-
Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
C. Goodman,
M. Guzzetti,
C. Hanretty,
S. Lee,
G. Leum,
L. J. Rosenberg,
G. Rybka,
J. Sinnis,
D. Zhang,
M. H. Awida,
D. Bowring,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
R. Khatiwada,
J. Brodsky,
G. Carosi,
L. D. Duffy
, et al. (31 additional authors not shown)
Abstract:
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion se…
▽ More
The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.
△ Less
Submitted 13 November, 2023;
originally announced November 2023.
-
The Multi-mode Acoustic Gravitational Wave Experiment: MAGE
Authors:
William M. Campbell,
Maxim Goryachev,
Michael E. Tobar
Abstract:
The Multi-mode Acoustic Gravitational wave Experiment (MAGE) is a high frequency gravitational wave detection experiment. In its first stage, the experiment features two near-identical quartz bulk acoustic wave resonators that act as strain antennas with spectral sensitivity as low as $6.6\times 10^{-21} \left[\textrm{strain}\right]/\sqrt{\textrm{Hz}}$ in multiple narrow bands across MHz frequenci…
▽ More
The Multi-mode Acoustic Gravitational wave Experiment (MAGE) is a high frequency gravitational wave detection experiment. In its first stage, the experiment features two near-identical quartz bulk acoustic wave resonators that act as strain antennas with spectral sensitivity as low as $6.6\times 10^{-21} \left[\textrm{strain}\right]/\sqrt{\textrm{Hz}}$ in multiple narrow bands across MHz frequencies. MAGE is the successor to the initial path-finding experiments; GEN 1 and GEN 2. These precursor runs demonstrated the successful use of the technology, employing a single quartz gravitational wave detector that found significantly strong and rare transient features. As the next step to this initial experiment, MAGE will employ further systematic rejection strategies by adding an additional quartz detector such that localised strains incident on just a single detector can be identified. The primary goals of MAGE will be to target signatures arising from objects and/or particles beyond that of the standard model, as well as identifying the source of the rare events seen in the predecessor experiment. The experimental set-up, current status and future directions for MAGE are discussed. Calibration procedures of the detector and signal amplification chain are presented. The sensitivity of MAGE to gravitational waves is estimated from knowledge of the quartz resonators. Finally, MAGE is assembled and tested in order to determine the thermal state of its new components.
△ Less
Submitted 23 November, 2023; v1 submitted 2 July, 2023;
originally announced July 2023.
-
Searching for GUT-scale QCD Axions and Monopoles with a High Voltage Capacitor
Authors:
Michael E. Tobar,
Anton V. Sokolov,
Andreas Ringwald,
Maxim Goryachev
Abstract:
The QCD axion has been postulated to exist because it solves the strong CP problem. Furthermore, if it exists axions should be created in the early Universe and could account for all the observed dark matter. In particular, axion masses of order $10^{-10}$ to $10^{-7}$ eV correspond to axions in the vicinity of the GUT-scale. In this mass range many experiments have been proposed to search for the…
▽ More
The QCD axion has been postulated to exist because it solves the strong CP problem. Furthermore, if it exists axions should be created in the early Universe and could account for all the observed dark matter. In particular, axion masses of order $10^{-10}$ to $10^{-7}$ eV correspond to axions in the vicinity of the GUT-scale. In this mass range many experiments have been proposed to search for the axion through the standard QED coupling parameter $g_{aγγ}$. Recently axion electrodynamics has been expanded to include two more coupling parameters, $g_{aEM}$ and $g_{aMM}$, which could arise if heavy magnetic monopoles exist. In this work we show that both $g_{aMM}$ and $g_{aEM}$ may be searched for using a high voltage capacitor. Since the experiment is not sensitive to $g_{aγγ}$, it gives a new way to search for effects of heavy monopoles if the GUT-scale axion is shown to exist, or to simultaneously search for both the axion and the monopole at the same time.
△ Less
Submitted 2 August, 2023; v1 submitted 23 June, 2023;
originally announced June 2023.
