-
International Astrophysical Consortium for High-energy Calibration: Summary of the 15th IACHEC Workshop
Authors:
K. K. Madsen,
V. Burwitz,
K. Forster,
C. E. Grant,
M. Guainazzi,
V. Kashyap,
H. L. Marshall,
E. D. Miller,
L. Natalucci,
P. P. Plucinsky,
Y. Terada
Abstract:
In this report, we summarize the activities of the International Astronomical Consortium for High Energy Calibration (IACHEC) from the 15th IACHEC Workshop in Pelham, Germany. Sixty scientists directly involved in the calibration of operational and future high-energy missions gathered for 3.5 days to discuss the status of the cross-calibration between the current international complement of X-ray…
▽ More
In this report, we summarize the activities of the International Astronomical Consortium for High Energy Calibration (IACHEC) from the 15th IACHEC Workshop in Pelham, Germany. Sixty scientists directly involved in the calibration of operational and future high-energy missions gathered for 3.5 days to discuss the status of the cross-calibration between the current international complement of X-ray observatories and the possibilities to improve it. This summary consists of reports from the Working Groups with topics ranging across the identification and characterization of standard calibration sources, multi-observatory cross-calibration campaigns, appropriate and new statistical techniques, calibration of instruments and characterization of background, preservation of knowledge, and results for the benefit of the astronomical community.
△ Less
Submitted 12 July, 2024;
originally announced July 2024.
-
Curved detectors for future X-ray astrophysics missions
Authors:
Eric D. Miller,
James A. Gregory,
Marshall W. Bautz,
Harry R. Clark,
Michael Cooper,
Kevan Donlon,
Richard F. Foster,
Catherine E. Grant,
Mallory Jensen,
Beverly LaMarr,
Renee Lambert,
Christopher Leitz,
Andrew Malonis,
Mo Neak,
Gregory Prigozhin,
Kevin Ryu,
Benjamin Schneider,
Keith Warner,
Douglas J. Young,
William W. Zhang
Abstract:
Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring a large area detector system that closely conforms to the curved focal surface. We have embarked on a project using a curved charge-coupled device (CCD) detect…
▽ More
Future X-ray astrophysics missions will survey large areas of the sky with unparalleled sensitivity, enabled by lightweight, high-resolution optics. These optics inherently produce curved focal surfaces with radii as small as 2 m, requiring a large area detector system that closely conforms to the curved focal surface. We have embarked on a project using a curved charge-coupled device (CCD) detector technology developed at MIT Lincoln Laboratory to provide large-format, curved detectors for such missions, improving performance and simplifying design. We present the current status of this work, which aims to curve back-illuminated, large-format (5 cm x 4 cm) CCDs to 2.5-m radius and confirm X-ray performance. We detail the design of fixtures and the curving process, and present intial results on curving bare silicon samples and monitor devices and characterizing the surface geometric accuracy. The tests meet our accuracy requirement of <5 $μ$m RMS surface non-conformance for samples of similar thickness to the functional detectors. We finally show X-ray performance measurements of planar CCDs that will serve as a baseline to evaluate the curved detectors. The detectors exhibit low noise, good charge-transfer efficiency, and excellent, uniform spectroscopic performance, including in the important soft X-ray band.
△ Less
Submitted 26 June, 2024;
originally announced June 2024.
-
The Advanced CCD Imaging Spectrometer on the Chandra X-ray Observatory: twenty-five years of on-orbit operation
Authors:
Catherine E. Grant,
Marshall W. Bautz,
Paul P. Plucinsky,
Peter G. Ford
Abstract:
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory completes a quarter century of on orbit operations, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination, changing particle environment, and aging of the spacecraft in general. We…
▽ More
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory completes a quarter century of on orbit operations, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination, changing particle environment, and aging of the spacecraft in general. We present highlights from the instrument team's monitoring program and our expectations for the future of ACIS. Performance changes on ACIS continue to be manageable, and do not indicate any limitations on ACIS lifetime. We examine aspects of the design and operation of ACIS that have impacted its long lifetime with lessons learned for future instruments.
△ Less
Submitted 26 June, 2024;
originally announced June 2024.
-
Advancing Precision Particle Background Estimation for Future X-ray Missions: Correlated Variability between AMS and Chandra/XMM-Newton
Authors:
Arnab Sarkar,
Catherine E. Grant,
Eric D. Miller,
Mark Bautz,
Benjamin Schneider,
Rick F. Foster,
Gerrit Schellenberger,
Steven Allen,
Ralph P. Kraft,
Dan Wilkins,
Abe Falcone,
Andrew Ptak
Abstract:
Galactic cosmic ray (GCR) particles have a significant impact on the particle-induced background of X-ray observatories, and their flux exhibits substantial temporal variability, potentially influencing background levels. In this study, we present one-day binned high-energy reject rates derived from the Chandra-ACIS and XMM-Newton EPIC-pn instruments, serving as proxies for GCR particle flux. We s…
▽ More
Galactic cosmic ray (GCR) particles have a significant impact on the particle-induced background of X-ray observatories, and their flux exhibits substantial temporal variability, potentially influencing background levels. In this study, we present one-day binned high-energy reject rates derived from the Chandra-ACIS and XMM-Newton EPIC-pn instruments, serving as proxies for GCR particle flux. We systematically analyze the ACIS and EPIC-pn reject rates and compare them with the AMS proton flux. Our analysis initially reveals robust correlations between the AMS proton flux and the ACIS/EPIC-pn reject rates when binned over 27-day intervals. However, a closer examination reveals substantial fluctuations within each 27-day bin, indicating shorter-term variability. Upon daily binning, we observe finer. temporal structures in the datasets, demonstrating the presence of recurrent variations with periods of $\sim$ 25 days and 23 days in ACIS and EPIC-pn reject rates, respectively, spanning the years 2014 to 2018. Notably, during the 2016--2017 period, we additionally detect periodicities of $\sim$13.5 days and 9 days in the ACIS and EPIC-pn reject rates, respectively. Intriguingly, we observe a time lag of $\sim$ 6 days between the AMS proton flux and the ACIS/EPIC-pn reject rates during the second half of 2016. This time lag is not visible before 2016 and aftern2017. The underlying physical mechanisms responsible for this time lag remain a subject of ongoing investigation.
△ Less
Submitted 10 May, 2024;
originally announced May 2024.
