-
Automation of MKID Simulations for Array Building with AEM (Automated Electromagnetic MKID Simulations)
Authors:
Cáthal McAleer,
Oisin Creaner,
Colm Bracken,
Gerhard Ulbricht,
Mario De Lucia,
Jack Piercy
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are photon detectors comprised of superconducting LC resonators with unique resonant frequencies corresponding to their geometrical structure. As each pixel has its own geometry, electromagnetic simulations by hand of every pixel in a kilo-pixel array are impractical. Simulating fewer pixels and interpolating in between risks reduced pixel yield in ar…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are photon detectors comprised of superconducting LC resonators with unique resonant frequencies corresponding to their geometrical structure. As each pixel has its own geometry, electromagnetic simulations by hand of every pixel in a kilo-pixel array are impractical. Simulating fewer pixels and interpolating in between risks reduced pixel yield in arrays due to overlapping resonant frequencies. We introduce a new software called AEM (Automated Electromagnetic MKID simulations) that automates the constructions and simulations of every simulated MKID pixel in an array according to specified resonant frequencies and a Qc range. We show automated designs to have an increased pixel yield (avoiding loses due to interpolation completely), increased accuracy in resonance frequency and Qc values when compared to interpolated structures. We also demonstrate a simulated trial of AEM for 100 MKIDs between 4 & 8 GHz to produce MKIDs with accuracies of +-0.2 MHz with a runtime of 10 hrs 45 mins.
△ Less
Submitted 15 May, 2024; v1 submitted 8 May, 2024;
originally announced May 2024.
-
Dark Matter Line Searches with the Cherenkov Telescope Array
Authors:
S. Abe,
J. Abhir,
A. Abhishek,
F. Acero,
A. Acharyya,
R. Adam,
A. Aguasca-Cabot,
I. Agudo,
A. Aguirre-Santaella,
J. Alfaro,
R. Alfaro,
N. Alvarez-Crespo,
R. Alves Batista,
J. -P. Amans,
E. Amato,
G. Ambrosi,
L. Angel,
C. Aramo,
C. Arcaro,
T. T. H. Arnesen,
L. Arrabito,
K. Asano,
Y. Ascasibar,
J. Aschersleben,
H. Ashkar
, et al. (540 additional authors not shown)
Abstract:
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of sele…
▽ More
Monochromatic gamma-ray signals constitute a potential smoking gun signature for annihilating or decaying dark matter particles that could relatively easily be distinguished from astrophysical or instrumental backgrounds. We provide an updated assessment of the sensitivity of the Cherenkov Telescope Array (CTA) to such signals, based on observations of the Galactic centre region as well as of selected dwarf spheroidal galaxies. We find that current limits and detection prospects for dark matter masses above 300 GeV will be significantly improved, by up to an order of magnitude in the multi-TeV range. This demonstrates that CTA will set a new standard for gamma-ray astronomy also in this respect, as the world's largest and most sensitive high-energy gamma-ray observatory, in particular due to its exquisite energy resolution at TeV energies and the adopted observational strategy focussing on regions with large dark matter densities. Throughout our analysis, we use up-to-date instrument response functions, and we thoroughly model the effect of instrumental systematic uncertainties in our statistical treatment. We further present results for other potential signatures with sharp spectral features, e.g.~box-shaped spectra, that would likewise very clearly point to a particle dark matter origin.
△ Less
Submitted 7 March, 2024;
originally announced March 2024.
