-
Towards an overall astrometric error budget with MICADO-MCAO
Authors:
Gabriele Rodeghiero,
Jörg Uwe Pott,
Davide Massari,
Maximilian Fabricius,
Vincent Garrel,
Hannes Riechert,
Richard Davies,
Carmelo Arcidiacono,
Mauro Patti,
Fausto Cortecchia,
Giuliana Fiorentino,
Matteo Lombini
Abstract:
MICADO is the Multi-AO Imaging Camera for Deep Observations, and it will be one of the first light instruments of the Extremely Large Telescope (ELT). Doing high precision multi-object differential astrometry behind ELT is particularly effective given the increased flux and small diffraction limit. Thanks to its robust design with fixed mirrors and a cryogenic environment, MICADO aims to provide 5…
▽ More
MICADO is the Multi-AO Imaging Camera for Deep Observations, and it will be one of the first light instruments of the Extremely Large Telescope (ELT). Doing high precision multi-object differential astrometry behind ELT is particularly effective given the increased flux and small diffraction limit. Thanks to its robust design with fixed mirrors and a cryogenic environment, MICADO aims to provide 50 $μ$as absolute differential astrometry (measure star-to-star distances in absolute $μ$as units) over a 53" FoV in the range 1.2-2.5 $μ$m. Tackling high precision astrometry over large FoV requires Multi Conjugate Adaptive Optics (MCAO) and an accurate distortion calibration. The MICADO control scheme relies on the separate calibration of the ELT, MAORY and MICADO systematics and distortions, to ensure the best disentanglement and correction of all the contributions. From a system perspective, we are developing an astrometric error budget supported by optical simulations to assess the impact of the main astrometric errors induced by the telescope and its optical tolerances, the MCAO distortions and the opto-mechanical errors between internal optics of ELT, MAORY and MICADO. The development of an overall astrometric error budget will pave the road to an efficient calibration strategy complementing the design of the MICADO calibration unit. At the focus of this work are a number of opto-mechanical error terms which have particular relevance for MICADO astrometry applications, and interface to the MCAO design.
△ Less
Submitted 3 February, 2019;
originally announced February 2019.
-
The MICADO first light imager for the ELT: overview, operation, simulation
Authors:
Richard Davies,
João Alves,
Yann Clénet,
Florian Lang-Bardl,
Harald Nicklas,
Jörg-Uwe Pott,
Roberto Ragazzoni,
Eline Tolstoy,
Paola Amico,
Heiko Anwand-Heerwart,
Santiago Barboza,
Lothar Barl,
Pierre Baudoz,
Ralf Bender,
Naidu Bezawada,
Peter Bizenberger,
Wilfried Boland,
Piercarlo Bonifacio,
Bruno Borgo,
Tristan Buey,
Frédéric Chapron,
Fanny Chemla,
Mathieu Cohen,
Oliver Czoske,
Vincent Deo
, et al. (76 additional authors not shown)
Abstract:
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and m…
▽ More
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and making use of the data simulation tool, an outline is presented of what we can expect the instrument to achieve.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
Individual, Model-Independent Masses of the Closest Known Brown Dwarf Binary to the Sun
Authors:
E. Victor Garcia,
S. Mark Ammons,
Maissa Salama,
Ian Crossfield,
Eduardo Bendek,
Jeffrey Chilcote,
Vincent Garrel,
James R. Graham,
Paul Kalas,
Quinn Konopacky,
Jessica R. Lu,
Bruce Macintosh,
Eduardo Marin,
Christian Marois,
Eric Nielsen,
Benoît Neichel,
Don Pham,
Robert J. De Rosa,
Dominic M. Ryan,
Maxwell Service,
Gaetano Sivo
Abstract:
At a distance of 2~pc, our nearest brown dwarf neighbor, Luhman 16 AB, has been extensively studied since its discovery 3 years ago, yet its most fundamental parameter -- the masses of the individual dwarfs -- has not been constrained with precision. In this work we present the full astrometric orbit and barycentric motion of Luhman 16 AB and the first precision measurements of the individual comp…