-
Comparing Instrument Spectral Sensitivity of Dissimilar Electromagnetic Haloscopes to Axion Dark Matter and High Frequency Gravitational Waves
Authors:
Michael E. Tobar,
Catriona A. Thomson,
William M. Campbell,
Aaron Quiskamp,
Jeremy F. Bourhill,
Benjamin T. McAllister,
Eugene N. Ivanov,
Maxim Goryachev
Abstract:
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon thet…
▽ More
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon theta angle. Thus, after calculating the sensitivity of a haloscope to an axion signal, we also have calculated the order of magnitude sensitivity to a gravitational wave signal of the same spectral and temporal form. However, it is unlikely that a gravitational wave and an axion signal will be of the same form, since physically the way the signals are generated are completely different. For gravitational wave detection, the spectral strain sensitivity is in units strain per square root Hz, is the natural way to compare the sensitivity of gravitational wave detectors due to its independence on the gravitational wave signal. In this work, we introduce a systematic way to calculate the spectral sensitivity of an axion haloscope, so instrument comparison may be achieved independent of signal assumptions and only depends on the axion to signal transduction sensitivity and noise in the instrument. Thus, the calculation of the spectral sensitivity not only allows the comparison of dissimilar axion detectors independent of signal, but also allows us to compare the order of magnitude gravitational wave sensitivity in terms of spectral strain sensitivity, allowing comparisons to standard gravitational wave detectors based on optical interferometers and resonant-mass technology.
△ Less
Submitted 16 October, 2022; v1 submitted 7 September, 2022;
originally announced September 2022.
-
Searching for Ultra-Light Axions with Twisted Cavity Resonators of Anyon Rotational Symmetry with Bulk Modes of Non-Zero Helicity
Authors:
J. F. Bourhill,
E. C. I. Paterson,
M. Goryachev,
M. E. Tobar
Abstract:
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow…
▽ More
Möbius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the Möbius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow structures using equilateral triangular cross-sections, which leads to the realization of a cavity with anyon rotational symmetry. Unlike all previous cavity resonators, the anyon resonator permits the existence of bulk resonant modes that exhibit non-zero electromagnetic helicity in vacuo, with a non-zero overlap of the electric and magnetic mode eigenvectors, $\int \mathbf{E}_p\cdot\mathbf{B}_p~dτ$, integrated over the cavity volume. In the upconversion limit, we show that these non-zero helical modes couple naturally to ultra-light dark matter axions within the bandwidth of the resonator by adding amplitude-modulated sidebands through the axion-photon chiral anomaly. Thus, we show a sensitive ultra-light dark matter experiment may be realized by implementing such a resonator in an ultra-stable oscillator configuration and searching for signals in the Fourier spectrum of amplitude fluctuations. This removes the typical requirement for an external magnetic field and therefore permits the use of superconducting materials to reduce surface losses and enhance sensitivity to axions.
△ Less
Submitted 9 August, 2023; v1 submitted 1 August, 2022;
originally announced August 2022.
-
Direct Search for Dark Matter Axions Excluding ALP Cogenesis in the 63-67 micro-eV Range, with The ORGAN Experiment
Authors:
Aaron P. Quiskamp,
Ben T. McAllister,
Paul Altin,
Eugene N. Ivanov,
Maxim Goryachev,
Michael E. Tobar
Abstract:
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situat…
▽ More
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situated in Perth, Australia) is a microwave cavity axion haloscope that aims to search the majority of the mass range predicted by the SMASH model. Here we present results of Phase 1a, the first experiment to scan and search for axions in the microwave Ku Band. Our initial scan sets a new limit on the coupling of axions to two photons of $g_{aγγ}\geq 3\times 10^{-12}\, \textrm{GeV}^{-1}$ over the mass range $63.2$ to $67.1~μ$eV with $95\%$ confidence. This result is the most sensitive to date in this mass range, sufficient to exclude the well motivated ALP (Axion Like Particle) cogenesis model for dark matter, which adds ALPs to the standard model in the early universe to simultaneously explain the observed baryon and dark matter densities. To attain this level of sensitivity we utilised a TM$_{010}$ cylindrical cavity resonator, scanned between 15.28 to 16.23 GHz through the utilisation of a tuning rod. Measurements were performed over a duration of 3.5 weeks with a $74\%$ duty cycle, with the resonator coupled to a low noise HEMT amplifier and placed inside a superconducting solenoidal electromagnet of 11.5 Tesla in magnetic field strength.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier
Authors:
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason,
A. T. Hipp,
S. Jois,
P. Sikivie
, et al. (26 additional authors not shown)
Abstract:
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search.…
▽ More
We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $μ$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
△ Less
Submitted 15 October, 2021;
originally announced October 2021.
