the X-ray emitting plasma at the shock front. We investigate the contribution of thermal and non-thermal emission to the X-ray spectrum at the rim of the remnant to study how the acceleration processes affect the X-ray emitting plasma. We perform a spatially resolved spectral analysis on a set of regions covering the whole rim of the shell and we exploit the results of the spectral analysis to produce a count-rate image of the "pure" thermal emission of SN 1006 in the 0.5-0.8 keV energy band (subtracting the non-thermal contribution). This image significantly differs from the total image in the same band, specially near the bright limbs. We find that thermal X-ray emission can be associated with the ejecta and we study the azimuthal variation of their physical and chemical properties finding anisotropies in temperature and chemical composition. Thanks to our thermal image we trace the position of the contact discontinuity over the whole shell and we compare it with that expected from 3-D MHD models of SNRs with unmodified shock. We conclude that the shock is modified everywhere in the rim and that the aspect angle between the interstellar magnetic field and the line of sight is significantly lower than 90 degrees
△ Less
Submitted 19 March, 2009;
originally announced March 2009.
-
Aspect angle for interstellar magnetic field in SN 1006
Authors:
O. Petruk,
G. Dubner,
G. Castelletti,
F. Bocchino,
D. Iakubovskyi,
M. G. F. Kirsch,
M. Miceli,
S. Orlando,
I. Telezhinsky
Abstract:
A number of important processes taking place around strong shocks in supernova remnants (SNRs) depend on the shock obliquity. The measured synchrotron flux is a function of the aspect angle between interstellar magnetic field (ISMF) and the line of sight. Thus a model of non-thermal emission from SNRs should account for the orientation of the ambient magnetic field. We develop a new method for t…
▽ More
A number of important processes taking place around strong shocks in supernova remnants (SNRs) depend on the shock obliquity. The measured synchrotron flux is a function of the aspect angle between interstellar magnetic field (ISMF) and the line of sight. Thus a model of non-thermal emission from SNRs should account for the orientation of the ambient magnetic field. We develop a new method for the estimation of the aspect angle, based on the comparison between observed and synthesized radio maps of SNRs, making different assumptions about the dependence of electron injection efficiency on the shock obliquity. The method uses the azimuthal profile of radio surface brightness as a probe for orientation of ambient magnetic field because it is almost insensitive to the downstream distribution of magnetic field and emitting electrons. We apply our method to a new radio image of SN 1006 produced on the basis of archival VLA and Parkes data. The image recovers emission from all spatial structures with angular scales from few arcseconds to 15 arcmin. We explore different models of injection efficiency and find the following best-fitting values for the aspect angle of SN 1006: phi=70 +/- 4.2 deg if the injection is isotropic, phi=64 +/- 2.8 deg for quasi-perpendicular injection (SNR has an equatorial belt in both cases) and phi=11 +/- 0.8 deg for quasi-parallel injection (polar-cap model of SNR). In the last case, SN 1006 is expected to have a centrally-peaked morphology contrary to what is observed. Therefore, our analysis provides some indication against the quasi-parallel injection model.
△ Less
Submitted 14 November, 2008;
originally announced November 2008.
-
The XMM-Newton view of the Crab
Authors:
M. G. F. Kirsch,
G. Schoenherr,
E. Kendziorra,
M. J. Freyberg,
M. Martin,
J. Wilms,
K. Mukerjee,
M. G. Breitfellner,
M. J. S. Smith,
R. Staubert
Abstract:
We discuss the current X-ray view of the Crab Nebula and Pulsar, summarising our analysis of observations of the source with the EPIC-pn camera on board the XMM-Newton observatory. Different modes of EPIC-pn were combined in order to yield a complete scenario of the spectral properties of the Crab resolved in space and time (pulse phase). In addition we give a description of the special EPIC-pn…
▽ More
We discuss the current X-ray view of the Crab Nebula and Pulsar, summarising our analysis of observations of the source with the EPIC-pn camera on board the XMM-Newton observatory. Different modes of EPIC-pn were combined in order to yield a complete scenario of the spectral properties of the Crab resolved in space and time (pulse phase). In addition we give a description of the special EPIC-pn Burst mode and guidance for data reduction in that mode.
We analysed spectra for the nebula and pulsar separately in the 0.6-12.0 keV energy band. All data were processed with the SAS 6.0.0 XMM-Newton Scientific Analysis System package; models were fitted to the data with XSPEC 11. The high time resolution of EPIC-pn in its Burst mode (7 micros) was used for a phase resolved analysis of the pulsar spectrum, after determination of the period with epoch folding techniques. Data from the Small Window mode were processed and corrected for pile-up allowing for spectroscopy simultaneously resolved in space and time.
The spatial variation of the spectrum over the entire region of the Crab shows a gradual spectral softening from the inner pulsar region to the outer nebula region with a variation in photon index, Gamma, from 2.0 to 2.4. Pulse phase resolved spectroscopy of the Crab Pulsar reveals a phase dependent modulation of the photon index in form of a significant hardening of the spectrum in the inter-peak phase from Gamma =1.7 during the pulse peak to Gamma =1.5.
△ Less
Submitted 5 April, 2006;
originally announced April 2006.