-
On the Particle Acceleration Mechanisms in a Double Radio Relic Galaxy Cluster, Abell 1240
Authors:
Arnab Sarkar,
Felipe Andrade-Santos,
Reinout J. van Weeren,
Ralph P. Kraft,
Duy N. Hoang,
Timothy W. Shimwell,
Paul Nulsen,
William Forman,
Scott Randall,
Yuanyuan Su,
Priyanka Chakraborty,
Christine Jones,
Eric Miller,
Mark Bautz,
Catherine E. Grant
Abstract:
We present a 368 ks deep Chandra observation of Abell~1240, a binary merging galaxy cluster at a redshift of 0.195 with two Brightest Cluster Galaxies (BCGs) may have passed each other 0.3 Gyr ago. Building upon previous investigations involving GMRT, VLA, and LOFAR data, our study focuses on two prominent extended radio relics at the north-west (NW) and south-east (SE) of the cluster core. By lev…
▽ More
We present a 368 ks deep Chandra observation of Abell~1240, a binary merging galaxy cluster at a redshift of 0.195 with two Brightest Cluster Galaxies (BCGs) may have passed each other 0.3 Gyr ago. Building upon previous investigations involving GMRT, VLA, and LOFAR data, our study focuses on two prominent extended radio relics at the north-west (NW) and south-east (SE) of the cluster core. By leveraging the high-resolution Chandra imaging, we have identified two distinct surface brightness edges at $\sim$ 1 Mpc and 1.2 Mpc NW and SE of the cluster center, respectively, coinciding with the outer edges of both relics. Our temperature measurements hint the edges to be shock front edges. The Mach numbers, derived from the gas density jumps, yield $\cal{M}_{\rm SE}$ = 1.49$^{+0.22}_{-0.24}$ for the South Eastern shock and $\cal{M}_{\rm NW}$ = 1.41$^{+0.17}_{-0.19}$ for the North Western shock. Our estimated Mach numbers are remarkably smaller compared to those derived from radio observations ($\cal{M}_{\rm SE}$ = 2.3 and $\cal{M}_{\rm NW}$ = 2.4), highlighting the prevalence of a re-acceleration scenario over direct acceleration of electrons from the thermal pool. Furthermore, we compare the observed temperature profiles across both shocks with that of predictions from collisional vs. collisionless models. Both shocks favor the Coulomb collisional model, but we could not rule out a purely collisionless model due to pre-shock temperature uncertainties.
△ Less
Submitted 12 January, 2024; v1 submitted 3 January, 2024;
originally announced January 2024.
-
Overview of the Advanced X-ray Imaging Satellite (AXIS)
Authors:
Christopher S. Reynolds,
Erin A. Kara,
Richard F. Mushotzky,
Andrew Ptak,
Michael J. Koss,
Brian J. Williams,
Steven W. Allen,
Franz E. Bauer,
Marshall Bautz,
Arash Bodaghee,
Kevin B. Burdge,
Nico Cappelluti,
Brad Cenko,
George Chartas,
Kai-Wing Chan,
Lía Corrales,
Tansu Daylan,
Abraham D. Falcone,
Adi Foord,
Catherine E. Grant,
Mélanie Habouzit,
Daryl Haggard,
Sven Herrmann,
Edmund Hodges-Kluck,
Oleg Kargaltsev
, et al. (18 additional authors not shown)
Abstract:
The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class concept that will build on the legacy of the Chandra X-ray Observatory by providing low-background, arcsecond-resolution imaging in the 0.3-10 keV band across a 450 arcminute$^2$ field of view, with an order of magnitude improvement in sensitivity. AXIS utilizes breakthroughs in the construction of lightweight segmented X-ray optics usin…
▽ More
The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class concept that will build on the legacy of the Chandra X-ray Observatory by providing low-background, arcsecond-resolution imaging in the 0.3-10 keV band across a 450 arcminute$^2$ field of view, with an order of magnitude improvement in sensitivity. AXIS utilizes breakthroughs in the construction of lightweight segmented X-ray optics using single-crystal silicon, and developments in the fabrication of large-format, small-pixel, high readout rate CCD detectors with good spectral resolution, allowing a robust and cost-effective design. Further, AXIS will be responsive to target-of-opportunity alerts and, with onboard transient detection, will be a powerful facility for studying the time-varying X-ray universe, following on from the legacy of the Neil Gehrels (Swift) X-ray observatory that revolutionized studies of the transient X-ray Universe. In this paper, we present an overview of AXIS, highlighting the prime science objectives driving the AXIS concept and how the observatory design will achieve these objectives.
△ Less
Submitted 1 November, 2023;
originally announced November 2023.
-
The high-speed X-ray camera on AXIS
Authors:
Eric D. Miller,
Marshall W. Bautz,
Catherine E. Grant,
Richard F. Foster,
Beverly LaMarr,
Andrew Malonis,
Gregory Prigozhin,
Benjamin Schneider,
Christopher Leitz,
Sven Herrmann,
Steven W. Allen,
Tanmoy Chattopadhyay,
Peter Orel,
R. Glenn Morris,
Haley Stueber,
Abraham D. Falcone,
Andrew Ptak,
Christopher Reynolds
Abstract:
AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying ab…
▽ More
AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying aboard missions such as Chandra and Suzaku, while retaining the low noise, excellent spectral performance, and low power requirements of those instruments. We present the design of the AXIS high-speed X-ray camera, which baselines large-format MIT Lincoln Laboratory CCDs employing low-noise pJFET output amplifiers and a single-layer polysilicon gate structure that allows fast, low-power clocking. These detectors are combined with an integrated high-speed, low-noise ASIC readout chip from Stanford University that provides better performance than conventional discrete solutions at a fraction of their power consumption and footprint. Our complementary front-end electronics concept employs state of the art digital video waveform capture and advanced signal processing to deliver low noise at high speed. We review the current performance of this technology, highlighting recent improvements on prototype devices that achieve excellent noise characteristics at the required readout rate. We present measurements of the CCD spectral response across the AXIS energy band, augmenting lab measurements with detector simulations that help us understand sources of charge loss and evaluate the quality of the CCD backside passivation technique. We show that our technology is on a path that will meet our requirements and enable AXIS to achieve world-class science.
△ Less
Submitted 1 September, 2023;
originally announced September 2023.
-
Reducing the background in X-ray imaging detectors via machine learning
Authors:
D. R. Wilkins,
S. W. Allen,
E. D. Miller,
M. Bautz,
T. Chattopadhyay,
R. Foster,
C. E. Grant,
S. Hermann,
R. Kraft,
R. G. Morris,
P. Nulsen,
G. Schellenberger
Abstract:
The sensitivity of astronomical X-ray detectors is limited by the instrumental background. The background is especially important when observing low surface brightness sources that are critical for many of the science cases targeted by future X-ray observatories, including Athena and future US-led flagship or probe-class X-ray missions. Above 2keV, the background is dominated by signals induced by…
▽ More
The sensitivity of astronomical X-ray detectors is limited by the instrumental background. The background is especially important when observing low surface brightness sources that are critical for many of the science cases targeted by future X-ray observatories, including Athena and future US-led flagship or probe-class X-ray missions. Above 2keV, the background is dominated by signals induced by cosmic rays interacting with the spacecraft and detector. We develop novel machine learning algorithms to identify events in next-generation X-ray imaging detectors and to predict the probability that an event is induced by a cosmic ray vs. an astrophysical X-ray photon, enabling enhanced filtering of the cosmic ray-induced background. We find that by learning the typical correlations between the secondary events that arise from a single primary, machine learning algorithms are able to successfully identify cosmic ray-induced background events that are missed by traditional filtering methods employed on current-generation X-ray missions, reducing the unrejected background by as much as 30 per cent.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Understanding the effects of charge diffusion in next-generation soft X-ray imagers
Authors:
Eric D. Miller,
Gregory Y. Prigozhin,
Beverly J. LaMarr,
Marshall W. Bautz,
Richard F. Foster,
Catherine E. Grant,
Craig S. Lage,
Christopher Leitz,
Andrew Malonis
Abstract:
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and i…
▽ More
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and is potentially lost below the imposed noise threshold. In an effort to understand these subtle but significant effects and inform the design and requirements of future detectors, we present simulations of charge diffusion using a variety of detector characteristics and operational settings, assessing spectral response at a range of X-ray energies. We validate the simulations by comparing the performance to that of real CCD detectors tested in the lab and deployed in space, spanning a range of thickness, pixel size, and other characteristics. The simulations show that while larger pixels, higher bias voltage, and optimal backside passivation improve performance, reducing the readout noise has a dominant effect in all cases. We finally show how high-pixel-aspect-ratio devices present challenges for measuring the backside passivation performance due to the magnitude of other processes that degrade spectral response, and present a method for utilizing the simulations to qualitatively assess this performance. Since compelling science requirements often compete technically with each other (high spatial resolution, soft X-ray response, hard X-ray response), these results can be used to find the proper balance for a future high-spatial-resolution X-ray instrument.
