-
The solar gravitational redshift from HARPS-LFC Moon spectra. A test of the General Theory of Relativity
Authors:
J. I. González Hernández,
R. Rebolo,
L. Pasquini,
G. Lo Curto,
P. Molaro,
E. Caffau,
H. -G. Ludwig,
M. Steffen,
M. Esposito,
A. Suárez Mascareño,
B. Toledo-Padrón,
R. A. Probst,
T. W. Hänsch,
R. Holzwarth,
A. Manescau,
T. Steinmetz,
Th. Udem,
T. Wilken
Abstract:
The General Theory of Relativity predicts the redshift of spectral lines in the solar photosphere, as a consequence of the gravitational potential of the Sun. This effect can be measured from a solar disk-integrated flux spectrum of the Sun's reflected light on solar system bodies. The laser frequency comb (LFC) calibration system attached to the HARPS spectrograph offers the possibility to perfor…
▽ More
The General Theory of Relativity predicts the redshift of spectral lines in the solar photosphere, as a consequence of the gravitational potential of the Sun. This effect can be measured from a solar disk-integrated flux spectrum of the Sun's reflected light on solar system bodies. The laser frequency comb (LFC) calibration system attached to the HARPS spectrograph offers the possibility to perform an accurate measurement of the solar gravitational redshift (GRS) by observing the Moon or other solar system bodies. We have analysed the line shift observed in Fe absorption lines from five high-quality HARPS-LFC spectra of the Moon. We select an initial sample of 326 photospheric Fe lines in the spectral range 476-585 nm and measure their line positions and equivalent widths (EWs). Accurate line shifts are derived from the wavelength position of the core of the lines compared with the laboratory wavelengths. We fit the observed spectral Fe lines using CO$^5$BOLD 3D synthetic profiles. Convective motions in the solar photosphere do not affect the line cores of Fe lines stronger than about $\sim 150$ mA. In our sample, only 15 FeI lines have EWs in the range $150 <$ EW(mA) $< 550$, providing a measurement of the solar GRS at $639\pm14$ ${\rm m\;s^{-1}}$, consistent with the expected theoretical value on Earth of $\sim 633.1$ ${\rm m\;s^{-1}}$. A final sample of about 97 weak Fe lines with EW $<180$ mA allows us to derive a mean global line shift of $638\pm6$ ${\rm m\;s^{-1}}$ in agreement with the theoretical solar GRS. These are the most accurate measurements of the solar GRS so far. Ultrastable spectrographs calibrated with the LFC over a larger spectral range, such as HARPS or ESPRESSO, together with a further improvement on the laboratory wavelengths, could provide a more robust measurement of the solar GRS and further tests for the 3D hydrodynamical models.
△ Less
Submitted 2 October, 2020; v1 submitted 22 September, 2020;
originally announced September 2020.
-
A crucial test for astronomical spectrograph calibration with frequency combs
Authors:
Rafael A. Probst,
Dinko Milaković,
Borja Toledo-Padrón,
Gaspare Lo Curto,
Gerardo Avila,
Anna Brucalassi,
Bruno L. Canto Martins,
Izan de Castro Leão,
Massimiliano Esposito,
Jonay I. González Hernández,
Frank Grupp,
Theodor W. Hänsch,
Hanna Kellermann,
Florian Kerber,
Olaf Mandel,
Antonio Manescau,
Eszter Pozna,
Rafael Rebolo,
José Renan de Medeiros,
Tilo Steinmetz,
Alejandro Suárez Mascareño,
Thomas Udem,
Josefina Urrutia,
Yuanjie Wu,
Luca Pasquini
, et al. (1 additional authors not shown)
Abstract:
Laser frequency combs (LFCs) are well on their way to becoming the next-generation calibration sources for precision astronomical spectroscopy. This development is considered key in the hunt for low-mass rocky exoplanets around solar-type stars whose discovery with the radial-velocity method requires cm/s Doppler precision. In order to prove such precise calibration with an LFC, it must be compare…
▽ More
Laser frequency combs (LFCs) are well on their way to becoming the next-generation calibration sources for precision astronomical spectroscopy. This development is considered key in the hunt for low-mass rocky exoplanets around solar-type stars whose discovery with the radial-velocity method requires cm/s Doppler precision. In order to prove such precise calibration with an LFC, it must be compared to another calibrator of at least the same precision. Being the best available spectrograph calibrator, this means comparing it to a second - fully independent - LFC. This test had long been pending, but our installation of two LFCs at the ultra-stable spectrograph HARPS presented the so far unique opportunity for simultaneous calibrations with two separate LFCs. Although limited in time, the test results confirm the 1 cm/s stability that has long been anticipated by the astronomical community.
