Skip to main content

Showing 1–12 of 12 results for author: Kinion, D

  1. A search for non-virialized axionic dark matter

    Authors: J. Hoskins, J. Hwang, C. Martin, P. Sikivie, N. S. Sullivan, D. B. Tanner, M. Hotz, L. J Rosenberg, G. Rybka, A. Wagner, S. J. Asztalos, G. Carosi, C. Hagmann, D. Kinion, K. van Bibber, R. Bradley, J. Clarke

    Abstract: Cold dark matter in the Milky Way halo may have structure defined by flows with low velocity dispersion. The Axion Dark Matter eXperiment high resolution channel is especially sensitive to axions in such low velocity dispersion flows. Results from a combined power spectra analysis of the high resolution channel axion search are presented along with a discussion of the assumptions underlying such a… ▽ More

    Submitted 17 November, 2011; v1 submitted 19 September, 2011; originally announced September 2011.

    Comments: 4 pages, 4 figures, Accepted to be published in PRD Rapid Communications

  2. arXiv:1105.4203  [pdf, ps, other

    physics.ins-det astro-ph.CO hep-ex

    Design and performance of the ADMX SQUID-based microwave receiver

    Authors: S. J. Asztalos, G. Carosi, C. Hagmann, D. Kinion, K. van Bibber, M. Hotz, L. J Rosenberg, G. Rybka, A. Wagner, J. Hoskins, C. Martin, N. S. Sullivan, D. B. Tanner, R. Bradley, John Clarke

    Abstract: The Axion Dark Matter eXperiment (ADMX) was designed to detect ultra-weakly interacting relic axion particles by searching for their conversion to microwave photons in a resonant cavity positioned in a strong magnetic field. Given the extremely low expected axion-photon conversion power we have designed, built and operated a microwave receiver based on a Superconducting QUantum Interference Device… ▽ More

    Submitted 20 May, 2011; originally announced May 2011.

    Comments: 8 pages, 12 figures, Submitted to Nuclear Inst. and Methods in Physics Research, A

    Journal ref: Nuclear Inst. and Methods in Physics Research, A 656 (2011) pp. 39-44

  3. A Search for Hidden Sector Photons with ADMX

    Authors: A. Wagner, G. Rybka, M. Hotz, L. J Rosenberg, S. J. Asztalos, G. Carosi, C. Hagmann, D. Kinion, K. van Bibber, J. Hoskins, C. Martin, P. Sikivie, D. B. Tanner, R. Bradley, J. Clarke

    Abstract: Hidden U(1) gauge symmetries are common to many extensions of the Standard Model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with Standard Model photons, providing a means for electromagnetic power to pass through conducting barriers. The ADMX detector was used to search for hidden vector bosons originating in an emitter cavity driven with… ▽ More

    Submitted 28 October, 2010; v1 submitted 21 July, 2010; originally announced July 2010.

    Comments: 4 pages, 4 figures, published in PRL

    Journal ref: Phys.Rev.Lett.105:171801,2010

  4. A Search for Scalar Chameleons with ADMX

    Authors: G. Rybka, M. Hotz, L. J Rosenberg, S. J. Asztalos, G. Carosi, C. Hagmann, D. Kinion, K. van Bibber, J. Hoskins, C. Martin, P. Sikivie, D. B. Tanner, R. Bradley, J. Clarke

    Abstract: Scalar fields with a "chameleon" property, in which the effective particle mass is a function of its local environment, are common to many theories beyond the standard model and could be responsible for dark energy. If these fields couple weakly to the photon, they could be detectable through the "afterglow" effect of photon-chameleon-photon transitions. The ADMX experiment was used in the first c… ▽ More

    Submitted 28 April, 2010; originally announced April 2010.