▽ More
At a distance of 2~pc, our nearest brown dwarf neighbor, Luhman 16 AB, has been extensively studied since its discovery 3 years ago, yet its most fundamental parameter -- the masses of the individual dwarfs -- has not been constrained with precision. In this work we present the full astrometric orbit and barycentric motion of Luhman 16 AB and the first precision measurements of the individual component masses. We draw upon archival observations spanning 31 years from the European Southern Observatory (ESO) Schmidt Telescope, the Deep Near-Infrared Survey of the Southern Sky (DENIS), public FORS2 data on the Very Large Telescope (VLT), and new astrometry from the Gemini South Multiconjugate Adaptive Optics System (GeMS). Finally, we include three radial velocity measurements of the two components from VLT/CRIRES, spanning one year. With this new data sampling a full period of the orbit, we use a Markov Chain Monte Carlo algorithm to fit a 16-parameter model incorporating mutual orbit and barycentric motion parameters and constrain the individual masses to be~$27.9^{+1.1}_{-1.0}$~$M_{J}$ for the T dwarf and~$34.2^{+1.3}_{-1.1}$~$M_{J}$ for the L dwarf. Our measurements of Luhman 16 AB's mass ratio and barycentric motion parameters are consistent with previous estimates in the literature utilizing recent astrometry only. The GeMS-derived measurements of the Luhman 16 AB separation in 2014-2015 agree closely with Hubble Space Telescope (HST) measurements made during the same epoch Bedin et al. 2017, and the derived mutual orbit agrees with those measurements to within the HST uncertainties of $0.3 - 0.4$ milliarcseconds.
△ Less
Submitted 12 August, 2017; v1 submitted 9 August, 2017;
originally announced August 2017.
-
Multi-conjugated adaptive optics imaging of distant galaxies -- A comparison of Gemini/GSAOI and VLT/HAWK-I data
Authors:
Mischa Schirmer,
Vincent Garrel,
Gaetano Sivo,
Eduardo Marin,
Eleazar R. Carrasco
Abstract:
Multi-conjugated adaptive optics (MCAO) yield nearly diffraction-limited images at 2$μ$m wavelengths. Currently, GeMS/GSAOI at Gemini South is the only MCAO facility instrument at an 8m telescope. Using real data and for the first time, we investigate the gain in depth and S/N when MCAO is employed for $K_{\rm s}$-band observations of distant galaxies. Our analysis is based on the Frontier Fields…
▽ More
Multi-conjugated adaptive optics (MCAO) yield nearly diffraction-limited images at 2$μ$m wavelengths. Currently, GeMS/GSAOI at Gemini South is the only MCAO facility instrument at an 8m telescope. Using real data and for the first time, we investigate the gain in depth and S/N when MCAO is employed for $K_{\rm s}$-band observations of distant galaxies. Our analysis is based on the Frontier Fields cluster MACS J0416.1-2403, observed with GeMS/GSAOI (near diffraction-limited) and compared against VLT/HAWK-I (natural seeing) data. Using galaxy number counts, we show that the substantially increased thermal background and lower optical throughput of the MCAO unit are fully compensated for by the wavefront correction, because the galaxy images can be measured in smaller apertures with less sky noise. We also performed a direct comparison of the signal-to-noise ratios (S/N) of sources detected in both data sets. For objects with intrinsic angular sizes corresponding to half the HAWK-I image seeing, the gain in S/N is 40 per cent. Even smaller objects experience a boost in S/N by a up to a factor of 2.5 despite our suboptimal natural guide star configuration. The depth of the near diffraction limited images is more difficult to quantify than that of seeing limited images, due to a strong dependence on the intrinsic source profiles. Our results emphasize the importance of cooled MCAO systems for $K_{\rm s}$-band observations with future, extremely large telescopes.