-
Limitations to the energy resolution of single-photon sensitive Microwave Kinetic Inductance Detectors
Authors:
Mario De Lucia,
Gerhard Ulbricht,
Eoin Baldwin,
Jack Piercy,
Colm Bracken,
Oisin Creaner,
Tom Ray
Abstract:
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier no…
▽ More
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Chasing Gravitational Waves with the Cherenkov Telescope Array
Authors:
Jarred Gershon Green,
Alessandro Carosi,
Lara Nava,
Barbara Patricelli,
Fabian Schüssler,
Monica Seglar-Arroyo,
Cta Consortium,
:,
Kazuki Abe,
Shotaro Abe,
Atreya Acharyya,
Remi Adam,
Arnau Aguasca-Cabot,
Ivan Agudo,
Jorge Alfaro,
Nuria Alvarez-Crespo,
Rafael Alves Batista,
Jean-Philippe Amans,
Elena Amato,
Filippo Ambrosino,
Ekrem Oguzhan Angüner,
Lucio Angelo Antonelli,
Carla Aramo,
Cornelia Arcaro,
Luisa Arrabito
, et al. (545 additional authors not shown)
Abstract:
The detection of gravitational waves from a binary neutron star merger by Advanced LIGO and Advanced Virgo (GW170817), along with the discovery of the electromagnetic counterparts of this gravitational wave event, ushered in a new era of multimessenger astronomy, providing the first direct evidence that BNS mergers are progenitors of short gamma-ray bursts (GRBs). Such events may also produce very…
▽ More
The detection of gravitational waves from a binary neutron star merger by Advanced LIGO and Advanced Virgo (GW170817), along with the discovery of the electromagnetic counterparts of this gravitational wave event, ushered in a new era of multimessenger astronomy, providing the first direct evidence that BNS mergers are progenitors of short gamma-ray bursts (GRBs). Such events may also produce very-high-energy (VHE, > 100GeV) photons which have yet to be detected in coincidence with a gravitational wave signal. The Cherenkov Telescope Array (CTA) is a next-generation VHE observatory which aims to be indispensable in this search, with an unparalleled sensitivity and ability to slew anywhere on the sky within a few tens of seconds. New observing modes and follow-up strategies are being developed for CTA to rapidly cover localization areas of gravitational wave events that are typically larger than the CTA field of view. This work will evaluate and provide estimations on the expected number of of gravitational wave events that will be observable with CTA, considering both on- and off-axis emission. In addition, we will present and discuss the prospects of potential follow-up strategies with CTA.
△ Less
Submitted 5 February, 2024; v1 submitted 11 October, 2023;
originally announced October 2023.
-
Performance of the joint LST-1 and MAGIC observations evaluated with Crab Nebula data
Authors:
H. Abe,
K. Abe,
S. Abe,
V. A. Acciari,
A. Aguasca-Cabot,
I. Agudo,
N. Alvarez Crespo,
T. Aniello,
S. Ansoldi,
L. A. Antonelli,
C. Aramo,
A. Arbet-Engels,
C. Arcaro,
M. Artero,
K. Asano,
P. Aubert,
D. Baack,
A. Babić,
A. Baktash,
A. Bamba,
A. Baquero Larriva,
L. Baroncelli,
U. Barres de Almeida,
J. A. Barrio,
I. Batković
, et al. (344 additional authors not shown)
Abstract:
Aims. LST-1, the prototype of the Large-Sized Telescope for the upcoming Cherenkov Telescope Array Observatory, is concluding its commissioning in Observatorio del Roque de los Muchachos on the island of La Palma. The proximity of LST-1 (Large-Sized Telescope 1) to the two MAGIC (Major Atmospheric Gamma Imaging Cherenkov) telescopes permits observations of the same gamma-ray events with both syste…
▽ More
Aims. LST-1, the prototype of the Large-Sized Telescope for the upcoming Cherenkov Telescope Array Observatory, is concluding its commissioning in Observatorio del Roque de los Muchachos on the island of La Palma. The proximity of LST-1 (Large-Sized Telescope 1) to the two MAGIC (Major Atmospheric Gamma Imaging Cherenkov) telescopes permits observations of the same gamma-ray events with both systems. Methods. We describe the joint LST-1+MAGIC analysis pipeline and use simultaneous Crab Nebula observations and Monte Carlo simulations to assess the performance of the three-telescope system. The addition of the LST-1 telescope allows the recovery of events in which one of the MAGIC images is too dim to survive analysis quality cuts. Results. Thanks to the resulting increase in the collection area and stronger background rejection, we find a significant improvement in sensitivity, allowing the detection of 30% weaker fluxes in the energy range between 200 GeV and 3 TeV. The spectrum of the Crab Nebula, reconstructed in the energy range ~60 GeV to ~10 TeV, is in agreement with previous measurements.