-
Status of the XMM-Newton cross-calibration with SASv6.5.0
Authors:
M. Stuhlinger,
B. Altieri,
D. Baskill,
K. Dennerl,
M. P. Esquej,
M. Freyberg,
F. Haberl,
J. W. den Herder,
J. Kaastra,
M. G. F. Kirsch,
L. Metcalfe,
A. M. T. Pollock,
A. M. Read,
R. D. Saxton,
S. Sembay,
M. J. S. Smith,
A. Talavera,
J. Vink,
C. de Vries
Abstract:
Further achievements of the XMM-Newton cross-calibration - XMM internal as well as with other X-ray missions - are presented. We explain the major changes in the new version SASv6.5 of the XMM-Newton science analysis system. The current status of the cross-calibration of the three EPIC cameras is shown. Using a large sample of blazars, the pn energy redistribution at low energy could be further…
▽ More
Further achievements of the XMM-Newton cross-calibration - XMM internal as well as with other X-ray missions - are presented. We explain the major changes in the new version SASv6.5 of the XMM-Newton science analysis system. The current status of the cross-calibration of the three EPIC cameras is shown. Using a large sample of blazars, the pn energy redistribution at low energy could be further calibrated, correcting the overestimation of fluxes in the lowest energy regime. In the central CCDs of the MOSs, patches were identified at the bore-sight positions, leading to an underestimation of the low energy fluxes. The further improvement in the understanding of the cameras resulted in a good agreement of the EPIC instruments down to lowest energies. The latest release of the SAS software package already includes corrections for both effects as shown in several examples of different types of sources. Finally the XMM internal cross-calibration is completed by the presentation of the current cross-calibration status between EPIC and RGS instruments. Major efforts have been made in cross-calibrations with other X-ray missions, most importantly with Chandra, of course, but also with currently observing satellites like Swift.
△ Less
Submitted 14 November, 2005;
originally announced November 2005.
-
XMM-Newton (cross)-calibration
Authors:
M. G. F. Kirsch,
B. Altieri,
B. Chen,
F. Haberl,
L. Metcalfe,
A. M. T. Pollock,
A. M. Read,
R. D. Saxton,
S. Sembay,
M. J. S. Smith
Abstract:
ESA's large X-ray space observatory XMM-Newton is in its fifth year of operations. We give a general overview of the status of calibration of the five X-ray instruments and the Optical Monitor. A main point of interest in the last year became the cross-calibration between the instruments. A cross-calibration campaign started at the XMM-Newton Science Operation Centre at the European Space Astron…
▽ More
ESA's large X-ray space observatory XMM-Newton is in its fifth year of operations. We give a general overview of the status of calibration of the five X-ray instruments and the Optical Monitor. A main point of interest in the last year became the cross-calibration between the instruments. A cross-calibration campaign started at the XMM-Newton Science Operation Centre at the European Space Astronomy Centre in collaboration with the Instrument Principle Investigators provides a first systematic comparison of the X-ray instruments EPIC and RGS for various kind of sources making also an initial assessment in cross calibration with other X-ray observatories.
△ Less
Submitted 13 July, 2004;
originally announced July 2004.
-
Studies of orbital parameters and pulse profile of the accreting millisecond pulsar XTE J1807-294
Authors:
M. G. F. Kirsch,
K. Mukerjee,
M. G. Breitfellner,
S. Djavidnia,
M. J. Freyberg,
E. Kendziorra,
M. J. S. Smith
Abstract:
The accreting millisecond pulsar XTE J1807-294 was observed by XMM-Newton on March 22, 2003 after its discovery on February 21, 2003 by RXTE. The source was detected in its bright phase with an observed average count rate of 33.3 cts/s in the EPIC-pn camera in the 0.5-10 keV energy band (3.7 mCrab). Using the earlier established best-fit orbital period of 40.0741+/-0.0005 minutes from RXTE obser…
▽ More
The accreting millisecond pulsar XTE J1807-294 was observed by XMM-Newton on March 22, 2003 after its discovery on February 21, 2003 by RXTE. The source was detected in its bright phase with an observed average count rate of 33.3 cts/s in the EPIC-pn camera in the 0.5-10 keV energy band (3.7 mCrab). Using the earlier established best-fit orbital period of 40.0741+/-0.0005 minutes from RXTE observations and considering a circular binary orbit as first approximation, we derived a value of 4.8+/-0.1 lt-ms for the projected orbital radius of the binary system and an epoch of the orbital phase of MJD 52720.67415(16). The barycentric mean spin period of the pulsar was derived as 5.2459427+/-0.0000004 ms. The pulsar's spin-pulse profile showed a prominent (1.5 ms FWHM) pulse, with energy and orbital phase dependence in the amplitude and shape. The measured pulsed fraction in four energy bands was found to be 3.1+/-0.2 % (0.5-3.0 keV), 5.4+/-0.4 % (3.0-6.0 keV), 5.1+/-0.7 % (6.0-10.0 keV) and 3.7+/-0.2 % (0.5-10.0 keV), respectively. Studies of spin-profiles with orbital phase and energy showed significant increase in its pulsed fraction during the second observed orbit of the neutron star, gradually declining in the subsequent two orbits, which was associated with sudden but marginal increase in mass accretion. From our investigations of orbital parameters and estimation of other properties of this compact binary system, we conclude that XTE J1807-294 is very likely a candidate for a millisecond radio pulsar.
△ Less
Submitted 1 July, 2004;
originally announced July 2004.