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
First performance of the gems + gmos system. Part1. Imaging
Authors:
Pascale Hibon,
Vincent Garrel,
Benoit Neichel,
Benjamin Prout,
Francois Rigaut,
Alice Koning,
Eleazar R. Carrasco,
German Gimeno,
Peter Pessev
Abstract:
During the commissioning of the Gemini MCAO System (GeMS), we had the opportunity to obtain data with the Gemini Multi-Object Spectrograph (GMOS), the most utilised instrument at Gemini South Observatory, in March and May 2012. Several globular clusters were observed in imaging mode that allowed us to study the performance of this new and untested combination. GMOS is a visible instrument, hence p…
▽ More
During the commissioning of the Gemini MCAO System (GeMS), we had the opportunity to obtain data with the Gemini Multi-Object Spectrograph (GMOS), the most utilised instrument at Gemini South Observatory, in March and May 2012. Several globular clusters were observed in imaging mode that allowed us to study the performance of this new and untested combination. GMOS is a visible instrument, hence pushing MCAO toward the visible.We report here on the results with the GMOS instruments, derive photometric performance in term of Full Width Half Maximum (FWHM) and throughput. In most of the cases, we obtained an improvement factor of at least 2 against the natural seeing. This result also depends on the Natural Guide Star constellation selected for the observations and we then study the impact of the guide star selection on the FWHM performance.We also derive a first astrometric analysis showing that the GeMS+GMOS system provide an absolute astrometric precision better than 8mas and a relative astrometric precision lower than 50 mas.
△ Less
Submitted 12 April, 2016;
originally announced April 2016.
-
The Subaru Coronagraphic Extreme Adaptive Optics system: enabling high-contrast imaging on solar-system scales
Authors:
N. Jovanovic,
F. Martinache,
O. Guyon,
C. Clergeon,
G. Singh,
T. Kudo,
V. Garrel,
K. Newman,
D. Doughty,
J. Lozi,
J. Males,
Y. Minowa,
Y. Hayano,
N. Takato,
J. Morino,
J. Kuhn,
E. Serabyn,
B. Norris,
P. Tuthill,
G. Schworer,
P. Stewart,
L. Close,
E. Huby,
G. Perrin,
S. Lacour
, et al. (13 additional authors not shown)
Abstract:
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is a multipurpose high-contrast imaging platform designed for the discovery and detailed characterization of exoplanetary systems and serves as a testbed for high-contrast imaging technologies for ELTs. It is a multi-band instrument which makes use of light from 600 to 2500nm allowing for coronagraphic direct exoplanet imaging of…
▽ More
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is a multipurpose high-contrast imaging platform designed for the discovery and detailed characterization of exoplanetary systems and serves as a testbed for high-contrast imaging technologies for ELTs. It is a multi-band instrument which makes use of light from 600 to 2500nm allowing for coronagraphic direct exoplanet imaging of the inner 3 lambda/D from the stellar host. Wavefront sensing and control are key to the operation of SCExAO. A partial correction of low-order modes is provided by Subaru's facility adaptive optics system with the final correction, including high-order modes, implemented downstream by a combination of a visible pyramid wavefront sensor and a 2000-element deformable mirror. The well corrected NIR (y-K bands) wavefronts can then be injected into any of the available coronagraphs, including but not limited to the phase induced amplitude apodization and the vector vortex coronagraphs, both of which offer an inner working angle as low as 1 lambda/D. Non-common path, low-order aberrations are sensed with a coronagraphic low-order wavefront sensor in the infrared (IR). Low noise, high frame rate, NIR detectors allow for active speckle nulling and coherent differential imaging, while the HAWAII 2RG detector in the HiCIAO imager and/or the CHARIS integral field spectrograph (from mid 2016) can take deeper exposures and/or perform angular, spectral and polarimetric differential imaging. Science in the visible is provided by two interferometric modules: VAMPIRES and FIRST, which enable sub-diffraction limited imaging in the visible region with polarimetric and spectroscopic capabilities respectively. We describe the instrument in detail and present preliminary results both on-sky and in the laboratory.