△ Less
Submitted 3 October, 2023;
originally announced October 2023.
-
Prospects for $γ$-ray observations of the Perseus galaxy cluster with the Cherenkov Telescope Array
Authors:
The Cherenkov Telescope Array Consortium,
:,
K. Abe,
S. Abe,
F. Acero,
A. Acharyya,
R. Adam,
A. Aguasca-Cabot,
I. Agudo,
A. Aguirre-Santaella,
J. Alfaro,
R. Alfaro,
N. Alvarez-Crespo,
R. Alves Batista,
J. -P. Amans,
E. Amato,
E. O. Angüner,
L. A. Antonelli,
C. Aramo,
M. Araya,
C. Arcaro,
L. Arrabito,
K. Asano,
Y. Ascasíbar,
J. Aschersleben
, et al. (542 additional authors not shown)
Abstract:
Galaxy clusters are expected to be dark matter (DM) reservoirs and storage rooms for the cosmic-ray protons (CRp) that accumulate along the cluster's formation history. Accordingly, they are excellent targets to search for signals of DM annihilation and decay at gamma-ray energies and are predicted to be sources of large-scale gamma-ray emission due to hadronic interactions in the intracluster med…
▽ More
Galaxy clusters are expected to be dark matter (DM) reservoirs and storage rooms for the cosmic-ray protons (CRp) that accumulate along the cluster's formation history. Accordingly, they are excellent targets to search for signals of DM annihilation and decay at gamma-ray energies and are predicted to be sources of large-scale gamma-ray emission due to hadronic interactions in the intracluster medium. We estimate the sensitivity of the Cherenkov Telescope Array (CTA) to detect diffuse gamma-ray emission from the Perseus galaxy cluster. We perform a detailed spatial and spectral modelling of the expected signal for the DM and the CRp components. For each, we compute the expected CTA sensitivity. The observing strategy of Perseus is also discussed. In the absence of a diffuse signal (non-detection), CTA should constrain the CRp to thermal energy ratio within the radius $R_{500}$ down to about $X_{500}<3\times 10^{-3}$, for a spatial CRp distribution that follows the thermal gas and a CRp spectral index $α_{\rm CRp}=2.3$. Under the optimistic assumption of a pure hadronic origin of the Perseus radio mini-halo and depending on the assumed magnetic field profile, CTA should measure $α_{\rm CRp}$ down to about $Δα_{\rm CRp}\simeq 0.1$ and the CRp spatial distribution with 10% precision. Regarding DM, CTA should improve the current ground-based gamma-ray DM limits from clusters observations on the velocity-averaged annihilation cross-section by a factor of up to $\sim 5$, depending on the modelling of DM halo substructure. In the case of decay of DM particles, CTA will explore a new region of the parameter space, reaching models with $τ_χ>10^{27}$s for DM masses above 1 TeV. These constraints will provide unprecedented sensitivity to the physics of both CRp acceleration and transport at cluster scale and to TeV DM particle models, especially in the decay scenario.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
Frequency Domain Multiplexing for MKIDs: Comparing the Xilinx ZCU111 RFSoC with their new 2x2 RFSoC board
Authors:
Eoin Baldwin,
Mario De Lucia,
Colm Bracken,
Gerhard Ulbricht,
Oisin Creaner,
Jack Piercy,
Tom Ray
Abstract:
The Xilinx ZCU111 Radio Frequency System on Chip (RFSoC) is a promising solution for reading out large arrays of microwave kinetic inductance detectors (MKIDs). The board boasts eight on-chip 12-bit / 4.096 GSPS analogue-to-digital converters (ADCs) and eight 14-bit / 6.554 GSPS digital-to-analogue converters (DACs), as well as field programmable gate array (FPGA) resources of 930,000 logic cells…
▽ More
