-
Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
Authors:
PandaX-II Collaboration,
:,
Xiangyi Cui,
Abdusalam Abdukerim,
Wei Chen,
Xun Chen,
Yunhua Chen,
Binbin Dong,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Linhui Gu,
Yikun Gu,
Xuyuan Guo,
Zhifan Guo,
Ke Han,
Changda He,
Di Huang,
Shengming He,
Xingtao Huang,
Zhou Huang,
Xiangdong Ji,
Yonglin Ju,
Shaoli Li
, et al. (33 additional authors not shown)
Abstract:
We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were…
▽ More
We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were found above the expected background. With a total exposure of 5.4$\times10^4$ kg day, the most stringent upper limit on spin-independent WIMP-nucleon cross section was set for a WIMP with mass larger than 100 GeV/c$^2$, with the lowest exclusion at 8.6$\times10^{-47}$ cm$^2$ at 40 GeV/c$^2$.
△ Less
Submitted 21 September, 2017; v1 submitted 23 August, 2017;
originally announced August 2017.
-
Exploring the dark matter inelastic frontier with 79.6 days of PandaX-II data
Authors:
PandaX-II Collaboration,
:,
Xun Chen,
Abdusalam Abdukerim,
Wei Chen,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Changbo Fu,
Karl Giboni,
Franco Giuliani,
Xuyuan Guo,
Zhifan Guo,
Ke Han,
Shengming He,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Shaoli Li,
Heng Lin,
Huaxuan Liu,
Jianglai Liu,
Yugang Ma,
Yajun Mao,
Jinhua Ning
, et al. (24 additional authors not shown)
Abstract:
We report here the results of searching for inelastic scattering of dark matter (initial and final state dark matter particles differ by a small mass splitting) with nucleon with the first 79.6-day of PandaX-II data (Run 9). We set the upper limits for the spin independent WIMP-nucleon scattering cross section up to a mass splitting of 300 keV/c$^2$ at two benchmark dark matter masses of 1 and 10…
▽ More
We report here the results of searching for inelastic scattering of dark matter (initial and final state dark matter particles differ by a small mass splitting) with nucleon with the first 79.6-day of PandaX-II data (Run 9). We set the upper limits for the spin independent WIMP-nucleon scattering cross section up to a mass splitting of 300 keV/c$^2$ at two benchmark dark matter masses of 1 and 10 TeV/c$^2$.
△ Less
Submitted 3 October, 2017; v1 submitted 19 August, 2017;
originally announced August 2017.
-
Limits on Axion Couplings from the first 80-day data of PandaX-II Experiment
Authors:
Changbo Fu,
Xiaopeng Zhou,
Xun Chen,
Yunhua Chen,
Xiangyi Cui,
Deqing Fang,
Karl Giboni,
Franco Giuliani,
Ke Han,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Huaxuan Liu,
Jianglai Liu,
Yugang Ma,
Yajun Mao,
Xiangxiang Ren,
Andi Tan,
Hongwei Wang,
Jimin Wang,
Meng Wang,
Qiuhong Wang,
Siguang Wang
, et al. (12 additional authors not shown)
Abstract:
We report new searches for the solar axions and galactic axion-like dark matter particles, using the first low-background data from PandaX-II experiment at China Jinping Underground Laboratory, corresponding to a total exposure of about $2.7\times 10^4$ kg$\cdot$day. No solar axion or galactic axion-like dark matter particle candidate has been identified. The upper limit on the axion-electron coup…
▽ More
We report new searches for the solar axions and galactic axion-like dark matter particles, using the first low-background data from PandaX-II experiment at China Jinping Underground Laboratory, corresponding to a total exposure of about $2.7\times 10^4$ kg$\cdot$day. No solar axion or galactic axion-like dark matter particle candidate has been identified. The upper limit on the axion-electron coupling ($g_{Ae}$) from the solar flux is found to be about $4.35 \times 10^{-12}$ in mass range from $10^{-5}$ to 1 keV/$c^2$ with 90\% confidence level, similar to the recent LUX result. We also report a new best limit from the $^{57}$Fe de-excitation. On the other hand, the upper limit from the galactic axions is on the order of $10^{-13}$ in the mass range from 1 keV/$c^2$ to 10 keV/$c^2$ with 90\% confidence level, slightly improved compared with the LUX.