△ Less
Submitted 30 June, 2015;
originally announced July 2015.
-
Gemini Frontier Fields: Wide-field Adaptive Optics $K_s$-band Imaging of the Galaxy Clusters MACS J0416.1-2403 and Abell 2744
Authors:
Mischa Schirmer,
Rodrigo Carrasco,
Peter Pessev,
Vincent Garrel,
Claudia Winge,
Benoit Neichel,
Fabrice Vidal
Abstract:
We have observed two of the six Frontier Fields galaxy clusters, MACS J0416.1-2403 and Abell 2744, using the Gemini Multi-Conjugate Adaptive Optics System (GeMS) and the Gemini South Adaptive Optics Imager (GSAOI). With 0.08"-0.10" FWHM our data are nearly diffraction-limited over a 100"x100" wide area. GeMS/GSAOI complements the Hubble Space Telescope (HST) redwards of 1.6microns with twice the a…
▽ More
We have observed two of the six Frontier Fields galaxy clusters, MACS J0416.1-2403 and Abell 2744, using the Gemini Multi-Conjugate Adaptive Optics System (GeMS) and the Gemini South Adaptive Optics Imager (GSAOI). With 0.08"-0.10" FWHM our data are nearly diffraction-limited over a 100"x100" wide area. GeMS/GSAOI complements the Hubble Space Telescope (HST) redwards of 1.6microns with twice the angular resolution. We reach a 5 sigma depth of Ks = 25.6 mag (AB) for compact sources. In this paper we describe the observations, the data processing and the initial public data release. We provide fully calibrated, co-added images matching the native GSAOI pixel scale as well as the larger plate scales of the HST release, adding to the legacy value of the Frontier Fields. Our work demonstrates that even for fields at high galactic latitude, where natural guide stars are rare, current multi-conjugated adaptive optics technology at 8m-telescopes has opened a new window on the distant Universe. Observations of a third Frontier Field, Abell 370, are planned.
△ Less
Submitted 6 March, 2015; v1 submitted 5 September, 2014;
originally announced September 2014.
-
Gemini multi-conjugate adaptive optics system review II: Commissioning, operation and overall performance
Authors:
Benoit Neichel,
François Rigaut,
Fabrice Vidal,
Marcos A. van Dam,
Vincent Garrel,
Eleazar Rodrigo Carrasco,
Peter Pessev,
Claudia Winge,
Maxime Boccas,
Céline d'Orgeville,
Gustavo Arriagada,
Andrew Serio,
Vincent Fesquet,
William N. Rambold,
Javier Lührs,
Cristian Moreno,
Gaston Gausachs,
Ramon L. Galvez,
Vanessa Montes,
Tomislav B. Vucina,
Eduardo Marin,
Cristian Urrutia,
Ariel Lopez,
Sarah J. Diggs,
Claudio Marchant
, et al. (8 additional authors not shown)
Abstract:
The Gemini Multi-conjugate Adaptive Optics System - GeMS, a facility instrument mounted on the Gemini South telescope, delivers a uniform, near diffraction limited images at near infrared wavelengths (0.95 microns- 2.5 microns) over a field of view of 120 arc seconds. GeMS is the first sodium layer based multi laser guide star adaptive optics system used in astronomy. It uses five laser guide star…
▽ More
The Gemini Multi-conjugate Adaptive Optics System - GeMS, a facility instrument mounted on the Gemini South telescope, delivers a uniform, near diffraction limited images at near infrared wavelengths (0.95 microns- 2.5 microns) over a field of view of 120 arc seconds. GeMS is the first sodium layer based multi laser guide star adaptive optics system used in astronomy. It uses five laser guide stars distributed on a 60 arc seconds square constellation to measure for atmospheric distortions and two deformable mirrors to compensate for it. In this paper, the second devoted to describe the GeMS project, we present the commissioning, overall performance and operational scheme of GeMS. Performance of each sub-system is derived from the commissioning results. The typical image quality, expressed in full with half maximum, Strehl ratios and variations over the field delivered by the system are then described. A discussion of the main contributor to performance limitation is carried-out. Finally, overheads and future system upgrades are described.