△ Less
Submitted 15 August, 2022;
originally announced August 2022.
-
Towards precision particle background estimation for future X-ray missions: correlated variability between Chandra ACIS and AMS
Authors:
Catherine E. Grant,
Eric D. Miller,
Marshall W. Bautz,
Richard Foster,
Ralph P. Kraft,
Steven Allen,
David N. Burrows
Abstract:
A science goal of many future X-ray observatories is mapping the cosmic web through deep exposures of faint diffuse sources. Such observations require low background and the best possible knowledge of the remaining unrejected background. The dominant contribution to the background above 1-2 keV is from Galactic Cosmic Ray protons. Their flux and spectrum are modulated by the solar cycle but also b…
▽ More
A science goal of many future X-ray observatories is mapping the cosmic web through deep exposures of faint diffuse sources. Such observations require low background and the best possible knowledge of the remaining unrejected background. The dominant contribution to the background above 1-2 keV is from Galactic Cosmic Ray protons. Their flux and spectrum are modulated by the solar cycle but also by solar activity on shorter timescales. Understanding this variability may prove crucial to reducing background uncertainty for ESA's Athena X-ray Observatory and other missions with large collecting area. We examine of the variability of the particle background as measured by ACIS on the Chandra X-ray Observatory and compare that variability to that measured by the Alpha Magnetic Spectrometer (AMS), a precision particle detector on the ISS. We show that cosmic ray proton variability measured by AMS is well matched to the ACIS background and can be used to estimate proton energies responsible for the background. We discuss how this can inform future missions.
△ Less
Submitted 1 August, 2022;
originally announced August 2022.
-
The origin of the unfocused XMM-Newton background, its variability and lessons learned for ATHENA
Authors:
Fabio Gastaldello,
Martino Marelli,
Silvano Molendi,
Iacopo Bartalucci,
Patrick Kühl,
Catherine E. Grant,
Simona Ghizzardi,
Mariachiara Rossetti,
Andrea De Luca,
Andrea Tiengo
Abstract:
We analyzed the unexposed to the sky outFOV region of the MOS2 detector on board XMM-Newton covering 15 years of data amounting to 255 Ms. We show convincing evidence that the origin of the unfocused background in XMM-Newton is due to energetic protons, electrons and hard X-ray photons. Galactic Cosmic Rays are the main contributors as shown by the tight correlation (2.6% of total scatter) with 1…
▽ More
We analyzed the unexposed to the sky outFOV region of the MOS2 detector on board XMM-Newton covering 15 years of data amounting to 255 Ms. We show convincing evidence that the origin of the unfocused background in XMM-Newton is due to energetic protons, electrons and hard X-ray photons. Galactic Cosmic Rays are the main contributors as shown by the tight correlation (2.6% of total scatter) with 1 GeV protons data of the SOHO EPHIN detector. Tight correlations are found with a proxy of the Chandra background rate, revealing the common source of background for detectors in similar orbits, and with the data of the EPIC Radiation Monitor (ERM), only when excluding Solar Energetic Particles events (SEPs). The entrance to the outer electron belts is associated to a sudden increase in the outFOV MOS2 rate and a spectral change. These facts support the fact that MeV electrons can generate an unfocused background signal. The correlation between MOS2 outFOV data and the SOHO EPHIN data reveals a term constant in time and isotropic similar to the one found in the study of the pn data. The most plausible origin of this component is hard unfocused X-ray photons of the Cosmic X-ray Background (CXB) Compton-scattering in the detector as supported by the strength of the signal in the two detectors with different thicknesses. Based on this physical understanding a particle radiation monitor on board ATHENA has been proposed and it is currently under study. It will be able to track different species with the necessary accuracy and precision to guarantee the challenging requirement of 2% reproducibility of the background.
△ Less
Submitted 10 February, 2022;
originally announced February 2022.
-
Mitigating the effects of particle background on the Athena Wide-Field Imager
Authors:
Eric D. Miller,
Catherine E. Grant,
Marshall W. Bautz,
Silvano Molendi,
Ralph Kraft,
Paul Nulsen,
Esra Bulbul,
Steven Allen,
David N. Burrows,
Tanja Eraerds,
Valentina Fioretti,
Fabio Gastaldello,
David Hall,
Michael W. J. Hubbard,
Jonathan Keelan,
Norbert Meidinger,
Emanuele Perinati,
Arne Rau,
Dan Wilkins
Abstract:
The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with…
▽ More
The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.
△ Less
Submitted 31 January, 2022;
originally announced February 2022.
-
Measurement and simulation of charge diffusion in a small-pixel charge-coupled device
Authors:
Beverly J. LaMarr,
Gregory Y. Prigozhin,
Eric D. Miller,
Carolyn Thayer,
Marshall W. Bautz,
Richard Foster,
Catherine E. Grant,
Andrew Malonis,
Barry E. Burke,
Michael Cooper,
Kevan Donlon,
Christopher Leitz
Abstract:
Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packe…
▽ More
Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packets. We investigate consequences for sensor performance, reporting charge diffusion measurements in a fully-depleted, 50um thick, back-illuminated CCD with 8um pixels. We are able to measure the size distributions of charge packets produced by 5.9 keV and 1.25 keV X-rays in this device. We find that individual charge packets exhibit a gaussian spatial distribution, and determine the frequency distribution of event widths for a range of internal electric field strength levels. We find a standard deviation for the largest charge packets, which occur near the entrance window, of 3.9um. We show that the shape of the event width distribution provides a clear indicator of full depletion and infer the relationship between event width and interaction depth. We compare measured width distributions to simulations. We compare traditional, 'sum-above-threshold' algorithms for event amplitude determination to 2D gaussian fitting of events and find better spectroscopic performance with the former for 5.9 keV events and comparable results at 1.25 keV. The reasons for this difference are discussed. We point out the importance of read noise driven detection thresholds in spectral resolution, and note that the derived read noise requirements for mission concepts such as AXIS and Lynx may be too lax to meet spectral resolution requirements. While we report measurements made with a CCD, we note that they have implications for the performance of high aspect-ratio silicon active pixel sensors as well.
△ Less
Submitted 19 January, 2022;
originally announced January 2022.