The Xilinx ZCU111 Radio Frequency System on Chip (RFSoC) is a promising solution for reading out large arrays of microwave kinetic inductance detectors (MKIDs). The board boasts eight on-chip 12-bit / 4.096 GSPS analogue-to-digital converters (ADCs) and eight 14-bit / 6.554 GSPS digital-to-analogue converters (DACs), as well as field programmable gate array (FPGA) resources of 930,000 logic cells and 4,272 digital signal processing (DSP) slices. While this is sufficient data converter bandwidth for the readout of 8,000 MKIDs, with a 2 MHz channel-spacing, and a 1 MHz sampling rate (per channel), additional FPGA resources are needed to perform the DSP needed to process this large number of MKIDs. A solution to this problem is the new Xilinx RFSoC 2x2 board. This board costs only one fifth of the ZCU111 while still providing the same logic resources as the ZCU111, albeit with only a quarter of the data converter resources. Thus, using multiple RFSoC 2x2 boards would provide a better balance between FPGA resources and data converters, allowing the full utilization of the RF bandwidth provided by the data converters, while also lowering the cost per pixel value of the readout system, from approximately EUR2.50 per pixel with the ZCU111, to EUR1 per pixel.
△ Less
Submitted 23 January, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
High-uniformity TiN/Ti/TiN multilayers for the development of Microwave Kinetic Inductance Detector
Authors:
Mario De Lucia,
E. Baldwin,
G. Ulbricht,
J. D. Piercy,
O. Creaner,
C. Bracken,
T. P. Ray
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are a class of superconducting cryogenic detectors that simultaneously exhibit energy resolution, time resolution and spatial resolution. The pixel yield of MKID arrays is usually a critical figure of merit in the characterisation of an MKIDs array. Currently, for MKIDs intended for the detection of optical and near-infrared photons, only the best arr…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are a class of superconducting cryogenic detectors that simultaneously exhibit energy resolution, time resolution and spatial resolution. The pixel yield of MKID arrays is usually a critical figure of merit in the characterisation of an MKIDs array. Currently, for MKIDs intended for the detection of optical and near-infrared photons, only the best arrays exhibit a pixel yield as high as 75-80%. The uniformity of the superconducting film used for the fabrication of MKIDs arrays is often regarded as the main limiting factor to the pixel yield of an array. In this paper we will present data on the uniformity of the TiN/Ti/TiN multilayers deposited at the Tyndall National Institute and compare these results with a statistical model that evaluates how inhomogeneities affect the pixel yield of an array.
△ Less
Submitted 19 January, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
Repurposing ROACH-1 boards for prototyping of readout systems for optical-NIR MKIDs
Authors:
Oisín Creaner,
Colm Bracken,
Jack Piercy,
Gerhard Ulbricht,
Eoin Baldwin,
Mario De Lucia,
Tom Ray
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are cryogenic photon detectors and are attractive because they permit simultaneous time, energy and spatial resolution of faint astronomical sources. We present a cost-effective alternative to dedicated (e.g. analogue) electronics for prototyping readout of single-pixel Optical/NIR MKIDs by repurposing existing and well-known ROACH-1 boards. We also p…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are cryogenic photon detectors and are attractive because they permit simultaneous time, energy and spatial resolution of faint astronomical sources. We present a cost-effective alternative to dedicated (e.g. analogue) electronics for prototyping readout of single-pixel Optical/NIR MKIDs by repurposing existing and well-known ROACH-1 boards. We also present a pipeline that modernises previously-developed software and data frameworks to allow for extensiblity to new applications and portability to new hardware (e.g. Xilinx ZCU111 or 2x2 RFSoC boards).
△ Less
Submitted 17 January, 2023;
originally announced January 2023.