-
Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~μ$eV Mass Range
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
E. Burns,
R. Cervantes,
N. Crisosto,
N. Du,
H. Korandla,
G. Leum,
P. Mohapatra,
T. Nitta,
L. J Rosenberg,
G. Rybka,
J. Yang,
John Clarke,
I. Siddiqi,
A. Agrawal,
A. V. Dixit,
M. H. Awida,
A. S. Chou,
M. Hollister,
S. Knirck,
A. Sonnenschein,
W. Wester,
J. R. Gleason
, et al. (27 additional authors not shown)
Abstract:
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temp…
▽ More
We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~μ$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.
△ Less
Submitted 29 December, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.
-
Poynting vector controversy in axion modified electrodynamics
Authors:
Michael E Tobar,
Ben T McAllister,
Maxim Goryachev
Abstract:
The most sensitive haloscopes that search for axion dark matter through the two photon electromagnetic anomaly, convert axions into photons through the mixing of axions with a large DC magnetic field. In this work we apply Poynting theorem to the resulting axion modified electrodynamics and identify two possible Poynting vectors, one similar to the Abraham Poynting vector and the other to the Mink…
▽ More
The most sensitive haloscopes that search for axion dark matter through the two photon electromagnetic anomaly, convert axions into photons through the mixing of axions with a large DC magnetic field. In this work we apply Poynting theorem to the resulting axion modified electrodynamics and identify two possible Poynting vectors, one similar to the Abraham Poynting vector and the other to the Minkowski Poynting vector in electrodynamics. The latter picks up the extra non-conservative terms while the former does not. To understand the source of energy conversion and power flow in the detection systems, we apply the two Poynting theorems to axion modified electrodynamics, for both the resonant cavity and broadband low-mass axion detectors. We show that both Poynting theorems give the same sensitivity for a resonant cavity axion haloscope, but predict markedly different sensitivity for a low-mass broadband capacitive haloscope. Hence we ask the question, can understanding which one is the correct one for axion dark matter detection, be considered under the framework of the Abraham-Minkowski controversy? In reality, this should be confirmed by experiment when the axion is detected. However, many electrodynamic experiments have ruled in favour of the Minkowski Poynting vector when considering the canonical momentum in dielectric media. In light of this, we show that the axion modified Minkowski Poynting vector should indeed be taken seriously for sensitivity calculation for low-mass axion haloscope detectors in the quasi static limit, and predict orders of magnitude better sensitivity than the Abraham Poynting vector equivalent.
△ Less
Submitted 10 November, 2022; v1 submitted 9 September, 2021;
originally announced September 2021.
-
Rare Events Detected with a Bulk Acoustic Wave High Frequency Gravitational Wave Antenna
Authors:
Maxim Goryachev,
William M. Campbell,
Ik Siong Heng,
Serge Galliou,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5…
▽ More
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5.506 MHz was monitored, while in Run 1 the second mode was chosen to be the 5th OT of the slow shear mode (5C) operating at 8.392 MHz. However, in Run 2 the second mode was selected to be closer in frequency to the first mode, and chosen to be the 3rd overtone of the slow shear mode (3C) operating at 4.993 MHz. Two strong events were observed as transients responding to energy deposition within acoustic modes of the cavity. The first event occurred during Run 1 on the 12/05/2019 (UTC), and was observed in the 5.506 MHz mode, while the second mode at 8.392 MHz observed no event. During Run 2, a second event occurred on the 27/11/2019(UTC) and was observed by both modes. Timing of the events were checked against available environmental observations as well as data from other detectors. Various possibilities explaining the origins of the events are discussed.
△ Less
Submitted 22 July, 2021; v1 submitted 11 February, 2021;
originally announced February 2021.
