-
Calibration of the Herschel SPIRE Fourier Transform Spectrometer
Authors:
B. M. Swinyard,
E. T. Polehampton,
R. Hopwood,
I. Valtchanov,
N. Lu,
T. Fulton,
D. Benielli,
P. Imhof,
N. Marchili,
J. -P. Baluteau,
G. J. Bendo,
M. Ferlet,
M. J. Griffin,
T. L. Lim,
G. Makiwa,
D. A. Naylor,
G. S. Orton,
A. Papageorgiou,
C. P. Pearson,
B. Schulz,
S. D. Sidher,
L. D. Spencer,
M. H. D. van der Wiel,
R. Wu
Abstract:
The Herschel SPIRE instrument consists of an imaging photometric camera and an imaging Fourier Transform Spectrometer (FTS), both operating over a frequency range of 450-1550 GHz. In this paper, we briefly review the FTS design, operation, and data reduction, and describe in detail the approach taken to relative calibration (removal of instrument signatures) and absolute calibration against standa…
▽ More
The Herschel SPIRE instrument consists of an imaging photometric camera and an imaging Fourier Transform Spectrometer (FTS), both operating over a frequency range of 450-1550 GHz. In this paper, we briefly review the FTS design, operation, and data reduction, and describe in detail the approach taken to relative calibration (removal of instrument signatures) and absolute calibration against standard astronomical sources. The calibration scheme assumes a spatially extended source and uses the Herschel telescope as primary calibrator. Conversion from extended to point-source calibration is carried out using observations of the planet Uranus. The model of the telescope emission is shown to be accurate to within 6% and repeatable to better than 0.06% and, by comparison with models of Mars and Neptune, the Uranus model is shown to be accurate to within 3%. Multiple observations of a number of point-like sources show that the repeatability of the calibration is better than 1%, if the effects of the satellite absolute pointing error (APE) are corrected. The satellite APE leads to a decrement in the derived flux, which can be up to ~10% (1 sigma) at the high-frequency end of the SPIRE range in the first part of the mission, and ~4% after Herschel operational day 1011. The lower frequency range of the SPIRE band is unaffected by this pointing error due to the larger beam size. Overall, for well-pointed, point-like sources, the absolute flux calibration is better than 6%, and for extended sources where mapping is required it is better than 7%.
△ Less
Submitted 5 March, 2014;
originally announced March 2014.
-
Observing Extended Sources with the \Herschel SPIRE Fourier Transform Spectrometer
Authors:
Ronin Wu,
Edward T. Polehampton,
Mireya Etxaluze,
Gibion Makiwa,
David A. Naylor,
Carl Salji,
Bruce M. Swinyard,
Marc Ferlet,
Matthijs H. D. van der Wiel,
Anthony J. Smith,
Trevor Fulton,
Matt J. Griffin,
Jean-Paul Baluteau,
Dominique Benielli,
Jason Glenn,
Rosalind Hopwood,
Peter Imhof,
Tanya Lim,
Nanyao Lu,
Pasquale Panuzzo,
Chris Pearson,
Sunil Sidher,
Ivan Valtchanov
Abstract:
The Spectral and Photometric Imaging Receiver (SPIRE) on the European Space Agency's Herschel Space Observatory utilizes a pioneering design for its imaging spectrometer in the form of a Fourier Transform Spectrometer (FTS). The standard FTS data reduction and calibration schemes are aimed at objects with either a spatial extent much larger than the beam size or a source that can be approximated a…
▽ More
The Spectral and Photometric Imaging Receiver (SPIRE) on the European Space Agency's Herschel Space Observatory utilizes a pioneering design for its imaging spectrometer in the form of a Fourier Transform Spectrometer (FTS). The standard FTS data reduction and calibration schemes are aimed at objects with either a spatial extent much larger than the beam size or a source that can be approximated as a point source within the beam. However, when sources are of intermediate spatial extent, neither of these calibrations schemes is appropriate and both the spatial response of the instrument and the source's light profile must be taken into account and the coupling between them explicitly derived. To that end, we derive the necessary corrections using an observed spectrum of a fully extended source with the beam profile and the source's light profile taken into account. We apply the derived correction to several observations of planets and compare the corrected spectra with their spectral models to study the beam coupling efficiency of the instrument in the case of partially extended sources. We find that we can apply these correction factors for sources with angular sizes up to θ_{D} ~ 17". We demonstrate how the angular size of an extended source can be estimated using the difference between the sub-spectra observed at the overlap bandwidth of the two frequency channels in the spectrometer, at 959<ν<989 GHz. Using this technique on an observation of Saturn, we estimate a size of 17.2", which is 3% larger than its true size on the day of observation. Finally, we show the results of the correction applied on observations of a nearby galaxy, M82, and the compact core of a Galactic molecular cloud, Sgr B2.