-
Modeling Results and Baseline Design for an RF-SoC-Based Readout System for Microwave Kinetic Inductance Detectors
Authors:
Colm Bracken,
Eoin Baldwin,
Gerhard Ulbricht,
Mario de Lucia,
Tom Ray
Abstract:
Building upon existing signal processing techniques and open-source software, this paper presents a baseline design for an RF System-on-Chip Frequency Division Multiplexed readout for a spatio-spectral focal plane instrument based on low temperature detectors. A trade-off analysis of different FPGA carrier boards is presented in an attempt to find an optimum next-generation solution for reading ou…
▽ More
Building upon existing signal processing techniques and open-source software, this paper presents a baseline design for an RF System-on-Chip Frequency Division Multiplexed readout for a spatio-spectral focal plane instrument based on low temperature detectors. A trade-off analysis of different FPGA carrier boards is presented in an attempt to find an optimum next-generation solution for reading out larger arrays of Microwave Kinetic Inductance Detectors (MKIDs). The ZCU111 RF SoC FPGA board from Xilinx was selected, and it is shown how this integrated system promises to increase the number of pixels that can be read out (per board) which enables a reduction in the readout cost per pixel, the mass and volume, and power consumption, all of which are important in making MKID instruments more feasible for both ground-based and space-based astrophysics. The on-chip logic capacity is shown to form a primary constraint on the number of MKIDs which can be read, channelised, and processed with this new system. As such, novel signal processing techniques are analysed, including Digitally Down Converted (DDC)-corrected sub-maximally decimated sampling, in an effort to reduce logic requirements without compromising signal to noise ratio. It is also shown how combining the ZCU111 board with a secondary FPGA board will allow all 8 ADCs and 8 DACs to be utilised, providing enough bandwidth to read up to 8,000 MKIDs per board-set, an eight-fold improvement over the state-of-the-art, and important in pursuing 100,000 pixel arrays. Finally, the feasibility of extending the operational frequency range of MKIDs to the 5 - 10 GHz regime (or possibly beyond) is investigated, and some benefits and consequences of doing so are presented.
△ Less
Submitted 9 February, 2023; v1 submitted 15 December, 2022;
originally announced December 2022.
-
Multiplexable frequency retuning of MKID arrays using their non-linear kinetic inductance
Authors:
Mario De Lucia,
Eoin Baldwin,
Gerhard Ulbricht,
Colm Bracken,
Plamen Stamenov,
Tom Ray
Abstract:
Microwave Kinetic Inductance Detector (MKID) arrays are currently being developed and deployed for astronomical applications in the visible and near infrared and for sub-millimetre astronomy. One of the main drawbacks of MKIDs is that large arrays would exhibit a pixel yield, the percentage of individually distinguishable pixels to the total number of pixels, of 75 - 80 %. Imperfections arising du…
▽ More
Microwave Kinetic Inductance Detector (MKID) arrays are currently being developed and deployed for astronomical applications in the visible and near infrared and for sub-millimetre astronomy. One of the main drawbacks of MKIDs is that large arrays would exhibit a pixel yield, the percentage of individually distinguishable pixels to the total number of pixels, of 75 - 80 %. Imperfections arising during the fabrication can induce an uncontrolled shift in the resonance frequency of individual resonators which can end up resonating at the same frequency of a different resonator. This makes a number of resonators indistinguishable and therefore unusable for imaging. This paper proposes an approach to individually re-tune the colliding resonators in order to remove the degeneracy and increase the number of MKIDs with unique resonant frequencies. The frequency re-tuning is achieved through a DC bias of the resonator, the kinetic inductance of a superconducting thin film is current dependent and its dependence is non linear. Even though this approach has been already proposed, an innovative pixel design, described in this paper, may solve two issues previously described in literature such as increased electromagnetic losses to the DC-bias line, and the multiplexibility of multiple resonators on a single feedline.
△ Less
Submitted 12 April, 2022;
originally announced April 2022.