△ Less
Submitted 20 February, 2020;
originally announced February 2020.
-
Characterization of a 450-km Baseline GPS Carrier-Phase Link using an Optical Fiber Link
Authors:
Stefan Droste,
Christian Grebing,
Julia Leute,
Sebastian M. F. Raupach,
Arthur Matveev,
Theodor W. Hänsch,
Andreas Bauch,
Ronald Holzwarth,
Gesine Grosche
Abstract:
A GPS carrier-phase frequency transfer link along a baseline of 450 km has been established and is characterized by comparing it to a phase-stabilized optical fiber link of 920 km length, established between the two endpoints, the Max-Planck-Institut für Quantenoptik in Garching and the Physikalisch-Technische Bundesanstalt in Braunschweig. The characterization is accomplished by comparing two act…
▽ More
A GPS carrier-phase frequency transfer link along a baseline of 450 km has been established and is characterized by comparing it to a phase-stabilized optical fiber link of 920 km length, established between the two endpoints, the Max-Planck-Institut für Quantenoptik in Garching and the Physikalisch-Technische Bundesanstalt in Braunschweig. The characterization is accomplished by comparing two active hydrogen masers operated at both institutes. The masers serve as local oscillators and cancel out when the double differences are calculated, such that they do not constitute a limitation for the GPS link characterization. We achieve a frequency instability of 3 x 10^(-13) in 30 s and 5 x 10^(-16) for long averaging times. Frequency comparison results obtained via both links show no deviation larger than the statistical uncertainty of 6 x 10^(-16). These results can be interpreted as a successful cross-check of the measurement uncertainty of a truly remote end fiber link.
△ Less
Submitted 5 May, 2015;
originally announced May 2015.
-
Comb-calibrated solar spectroscopy through a multiplexed single-mode fiber channel
Authors:
R A Probst,
L Wang,
H-P Doerr,
T Steinmetz,
T J Kentischer,
G Zhao,
T W Hänsch,
Th Udem,
R Holzwarth,
W Schmidt
Abstract:
We investigate a new scheme for astronomical spectrograph calibration using the laser frequency comb at the Solar Vacuum Tower Telescope on Tenerife. Our concept is based upon a single-mode fiber channel, that simultaneously feeds the spectrograph with comb light and sunlight. This yields nearly perfect spatial mode matching between the two sources. In combination with the absolute calibration pro…
▽ More
We investigate a new scheme for astronomical spectrograph calibration using the laser frequency comb at the Solar Vacuum Tower Telescope on Tenerife. Our concept is based upon a single-mode fiber channel, that simultaneously feeds the spectrograph with comb light and sunlight. This yields nearly perfect spatial mode matching between the two sources. In combination with the absolute calibration provided by the frequency comb, this method enables extremely robust and accurate spectroscopic measurements. The performance of this scheme is compared to a sequence of alternating comb and sunlight, and to absorption lines from Earth's atmosphere. We also show how the method can be used for radial-velocity detection by measuring the well-explored 5-minute oscillations averaged over the full solar disk. Our method is currently restricted to solar spectroscopy, but with further evolving fiber-injection techniques it could become an option even for faint astronomical targets.
△ Less
Submitted 17 February, 2015;
originally announced February 2015.
-
A Frequency Comb calibrated Solar Atlas
Authors:
P. Molaro,
M. Esposito,
S. Monai,
J. I. Gonzalez Hernandez,
T. W. Hansch,
R. Holzwarth,
A. Manescau,
L. Pasquini,
R. A. Probst,
R. Rebolo,
T. Steinmetz,
Th. Udem,
T. Wilken
Abstract:
The solar spectrum is a primary reference for the study of physical processes in stars and their variation during activity cycles. In Nov 2010 an experiment with a prototype of a Laser Frequency Comb (LFC) calibration system was performed with the HARPS spectrograph of the 3.6m ESO telescope at La Silla during which high signal-to-noise spectra of the Moon were obtained. We exploit those Echelle s…
▽ More
The solar spectrum is a primary reference for the study of physical processes in stars and their variation during activity cycles. In Nov 2010 an experiment with a prototype of a Laser Frequency Comb (LFC) calibration system was performed with the HARPS spectrograph of the 3.6m ESO telescope at La Silla during which high signal-to-noise spectra of the Moon were obtained. We exploit those Echelle spectra to study the optical integrated solar spectrum . The DAOSPEC program is used to measure solar line positions through gaussian fitting in an automatic way. We first apply the LFC solar spectrum to characterize the CCDs of the HARPS spectrograph. The comparison of the LFC and Th-Ar calibrated spectra reveals S-type distortions on each order along the whole spectral range with an amplitude of +/-40 m/s. This confirms the pattern found by Wilken et al. (2010) on a single order and extends the detection of the distortions to the whole analyzed region revealing that the precise shape varies with wavelength. A new data reduction is implemented to deal with CCD pixel inequalities to obtain a wavelength corrected solar spectrum. By using this spectrum we provide a new LFC calibrated solar atlas with 400 line positions in the range of 476-530, and 175 lines in the 534-585 nm range. The new LFC atlas improves the accuracy of individual lines by a significant factor reaching a mean value of about 10 m/s. The LFC--based solar line wavelengths are essentially free of major instrumental effects and provide a reference for absolute solar line positions. We suggest that future LFC observations could be used to trace small radial velocity changes of the whole solar photospheric spectrum in connection with the solar cycle and for direct comparison with the predicted line positions of 3D radiative hydrodynamical models of the solar photosphere.