△ Less
Submitted 24 June, 2013;
originally announced June 2013.
-
Flux Calibration of Broadband Far Infrared and Submillimetre Photometric Instruments: Theory and Application to Herschel-SPIRE
Authors:
M. J. Griffin,
C. E. North,
B. Schulz,
A. Amaral-Rogers,
G. Bendo,
J. Bock,
L. Conversi,
A. Conley,
C. D. Dowell,
M. Ferlet,
J. Glenn,
T. Lim,
C. Pearson,
M. Pohlen,
B. Sibthorpe,
L. Spencer,
B. Swinyard,
I. Valtchanov
Abstract:
Photometric instruments operating at far infrared to millimetre wavelengths often have broad spectral passbands (central wavelength/bandwidth ~ 3 or less), especially those operating in space. A broad passband can result in significant variation of the beam profile and aperture efficiency across the passband, effects which thus far have not generally been taken into account in the flux calibration…
▽ More
Photometric instruments operating at far infrared to millimetre wavelengths often have broad spectral passbands (central wavelength/bandwidth ~ 3 or less), especially those operating in space. A broad passband can result in significant variation of the beam profile and aperture efficiency across the passband, effects which thus far have not generally been taken into account in the flux calibration of such instruments. With absolute calibration uncertainties associated with the brightness of primary calibration standards now in the region of 5% or less, variation of the beam properties across the passband can be a significant contributor to the overall calibration accuracy for extended emission. We present a calibration framework which takes such variations into account for both antenna-coupled and absorber-coupled focal plane architectures. The scheme covers point source and extended source cases, and also the intermediate case of a semi-extended source profile. We apply the new method to the Herschel-SPIRE space-borne photometer.
△ Less
Submitted 11 August, 2014; v1 submitted 7 June, 2013;
originally announced June 2013.
-
The Herschel-SPIRE instrument and its in-flight performance
Authors:
M. J. Griffin,
A. Abergel,
A. Abreu,
P. A. R. Ade,
P. André,
J. -L. Augueres,
T. Babbedge,
Y. Bae,
T. Baillie,
J. -P. Baluteau,
M. J. Barlow,
G. Bendo,
D. Benielli,
J. J. Bock,
P. Bonhomme,
D. Brisbin,
C. Brockley-Blatt,
M. Caldwell,
C. Cara,
N. Castro-Rodriguez,
R. Cerulli,
P. Chanial,
S. Chen,
E. Clark,
D. L. Clements
, et al. (154 additional authors not shown)
Abstract:
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-c…
▽ More
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-mapping, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.