    Comments: 4 pages, 3 figures

    Journal ref: Phys.Rev.Lett.105:051801,2010

  5. A SQUID-based microwave cavity search for dark-matter axions

    Authors: The ADMX Collaboration, S. J. Asztalos, G. Carosi, C. Hagmann, D. Kinion, K. van Bibber, M. Hotz, L. Rosenberg, G. Rybka, J. Hoskins, J. Hwang, P. Sikivie, D. B. Tanner, R. Bradley, J. Clarke

    Abstract: Axions in the micro eV mass range are a plausible cold dark matter candidate and may be detected by their conversion into microwave photons in a resonant cavity immersed in a static magnetic field. The first result from such an axion search using a superconducting first-stage amplifier (SQUID) is reported. The SQUID amplifier, replacing a conventional GaAs field-effect transistor amplifier, succ… ▽ More

    Submitted 30 October, 2009; originally announced October 2009.

    Comments: 4 pages, 5 figures, submitted to PRL

    Journal ref: Phys.Rev.Lett.104:041301,2010

  6. arXiv:astro-ph/0603108  [pdf, ps, other

    astro-ph hep-ex hep-ph

    A High Resolution Search for Dark-Matter Axions

    Authors: L. D. Duffy, P. Sikivie, D. B. Tanner, S. J. Asztalos, C. Hagmann, D. Kinion, L. J Rosenberg, K. van Bibber, D. B. Yu, R. F. Bradley

    Abstract: We have performed a high resolution search for galactic halo axions in cold flows using a microwave cavity detector. The analysis procedure and other details of this search are described. No axion signal was found in the mass range 1.98-2.17 micro-eV. We place upper limits on the density of axions in local discrete flows based on this result.

    Submitted 4 March, 2006; originally announced March 2006.

    Comments: 11 pages, 10 figures, 2 tables

    Report number: UFIFT-HEP-06-6

    Journal ref: Phys.Rev.D74:012006,2006

  7. Results of a Search for Cold Flows of Dark Matter Axions

    Authors: L. Duffy, P. Sikivie, D. B. Tanner, S. Asztalos, C. Hagmann, D. Kinion, L. J Rosenberg, K. van Bibber, D. Yu, R. F. Bradley

    Abstract: Theoretical arguments predict that the distribution of cold dark matter in spiral galaxies has peaks in velocity space associated with non-thermalized flows of dark matter particles. We searched for the corresponding peaks in the spectrum of microwave photons from axion to photon conversion in the cavity detector of dark matter axions. We found none and place limits on the density of any local f… ▽ More

    Submitted 11 May, 2005; originally announced May 2005.

    Comments: 5 pages, 3 figures

    Report number: UFIFT-HEP-05-08

    Journal ref: Phys.Rev.Lett.95:091304,2005

  8. An Improved RF Cavity Search for Halo Axions

    Authors: S. J. Asztalos, R. F. Bradley, L. Duffy, C. Hagmann, D. Kinion, D. M. Moltz, L. J Rosenberg, P. Sikivie, W. Stoeffl, N. S. Sullivan, D. B. Tanner, K. van Bibber, D. B. Yu

    Abstract: The axion is a hypothetical elementary particle and cold dark matter candidate. In this RF cavity experiment, halo axions entering a resonant cavity immersed in a static magnetic field convert into microwave photons, with the resulting photons detected by a low-noise receiver. The ADMX Collaboration presents new limits on the axion-to-photon coupling and local axion dark matter halo mass density… ▽ More

    Submitted 1 October, 2003; originally announced October 2003.