-
IACHEC 2020/2021 Pandemic Report
Authors:
K. K. Madsen,
V. Burwitz,
K. Forster,
C. E. Grant,
M. Guainazzi,
V. Kashyap,
H. L. Marshall,
E. D. Miller,
L. Natalucci,
P. P. Plucinsky,
Y. Terada
Abstract:
In this report we summarize the activities of the International Astronomical Consortium for High Energy Calibration (IACHEC) and the work done since the last in-person meeting in Japan (Shonan Village Center), May 2019, through two virtual meetings that were held in November 2020 and May 2021. The on-line only meetings divided the contents of the usual in-person workshop between mission updates an…
▽ More
In this report we summarize the activities of the International Astronomical Consortium for High Energy Calibration (IACHEC) and the work done since the last in-person meeting in Japan (Shonan Village Center), May 2019, through two virtual meetings that were held in November 2020 and May 2021. The on-line only meetings divided the contents of the usual in-person workshop between mission updates and working group updates. The November meeting was dedicated to mission calibration updates and the current status of the cross-calibration between NuSTAR, Swift, and NICER, which frequently join together in observations of bright transients, and a review of the XMM-Newton and Chandra cross-calibration. Results between \nustar\ and \swift\ overall show good agreement, but issues persist in the overlap region 3--5 keV for bright source with large dust scattering halos. The NICER cross-calibration is still progressing and evolving, while for the XMM-Newton and Chandra cross-calibration systematic differences both in the absolute flux and spectral shape determination still exists on different classes of sources. The meeting in May was focused on the Working Group progress and reports summarized here.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Identifying charged particle background events in X-ray imaging detectors with novel machine learning algorithms
Authors:
D. R. Wilkins,
S. W. Allen,
E. D. Miller,
M. Bautz,
T. Chattopadhyay,
S. Fort,
C. E. Grant,
S. Herrmann,
R. Kraft,
R. G. Morris,
P. Nulsen
Abstract:
Space-based X-ray detectors are subject to significant fluxes of charged particles in orbit, notably energetic cosmic ray protons, contributing a significant background. We develop novel machine learning algorithms to detect charged particle events in next-generation X-ray CCDs and DEPFET detectors, with initial studies focusing on the Athena Wide Field Imager (WFI) DEPFET detector. We train and t…
▽ More
Space-based X-ray detectors are subject to significant fluxes of charged particles in orbit, notably energetic cosmic ray protons, contributing a significant background. We develop novel machine learning algorithms to detect charged particle events in next-generation X-ray CCDs and DEPFET detectors, with initial studies focusing on the Athena Wide Field Imager (WFI) DEPFET detector. We train and test a prototype convolutional neural network algorithm and find that charged particle and X-ray events are identified with a high degree of accuracy, exploiting correlations between pixels to improve performance over existing event detection algorithms. 99 per cent of frames containing a cosmic ray are identified and the neural network is able to correctly identify up to 40 per cent of the cosmic rays that are missed by current event classification criteria, showing potential to significantly reduce the instrumental background, and unlock the full scientific potential of future X-ray missions such as Athena, Lynx and AXIS.
△ Less
Submitted 2 December, 2020;
originally announced December 2020.
-
Reducing the Athena WFI charged particle background: Results from Geant4 simulations
Authors:
Catherine E. Grant,
Eric D. Miller,
Marshall W. Bautz,
Tanja Eraerds,
Silvano Molendi,
Jonathan Keelan,
David Hall,
Andrew D. Holland,
Ralph P. Kraft,
Esra Bulbul,
Paul Nulsen,
Steven Allen
Abstract:
One of the science goals of the Wide Field Imager (WFI) on ESA's Athena X-ray observatory is to map hot gas structures in the universe, such as clusters and groups of galaxies and the intergalactic medium. These deep observations of faint diffuse sources require low background and the best possible knowledge of that background. The WFI Background Working Group is approaching this problem from a va…
▽ More
One of the science goals of the Wide Field Imager (WFI) on ESA's Athena X-ray observatory is to map hot gas structures in the universe, such as clusters and groups of galaxies and the intergalactic medium. These deep observations of faint diffuse sources require low background and the best possible knowledge of that background. The WFI Background Working Group is approaching this problem from a variety of directions. Here we present analysis of Geant4 simulations of cosmic ray particles interacting with the structures aboard Athena, producing signal in the WFI. We search for phenomenological correlations between these particle tracks and detected events that would otherwise be categorized as X-rays, and explore ways to exploit these correlations to flag or reject such events in ground processing. In addition to reducing the Athena WFI instrumental background, these results are applicable to understanding the particle component in any silicon-based X-ray detector in space.
△ Less
Submitted 2 December, 2020;
originally announced December 2020.
-
Summary of the 14th IACHEC Meeting
Authors:
K. K. Madsen,
Y. Terada,
V. Burwitz,
G. Belanger,
C. E. Grant,
M. Guainazzi,
V. Kashyap,
H. L. Marshall,
E. D. Miller,
L. Natalucci,
P. P. Plucinsky
Abstract:
We summarize the 14th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC) held at \textit{Shonan Village} (Kanagawa, Japan) in May 2019. Sixty scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the cross-calibration between the current international complement of X-ra…
▽ More
We summarize the 14th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC) held at \textit{Shonan Village} (Kanagawa, Japan) in May 2019. Sixty scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the cross-calibration between the current international complement of X-ray observatories, and the possibilities to improve it. This summary consists of reports from the various WGs with topics ranging from the identification and characterization of standard calibration sources, multi-observatory cross-calibration campaigns, appropriate and new statistical techniques, calibration of instruments and characterization of background, communication and preservation of knowledge, and results for the benefit of the astronomical community.
△ Less
Submitted 29 January, 2020;
originally announced January 2020.
-
The Advanced X-ray Imaging Satellite
Authors:
Richard F. Mushotzky,
James Aird,
Amy J. Barger,
Nico Cappelluti,
George Chartas,
Lia Corrales,
Rafael Eufrasio,
Andrew C. Fabian,
Abraham D. Falcone,
Elena Gallo,
Roberto Gilli,
Catherine E. Grant,
Martin Hardcastle,
Edmund Hodges-Kluck,
Erin Kara,
Michael Koss,
Hui Li,
Carey M. Lisse,
Michael Loewenstein,
Maxim Markevitch,
Eileen T. Meyer,
Eric D. Miller,
John Mulchaey,
Robert Petre,
Andrew J. Ptak
, et al. (19 additional authors not shown)
Abstract:
Much of the baryonic matter in the Universe, including the most active and luminous sources, are best studied in the X-ray band. Key advances in X-ray optics and detectors have paved the way for the Advanced X-ray Imaging Satellite (AXIS), a Probe-class mission that is a major improvement over Chandra, which has generated a steady stream of important discoveries for the past 2 decades. AXIS can be…
▽ More
Much of the baryonic matter in the Universe, including the most active and luminous sources, are best studied in the X-ray band. Key advances in X-ray optics and detectors have paved the way for the Advanced X-ray Imaging Satellite (AXIS), a Probe-class mission that is a major improvement over Chandra, which has generated a steady stream of important discoveries for the past 2 decades. AXIS can be launched in the late 2020s and will transform our understanding in several major areas of astrophysics, including the growth and fueling of supermassive black holes, galaxy formation and evolution, the microphysics of cosmic plasmas, the time-variable universe, and a wide variety of cutting-edge studies. Relative to Chandra, the AXIS PSF is nearly twice as sharp on-axis; its field of view for subarcsecond imaging 70 times larger by area; its effective area at 1 keV is 10 times larger. The low-Earth orbit ensures a low and stable detector background, resulting in 50 times greater sensitivity than Chandra for extended sources. AXIS has a rapid repointing response with operations similar to Swift, but is 100 times more sensitive for time-domain science. These capabilities open up a vast discovery space and complement the next generation of astronomical observatories. A high-spectral-resolution mission (Athena) operating at the same time as a high-angular-resolution mission (AXIS) greatly increases the range of scientific discovery. AXIS will use lightweight X-ray optics made of thin single-crystal silicon mirrors developed at NASA Goddard. The detector array builds on a long legacy of X-ray CCD and provides improved photon localization, much faster readout time, and broader energy band. The estimated mission costs are consistent with the $1B Probe mission cost guideline.