-
Applications for Microwave Kinetic Induction Detectors in Advanced Instrumentation
Authors:
Gerhard Ulbricht,
Mario De Lucia,
Eoin Baldwin
Abstract:
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKI…
▽ More
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKID based projects are ongoing or proposed for observational astronomy, particle physics, material science and THz imaging, and the goal of this review is to provide an easily usable and thorough list of possible starting points for more in-depth literature research on the many areas profiting from kinetic inductance detectors.
△ Less
Submitted 16 November, 2021;
originally announced November 2021.
-
Science with the Cherenkov Telescope Array
Authors:
The Cherenkov Telescope Array Consortium,
:,
B. S. Acharya,
I. Agudo,
I. Al Samarai,
R. Alfaro,
J. Alfaro,
C. Alispach,
R. Alves Batista,
J. -P. Amans,
E. Amato,
G. Ambrosi,
E. Antolini,
L. A. Antonelli,
C. Aramo,
M. Araya,
T. Armstrong,
F. Arqueros,
L. Arrabito,
K. Asano,
M. Ashley,
M. Backes,
C. Balazs,
M. Balbo,
O. Ballester
, et al. (558 additional authors not shown)
Abstract:
The Cherenkov Telescope Array, CTA, will be the major global observatory for very high energy gamma-ray astronomy over the next decade and beyond. The scientific potential of CTA is extremely broad: from understanding the role of relativistic cosmic particles to the search for dark matter. CTA is an explorer of the extreme universe, probing environments from the immediate neighbourhood of black ho…
▽ More
The Cherenkov Telescope Array, CTA, will be the major global observatory for very high energy gamma-ray astronomy over the next decade and beyond. The scientific potential of CTA is extremely broad: from understanding the role of relativistic cosmic particles to the search for dark matter. CTA is an explorer of the extreme universe, probing environments from the immediate neighbourhood of black holes to cosmic voids on the largest scales. Covering a huge range in photon energy from 20 GeV to 300 TeV, CTA will improve on all aspects of performance with respect to current instruments.
The observatory will operate arrays on sites in both hemispheres to provide full sky coverage and will hence maximize the potential for the rarest phenomena such as very nearby supernovae, gamma-ray bursts or gravitational wave transients. With 99 telescopes on the southern site and 19 telescopes on the northern site, flexible operation will be possible, with sub-arrays available for specific tasks. CTA will have important synergies with many of the new generation of major astronomical and astroparticle observatories. Multi-wavelength and multi-messenger approaches combining CTA data with those from other instruments will lead to a deeper understanding of the broad-band non-thermal properties of target sources.
The CTA Observatory will be operated as an open, proposal-driven observatory, with all data available on a public archive after a pre-defined proprietary period. Scientists from institutions worldwide have combined together to form the CTA Consortium. This Consortium has prepared a proposal for a Core Programme of highly motivated observations. The programme, encompassing approximately 40% of the available observing time over the first ten years of CTA operation, is made up of individual Key Science Projects (KSPs), which are presented in this document.
△ Less
Submitted 21 January, 2018; v1 submitted 22 September, 2017;
originally announced September 2017.
-
Cherenkov Telescope Array Contributions to the 35th International Cosmic Ray Conference (ICRC2017)
Authors:
F. Acero,
B. S. Acharya,
V. Acín Portella,
C. Adams,
I. Agudo,
F. Aharonian,
I. Al Samarai,
A. Alberdi,
M. Alcubierre,
R. Alfaro,
J. Alfaro,
C. Alispach,
R. Aloisio,
R. Alves Batista,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
M. Anduze,
E. O. Angüner,
E. Antolini,
L. A. Antonelli,
V. Antonuccio
, et al. (1117 additional authors not shown)
Abstract:
List of contributions from the Cherenkov Telescope Array Consortium presented at the 35th International Cosmic Ray Conference, July 12-20 2017, Busan, Korea.
List of contributions from the Cherenkov Telescope Array Consortium presented at the 35th International Cosmic Ray Conference, July 12-20 2017, Busan, Korea.
△ Less
Submitted 24 October, 2017; v1 submitted 11 September, 2017;
originally announced September 2017.