-
Data processing of Visible Emission Line Coronagraph Onboard ADITYA L1
Authors:
Muthu Priyal,
Jagdev Singh,
B. Raghavendra Prasad,
Chavali Sumana,
Varun Kumar,
Shalabh Mishra,
S. N. Venkata,
G. Sindhuja,
K. Sasikumar Raja,
Amit Kumar,
Sanal krishnan,
Bhavana S. Hegde,
D. Utkarsha,
Natarajan Venkatasubramanian,
Pawankumar Somasundram,
S. Nagabhushana,
PU. Kamath,
S. Kathiravan,
T. Vishnu Mani,
Suresh Basavaraju,
Rajkumar Chavan,
P. Vemareddy,
B. Ravindra,
S. P. Rajaguru,
K. Nagaraju
, et al. (6 additional authors not shown)
Abstract:
ADITYA-L1 is India's first dedicated mission to observe the sun and its atmosphere from a halo orbit around L1 point. Visible emission line coronagraph (VELC) is the prime payload on board at Aditya-L1 to observe the sun's corona. VELC is designed as an internally occulted reflective coronagraph to meet the observational requirements of wide wavelength band and close to the solar limb (1.05 Ro). I…
▽ More
ADITYA-L1 is India's first dedicated mission to observe the sun and its atmosphere from a halo orbit around L1 point. Visible emission line coronagraph (VELC) is the prime payload on board at Aditya-L1 to observe the sun's corona. VELC is designed as an internally occulted reflective coronagraph to meet the observational requirements of wide wavelength band and close to the solar limb (1.05 Ro). Images of the solar corona in continuum and spectra in three emission lines 5303Å [Fe xiv], 7892Å [Fe xi] and 10747 [Fe xiii] obtained with high cadence to be analyzed using software algorithms automatically. A reasonable part of observations will be made in synoptic mode, those, need to be analyzed and results made available for public use. The procedure involves the calibration of instrument and detectors, converting the images into fits format, correcting the images and spectra for the instrumental effects, align the images etc. Then, develop image processing algorithms to detect the occurrence of energetic events using continuum images. Also derive physical parameters, such as temperature and velocity structure of solar corona using emission line observations. Here, we describe the calibration of detectors and the development of software algorithms to detect the occurrence of CMEs and analyze the spectroscopic data.
△ Less
Submitted 6 July, 2023;
originally announced July 2023.
-
In orbit performance of UVIT over the 5 years
Authors:
S. K. Ghosh,
P. Joseph,
A. Kumar,
J. Postma,
C. S. Stalin,
A. Subramaniam,
S. N. Tandon,
I. V. Barve,
A. Devaraj,
K. George,
V. Girish,
J. B. Hutchings,
P. U. Kamath,
S. Kathiravan,
J. P. Lancelot,
D. Leahy,
P. K. Mahesh,
R. Mohan,
S. Nagabhushana,
A. K. Pati,
N. Kameswara Rao,
K. Sankarasubramanian,
P. Sreekumar,
S. Sriram
Abstract:
Over the last 5 years, UVIT has completed observations of more than 500 proposals with ~ 800 unique pointings. In addition, regular planned monitoring observations have been made and from their analysis various key parameters related to in orbit performance of UVIT have been quantified. The sensitivities of the UV channels have remained steady indicating no effect of potential molecular contaminat…
▽ More
Over the last 5 years, UVIT has completed observations of more than 500 proposals with ~ 800 unique pointings. In addition, regular planned monitoring observations have been made and from their analysis various key parameters related to in orbit performance of UVIT have been quantified. The sensitivities of the UV channels have remained steady indicating no effect of potential molecular contamination confirming the adequacy of all the protocols implemented for avoiding contamination. The quality of the PSF through the years confirms adequacy of thermal control measures. The early calibrations obtained during the Performance Verification (PV) phase have been further revised for more subtle effects. These include flat fields and detector distortions with greater precision. The operations of UVIT have also evolved through in orbit experience, e.g. tweaking of operational sequencing, protocol for recovery from bright object detection (BOD) shutdowns, parameters for BOD thresholds, etc. Finally, some effects of charged particle hits on electronics led to opimised strategy for regular resetting. The Near-UV channel was lost in one of such operations. All the above in-orbit experiences are presented here.
△ Less
Submitted 25 December, 2020;
originally announced December 2020.