△ Less
Submitted 14 March, 2019; v1 submitted 10 March, 2019;
originally announced March 2019.
-
Summary of the 13th IACHEC Meeting
Authors:
K. K. Madsen,
L. Natalucci,
G. Belanger,
C. E. Grant,
M. Guainazzi,
V. Kashyap,
H. L. Marshall,
E. D. Miller,
J. Nevalainen,
P. P. Plucinsky,
Y. Terada
Abstract:
We summarize the outcome of the 13th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC), held at Tenuta dei Ciclamini (Avigliano Umbro, Italy) in April 2018. Fifty-one scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the current status of the X-ray payload inter-calibration and…
▽ More
We summarize the outcome of the 13th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC), held at Tenuta dei Ciclamini (Avigliano Umbro, Italy) in April 2018. Fifty-one scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the current status of the X-ray payload inter-calibration and possible approaches to improve it. This summary consists of reports from the various working groups with topics ranging from the identification and characterization of standard calibration sources, multi-observatory cross-calibration campaigns, appropriate and new statistical techniques, calibration of instruments and characterization of background, and communication and preservation of knowledge and results for the benefit of the astronomical community.
△ Less
Submitted 3 January, 2019;
originally announced January 2019.
-
The Athena WFI Science Products Module
Authors:
David N. Burrows,
Steven Allen,
Marshall Bautz,
Esra Bulbul,
Julia Erdley,
Abraham D. Falcone,
Stanislav Fort,
Catherine E. Grant,
Sven Herrmann,
Jamie Kennea,
Robert Klar,
Ralph Kraft,
Adam Mantz,
Eric D. Miller,
Paul Nulsen,
Steve Persyn,
Pragati Pradhan,
Dan Wilkins
Abstract:
The Science Products Module (SPM), a US contribution to the Athena Wide Field Imager, is a highly capable secondary CPU that performs special processing on the science data stream. The SPM will have access to both accepted X-ray events and those that were rejected by the on-board event recognition processing. It will include two software modules. The Transient Analysis Module will perform on-board…
▽ More
The Science Products Module (SPM), a US contribution to the Athena Wide Field Imager, is a highly capable secondary CPU that performs special processing on the science data stream. The SPM will have access to both accepted X-ray events and those that were rejected by the on-board event recognition processing. It will include two software modules. The Transient Analysis Module will perform on-board processing of the science images to identify and characterize variability of the prime target and/or detection of serendipitous transient X-ray sources in the field of view. The Background Analysis Module will perform more sophisticated flagging of potential background events as well as improved background characterization, making use of data that are not telemetered to the ground, to provide improved background maps and spectra. We present the preliminary design of the SPM hardware as well as a brief overview of the software algorithms under development.
△ Less
Submitted 8 August, 2018;
originally announced August 2018.
-
Summary of the 12th IACHEC Meeting
Authors:
K. Forster,
C. E. Grant,
M. Guainazzi,
V. Kashyap,
H. L. Marshall,
E. D. Miller,
L. Natalucci,
J. Nevalainen,
P. P. Plucinsky,
Y. Terada
Abstract:
We summarize the outcome of the 12th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC), held at the UCLA conference center in Lake Arrowhead (California) in March 2017. 56 scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the X-ray payload inter-calibration, as wel…
▽ More
We summarize the outcome of the 12th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC), held at the UCLA conference center in Lake Arrowhead (California) in March 2017. 56 scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the X-ray payload inter-calibration, as well as possible ways to improve it. The "Thermal Supernovas Remnant" (SNR) Working Group presented a recently published paper on 1E0102.2-7219 as a calibration standard in the 0.5-1.0 keV band. A new method to measure the high-energy spectrum of the Crab Nebula and pulsar with NuSTAR without using its optics may yield a new absolute flux standard in the 3-7 keV band. A new ACIS contamination model - released with CALDB version 4.7.3 - leads to a significant improvement in modeling the spectral, spatial, and temporal properties of the contaminant. The first calibration results of the scientific payload on board Hitomi confirm the excellent performance of the instruments before the spacecraft operation problems leading to its loss. Finally, the meeting discussed extensively a novel statistic approach to formally identify in which direction the effective areas of different instruments would need to be changed to bring them into concordance. This method could inform future further calibration efforts.
△ Less
Submitted 4 August, 2017;
originally announced August 2017.
-
Summary of the 2014 IACHEC Meeting
Authors:
David Burrows,
Fabio Gastaldello,
Catherine E. Grant,
Matteo Guainazzi,
Kristin Madsen,
Eric Miller,
Jukka Nevalainen,
Paul P. Plucinsky,
Steve Sembay
Abstract:
We present the main results of the 9th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC), held in Warrenton (Virginia) in May 2014. Over 50 scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the X-ray payloads inter-calibration, as well as possible ways to improve i…
▽ More
We present the main results of the 9th meeting of the International Astronomical Consortium for High Energy Calibration (IACHEC), held in Warrenton (Virginia) in May 2014. Over 50 scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the X-ray payloads inter-calibration, as well as possible ways to improve it. Sect.2 of this Report summarises our current understanding of the energy-dependent inter-calibration status.
△ Less
Submitted 19 December, 2014;
originally announced December 2014.
-
Fifteen years of the Advanced CCD Imaging Spectrometer
Authors:
Catherine E. Grant,
Mark W. Bautz,
Peter G. Ford,
Paul P. Plucinsky
Abstract:
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory enters its fifteenth year of operation on orbit, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination and aging of the spacecraft in general. Here we present highlights from the in…
▽ More
As the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory enters its fifteenth year of operation on orbit, it continues to perform well and produce spectacular scientific results. The response of ACIS has evolved over the lifetime of the observatory due to radiation damage, molecular contamination and aging of the spacecraft in general. Here we present highlights from the instrument team's monitoring program and our expectations for the future of ACIS. The ACIS calibration source produces multiple line energies and fully illuminates the entire focal plane which has greatly facilitated the measurement of charge transfer inefficiency and absorption from contamination. While the radioactive decay of the source has decreased its utility, it continues to provide valuable data on the health of the instrument. Performance changes on ACIS continue to be manageable, and do not indicate any limitations on ACIS lifetime.