△ Less
Submitted 27 February, 2014;
originally announced February 2014.
-
Gems first science results
Authors:
Benoit Neichel,
Fabrice Vidal,
Francois Rigaut,
Eleazar Rodrigo Carrasco,
Gustavo Arriagada,
Andrew Serio,
Peter Pessev,
Claudia Winge,
Marcos van Dam,
Vincent Garrel,
Constanza Araujo,
Maxime Boccas,
Vincent Fesquet,
Ramon Galvez,
Gaston Gausachs,
Javier Luhrs,
Vanessa Montes,
Cristian Moreno,
William Rambold,
Chadwick Trujillo,
Cristian Urrutia,
Tomislav Vucina
Abstract:
After 101 nights of commissioning, the Gemini MCAO system (GeMS) started science operations in December 2012. After a brief reminder on GeMS specificities, we describe the overall GeMS performance, and we focus then on the first science results obtained with GeMS, illustrating the unique capabilities of this new Gemini instrument.
After 101 nights of commissioning, the Gemini MCAO system (GeMS) started science operations in December 2012. After a brief reminder on GeMS specificities, we describe the overall GeMS performance, and we focus then on the first science results obtained with GeMS, illustrating the unique capabilities of this new Gemini instrument.
△ Less
Submitted 9 January, 2014;
originally announced January 2014.
-
SCExAO as a precursor to an ELT exoplanet direct imaging instrument
Authors:
Nemanja Jovanovic,
Olivier Guyon,
Frantz martinache,
Christophe Clergeon,
Garima Singh,
Sebastien Vievard,
Tomoyuki Kudo,
Vincent Garrel,
Barnaby Norris,
Peter Tuthill,
Paul Stewart,
Elsa huby,
Guy Perrin,
Sylvestre Lacour
Abstract:
The Subaru Coronagraphic Extreme AO (SCExAO) instrument consists of a high performance Phase Induced Amplitude Apodisation (PIAA) coronagraph combined with an extreme Adaptive Optics (AO) system operating in the near-infrared (H band). The extreme AO system driven by the 2000 element deformable mirror will allow for Strehl ratios >90% to be achieved in the H-band when it goes closed loop. This mak…
▽ More
The Subaru Coronagraphic Extreme AO (SCExAO) instrument consists of a high performance Phase Induced Amplitude Apodisation (PIAA) coronagraph combined with an extreme Adaptive Optics (AO) system operating in the near-infrared (H band). The extreme AO system driven by the 2000 element deformable mirror will allow for Strehl ratios >90% to be achieved in the H-band when it goes closed loop. This makes the SCExAO instrument a powerful platform for high contrast imaging down to angular separations of the order of 1lambda/D and an ideal testbed for exploring coronagraphic techniques for ELTs. In this paper we report on the recent progress in regards to the development of the instrument, which includes the addition of a visible bench that makes use of the light at shorter wavelengths not currently utilized by SCExAO and closing the loop on the tip/tilt wavefront sensor. We will also discuss several exciting guest instruments which will expand the capabilities of SCExAO over the next few years; namely CHARIS which is a integral field spectrograph as well as VAMPIRES, a visible aperture masking experiment based on polarimetric analysis of circumstellar disks. In addition we will elucidate the unique role extreme AO systems will play in enabling high precision radial velocity spectroscopy for the detection of small companions.
△ Less
Submitted 14 October, 2013; v1 submitted 1 October, 2013;
originally announced October 2013.