-
Additional Calibration of the Ultra-Violet Imaging Telescope on board AstroSat
Authors:
S. N. Tandon,
J. Postma,
P. Joseph,
A. Devaraj,
A Subramaniam,
I. V. Barve,
K. George,
S. K. Ghosh,
V. Girish,
J. B. Hutchings,
P. U. Kamath,
S. Kathiravan,
A. Kumar,
J. P. Lancelot,
D. Leahy,
P. K. Mahesh,
R. Mohan,
S. Nagabhushana,
A. K. Pati,
N. Kameswara Rao,
K. Sankarasubramanian,
S. Sriram,
C. S. Stalin
Abstract:
Results of the initial calibration of the Ultra-Violet Imaging Telescope (UVIT) were reported earlier by Tandon et al. (2017). The results reported earlier were based on the ground calibration as well as the first observations in orbit. Some additional data from the ground calibration and data from more in-orbit observations have been used to improve the results. In particular, extensive new data…
▽ More
Results of the initial calibration of the Ultra-Violet Imaging Telescope (UVIT) were reported earlier by Tandon et al. (2017). The results reported earlier were based on the ground calibration as well as the first observations in orbit. Some additional data from the ground calibration and data from more in-orbit observations have been used to improve the results. In particular, extensive new data from in-orbit observations have been used to obtain (a) new photometric calibration which includes (i) zero-points (ii) flat fields (iii) saturation, (b) sensitivity variations (c) spectral calibration for the near Ultra Violet (NUV; 2000 - 3000 Angstroms) and far Ultra-Violet (FUV; 1300 - 1800 Angstroms) gratings, (d) point spread function and (e) astrometric calibration which included distortion. Data acquired over the last three years show continued good performance of UVIT with no reduction in sensitivity in both the UV channels.
△ Less
Submitted 4 February, 2020;
originally announced February 2020.
-
Development of image motion compensation system for 1.3 m telescope at Vainu Bappu Observatory
Authors:
Sreekanth Reddy V,
Ravinder Kumar Banyal,
Sridharan R,
P U Kamath,
Aishwarya Selvaraj
Abstract:
We developed a tip-tilt system to compensate the turbulence induced image motion for 1.3 m telescope at Vainu Bappu Observatory, Kavalur. The instrument is designed to operate at visible wavelength band (480-700 nm) with a field of view $1^{\prime}\times1^{\prime}$. The tilt corrected images have shown up to $\approx$ 57% improvement in image resolution and a corresponding peak intensity increase…
▽ More
We developed a tip-tilt system to compensate the turbulence induced image motion for 1.3 m telescope at Vainu Bappu Observatory, Kavalur. The instrument is designed to operate at visible wavelength band (480-700 nm) with a field of view $1^{\prime}\times1^{\prime}$. The tilt corrected images have shown up to $\approx$ 57% improvement in image resolution and a corresponding peak intensity increase by a factor of $\approx$ 2.8. A closed-loop correction bandwidth of $\approx$ 26 Hz has been achieved with on-sky tests and the root mean square motion of the star image has been reduced by a factor of $\sim$ 14. These results are consistent with theoretical and numerical predictions of wave-front aberrations caused by atmospheric turbulence and image quality improvement expected from a real-time control system. In this paper, we present the details of the instrument design, laboratory calibration studies and quantify its performance on the telescope.
△ Less
Submitted 28 August, 2019;
originally announced August 2019.
-
Prospect for UV observations from the Moon. III. Assembly and ground calibration of Lunar Ultraviolet Cosmic Imager (LUCI)
Authors:
Joice Mathew,
B. G. Nair,
Margarita Safonova,
S. Sriram,
Ajin Prakash,
Mayuresh Sarpotdar,
S. Ambily,
Nirmal K.,
A. G. Sreejith,
Jayant Murthy,
P. U. Kamath,
S. Kathiravan,
B. R. Prasad,
Noah Brosch,
Norbert Kappelmann,
Nirmal Suraj Gadde,
Rahul Narayan
Abstract:
The Lunar Ultraviolet Cosmic Imager (LUCI) is a near-ultraviolet (NUV) telescope with all-spherical mirrors, designed and built to fly as a scientific payload on a lunar mission with Team Indus - the original Indian entry to the Google Lunar X-Prize. Observations from the Moon provide a unique opportunity of a stable platform with an unobstructed view of the space at all wavelengths due to the abs…
▽ More
The Lunar Ultraviolet Cosmic Imager (LUCI) is a near-ultraviolet (NUV) telescope with all-spherical mirrors, designed and built to fly as a scientific payload on a lunar mission with Team Indus - the original Indian entry to the Google Lunar X-Prize. Observations from the Moon provide a unique opportunity of a stable platform with an unobstructed view of the space at all wavelengths due to the absence of atmosphere and ionosphere. LUCI is an 80 mm aperture telescope, with a field of view of 27.6'x 20.4' and a spatial resolution of 5'', will scan the sky in the NUV (200-320 nm) domain to look for transient sources. We describe here the assembly, alignment, and calibration of the complete instrument. LUCI is now in storage in a class 1000 clean room and will be delivered to our flight partner in readiness for flight.