-
Challenges and Opportunities of Gravitational Wave Searches at MHz to GHz Frequencies
Authors:
N. Aggarwal,
O. D. Aguiar,
A. Bauswein,
G. Cella,
S. Clesse,
A. M. Cruise,
V. Domcke,
D. G. Figueroa,
A. Geraci,
M. Goryachev,
H. Grote,
M. Hindmarsh,
F. Muia,
N. Mukund,
D. Ottaway,
M. Peloso,
F. Quevedo,
A. Ricciardone,
J. Steinlechner,
S. Steinlechner,
S. Sun,
M. E. Tobar,
F. Torrenti,
C. Unal,
G. White
Abstract:
The first direct measurement of gravitational waves by the LIGO and Virgo collaborations has opened up new avenues to explore our Universe. This white paper outlines the challenges and gains expected in gravitational wave searches at frequencies above the LIGO/Virgo band, with a particular focus on Ultra High-Frequency Gravitational Waves (UHF-GWs), covering the MHz to GHz range. The absence of kn…
▽ More
The first direct measurement of gravitational waves by the LIGO and Virgo collaborations has opened up new avenues to explore our Universe. This white paper outlines the challenges and gains expected in gravitational wave searches at frequencies above the LIGO/Virgo band, with a particular focus on Ultra High-Frequency Gravitational Waves (UHF-GWs), covering the MHz to GHz range. The absence of known astrophysical sources in this frequency range provides a unique opportunity to discover physics beyond the Standard Model operating both in the early and late Universe, and we highlight some of the most promising gravitational sources. We review several detector concepts which have been proposed to take up this challenge, and compare their expected sensitivity with the signal strength predicted in various models. This report is the summary of the workshop "Challenges and opportunities of high-frequency gravitational wave detection" held at ICTP Trieste, Italy in October 2019, that set up the stage for the recently launched Ultra-High-Frequency Gravitational Wave (UHF-GW) initiative.
△ Less
Submitted 13 December, 2021; v1 submitted 24 November, 2020;
originally announced November 2020.
-
Axion Dark Matter eXperiment: Run 1B Analysis Details
Authors:
ADMX Collaboration,
C. Bartram,
T. Braine,
R. Cervantes,
N. Crisosto,
N. Du,
G. Leum,
L. J Rosenberg,
G. Rybka,
J. Yang,
D. Bowring,
A. S. Chou,
R. Khatiwada,
A. Sonnenschein,
W. Wester,
G. Carosi,
N. Woollett,
L. D. Duffy,
M. Goryachev,
B. McAllister,
M. E. Tobar,
C. Boutan,
M. Jones,
B. H. Laroque,
N. S. Oblath
, et al. (23 additional authors not shown)
Abstract:
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire fre…
▽ More
Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for Run 1B, motivating analysis choices informed by details specific to this run.
△ Less
Submitted 13 October, 2020;
originally announced October 2020.
-
Gravitational wave detectors with broadband high frequency sensitivity
Authors:
Michael A. Page,
Maxim Goryachev,
Haixing Miao,
Yanbei Chen,
Yiqiu Ma,
David Mason,
Massimiliano Rossi,
Carl D. Blair,
Li Ju,
David G. Blair,
Albert Schliesser,
Michael E. Tobar,
Chunnong Zhao
Abstract:
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Res…
▽ More
The binary neutron star coalescence GW170817 was observed by gravitational wave detectors during the inspiral phase but sensitivity in the 1-5 kHz band was insufficient to observe the expected nuclear matter signature of the merger itself, and the process of black hole formation. This provides strong motivation for improving 1--5 kHz sensitivity which is currently limited by photon shot noise. Resonant enhancement by signal recycling normally improves the signal to noise ratio at the expense of bandwidth. The concept of optomechanical white light signal recycling (WLSR) has been proposed, but all schemes to date have been reliant on the development of suitable ultra-low mechanical loss components. Here for the first time we show demonstrated optomechanical resonator structures that meet the loss requirements for a WLSR interferometer with strain sensitivity below 10$^{-24}$ Hz$^{-1/2}$ at a few kHz. Experimental data for two resonators are combined with analytic models of 4km interferometers similar to LIGO, to demonstrate sensitivity enhancement across a much broader band of neutron star coalescence frequencies than dual-recycled Fabry-Perot Michelson detectors of the same length. One candidate resonator is a silicon nitride membrane acoustically isolated from the environment by a phononic crystal. The other is a single-crystal quartz lens that supports bulk acoustic longitudinal waves. Optical power requirements could prefer the membrane resonator, although the bulk acoustic wave resonator gives somewhat better thermal noise performance. Both could be implemented as add-on components to existing detectors.