△ Less
Submitted 2 October, 2017; v1 submitted 25 July, 2017;
originally announced July 2017.
-
Spin-Dependent Weakly-Interacting-Massive-Particle--Nucleon Cross Section Limits from First Data of PandaX-II Experiment
Authors:
Changbo Fu,
Xiangyi Cui,
Xiaopeng Zhou,
Xun Chen,
Yunhua Chen,
Deqing Fang,
Karl Giboni,
Franco Giuliani,
Ke Han,
Xingtao Huang,
Xiangdong Ji,
Yonglin Ju,
Siao Lei,
Shaoli Li,
Huaxuan Liu,
Jianglai Liu,
Yugang Ma,
Yajun Mao,
Xiangxiang Ren,
Andi Tan,
Hongwei Wang,
Jiming Wang,
Meng Wang,
Qiuhong Wang,
Siguang Wang
, et al. (12 additional authors not shown)
Abstract:
New constraints are presented on the spin-dependent WIMP-nucleon interaction from the PandaX-II experiment, using a data set corresponding to a total exposure of 3.3$\times10^4$ kg-days. Assuming a standard axial-vector spin-dependent WIMP interaction with $^{129}$Xe and $^{131}$Xe nuclei, the most stringent upper limits on WIMP-neutron cross sections for WIMPs with masses above 10 GeV/c$^{2}$ are…
▽ More
New constraints are presented on the spin-dependent WIMP-nucleon interaction from the PandaX-II experiment, using a data set corresponding to a total exposure of 3.3$\times10^4$ kg-days. Assuming a standard axial-vector spin-dependent WIMP interaction with $^{129}$Xe and $^{131}$Xe nuclei, the most stringent upper limits on WIMP-neutron cross sections for WIMPs with masses above 10 GeV/c$^{2}$ are set in all dark matter direct detection experiments. The minimum upper limit of $4.1\times 10^{-41}$ cm$^2$ at 90\% confidence level is obtained for a WIMP mass of 40 GeV/c$^{2}$. This represents more than a factor of two improvement on the best available limits at this and higher masses. These improved cross-section limits provide more stringent constraints on the effective WIMP-proton and WIMP-neutron couplings.
△ Less
Submitted 14 February, 2017; v1 submitted 20 November, 2016;
originally announced November 2016.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
K. Boudjemline,
M. G. Boulay B. Cai T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Contreras,
K. Dering,
F. Duncan,
R. Ford,
R. Gagnon F. Giuliani,
M. Gold V. V. Golovko,
P. Gorel,
K. Graham,
D. R. Grant,
R. Hakobyan,
A. L. Hallin,
P. Harvey,
C. Hearns,
C. J. Jillings,
M. Kuźniak,
I. Lawson,
O. Li
, et al. (27 additional authors not shown)
Abstract:
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction.…
▽ More
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.
△ Less
Submitted 23 April, 2014; v1 submitted 5 November, 2012;
originally announced November 2012.
-
Isospin conserving Dark Matter with isospin dependent interaction, and reconciliation of contrasting results from direct Dark Matter experiments
Authors:
F. Giuliani
Abstract:
A simple model of Dark Matter (DM) which couples with the two nucleons with different coupling strengths without violating isospin conservation is explored as an example of the importance of keeping the experimental data analysis as model independent as possible. The apparent contrast between the recent CRESST event excess and current XENON100 spin-independent (SI) exclusions is shown to be remove…
▽ More
A simple model of Dark Matter (DM) which couples with the two nucleons with different coupling strengths without violating isospin conservation is explored as an example of the importance of keeping the experimental data analysis as model independent as possible. The apparent contrast between the recent CRESST event excess and current XENON100 spin-independent (SI) exclusions is shown to be removed by simply not assuming that the couplings of the DM with the two nucleons are equal.
△ Less
Submitted 20 October, 2011;
originally announced October 2011.