△ Less
Submitted 24 July, 2014;
originally announced July 2014.
-
Summary of the 2013 IACHEC Meeting
Authors:
Catherine E. Grant,
Matteo Guainazzi,
Lorenzo Natalucci,
Jukka Nevalainen,
Paul P. Plucinsky,
Andrew Pollock,
Steve Sembay
Abstract:
We present the main results of the 8th International Astronomical Consortium for High Energy Calibration (IACHEC) meeting, held in Theddingworth, Leicestershire, between March 25 and 28, 2013. Over 50 scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the X-ray payload inter-calibration, as well as possib…
▽ More
We present the main results of the 8th International Astronomical Consortium for High Energy Calibration (IACHEC) meeting, held in Theddingworth, Leicestershire, between March 25 and 28, 2013. Over 50 scientists directly involved in the calibration of operational and future high-energy missions gathered during 3.5 days to discuss the status of the X-ray payload inter-calibration, as well as possible ways to improve it. Sect. 4 of this Report summarises our current understanding of the energy-dependent inter-calibration status.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor II
Authors:
C. E. Grant,
P. G. Ford,
M. W. Bautz,
S. L. O'Dell
Abstract:
The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced…
▽ More
The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced the effectiveness of the on-board monitor. The ACIS team has developed an algorithm which uses data from the CCDs themselves to detect periods of high radiation and a flight software patch to apply this algorithm is currently active on-board the instrument. In this paper, we explore the ACIS response to particle radiation through comparisons to a number of external measures of the radiation environment. We hope to better understand the efficiency of the algorithm as a function of the flux and spectrum of the particles and the time-profile of the radiation event.
△ Less
Submitted 13 July, 2012;
originally announced July 2012.
-
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor
Authors:
C. E. Grant,
B. LaMarr,
M. W. Bautz,
S. L. O'Dell
Abstract:
The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons scattering off the x-ray telescope's mirrors. The primary effect of this damage was to increase the charge-transfer inefficiency (CTI) of the ACIS 8 front-illuminat…
▽ More
The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons scattering off the x-ray telescope's mirrors. The primary effect of this damage was to increase the charge-transfer inefficiency (CTI) of the ACIS 8 front-illuminated CCDs. Subsequently, the Chandra team implemented procedures to remove the ACIS from the telescope's focus during high-radiation events: planned protection during radiation-belt transits; autonomous protection triggered by an on-board radiation monitor; and manual intervention based upon assessment of space-weather conditions. However, as Chandra's multilayer insulation ages, elevated temperatures have reduced the effectiveness of the on-board radiation monitor for autonomous protection. Here we investigate using the ACIS CCDs themselves as a radiation monitor. We explore the 10-year database to evaluate the CCDs' response to particle radiation and to compare this response with other radiation data and environment models.
△ Less
Submitted 23 July, 2010;
originally announced July 2010.
-
Physics of reverse annealing in high-resistivity Chandra ACIS CCDs
Authors:
C. E. Grant,
B. LaMarr,
G. Y. Prigozhin,
S. E. Kissel,
S. K. Brown,
M. W. Bautz
Abstract:
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane wa…
▽ More
After launch, the Advanced CCD Imaging Spectrometer (ACIS), a focal plane instrument on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. An effect of the damage was to increase the charge transfer inefficiency (CTI) of the front illuminated CCDs. As part of the initial damage assessment, the focal plane was warmed from the operating temperature of -100C to +30C which unexpectedly further increased the CTI. We report results of ACIS CCD irradiation experiments in the lab aimed at better understanding this reverse annealing process. Six CCDs were irradiated cold by protons ranging in energy from 100 keV to 400 keV, and then subjected to simulated bakeouts in one of three annealing cycles. We present results of these lab experiments, compare them to our previous experiences on the ground and in flight, and derive limits on the annealing time constants.
△ Less
Submitted 10 July, 2008;
originally announced July 2008.
-
Temperature dependence of charge transfer inefficiency in Chandra X-ray CCDs
Authors:
C. E. Grant,
M. W. Bautz,
S. E. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magn…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate CTI and spectral resolution degradation. We present the initial temperature dependence of ACIS CTI from -120 to -60 degrees Celsius and the current temperature dependence after more than six years of continuing slow radiation damage. We use the change of shape of the temperature dependence to speculate on the nature of the damaging particles.
△ Less
Submitted 7 June, 2006;
originally announced June 2006.
-
Long-term trends in radiation damage of Chandra X-ray CCDs
Authors:
C. E. Grant,
M. W. Bautz,
S. M. Kissel,
B. LaMarr,
G. Y. Prigozhin
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. Current operations require ACIS to be protected during radiation belt passages to prevent this type of damage, but there remains a much slower and more gra…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. Current operations require ACIS to be protected during radiation belt passages to prevent this type of damage, but there remains a much slower and more gradual increase. We present the history of ACIS charge transfer inefficiency (CTI), and other measures of radiation damage, from January 2000 through June 2005. The rate of CTI increase is low, of order 1e-6 per year, with no indication of step-function increases due to specific solar events. Based on the time history and CCD location of the CTI increase, we speculate on the nature of the damaging particles.
△ Less
Submitted 1 September, 2005;
originally announced September 2005.
-
An Overview of the Performance of the Chandra X-Ray Observatory
Authors:
M. C. Weisskopf,
T. L. Aldcroft,
M. Bautz,
R. A. Cameron,
D. Dewey,
J. J. Drake,
C. E. Grant,
H. L. Marshall,
S. S. Murray
Abstract:
The Chandra X-ray Observatory is the X-ray component of NASA's Great Observatory Program which includes the recently launched Spitzer Infrared Telescope, the Hubble Space Telescope (HST) for observations in the visible, and the Compton Gamma-Ray Observatory (CGRO) which, after providing years of useful data has reentered the atmosphere. All these facilities provide, or provided, scientific data…
▽ More
The Chandra X-ray Observatory is the X-ray component of NASA's Great Observatory Program which includes the recently launched Spitzer Infrared Telescope, the Hubble Space Telescope (HST) for observations in the visible, and the Compton Gamma-Ray Observatory (CGRO) which, after providing years of useful data has reentered the atmosphere. All these facilities provide, or provided, scientific data to the international astronomical community in response to peer-reviewed proposals for their use. The Chandra X-ray Observatory was the result of the efforts of many academic, commercial, and government organizations primarily in the United States but also in Europe. NASA's Marshall Space Flight Center (MSFC) manages the Project and provides Project Science; Northrop Grumman Space Technology (NGST -- formerly TRW) served as prime contractor responsible for providing the spacecraft, the telescope, and assembling and testing the Observatory; and the Smithsonian Astrophysical Observatory (SAO) provides technical support and is responsible for ground operations including the Chandra X-ray Center (CXC). Telescope and instrument teams at SAO, the Massachusetts Institute of Technology (MIT), the Pennsylvania State University (PSU), the Space Research Institute of the Netherlands (SRON), the Max-Planck Institut fur extraterrestrische Physik (MPE), and the University of Kiel also provide technical support to the Chandra Project. We present here a detailed description of the hardware, its on-orbit performance, and a brief overview of some of the remarkable discoveries that illustrate that performance.
△ Less
Submitted 15 March, 2005;
originally announced March 2005.