△ Less
Submitted 17 July, 2020;
originally announced July 2020.
-
Broadband Electrical Action Sensing Techniques with conducting wires for low-mass dark matter axion detection
Authors:
Michael Edmund Tobar,
Ben T. McAllister,
Maxim Goryachev
Abstract:
Due to the inverse Primakoff effect it has been shown that when axions interact with a DC magnetic B-field the resulting electrical action will produce an AC electromotive force which oscillates at the Compton frequency of the axion, and may be modeled as an oscillating effective impressed magnetic current boundary source. We use this result to calculate the sensitivity of new experiments to low-m…
▽ More
Due to the inverse Primakoff effect it has been shown that when axions interact with a DC magnetic B-field the resulting electrical action will produce an AC electromotive force which oscillates at the Compton frequency of the axion, and may be modeled as an oscillating effective impressed magnetic current boundary source. We use this result to calculate the sensitivity of new experiments to low-mass axions using the quasi-static technique. First, we calculate the current induced in an electric dipole antenna (straight conducting wire) when the DC B-field is spatially constant and show that it has a sensitivity proportional to the axion mass. Following this we extend the topology by making use of the full extent of the spatially varying DC B-field. This extension is achieved by transforming the 1D conducting wire to a 2D winding, to fully link the effective magnetic current boundary source and thus couple to the full axion induced electrical action. In this case the conductor becomes a coil winding where the voltage induced across the winding increases proportionally to the number of windings. We investigate two different topologies: The 1st uses a single winding, and couples to the effective short circuit current generated in the winding, which is read out using a sensitive low impedance SQUID amplifier: The 2nd uses multiple windings, with every turn effectively increasing the the voltage output proportional to the winding number. The read out of this configuration is optimised by implementing a cryogenic low-noise high input impedance voltage amplifier. The end result is a new Broadband Electrical Action Sensing Techniques with orders of magnitude improved sensitivity, which is linearly proportional to the axion photon coupling and capable of detecting QCD dark matter axions.
△ Less
Submitted 10 June, 2020; v1 submitted 15 April, 2020;
originally announced April 2020.
-
Modified Axion Electrodynamics as Impressed Electromagnetic Sources Through Oscillating Background Polarization and Magnetization
Authors:
Michael Edmund Tobar,
Ben T. McAllister,
Maxim Goryachev
Abstract:
We present a reformulation of axion modified electrodynamics with all modifications redefined within the constitutive relations between the D,H,B and E fields. This allows the interpretation of the axion induced background bound charge, polarization current and background polarization and magnetization satisfying the charge-current continuity equation. This representation is of similar form to pho…
▽ More
We present a reformulation of axion modified electrodynamics with all modifications redefined within the constitutive relations between the D,H,B and E fields. This allows the interpretation of the axion induced background bound charge, polarization current and background polarization and magnetization satisfying the charge-current continuity equation. This representation is of similar form to photon sector odd-parity Lorentz invariance violating background fields. We show that when a DC B-field is applied an oscillating background polarization is induced at a frequency equivalent to the axion mass. In contrast, when DC E-field is applied, an oscillating background magnetization is induced at a frequency equivalent to the axion mass. We show that these terms are equivalent to impressed source terms, analogous to the way that voltage and current sources are impressed into Maxwell's equations in circuit and antenna theory. The impressed source terms represent the conversion of external energy into electromagnetic energy, and in the case of axion modified electrodynamics this is due to the inverse Primakoff effect converting energy from axions into photons. The axion induced oscillating polarization under a DC magnetic field is analogous to a permanent polarised electret oscillating at the axion Compton frequency, which sources an electromotive force from an effective impressed magnetic current source. In particular, it is shown that the impressed electrical DC current that drives the solenoidal magnetic DC field of an electromagnet, induces an impressed magnetic current parallel to the DC electrical current, oscillating at the Compton frequency of the axion. We show that the magnetic current drives a voltage source through an electric vector potential and also defines the boundary condition of the oscillating axion induced polarization inside and outside the electromagnet.
△ Less
Submitted 31 July, 2019; v1 submitted 5 September, 2018;
originally announced September 2018.