-
The effect of the recoil energy window on the results of direct dark matter experiments
Authors:
F. Giuliani
Abstract:
The effect of the chosen analysis energy window on the results of a dark matter experiment is exemplified by the curious intersection of the exclusion plots of the XENON10 and the CDMS experiments. After proving that the narrow energy window XENON10 chose to analyze is indeed the cause of such intersection, a method to determine the high-energy extreme of the recoil energy window an experiment s…
▽ More
The effect of the chosen analysis energy window on the results of a dark matter experiment is exemplified by the curious intersection of the exclusion plots of the XENON10 and the CDMS experiments. After proving that the narrow energy window XENON10 chose to analyze is indeed the cause of such intersection, a method to determine the high-energy extreme of the recoil energy window an experiment should use is obtained.
△ Less
Submitted 9 October, 2009;
originally announced October 2009.
-
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
Authors:
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
J. Bonatt,
K. Boudjemline,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
R. Chouinard,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
F. Duncan,
N. Fatemighomi,
R. Ford,
R. Gagnon,
P. Giampa,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel
, et al. (47 additional authors not shown)
Abstract:
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be…
▽ More
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be $<1.4\times 10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the electronic recoil contamination is $<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale.
We developed a general mathematical framework to describe PSD parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming negligible contribution from nuclear recoil backgrounds.
△ Less
Submitted 14 September, 2016; v1 submitted 20 April, 2009;
originally announced April 2009.
-
A CF3I-based SDD Prototype for Spin-independent Dark Matter Searches
Authors:
T. Morlata,
M. Felizardo,
F. Giuliani,
TA Girard,
G. Waysand,
R. F. Payne,
H. S. Miley,
A. R. Ramos,
J. G. Marques,
R. C. Martins,
D. Limagne
Abstract:
The application of Superheated Droplet Detectors (SDDs) to dark matter searches has so far been confined to the light nuclei refrigerants C2ClF5 and C4F10 (SIMPLE and PICASSO, respectively), with a principle sensitivity to spin-dependent interactions. Given the competitive results of these devices, as a result of their intrinsic insensitivity to backgrounds, we have developed a prototype trifluo…
▽ More
The application of Superheated Droplet Detectors (SDDs) to dark matter searches has so far been confined to the light nuclei refrigerants C2ClF5 and C4F10 (SIMPLE and PICASSO, respectively), with a principle sensitivity to spin-dependent interactions. Given the competitive results of these devices, as a result of their intrinsic insensitivity to backgrounds, we have developed a prototype trifluoroiodomethane (CF3I)-loaded SDD with increased sensitivity to spin-independent interactions as well. A low (0.102 kgd) exposure test operation of two high concentration, 1 liter devices is described, and the results compared with leading experiments in both spin-dependent and -independent sectors. Although competitive in both sectors when the difference in exposures is accounted for, a problem with fracturing of the detector gel must be addressed before significantly larger exposures can be envisioned.
△ Less
Submitted 26 August, 2008; v1 submitted 16 April, 2007;
originally announced April 2007.
-
Can Light-nuclei Search Experiments Constrain the Spin-independent Dark Matter Phase Space?
Authors:
F. Giuliani,
TA Girard,
T. Morlat
Abstract:
At present, restrictions on the spin-independent parameter space of WIMP dark matter searches have been limited to the results provided by relatively heavy nuclei experiments, based on the conventional wisdom that only such experiments can provide significant spin-independent limits. We examine this wisdom, showing that light nuclei experiments can in fact provide comparable limits given compara…
▽ More
At present, restrictions on the spin-independent parameter space of WIMP dark matter searches have been limited to the results provided by relatively heavy nuclei experiments, based on the conventional wisdom that only such experiments can provide significant spin-independent limits. We examine this wisdom, showing that light nuclei experiments can in fact provide comparable limits given comparable exposures, and indicating the potential of light nuclei detectors to simultaneously and competitively contribute to the search for both spin-independent and -dependent WIMP dark matter.
△ Less
Submitted 20 March, 2007;
originally announced March 2007.
-
Are direct search experiments sensitive to all spin-independent WIMP candidates?