△ Less
Submitted 1 April, 2019; v1 submitted 18 March, 2019;
originally announced March 2019.
-
In-orbit Calibrations of the Ultra-Violet Imaging Telescope
Authors:
S. N. Tandon,
Annapurni Subramaniam,
V. Girish,
J. Postma,
K. Sankarasubramanian,
S. Sriram,
C. S. Stalin,
C. Mondal,
S. Sahu P. Joseph,
J. Hutchings,
S. K. Ghosh,
I. V. Barve,
K. George,
P. U. Kamath,
S. Kathiravan,
A. Kumar,
J. P. Lancelot,
D. Leahy,
P. K. Mahesh,
R. Mohan,
S. Nagabhushana,
A. K. Pati,
N. Kameswara Rao,
Y. H. Sreedhar,
P. Sreekumar
Abstract:
The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT, the first Indian Space Observatory. The UVIT instrument has two 375mm telescopes: one for the far-ultraviolet (FUV) channel (1300--1800Å), and the other for the near-ultraviolet (NUV) channel (2000--3000Å) and the visible (VIS) channel (3200--5500Å). UVIT is primarily designed for simultaneous imaging in the two ultravio…
▽ More
The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT, the first Indian Space Observatory. The UVIT instrument has two 375mm telescopes: one for the far-ultraviolet (FUV) channel (1300--1800Å), and the other for the near-ultraviolet (NUV) channel (2000--3000Å) and the visible (VIS) channel (3200--5500Å). UVIT is primarily designed for simultaneous imaging in the two ultraviolet channels with spatial resolution better than 1.8 arcsec, along with provision for slit-less spectroscopy in the NUV and FUV channels.The results of in-orbit calibrations of UVIT are presented in this paper.
△ Less
Submitted 5 August, 2017; v1 submitted 10 May, 2017;
originally announced May 2017.
-
In-orbit Performance of UVIT and First Results
Authors:
S. N. Tandon,
J. B. Hutchings,
S. K. Ghosh,
A. Subramaniam,
G. Koshy,
V. Girish V,
P. U. Kamath,
s. Kathiravan,
A. Kumar,
J. P. Lancelot,
P. K. Mahesh,
R. Mohan,
J. Murthy,
S. Nagabhushana,
A. K. Pati A,
J. Postma,
N. Kameswara Rao,
K. Sankarasubramanian,
P. Sreekumar,
S. Sriram,
C. S. Stalin,
F. Sutaria,
Y. H. Sreedhar,
I. V. Barve,
C. Mondal
, et al. (1 additional authors not shown)
Abstract:
The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is reported. The performance in orbit is also compared with estimates made from the calibrations done on the ground. The sensitivity is found to be within ~15% of the estimates, and the spatial resolution in the NUV is found to exceed significantly the design value of 1.8 arcsec and it is marginally better in the FUV. Images obt…
▽ More
The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is reported. The performance in orbit is also compared with estimates made from the calibrations done on the ground. The sensitivity is found to be within ~15% of the estimates, and the spatial resolution in the NUV is found to exceed significantly the design value of 1.8 arcsec and it is marginally better in the FUV. Images obtained from UVIT are presented to illustrate the details revealed by the high spatial resolution. The potential of multi-band observations in the ultraviolet with high spatial resolution is illustrated by some results.
△ Less
Submitted 2 December, 2016;
originally announced December 2016.
-
In-orbit Performance of UVIT on ASTROSAT
Authors:
Annapurni Subramaniam,
Shyam N. Tandon,
John Hutchings,
Swarna K. Ghosh,
Koshy George,
V. Girish,
P. U. Kamath,
S. Kathiravan,
Amit Kumar,
J. Paul Lancelot,
P. K. Mahesh,
Rekhesh Mohan,
Jayant Murthy,
S. Nagabhushana,
Ashok K. Pati,
Joe Postma,
N. Kameswara Rao,
Kasiviswanathan Sankarasubramanian,
P. Sreekumar,
S. Sriram,
Chelliah S. Stalin,
Firoza Sutaria,
Yuvraj Harsha Sreedhar,
Indrajit V. Barve,
Chayan Mondal
, et al. (1 additional authors not shown)
Abstract:
We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high gain photon counting mode wh…
▽ More
We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15\% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.
△ Less
Submitted 3 August, 2016;
originally announced August 2016.