-
A charge transfer inefficiency correction model for the Chandra Advanced CCD Imaging Spectrometer
Authors:
C. E. Grant,
M. W. Bautz,
S. M. Kissel,
B. LaMarr
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magn…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The primary effect of the damage was to increase the charge transfer inefficiency (CTI) of the eight front illuminated CCDs by more than two orders of magnitude. The ACIS instrument team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate CTI and spectral resolution degradation. We will discuss the characteristics of the damage, the detector and the particle background and how they conspire to degrade the instrument performance. We have developed a model for ACIS CTI which can be used to correct each event and regain some of the lost performance. The correction uses a map of the electron trap distribution, a parameterization of the energy dependent charge loss and the fraction of the lost charge re-emitted into the trailing pixel to correct the pixels in the event island. This model has been implemented in the standard Chandra data processing pipeline. Some of the correction algorithm was inspired by the earlier work on ACIS CTI correction by Townsley et al. (2000; 2002). The details of the CTI model and how each parameter improves performance will be discussed, as well as the limitations and the possibilities for future improvement.
△ Less
Submitted 9 July, 2004;
originally announced July 2004.
-
Composition of the Chandra ACIS contaminant
Authors:
Herman L. Marshall,
Allyn Tennant,
Catherine E. Grant,
Adam P. Hitchcock,
Steve O'Dell,
Paul P. Plucinsky
Abstract:
The Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory is suffering a gradual loss of low energy sensitivity due to a buildup of a contaminant. High resolution spectra of bright astrophysical sources using the Chandra Low Energy Transmission Grating Spectrometer (LETGS) have been analyzed in order to determine the nature of the contaminant by measuring the absorption edges…
▽ More
The Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory is suffering a gradual loss of low energy sensitivity due to a buildup of a contaminant. High resolution spectra of bright astrophysical sources using the Chandra Low Energy Transmission Grating Spectrometer (LETGS) have been analyzed in order to determine the nature of the contaminant by measuring the absorption edges. The dominant element in the contaminant is carbon. Edges due to oxygen and fluorine are also detectable. Excluding H, we find that C, O, and F comprise >80%, 7%, and 7% of the contaminant by number, respectively. Nitrogen is less than 3% of the contaminant. We will assess various candidates for the contaminating material and investigate the growth of the layer with time. For example, the detailed structure of the C-K absorption edge provides information about the bonding structure of the compound, eliminating aromatic hydrocarbons as the contaminating material.
△ Less
Submitted 19 August, 2003;
originally announced August 2003.
-
Detection of x-rays from galaxy groups associated with the gravitationally lensed systems PG 1115+080 and B1422+231
Authors:
C. E. Grant,
M. W. Bautz,
G. Chartas,
G. P. Garmire
Abstract:
Gravitational lenses that produce multiple images of background quasars can be an invaluable cosmological tool. Deriving cosmological parameters, however, requires modeling the potential of the lens itself. It has been estimated that up to a quarter of lensing galaxies are associated with a group or cluster which perturbs the gravitational potential. Detection of X-ray emission from the group or…
▽ More
Gravitational lenses that produce multiple images of background quasars can be an invaluable cosmological tool. Deriving cosmological parameters, however, requires modeling the potential of the lens itself. It has been estimated that up to a quarter of lensing galaxies are associated with a group or cluster which perturbs the gravitational potential. Detection of X-ray emission from the group or cluster can be used to better model the lens. We report on the first detection in X-rays of the group associated with the lensing system PG 1115+080 and the first X-ray image of the group associated with the system B1422+231. We find a temperature and rest-frame luminosity of 0.8 +/- 0.1 keV and 7 +/- 2 x 10^{42} ergs/s for PG 1115+080 and 1.0 +infty/-0.3 keV and 8 +/- 3 x 10^{42} ergs/s for B1422+231. We compare the spatial and spectral characteristics of the X-ray emission to the properties of the group galaxies, to lens models, and to the general properties of groups at lower redshift.
△ Less
Submitted 14 April, 2004; v1 submitted 8 May, 2003;
originally announced May 2003.
-
Chandra Spectra of the Soft X-ray Diffuse Background
Authors:
M. Markevitch,
M. W. Bautz,
B. Biller,
Y. Butt,
R. Edgar,
T. Gaetz,
G. Garmire,
C. E. Grant,
P. Green,
M. Juda,
P. P. Plucinsky,
D. Schwartz,
R. Smith,
A. Vikhlinin,
S. Virani,
B. J. Wargelin,
S. Wolk
Abstract:
We present an exploratory Chandra ACIS-S3 study of the diffuse component of the Cosmic X-ray Background in the 0.3-7 keV band for four directions at high Galactic latitudes, with emphasis on details of the ACIS instrumental background modeling. Observations of the dark Moon are used to model the detector background. A comparison of the Moon data and the data obtained with ACIS stowed outside the…
▽ More
We present an exploratory Chandra ACIS-S3 study of the diffuse component of the Cosmic X-ray Background in the 0.3-7 keV band for four directions at high Galactic latitudes, with emphasis on details of the ACIS instrumental background modeling. Observations of the dark Moon are used to model the detector background. A comparison of the Moon data and the data obtained with ACIS stowed outside the focal area showed that the dark Moon does not emit significantly in our band. Point sources down to 3 10^-16 erg/s/cm2 in the 0.5-2 keV band are excluded in our two deepest observations. We estimate the contribution of fainter, undetected sources to be less than 20% of the remaining CXB flux in this band in all four pointings. In the 0.3-1 keV band, the diffuse signal varies strongly from field to field and contributes between 55% and 90% of the total CXB signal. It is dominated by emission lines that can be modeled by a kT=0.1-0.4 keV plasma. In particular, the two fields located away from bright Galactic features show a prominent line blend at E=580 eV (O VII + O VIII) and a possible line feature at E~300 eV. The two pointings toward the North Polar Spur exhibit a brighter O blend and additional bright lines at 730-830 eV (Fe XVII). We measure the total 1-2 keV flux of (1.0-1.2 +-0.2) 10^-15 erg/s/cm2/arcmin (mostly resolved), and the 2-7 keV flux of (4.0-4.5 +-1.5) 10^-15 erg/s/cm2/arcmin. At E>2 keV, the diffuse emission is consistent with zero, to an accuracy limited by the short Moon exposure and systematic uncertainties of the S3 background. Assuming Galactic or local origin of the line emission, we put an upper limit of 3 10^-15 erg/s/cm2/arcmin on the 0.3-1 keV extragalactic diffuse flux.
△ Less
Submitted 28 October, 2002; v1 submitted 20 September, 2002;
originally announced September 2002.
