-
Characterization of aerogel scattering filters for astronomical telescopes
Authors:
Alyssa Barlis,
Stefan Arseneau,
Charles L. Bennett,
Thomas Essinger-Hileman,
Haiquan Guo,
Kyle R. Helson,
Tobias Marriage,
Manuel A. Quijada,
Ariel E. Tokarz,
Stephanie L. Vivod,
Edward J. Wollack
Abstract:
We have developed a suite of novel infrared-blocking filters made by embedding scattering particles in a polymer aerogel substrate. Our developments allow us to tune the spectral performance of the filters based on both the composition of the base aerogel material and the properties of the scattering particles. Our filters are targeted for use in a variety of applications, from ground-based CMB ex…
▽ More
We have developed a suite of novel infrared-blocking filters made by embedding scattering particles in a polymer aerogel substrate. Our developments allow us to tune the spectral performance of the filters based on both the composition of the base aerogel material and the properties of the scattering particles. Our filters are targeted for use in a variety of applications, from ground-based CMB experiments to planetary science probes. We summarize the formulations we have fabricated and tested to date, including several polyimide base aerogel formulations incorporating a range of size distributions of diamond scattering particles. We also describe the spectral characterization techniques used to measure the filters' optical properties, including the development of a mm-wave Fourier transform spectrometer testbed.
△ Less
Submitted 8 August, 2022;
originally announced August 2022.
-
Novel infrared-blocking aerogel scattering filters and their applications in astrophysical and planetary science
Authors:
Kyle R. Helson,
Stefan Arseneau,
Alyssa Barlis,
Charles L. Bennett,
Thomas M. Essinger-Hileman,
Haiquan Guo,
Tobias Marriage,
Manuel A. Quijada,
Ariel E. Tokarz,
Stephanie L. Vivod,
Edward J. Wollack
Abstract:
Infrared-blocking scattering aerogel filters have a broad range of potential applications in astrophysics and planetary science observations in the far-infrared, sub-millimeter, and microwave regimes. Successful dielectric modeling of aerogel filters allowed the fabrication of samples to meet the mechanical and science instrument requirements for several experiments, including the Sub-millimeter S…
▽ More
Infrared-blocking scattering aerogel filters have a broad range of potential applications in astrophysics and planetary science observations in the far-infrared, sub-millimeter, and microwave regimes. Successful dielectric modeling of aerogel filters allowed the fabrication of samples to meet the mechanical and science instrument requirements for several experiments, including the Sub-millimeter Solar Observation Lunar Volatiles Experiment (SSOLVE), the Cosmology Large Angular Scale Surveyor (CLASS), and the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). Thermal multi-physics simulations of the filters predict their performance when integrated into a cryogenic receiver. Prototype filters have survived cryogenic cycling to 4K with no degradation in mechanical properties.
△ Less
Submitted 17 August, 2022; v1 submitted 7 August, 2022;
originally announced August 2022.
-
Dielectric Properties of Conductively Loaded Polyimides in the Far Infrared
Authors:
Kyle R. Helson,
Kevin H. Miller Karwan Rostem,
Manuel Quijada,
Edward J. Wollack
Abstract:
The dielectric properties of selected conductively-loaded polyimide samples are characterized in microwave through far infrared wavebands. These materials, belonging to the Vespel\textsuperscript{\textregistered} family, are more readily formed by direct machining than their ceramic loaded epoxy counterparts and present an interesting solution for realizing absorptive optical control structures. M…
▽ More
The dielectric properties of selected conductively-loaded polyimide samples are characterized in microwave through far infrared wavebands. These materials, belonging to the Vespel\textsuperscript{\textregistered} family, are more readily formed by direct machining than their ceramic loaded epoxy counterparts and present an interesting solution for realizing absorptive optical control structures. Measurements spanning a spectral range from 1 to 600\,${\rm cm^{-1}}$ (0.03 to 18\,THz) were preformed and used in parametrization of the media's dielectric function at frequencies below $\approx3\,$THz.
△ Less
Submitted 11 October, 2018; v1 submitted 30 August, 2018;
originally announced October 2018.
-
Thermal architecture for the SPIDER flight cryostat
Authors:
J. E. Gudmundsson,
P. A. R. Ade,
M. Amiri,
S. J. Benton,
R. Bihary,
J. J. Bock,
J. R. Bond,
J. A. Bonetti,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
B. P. Crill,
D. O'Dea,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
N. N. Gandilo,
S. R. Golwala,
M. Halpern,
M. Hasselfield,
K. R. Helson,
G. Hilton,
W. Holmes,
V. V. Hristov,
K. D. Irwin
, et al. (18 additional authors not shown)
Abstract:
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooli…
▽ More
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled superfluid helium tank, which provide base operating temperatures of 4 K and 1.5 K, respectively. Closed-cycle helium-3 adsorption refrigerators supply sub-Kelvin cooling power to multiple focal planes, which are housed in monochromatic telescope inserts. The main helium tank is suspended inside the vacuum vessel with thermally insulating fiberglass flexures, and shielded from thermal radiation by a combination of two vapor cooled shields and multi-layer insulation. This system allows for an extremely low instrumental background and a hold time in excess of 25 days. The total mass of the cryogenic system, including cryogens, is approximately 1000 kg. This enables conventional long duration balloon flights. We will discuss the design, thermal analysis, and qualification of the cryogenic system.
△ Less
Submitted 13 June, 2011;
originally announced June 2011.
-
Modeling and characterization of the SPIDER half-wave plate
Authors:
Sean A. Bryan,
Peter A. R. Ade,
Mandana Amiri,
Steve Benton,
Richard Bihary,
James J. Bock,
J. Richard Bond,
Joseph A. Bonetti,
H. Cynthia Chiang,
Carlo R. Contaldi,
Brendan P. Crill,
Daniel O'Dea,
Olivier Dore,
Marzieh Farhang,
Jeffrey P. Filippini,
Laura Fissel,
Natalie Gandilo,
Sunil Golwala,
Jon E. Gudmundsson,
Matthew Hasselfield,
Mark Halpern,
Kyle R. Helson,
Gene Hilton,
Warren Holmes,
Viktor V. Hristov
, et al. (20 additional authors not shown)
Abstract:
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave t…
▽ More
Spider is a balloon-borne array of six telescopes that will observe the Cosmic Microwave Background. The 2624 antenna-coupled bolometers in the instrument will make a polarization map of the CMB with approximately one-half degree resolution at 145 GHz. Polarization modulation is achieved via a cryogenic sapphire half-wave plate (HWP) skyward of the primary optic. We have measured millimeter-wave transmission spectra of the sapphire at room and cryogenic temperatures. The spectra are consistent with our physical optics model, and the data gives excellent measurements of the indices of A-cut sapphire. We have also taken preliminary spectra of the integrated HWP, optical system, and detectors in the prototype Spider receiver. We calculate the variation in response of the HWP between observing the CMB and foreground spectra, and estimate that it should not limit the Spider constraints on inflation.
△ Less
Submitted 19 June, 2010;
originally announced June 2010.