-
Tests & Calibration on Ultra Violet Imaging Telescope (UVIT)
Authors:
Amit Kumar,
S. K. Ghosh,
P. U. Kamath,
Joe Postma,
S. Kathiravan,
P. K. Mahesh,
Nagbhushana. S,
K. H. Navalgund,
N Rajkumar,
M. N. Rao,
K. S. Sarma,
S. Sriram,
C. S. Stalin,
S. N. Tandon
Abstract:
Ultra Violet Imaging Telescope on ASTROSAT Satellite mission is a suite of Far Ultra Violet (FUV; 130 to 180 nm), Near Ultra Violet (NUV; 200 to 300 nm) and Visible band (VIS; 320 to 550nm) imagers. ASTROSAT is a first multi wavelength mission of INDIA. UVIT will image the selected regions of the sky simultaneously in three channels & observe young stars, galaxies, bright UV Sources. FOV in each o…
▽ More
Ultra Violet Imaging Telescope on ASTROSAT Satellite mission is a suite of Far Ultra Violet (FUV; 130 to 180 nm), Near Ultra Violet (NUV; 200 to 300 nm) and Visible band (VIS; 320 to 550nm) imagers. ASTROSAT is a first multi wavelength mission of INDIA. UVIT will image the selected regions of the sky simultaneously in three channels & observe young stars, galaxies, bright UV Sources. FOV in each of the 3 channels is about 28 arc-minute. Targeted angular resolution in the resulting UV images is better than 1.8 arc-second (better than 2.0 arc-second for the visible channel). Two identical co-aligned telescopes (T1, T2) of Ritchey-Chretien configuration (Primary mirror of 375 mm diameter) collect the celestial radiation and feed to the detector system via a selectable filter on a filter wheel mechanism; gratings are available in the filter wheels of FUV and NUV channels for slit-less low resolution spectroscopy. The detector system for each of the 3 channels is generically identical. One telescope images in the FUV channel, and other images in NUV and VIS channels. One time open-able mechanical cover on each telescope also works as Sun-shield after deployment.We will present the optical tests and calibrations done on the two telescopes. Results on vibrations test and thermo-vacuum tests on the engineering model will also be presented.
△ Less
Submitted 23 August, 2012;
originally announced August 2012.
-
Ultra Violet Imaging Telescope (UVIT) on ASTROSAT
Authors:
Amit Kumar,
S. K. Ghosh,
J. Hutchings,
P. U. Kamath,
S. Kathiravan,
P. K. Mahesh,
J. Murthy,
Nagbhushana. S,
A. K. Pati,
M. N. Rao,
N. K. Rao,
S. Sriram,
S. N. Tandon
Abstract:
Ultra Violet Imaging Telescope on ASTROSAT Satellite mission is a suite of Far Ultra Violet (FUV 130 to 180 nm), Near Ultra Violet (NUV 200 to 300 nm) and Visible band (VIS 320 to 550nm) imagers. ASTROSAT is the first multi wavelength mission of INDIA. UVIT will image the selected regions of the sky simultaneously in three channels and observe young stars, galaxies, bright UV Sources. FOV in each…
▽ More
Ultra Violet Imaging Telescope on ASTROSAT Satellite mission is a suite of Far Ultra Violet (FUV 130 to 180 nm), Near Ultra Violet (NUV 200 to 300 nm) and Visible band (VIS 320 to 550nm) imagers. ASTROSAT is the first multi wavelength mission of INDIA. UVIT will image the selected regions of the sky simultaneously in three channels and observe young stars, galaxies, bright UV Sources. FOV in each of the 3 channels is about 28 arc-minute. Targeted angular resolution in the resulting UV images is better than 1.8 arc-second (better than 2.0 arc-second for the visible channel). Two identical co-aligned telescopes (T1, T2) of Ritchey-Chretien configuration (Primary mirror of 375 mm diameter) collect celestial radiation and feed to the detector system via a selectable filter on a filter wheel mechanism; gratings are available in filter wheels of FUV and NUV channels for slit-less low resolution spectroscopy. The detector system for each of the 3 channels is generically identical. One of the telescopes images in the FUV channel, while the other images in NUV and VIS channels. Images from VIS channel are also used for measuring drift for reconstruction of images on ground through shift and add algorithm, and to reconstruct absolute aspect of the images. Adequate baffling has been provided for reducing scattered background from the Sun, earth albedo and other bright objects. One time open-able mechanical cover on each telescope also works as a Sun-shield after deployment. We are presenting here the overall (mechanical, optical and electrical) design of the payload.
△ Less
Submitted 23 August, 2012;
originally announced August 2012.