Skip to main content

Showing 1–9 of 9 results for author: Golovko, V V

  1. arXiv:2310.06867  [pdf, other

    physics.geo-ph astro-ph.IM nucl-ex physics.ao-ph

    Application of the Most Frequent Value Method for $^{39}$Ar Half-Life Determination

    Authors: Victor V. Golovko

    Abstract: An evaluation method supported by robust statistical analysis was used to analyze historical measurements of $^{39}$Ar half-life. The method, which combines the most frequent value (MFV) approach with bootstrap analysis, provides a more reliable way to estimate the half-life of $^{39}$Ar. The results show that the half-life is T1/2(MFV) = 268.2 + (3.1) - (2.9) years, with an uncertainty correspond… ▽ More

    Submitted 6 October, 2023; originally announced October 2023.

    Comments: accepted for publication in the European Physical Journal C (19 pages, 2 tables, 5 figures)

  2. arXiv:2302.04952  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Ambient Dose and Dose Rate Measurement in SNOLAB Underground Laboratory at Sudbury, Ontario, Canada

    Authors: Victor V. Golovko, Oleg Kamaev, Jiansheng Sun, Chris J. Jillings, Pierre Gorel, Eric Vazquez-Jauregui

    Abstract: The paper describes a system and experimental procedure that use integrating passive detectors, such as thermoluminescent dosimeters (TLDs), for the measurement of ultra-low-level ambient dose equivalent rate values at the underground SNOLAB facility located in Sudbury, Ontario, Canada. Because these detectors are passive and can be exposed for relatively long periods of time, they can provide bet… ▽ More

    Submitted 28 March, 2024; v1 submitted 9 February, 2023; originally announced February 2023.

    Comments: Discrepancy in reported TLD exposure time corrected, affecting dose rate values, not ambient dose. Corrections made, conclusions unchanged. Apologies for any inconvenience. Original article updated

    Journal ref: Sensors 2023, 23(4), 1945;

  3. arXiv:1905.05811  [pdf, other

    nucl-ex astro-ph.IM

    Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector

    Authors: R. Ajaj, G. R. Araujo, M. Batygov, B. Beltran, C. E. Bina, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, M. Cárdenas-Montes, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, K. Dering, F. A. Duncan, M. Dunford, A. Erlandson, N. Fatemighomi, G. Fiorillo, A. Flower, R. J. Ford, D. Gallacher, P. García Abia , et al. (66 additional authors not shown)

    Abstract: The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and… ▽ More

    Submitted 14 May, 2019; originally announced May 2019.

    Journal ref: Phys. Rev. D 100, 072009 (2019)

  4. arXiv:1902.04048  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex nucl-ex

    Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB

    Authors: R. Ajaj, P. -A. Amaudruz, G. R. Araujo, M. Baldwin, M. Batygov, B. Beltran, C. E. Bina, J. Bonatt, M. G. Boulay, B. Broerman, J. F. Bueno, P. M. Burghardt, A. Butcher, B. Cai, S. Cavuoti, M. Chen, Y. Chen, B. T. Cleveland, D. Cranshaw, K. Dering, J. DiGioseffo, L. Doria, F. A. Duncan, M. Dunford, A. Erlandson , et al. (77 additional authors not shown)

    Abstract: DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are obs… ▽ More

    Submitted 4 July, 2019; v1 submitted 11 February, 2019; originally announced February 2019.

    Journal ref: Phys. Rev. D 100, 022004 (2019)

  5. Design and Construction of the DEAP-3600 Dark Matter Detector

    Authors: P. -A. Amaudruz, M. Baldwin, M. Batygov, B. Beltran, C. E. Bina, D. Bishop, J. Bonatt, G. Boorman, M. G. Boulay, B. Broerman, T. Bromwich, J. F. Bueno, P. M. Burghardt, A. Butcher, B. Cai, S. Chan, M. Chen, R. Chouinard, S. Churchwell, B. T. Cleveland, D. Cranshaw, K. Dering, J. DiGioseffo, S. Dittmeier, F. A. Duncan , et al. (84 additional authors not shown)

    Abstract: The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a… ▽ More

    Submitted 10 April, 2018; v1 submitted 5 December, 2017; originally announced December 2017.

