Initial radiometric calibration of the High-Resolution EUV Imager ($\textrm{HRI}_\textrm{EUV}$) of the Extreme Ultraviolet Imager (EUI) instrument onboard Solar Orbiter
Authors:
S. Gissot,
F. Auchère,
D. Berghmans,
B. Giordanengo,
A. BenMoussa,
J. Rebellato,
L. Harra,
D. Long,
P. Rochus,
U. Schühle,
R. Aznar Cuadrado,
F. Delmotte,
C. Dumesnil,
A. Gottwald,
J. -P. Halain,
K. Heerlein,
M. -L. Hellin,
A. Hermans,
L. Jacques,
E. Kraaikamp,
R. Mercier,
P. Rochus,
P. J. Smith,
L. Teriaca,
C. Verbeeck
Abstract:
The $\textrm{HRI}_\textrm{EUV}$ telescope was calibrated on ground at the Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, using the Metrology Light Source (MLS) synchrotron in April 2017 during the calibration campaign of the Extreme Ultraviolet Imager (EUI) instrument onboard the Solar Orbiter mission. We use the pre-flight end-to-end calibration and component…
▽ More
The $\textrm{HRI}_\textrm{EUV}$ telescope was calibrated on ground at the Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, using the Metrology Light Source (MLS) synchrotron in April 2017 during the calibration campaign of the Extreme Ultraviolet Imager (EUI) instrument onboard the Solar Orbiter mission. We use the pre-flight end-to-end calibration and component-level (mirror multilayer coatings, filters, detector) characterization results to establish the beginning-of-life performance of the $\textrm{HRI}_\textrm{EUV}$ telescope which shall serve as a reference for radiometric analysis and monitoring of the telescope in-flight degradation. Calibration activities at component level and end-to-end calibration of the instrument were performed at PTB/MLS synchrotron light source (Berlin, Germany) and the SOLEIL synchrotron. Each component optical property is measured and compared to its semi-empirical model. This pre-flight characterization is used to estimate the parameters of the semi-empirical models. The end-to-end response is measured and validated by comparison with calibration measurements, as well as with its main design performance requirements. The telescope spectral response semi-empirical model is validated by the pre-flight end-to-end ground calibration of the instrument. It is found that $\textrm{HRI}_\textrm{EUV}$ is a highly efficient solar EUV telescope with a peak efficiency superior to 1 e$^-$.ph$^{-1}$), low detector noise ($\approx$ 3 e- rms), low dark current at operating temperature, and a pixel saturation above 120 ke- in low-gain or combined image mode. The ground calibration also confirms a well-modeled spectral selectivity and rejection, and low stray light. The EUI instrument achieves state-of-the-art performance in terms of signal-to-noise and image spatial resolution.
△ Less
Submitted 26 July, 2023;
originally announced July 2023.
On-Orbit Degradation of Solar Instruments
Authors:
A. BenMoussa,
S. Gissot,
U. Schühle,
G. Del Zanna,
F. Auchère,
S. Mekaoui,
A. R. Jones,
D. Walton,
C. J. Eyles,
G. Thuillier,
D. Seaton,
I. E. Dammasch,
G. Cessateur,
M. Meftah,
V. Andretta,
D. Berghmans,
D. Bewsher,
D. Bolsée,
L. Bradley,
D. S. Brown,
P. C. Chamberlin,
S. Dewitte,
L. V. Didkovsky,
M. Dominique,
F. G. Eparvier
, et al. (16 additional authors not shown)
Abstract:
We present the lessons learned about the degradation observed in several space solar missions, based on contributions at the Workshop about On-Orbit Degradation of Solar and Space Weather Instruments that took place at the Solar Terrestrial Centre of Excellence (Royal Observatory of Belgium) in Brussels on 3 May 2012. The aim of this workshop was to open discussions related to the degradation obse…
▽ More
We present the lessons learned about the degradation observed in several space solar missions, based on contributions at the Workshop about On-Orbit Degradation of Solar and Space Weather Instruments that took place at the Solar Terrestrial Centre of Excellence (Royal Observatory of Belgium) in Brussels on 3 May 2012. The aim of this workshop was to open discussions related to the degradation observed in Sun-observing instruments exposed to the effects of the space environment. This article summarizes the various lessons learned and offers recommendations to reduce or correct expected degradation with the goal of increasing the useful lifespan of future and ongoing space missions.
△ Less
Submitted 19 April, 2013;
originally announced April 2013.