-
Coronagraphic Low Order Wave Front Sensor : post-processing sensitivity enhancer for high performance coronagraphs
Authors:
Frédéric P. A. Vogt,
Frantz Martinache,
Olivier Guyon,
Takashi Yoshikawa,
Kaito Yokochi,
Vincent Garrel,
Taro Matsuo
Abstract:
Detection and characterization of exoplanets by direct imaging requires a coronagraph designed to deliver high contrast at small angular separation. To achieve this, an accurate control of low order aberrations, such as pointing and focus errors, is essential to optimize coronagraphic rejection and avoid the possible confusion between exoplanet light and coronagraphic leaks in the science image. S…
▽ More
Detection and characterization of exoplanets by direct imaging requires a coronagraph designed to deliver high contrast at small angular separation. To achieve this, an accurate control of low order aberrations, such as pointing and focus errors, is essential to optimize coronagraphic rejection and avoid the possible confusion between exoplanet light and coronagraphic leaks in the science image. Simulations and laboratory prototyping have shown that a Coronagraphic Low Order Wave-Front Sensor (CLOWFS), using a single defocused image of a reflective focal plane ring, can be used to control tip-tilt to an accuracy of 10^{-3} lambda/D. This paper demonstrates that the data acquired by CLOWFS can also be used in post-processing to calibrate residual coronagraphic leaks from the science image. Using both the CLOWFS camera and the science camera in the system, we quantify the accuracy of the method and its ability to successfully remove light due to low order errors from the science image. We also report the implementation and performance of the CLOWFS on the Subaru Coronagraphic Extreme AO (SCExAO) system and its expected on-sky performance. In the laboratory, with a level of disturbance similar to what is encountered in a post Adaptive Optics beam, CLOWFS post-processing has achieved speckle calibration to 1/300 of the raw speckle level. This is about 40 times better than could be done with an idealized PSF subtraction that does not rely on CLOWFS.
△ Less
Submitted 13 December, 2011;
originally announced December 2011.
-
Aperture Masking Interferometry for Subaru
Authors:
Frantz Martinache,
Olivier Guyon,
Vincent Garrel
Abstract:
Aperture Masking Interferometry used in combination with Adaptive Optics, is a powerful technique that permits the detection of faint companions at small angular separations. The precision calibration of the data achieved with this observing mode indeed leads to reliable results up to and beyond the formal diffraction limit, explaining why it has, in just a few years, been ported on most major t…
▽ More
Aperture Masking Interferometry used in combination with Adaptive Optics, is a powerful technique that permits the detection of faint companions at small angular separations. The precision calibration of the data achieved with this observing mode indeed leads to reliable results up to and beyond the formal diffraction limit, explaining why it has, in just a few years, been ported on most major telescopes. In this poster, we present its possible implementation on Subaru. We also discuss how the opportunity offered by the planned Extreme-AO upgrade to HiCIAO will push further the performance of this already successful technique, offering Subaru a unique access to a very exciting region of the "contrast-ratio - angular separation" parameter space.
△ Less
Submitted 1 May, 2009;
originally announced May 2009.
-
The Subaru Coronagraphic Extreme AO project
Authors:
Frantz Martinache,
Olivier Guyon,
Julien Lozi,
Vincent Garrel,
Celia Blain,
Gaetano Sivo
Abstract:
High contrast coronagraphic imaging is a challenging task for telescopes with central obscurations and thick spider vanes, such as the Subaru Telescope. Our group is currently assembling an extreme AO bench designed as an upgrade for the newly commissionned coronagraphic imager instrument HiCIAO, that addresses these difficulties. The so-called SCExAO system combines a high performance PIAA coro…
▽ More
High contrast coronagraphic imaging is a challenging task for telescopes with central obscurations and thick spider vanes, such as the Subaru Telescope. Our group is currently assembling an extreme AO bench designed as an upgrade for the newly commissionned coronagraphic imager instrument HiCIAO, that addresses these difficulties. The so-called SCExAO system combines a high performance PIAA coronagraph to a MEMS-based wavefront control system that will be used in complement of the Subaru AO188 system. We present and demonstrate good performance of two key optical components that suppress the spider vanes, the central obscuration and apodize the beam for high contrast coronagraphy, while preserving the throughput and the angular resolution.
△ Less
Submitted 1 May, 2009;
originally announced May 2009.