△ Less
Submitted 18 October, 2013;
originally announced October 2013.
-
Laser frequency combs for astronomical observations
Authors:
Tilo Steinmetz,
Tobias Wilken,
Constanza Araujo-Hauck,
Ronald Holzwarth,
Theodor W. Hänsch,
Luca Pasquini,
Antonio Manescau,
Sandro D'Odorico,
Michael T. Murphy,
Thomas Kentischer,
Wolfgang Schmidt,
Thomas Udem
Abstract:
A direct measurement of the universe's expansion history could be made by observing in real time the evolution of the cosmological redshift of distant objects. However, this would require measurements of Doppler velocity drifts of about 1 centimeter per second per year, and astronomical spectrographs have not yet been calibrated to this tolerance. We demonstrate the first use of a laser frequenc…
▽ More
A direct measurement of the universe's expansion history could be made by observing in real time the evolution of the cosmological redshift of distant objects. However, this would require measurements of Doppler velocity drifts of about 1 centimeter per second per year, and astronomical spectrographs have not yet been calibrated to this tolerance. We demonstrate the first use of a laser frequency comb for wavelength calibration of an astronomical telescope. Even with a simple analysis, absolute calibration is achieved with an equivalent Doppler precision of approximately 9 meters per second at about 1.5 micrometers - beyond state-of-the-art accuracy. We show that tracking complex, time-varying systematic effects in the spectrograph and detector system is a particular advantage of laser frequency comb calibration. This technique promises an effective means for modeling and removal of such systematic effects to the accuracy required by future experiments to see direct evidence of the universe's putative acceleration.
△ Less
Submitted 9 September, 2008;
originally announced September 2008.
-
High-precision wavelength calibration of astronomical spectrographs with laser frequency combs
Authors:
M. T. Murphy,
Th. Udem,
R. Holzwarth,
A. Sizmann,
L. Pasquini,
C. Araujo-Hauck,
H. Dekker,
S. D'Odorico,
M. Fischer,
T. W. Hänsch,
A. Manescau
Abstract:
We describe a possible new technique for precise wavelength calibration of high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked lasers controlled by stable oscillators such as atomic clocks. Such `frequency combs' provide a series of narrow modes which are uniformly spaced according to the laser's pulse repetition rate and whose absolute frequencies are known a priori…
▽ More
We describe a possible new technique for precise wavelength calibration of high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked lasers controlled by stable oscillators such as atomic clocks. Such `frequency combs' provide a series of narrow modes which are uniformly spaced according to the laser's pulse repetition rate and whose absolute frequencies are known a priori with relative precision better than 10^{-12}. Simulations of frequency comb spectra show that the photon-limited wavelength calibration precision achievable with existing echelle spectrographs should be ~1 cm/s when integrated over a 4000A range. Moreover, comb spectra may be used to accurately characterise distortions of the wavelength scale introduced by the spectrograph and detector system. The simulations show that frequency combs with pulse repetition rates of 5-30GHz are required, given the typical resolving power of existing and possible future echelle spectrographs. Achieving such high repetition rates, together with the desire to produce all comb modes with uniform intensity over the entire optical range, represent the only significant challenges in the design of a practical system. Frequency comb systems may remove wavelength calibration uncertainties from all practical spectroscopic experiments, even those combining data from different telescopes over many decades.
△ Less
Submitted 28 June, 2007; v1 submitted 23 March, 2007;
originally announced March 2007.