-
In-flight calibration of the Herschel-SPIRE instrument
Authors:
B. M. Swinyard,
P. Ade,
J-P. Baluteau,
H. Aussel,
M. J. Barlow,
G. J. Bendo,
D. Benielli,
J. Bock,
D. Brisbin,
A. Conley,
L. Conversi,
A. Dowell,
D. Dowell,
M. Ferlet,
T. Fulton,
J. Glenn,
A. Glauser,
D. Griffin,
M. Griffin,
S. Guest,
P. Imhof,
K. Isaak,
S. Jones,
K. King,
S. Leeks
, et al. (33 additional authors not shown)
Abstract:
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space Observatory's submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 μm, and an imaging Fourier transform spectrometer (FTS) covering 194-671 μm (447-1550 GHz). In this paper we describe the initial approach taken to the absolute calibration of the SPIRE instrument…
▽ More
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space Observatory's submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 μm, and an imaging Fourier transform spectrometer (FTS) covering 194-671 μm (447-1550 GHz). In this paper we describe the initial approach taken to the absolute calibration of the SPIRE instrument using a combination of the emission from the Herschel telescope itself and the modelled continuum emission from solar system objects and other astronomical targets. We present the photometric, spectroscopic and spatial accuracy that is obtainable in data processed through the "standard" pipelines. The overall photometric accuracy at this stage of the mission is estimated as 15% for the photometer and between 15 and 50% for the spectrometer. However, there remain issues with the photometric accuracy of the spectra of low flux sources in the longest wavelength part of the SPIRE spectrometer band. The spectrometer wavelength accuracy is determined to be better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is found to be 2 arcsec when the latest calibration data are used. The photometric calibration of the SPIRE instrument is currently determined by a combination of uncertainties in the model spectra of the astronomical standards and the data processing methods employed for map and spectrum calibration. Improvements in processing techniques and a better understanding of the instrument performance will lead to the final calibration accuracy of SPIRE being determined only by uncertainties in the models of astronomical standards.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.
-
Using SPICA Space Telescope to characterize Exoplanets
Authors:
J. R. Goicoechea,
B. Swinyard,
G. Tinetti,
T. Nakagawa,
K. Enya,
M. Tamura,
M. Ferlet,
K. G. Isaak,
M. Wyatt,
A. D. Aylward,
M. Barlow,
J. P. Beaulieu,
A. Boccaletti,
J. Cernicharo,
J. Cho,
R. Claudi,
H. Jones,
H. Lammer,
A. Leger,
J. Martín-Pintado,
S. Miller,
F. Najarro,
D. Pinfield,
J. Schneider,
F. Selsis
, et al. (4 additional authors not shown)
Abstract:
We present the 3.5m SPICA space telescope, a proposed Japanese-led JAXA-ESA mission scheduled for launch around 2017. The actively cooled (<5 K), single aperture telescope and monolithic mirror will operate from ~3.5 to ~210 um and will provide superb sensitivity in the mid- and far-IR spectral domain (better than JWST at lambda > 18 um). SPICA is one of the few space missions selected to go to…
▽ More
We present the 3.5m SPICA space telescope, a proposed Japanese-led JAXA-ESA mission scheduled for launch around 2017. The actively cooled (<5 K), single aperture telescope and monolithic mirror will operate from ~3.5 to ~210 um and will provide superb sensitivity in the mid- and far-IR spectral domain (better than JWST at lambda > 18 um). SPICA is one of the few space missions selected to go to the next stage of ESA's Cosmic Vision 2015-2025 selection process. In this White Paper we present the main specifications of the three instruments currently baselined for SPICA: a mid-infrared (MIR) coronagraph (~3.5 to ~27 um) with photometric and spectral capabilities (R~200), a MIR wide-field camera and high resolution spectrometer (R~30,000), and a far-infrared (FIR ~30 to ~210 um) imaging spectrometer - SAFARI - led by a European consortium. We discuss their capabilities in the context of MIR direct observations of exo-planets (EPs) and multiband photometry/high resolution spectroscopy observations of transiting exo-planets. We conclude that SPICA will be able to characterize the atmospheres of transiting exo-planets down to the super-Earth size previously detected by ground- or space-based observatories. It will also directly detect and characterize Jupiter/Neptune-size planets orbiting at larger separation from their parent star (>5-10 AU), by performing quantitative atmospheric spectroscopy and studying proto-planetary and debris disks. In addition, SPICA will be a scientific and technological precursor for future, more ambitious, IR space missions for exo-planet direct detection as it will, for example, quantify the prevalence exo-zodiacal clouds in planetary systems and test coronographic techniques, cryogenic systems and lightweight, high quality telescopes. (abridged)
△ Less
Submitted 15 September, 2008; v1 submitted 1 September, 2008;
originally announced September 2008.