    Comments: minor corrections in version 2. 70 pages, 24 figures, to be submitted to Astroparticle Physics Journal

    Journal ref: Astropart. Phys. 108 (2019) 1-23

  6. arXiv:1707.08042  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex hep-ph

    First results from the DEAP-3600 dark matter search with argon at SNOLAB

    Authors: DEAP-3600 Collaboration, :, P. -A. Amaudruz, M. Baldwin, M. Batygov, B. Beltran, C. E. Bina, D. Bishop, J. Bonatt, G. Boorman, M. G. Boulay, B. Broerman, T. Bromwich, J. F. Bueno, P. M. Burghardt, A. Butcher, B. Cai, S. Chan, M. Chen, R. Chouinard, B. T. Cleveland, D. Cranshaw, K. Dering, J. DiGioseffo, S. Dittmeier , et al. (81 additional authors not shown)

    Abstract: This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produ… ▽ More

    Submitted 13 August, 2018; v1 submitted 25 July, 2017; originally announced July 2017.

    Comments: Accepted for publication in Physical Review Letters

    Journal ref: Phys. Rev. Lett. 121, 071801 (2018)

  7. arXiv:1408.1914  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

    Authors: M. Akashi-Ronquest, P. -A. Amaudruz, M. Batygov, B. Beltran, M. Bodmer, M. G. Boulay, B. Broerman, B. Buck, A. Butcher, B. Cai, T. Caldwell, M. Chen, Y. Chen, B. Cleveland, K. Coakley, K. Dering, F. A. Duncan, J. A. Formaggio, R. Gagnon, D. Gastler, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel, K. Graham , et al. (57 additional authors not shown)

    Abstract: Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We… ▽ More

    Submitted 12 December, 2014; v1 submitted 8 August, 2014; originally announced August 2014.

    Comments: 16 pages, 16 figures

  8. arXiv:1211.0909  [pdf, other

    astro-ph.IM nucl-ex physics.ins-det

    Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector

    Authors: P. -A. Amaudruz, M. Batygov, B. Beltran, K. Boudjemline, M. G. Boulay B. Cai T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Contreras, K. Dering, F. Duncan, R. Ford, R. Gagnon F. Giuliani, M. Gold V. V. Golovko, P. Gorel, K. Graham, D. R. Grant, R. Hakobyan, A. L. Hallin, P. Harvey, C. Hearns, C. J. Jillings, M. Kuźniak, I. Lawson, O. Li , et al. (27 additional authors not shown)

    Abstract: The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.… ▽ More

    Submitted 23 April, 2014; v1 submitted 5 November, 2012; originally announced November 2012.

    Journal ref: Astroparticle Physics 62, 178-194 (2015)

  9. Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1

    Authors: P. -A. Amaudruz, M. Batygov, B. Beltran, J. Bonatt, K. Boudjemline, M. G. Boulay, B. Broerman, J. F. Bueno, A. Butcher, B. Cai, T. Caldwell, M. Chen, R. Chouinard, B. T. Cleveland, D. Cranshaw, K. Dering, F. Duncan, N. Fatemighomi, R. Ford, R. Gagnon, P. Giampa, F. Giuliani, M. Gold, V. V. Golovko, P. Gorel , et al. (47 additional authors not shown)

    Abstract: The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV. In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be… ▽ More

    Submitted 14 September, 2016; v1 submitted 20 April, 2009; originally announced April 2009.

    Comments: Accepted for publication in Astroparticle Physics

    Journal ref: Astroparticle Physics 85 (2016) 1-23