-
The Flight Spectral Response of the ACIS Instrument
Authors:
Paul P. Plucinsky,
Norbert S. Schulz,
Herman L. Marshall,
Catherine E. Grant,
George Chartas,
Divas Sanwal,
Marcus A. Teter,
Alexey A. Vikhlinin,
Richard J. Edgar,
Michael W. Wise,
Glenn E. Allen,
Shanil N. Virani,
Joseph M. DePasquale,
Michael T. Raley
Abstract:
We discuss the flight calibration of the spectral response of the Advanced CCD Imaging Spectrometer (ACIS) on-board the Chandra X-ray Observatory (CXO). The spectral resolution and sensitivity of the ACIS instrument have both been evolving over the course of the mission. The spectral resolution of the frontside-illuminated (FI) CCDs changed dramatically in the first month of the mission due to r…
▽ More
We discuss the flight calibration of the spectral response of the Advanced CCD Imaging Spectrometer (ACIS) on-board the Chandra X-ray Observatory (CXO). The spectral resolution and sensitivity of the ACIS instrument have both been evolving over the course of the mission. The spectral resolution of the frontside-illuminated (FI) CCDs changed dramatically in the first month of the mission due to radiation damage. Since that time, the spectral resolution of the FI CCDs and the backside-illuminated (BI) CCDs have evolved gradually with time. We demonstrate the efficacy of charge-transfer inefficiency (CTI) correction algorithms which recover some of the lost performance. The detection efficiency of the ACIS instrument has been declining throughout the mission, presumably due to a layer of contamination building up on the filter and/or CCDs. We present a characterization of the energy dependence of the excess absorption and demonstrate software which models the time dependence of the absorption from energies of 0.4 keV and up. The spectral redistribution function and the detection efficiency are well-characterized at energies from 1.5 to 8.0 keV. The calibration at energies below 1.5 keV is challenging because of the lack of strong lines in the calibration source and also because of the inherent non-linear dependence with energy of the CTI and the absorption by the contamination layer. We have been using data from celestial sources with relatively simple spectra to determine the quality of the calibration below 1.5 keV. The analysis of these observations demonstrate that the CTI correction recovers a significant fraction of the spectral resolution of the FI CCDs and the models of the time-dependent absorption result in consistent measurements of the flux at low energies for data from a BI (S3) CCD.
△ Less
Submitted 24 September, 2002; v1 submitted 9 September, 2002;
originally announced September 2002.
-
Sacrificial charge and the spectral resolution performance of the Chandra Advanced CCD Imaging Spectrometer
Authors:
Catherine E. Grant,
Gregory Y. Prigozhin,
Beverly LaMarr,
Mark W. Bautz
Abstract:
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate charge transfer inefficiency (CTI)…
▽ More
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation belts. The ACIS team is continuing to study the properties of the damage with an emphasis on developing techniques to mitigate charge transfer inefficiency (CTI) and spectral resolution degradation. A post-facto CTI corrector has been developed which can effectively recover much of the lost resolution. Any further improvements in performance will require knowledge of the location and amount of sacrificial charge - charge deposited along the readout path of an event which fills electron traps and changes CTI. We report on efforts by the ACIS Instrument team to characterize which charge traps cause performance degradation and the properties of the sacrificial charge seen on-orbit. We also report on attempts to correct X-ray pulseheights for the presence of sacrificial charge.
△ Less
Submitted 6 September, 2002;
originally announced September 2002.
-
The temporal characteristics of the Chandra X-ray Observatory high energy particle background
Authors:
Catherine E. Grant,
Mark W. Bautz,
Shanil N. Virani
Abstract:
It was observed early on in the Chandra X-ray Observatory mission that the background rates of the Advanced CCD Imaging Spectrometer (ACIS) were highly variable on both short and long timescales. We present analysis of lightcurves of the high energy (> 15 keV) ACIS background spanning most of the mission lifetime. These high energy events are not produced by astrophysical X-rays, but by the part…
▽ More
It was observed early on in the Chandra X-ray Observatory mission that the background rates of the Advanced CCD Imaging Spectrometer (ACIS) were highly variable on both short and long timescales. We present analysis of lightcurves of the high energy (> 15 keV) ACIS background spanning most of the mission lifetime. These high energy events are not produced by astrophysical X-rays, but by the particle background, primarily energetic protons. Temporal characteristics of both the quiescent background and background flares will be discussed as well as correlations with Chandra's orbital position and the solar activity cycle. The strength and frequency of background flares appear cyclic with a quasi-annual period, most likely from the motion of Chandra's orbit through the geomagnetic environment.
△ Less
Submitted 4 February, 2002;
originally announced February 2002.
-
Analysis of On-Orbit ACIS Squeegee Mode Data on Chip I0
Authors:
Shanil N. Virani,
Paul P. Plucinsky,
Catherine E. Grant,
Beverly LaMarr
Abstract:
The MIT and CXC ACIS teams have explored a number of measures to ameliorate the effects of radiation damage suffered by the ACIS FI CCDs. One of these measures is a novel CCD read-out method called ``squeegee mode''. A variety of different implementations of the squeegee mode have now been tested on the I0 CCD.
Our results for the fitted FWHM at Al-K$α$ and Mn-K$α$ clearly demonstrate that all…
▽ More
The MIT and CXC ACIS teams have explored a number of measures to ameliorate the effects of radiation damage suffered by the ACIS FI CCDs. One of these measures is a novel CCD read-out method called ``squeegee mode''. A variety of different implementations of the squeegee mode have now been tested on the I0 CCD.
Our results for the fitted FWHM at Al-K$α$ and Mn-K$α$ clearly demonstrate that all the squeegee modes provide improved performance in terms of reducing CTI and improving spectral resolution. Our analysis of the detection efficiency shows that the so-called squeegee modes ``Vanilla'' and ``Maximum Observing Efficiency'' provide the same detection efficiency as the standard clocking, once the decay in the intensity of the radioactive source has been taken into account. The squeegee modes which utilize the slow parallel transfer (``Maximum Spectral Resolution'', ``Maximum Angular Resolution'', and ``Sub-Array'') show a significantly lower detection efficiency than the standard clocking. The slow parallel transfer squeegee modes exhibit severe grade migration from flight grade 0 to flight grade 64 and a smaller migration into ASCA g7. The latter effect can explain some of the drop in detection efficiency. (ABRIDGED ABSTRACT)
△ Less
Submitted 3 December, 2001;
originally announced December 2001.
-
Distances to the high galactic latitude molecular clouds G192-67 and MBM 23-24
Authors:
Catherine E. Grant,
David N. Burrows
Abstract:
We report on distance determinations for two high Galactic latitude cloud complexes, G192-67 and MBM 23-24. No distance determination exists in the literature for either cloud. Thirty-four early type stars were observed towards the two clouds, more than half of which have parallaxes measured by the Hipparcos satellite. For the remaining stars we have made spectroscopic distance estimates. The da…
▽ More
We report on distance determinations for two high Galactic latitude cloud complexes, G192-67 and MBM 23-24. No distance determination exists in the literature for either cloud. Thirty-four early type stars were observed towards the two clouds, more than half of which have parallaxes measured by the Hipparcos satellite. For the remaining stars we have made spectroscopic distance estimates. The data consist of high resolution echelle spectra centered on the Na I D lines, and were obtained over six nights at the Coude Feed telescope at Kitt Peak National Observatory. Interstellar absorption lines were detected towards some of the stars, enabling estimates of the distances to the clouds of 109 +/- 14 pc for G192-67, and of 139 +/- 33 pc for MBM 23-24. We discuss the relationship of these clouds to other ISM features such as the Local Hot Bubble and the local cavity in neutral hydrogen.
△ Less
Submitted 4 February, 1999;
originally announced February 1999.