Authors:
F. Giuliani
Abstract:
The common analysis of direct searches for spin-independent Weakly Interacting Massive Particles (WIMPs) assumes that a spin-independent WIMP couples with the same strength with both nucleons, \textit{i.e.} that the spin-independent interaction is also fully isospin-independent. Though in a fully isospin-dependent interaction scenario the spin-independent WIMP-nucleus cross section is strongly q…
▽ More
The common analysis of direct searches for spin-independent Weakly Interacting Massive Particles (WIMPs) assumes that a spin-independent WIMP couples with the same strength with both nucleons, \textit{i.e.} that the spin-independent interaction is also fully isospin-independent. Though in a fully isospin-dependent interaction scenario the spin-independent WIMP-nucleus cross section is strongly quenched, the leading experiments are still sensitive enough to set limits 1-2 orders of magnitude less stringent than those traditionally presented. In the isospin-dependent scenario the difference between the limits of CDMS-II and ZEPLIN-I is significantly reduced. Here, a model-independent framework is discussed and applied to obtain the current general model-independent limits.
△ Less
Submitted 18 April, 2005;
originally announced April 2005.
-
Model-independent Limits from Spin-dependent WIMP Dark Matter Experiments
Authors:
F. Giuliani,
TA Girard
Abstract:
Spin-dependent WIMP searches have traditionally presented results within an odd group approximation and by suppressing one of the spin-dependent interaction cross sections. We here elaborate on a model-independent analysis in which spin-dependent interactions with both protons and neutrons are simultaneously considered. Within this approach, equivalent current limits on the WIMP-nucleon interact…
▽ More
Spin-dependent WIMP searches have traditionally presented results within an odd group approximation and by suppressing one of the spin-dependent interaction cross sections. We here elaborate on a model-independent analysis in which spin-dependent interactions with both protons and neutrons are simultaneously considered. Within this approach, equivalent current limits on the WIMP-nucleon interaction at WIMP mass of 50 GeV/c$^{2}$ are either $σ_{p}\leq0.7$ pb, $σ_{n}\leq0.2$ pb or $|a_{p}|\leq0.4$, $|a_{n}|\leq0.7$ depending on the choice of cross section or coupling strength representation. These limits become less restrictive for either larger or smaller masses; they are less restrictive than those from the traditional odd group approximation regardless of WIMP mass. Combination of experimental results are seen to produce significantly more restrictive limits than those obtained from any single experiment. Experiments traditionally considered spin-independent are moreover found to severely limit the spin-dependent phase space. The extension of this analysis to the case of positive signal experiments is explored.
△ Less
Submitted 25 February, 2005;
originally announced February 2005.
-
Model-independent assessment of current direct searches for spin-dependent dark matter
Authors:
F. Giuliani
Abstract:
I evaluate the current results of spin-dependent weakly interacting massive particle (WIMP) searches within a model-independent framework, showing the most restrictive limits to date derive from the combination of xenon and sodium iodide experiments. The extension of this analysis to the case of positive signal experiments is elaborated.
I evaluate the current results of spin-dependent weakly interacting massive particle (WIMP) searches within a model-independent framework, showing the most restrictive limits to date derive from the combination of xenon and sodium iodide experiments. The extension of this analysis to the case of positive signal experiments is elaborated.
△ Less
Submitted 13 September, 2004; v1 submitted 1 April, 2004;
originally announced April 2004.
-
Exclusion limits on spin dependent WIMP-nucleon couplings from the SIMPLE experiment
Authors:
F. Giuliani,
TA Girard
Abstract:
The SIMPLE experiment is reanalyzed within the context of the WIMP model independent framework of Tovey et. al.. The results are compared with those of the UK NAIAD and NaF experiments as recently reported by the Tokyo group, together with those of the latest UK NAIAD results in 2003, and further constrain the allowed parameter space.
The SIMPLE experiment is reanalyzed within the context of the WIMP model independent framework of Tovey et. al.. The results are compared with those of the UK NAIAD and NaF experiments as recently reported by the Tokyo group, together with those of the latest UK NAIAD results in 2003, and further constrain the allowed parameter space.
△ Less
Submitted 26 November, 2003;
originally announced November 2003.