-
Improved Dark Matter Search Sensitivity Resulting from LUX Low-Energy Nuclear Recoil Calibration
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (72 additional authors not shown)
Abstract:
Dual-phase xenon time projection chamber (TPC) detectors have demonstrated superior search sensitivities to dark matter over a wide range of particle masses. To extend their sensitivity to include low-mass dark matter interactions, it is critical to characterize both the light and charge responses of liquid xenon to sub-keV nuclear recoils. In this work, we report a new nuclear recoil calibration…
▽ More
Dual-phase xenon time projection chamber (TPC) detectors have demonstrated superior search sensitivities to dark matter over a wide range of particle masses. To extend their sensitivity to include low-mass dark matter interactions, it is critical to characterize both the light and charge responses of liquid xenon to sub-keV nuclear recoils. In this work, we report a new nuclear recoil calibration in the LUX detector $\textit{in situ}$ using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator. We demonstrate direct measurements of light and charge yields down to 0.45 keV (1.4 scintillation photons) and 0.27 keV (1.3 ionization electrons), respectively, approaching the physical limit of liquid xenon detectors. We discuss the implication of these new measurements on the physics reach of dual-phase xenon TPCs for nuclear-recoil-based low-mass dark matter detection.
△ Less
Submitted 14 October, 2022; v1 submitted 11 October, 2022;
originally announced October 2022.
-
First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment
Authors:
J. Aalbers,
D. S. Akerib,
C. W. Akerlof,
A. K. Al Musalhi,
F. Alder,
A. Alqahtani,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
S. Azadi,
A. J. Bailey,
A. Baker,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
M. J. Barry,
J. Barthel,
D. Bauer,
A. Baxter
, et al. (322 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis s…
▽ More
The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c$^2$. The most stringent limit is set for spin-independent scattering at 36 GeV/c$^2$, rejecting cross sections above 9.2$\times 10^{-48}$ cm$^2$ at the 90% confidence level.
△ Less
Submitted 2 August, 2023; v1 submitted 8 July, 2022;
originally announced July 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
N. Carrara,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
J. Ernst,
A. Fan,
S. Fiorucci
, et al. (75 additional authors not shown)
Abstract:
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations betwe…
▽ More
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. This technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.
△ Less
Submitted 17 October, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Cosmogenic production of $^{37}$Ar in the context of the LUX-ZEPLIN experiment
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
A. Baker,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
K. Beattie,
E. P. Bernard,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski
, et al. (183 additional authors not shown)
Abstract:
We estimate the amount of $^{37}$Ar produced in natural xenon via cosmic ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth's surface. We then calculate the resulting $^{37}$Ar concentration in a 10-tonne payload~(similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage and delivery to the…
▽ More
We estimate the amount of $^{37}$Ar produced in natural xenon via cosmic ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth's surface. We then calculate the resulting $^{37}$Ar concentration in a 10-tonne payload~(similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea level production rate of $^{37}$Ar in natural xenon is estimated to be 0.024~atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1~tonne/month, the average $^{37}$Ar activity after 10~tonnes are purified and transported underground is 0.058--0.090~$μ$Bq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic $^{37}$Ar will appear as a noticeable background in the early science data, while decaying with a 35~day half-life. This newly-noticed production mechanism of $^{37}$Ar should be considered when planning for future liquid xenon-based experiments.
△ Less
Submitted 22 March, 2022; v1 submitted 8 January, 2022;
originally announced January 2022.
-
Projected sensitivities of the LUX-ZEPLIN (LZ) experiment to new physics via low-energy electron recoils
Authors:
The LZ Collaboration,
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch
, et al. (172 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a dark matter detector expected to obtain world-leading sensitivity to weakly interacting massive particles (WIMPs) interacting via nuclear recoils with a ~7-tonne xenon target mass. This manuscript presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment and 2) an effective neutrino…
▽ More
LUX-ZEPLIN (LZ) is a dark matter detector expected to obtain world-leading sensitivity to weakly interacting massive particles (WIMPs) interacting via nuclear recoils with a ~7-tonne xenon target mass. This manuscript presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment and 2) an effective neutrino millicharge, both for pp-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axion-like particles forming the galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6t 1000d exposure and low expected rate of electron recoil backgrounds in the $<$100keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.
△ Less
Submitted 18 May, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (72 additional authors not shown)
Abstract:
We report here the results of an Effective Field Theory (EFT) WIMP search analysis using LUX data. We build upon previous LUX analyses by extending the search window to include nuclear recoil energies up to $\sim$180 keV$_{nr}$, requiring a reassessment of data quality cuts and background models. In order to use a binned Profile Likelihood statistical framework, the development of new analysis tec…
▽ More
We report here the results of an Effective Field Theory (EFT) WIMP search analysis using LUX data. We build upon previous LUX analyses by extending the search window to include nuclear recoil energies up to $\sim$180 keV$_{nr}$, requiring a reassessment of data quality cuts and background models. In order to use a binned Profile Likelihood statistical framework, the development of new analysis techniques to account for higher-energy backgrounds was required. With a 3.14$\times10^4$ kg$\cdot$day exposure using data collected between 2014 and 2016, we set 90\% C.L. exclusion limits on non-relativistic EFT WIMP couplings to neutrons and protons, providing the most stringent constraints on a significant fraction of the possible EFT WIMP interactions. Additionally, we report world-leading exclusion limits on inelastic EFT WIMP-nucleon recoils.
△ Less
Submitted 15 September, 2021; v1 submitted 13 February, 2021;
originally announced February 2021.
-
Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals
Authors:
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger
, et al. (162 additional authors not shown)
Abstract:
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matt…
▽ More
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In…
▽ More
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In this regime, extra precaution is required to reject a complex set of low-energy electron backgrounds that have long been observed in this class of detector. Noticing backgrounds from the wire grid electrodes near the top and bottom of the active target are particularly pernicious, we develop a machine learning technique based on ionization pulse shape to identify and reject these events. We demonstrate the technique can improve Poisson limits on low-mass DM interactions by a factor of $2$-$7$ with improvement depending heavily on the size of ionization signals. We use the technique on events in an effective $5$ tonne$\cdot$day exposure from LUX's 2013 science operation to place strong limits on low-mass DM particles with masses in the range $m_χ\in0.15$-$10$ GeV. This machine learning technique is expected to be useful for near-future experiments, such as LZ and XENONnT, which hope to perform low-mass DM searches with the stringent background control necessary to make a discovery.
△ Less
Submitted 18 November, 2020;
originally announced November 2020.
-
An Effective Field Theory Analysis of the First LUX Dark Matter Search
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese,
C. Gwilliam
, et al. (72 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first sc…
▽ More
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.
△ Less
Submitted 24 March, 2020;
originally announced March 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Extending light WIMP searches to single scintillation photons in LUX
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
L. de Viveiros,
A. Dobi
, et al. (100 additional authors not shown)
Abstract:
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its…
▽ More
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
△ Less
Submitted 27 December, 2019; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi
, et al. (76 additional authors not shown)
Abstract:
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
△ Less
Submitted 7 June, 2019; v1 submitted 29 March, 2019;
originally announced March 2019.
-
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electr…
▽ More
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
△ Less
Submitted 16 October, 2019; v1 submitted 27 November, 2018;
originally announced November 2018.
-
Search for annual and diurnal rate modulations in the LUX experiment
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (71 additional authors not shown)
Abstract:
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calen…
▽ More
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$σ$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
△ Less
Submitted 27 September, 2018; v1 submitted 18 July, 2018;
originally announced July 2018.