    Comments: 5 pages, submitted to Physical Review D rapid communications

    Journal ref: Phys.Rev.D69:011101,2004

  9. Experimental Constraints on the Axion Dark Matter Halo Density

    Authors: Stephen J. Asztalos, E. Daw, H. Peng, L. J Rosenberg, C. Hagmann, D. Kinion, W. Stoeffl, K. van Bibber, J. LaVeigne, P. Sikivie, N. S. Sullivan, D. B. Tanner, F. Nezrick, Michael S. Turner, D. M. Moltz

    Abstract: Most of the mass of the Milky Way galaxy is contributed by its halo, presumably in the form of non-interacting cold dark matter. The axion is a compelling cold dark matter candidate. We report results from a search which probes the local galactic halo axion density using the Sikivie RF cavity technique. Candidates over the frequency range 550$$ $\le$ f $\le$$$ 810 MHz (2.3$$ $μ$eV $\le$$$ m$_{a}… ▽ More

    Submitted 12 June, 2002; v1 submitted 11 April, 2001; originally announced April 2001.

    Comments: 10 pages (includes 3 figures)

    Journal ref: Astrophys.J. 571 (2002) L27-L30

  10. Results from a High-Sensitivity Search for Cosmic Axions

    Authors: C. Hagmann, D. Kinion, W. Stoeffl, K. van Bibber, E. Daw, H. Peng, Leslie J Rosenberg, J. LaVeigne, P. Sikivie, N. Sullivan, D. Tanner, F. Nezrick, Michael S. Turner, D. Moltz, J. Powell, N. Golubev

    Abstract: We report the first results of a high-sensitivity (10^{-23} Watt) search for light halo axions through their conversion to microwave photons. At 90 percent confidence we exclude a KSVZ axion of mass 2.9 x 10^{-6} eV to 3.3 x 10^{-6} eV as the dark matter in the halo of our Galaxy.

    Submitted 28 January, 1998; originally announced January 1998.

    Comments: 11 text pages, 4 figures (figures 2 and 3 combined), to be published in Physical Review Letters

    Report number: (MIT) LNS-97-275

    Journal ref: Phys.Rev.Lett. 80 (1998) 2043-2046

  11. First results from a second generation galactic axion experiment

    Authors: C. Hagmann, D. Kinion, W. Stoeffl, K. van Bibber, E. Daw, J. McBride, H. Peng, L. Rosenberg, H. Xin, J. Laveigne, P. Sikivie, N. Sullivan, D. Tanner, D. Moltz, F. Nezrick, M. Turner, N. Golubev, L. Kravchuk

    Abstract: We report first results from a large scale search for dark matter axions. The experiment probes axion masses of 1.3-13 micro-eV at a sensitivity which is about 50 times higher than previous pilot experiments. We have already scanned part of this mass range at a sensitivity better than required to see at least one generic axion model, the KSVZ axion. Data taking at full sensitivity commenced in F… ▽ More

    Submitted 3 July, 1996; originally announced July 1996.

    Comments: 4 pages with 4 embedded figures, Postscript, to be published in the Proceedings of the DM 96 conference held in Santa Monica, Feb. 14-16, 1996

    Report number: UCRL-JC-124162

    Journal ref: Nucl.Phys.Proc.Suppl. 51B (1996) 209-212

  12. arXiv:astro-ph/9508013  [pdf, ps

    astro-ph

    A 2nd generation cosmic axion experiment

    Authors: C. Hagmann, W. Stoeffl, K. van Bibber, E. Daw, D. Kinion, L. Rosenberg, P. Sikivie, N. Sullivan, D. Tanner, D. Moltz, F. Nezrick, M. Turner, N. Golubev, L. Kravchuk

    Abstract: An experiment is described to detect dark matter axions trapped in the halo of our galaxy. Galactic axions are converted into microwave photons via the Primakoff effect in a static background field provided by a superconducting magnet. The photons are collected in a high Q microwave cavity and detected by a low noise receiver. The axion mass range accessible by this experiment is 1.3-13 micro-eV… ▽ More

    Submitted 3 August, 1995; originally announced August 1995.

    Comments: Postscript, 6 pages, 4 figures; submitted to proceedings of: XXXth Recontres de Moriond, 'Dark Matter in Cosmology", Villars-sur-Ollon, Switzerland, Jan 21-28, 1995

    Report number: UCRL-JC-120869