Timing Calibration of the NuSTAR X-ray Telescope
Authors:
Matteo Bachetti,
Craig B. Markwardt,
Brian W. Grefenstette,
Eric V. Gotthelf,
Lucien Kuiper,
Didier Barret,
W. Rick Cook,
Andrew Davis,
Felix Fürst,
Karl Forster,
Fiona A. Harrison,
Kristin K. Madsen,
Hiromasa Miyasaka,
Bryce Roberts,
John A. Tomsick,
Dominic J. Walton
Abstract:
The Nuclear Spectroscopic Telescope Array (NuSTAR) mission is the first focusing X-ray telescope in the hard X-ray (3-79 keV) band. Among the phenomena that can be studied in this energy band, some require high time resolution and stability: rotation-powered and accreting millisecond pulsars, fast variability from black holes and neutron stars, X-ray bursts, and more. Moreover, a good alignment of…
▽ More
The Nuclear Spectroscopic Telescope Array (NuSTAR) mission is the first focusing X-ray telescope in the hard X-ray (3-79 keV) band. Among the phenomena that can be studied in this energy band, some require high time resolution and stability: rotation-powered and accreting millisecond pulsars, fast variability from black holes and neutron stars, X-ray bursts, and more. Moreover, a good alignment of the timestamps of X-ray photons to UTC is key for multi-instrument studies of fast astrophysical processes. In this Paper, we describe the timing calibration of the NuSTAR mission. In particular, we present a method to correct the temperature-dependent frequency response of the on-board temperature-compensated crystal oscillator. Together with measurements of the spacecraft clock offsets obtained during downlinks passes, this allows a precise characterization of the behavior of the oscillator. The calibrated NuSTAR event timestamps for a typical observation are shown to be accurate to a precision of ~65 microsec.
△ Less
Submitted 24 February, 2021; v1 submitted 22 September, 2020;
originally announced September 2020.
-
The Nuclear Spectroscopic Telescope Array (NuSTAR) Mission
Authors:
Fiona A. Harrison,
William W. Craig,
Finn E. Christensen,
Charles J. Hailey,
Will W. Zhang,
Steven E. Boggs,
Daniel Stern,
W. Rick Cook,
Karl Forster,
Paolo Giommi,
Brian W. Grefenstette,
Yunjin Kim,
Takao Kitaguchi,
Jason E Koglin,
Kristin K. Madsen,
Peter H. Mao,
Hiromasa Miyasaka,
Kaya Mori,
Matteo Perri,
Michael J. Pivovaroff,
Simonetta Puccetti,
Vikram R. Rana,
Niels J. Westergaard,
Jason Willis,
Andreas Zoglauer
, et al. (55 additional authors not shown)
Abstract:
The Nuclear Spectroscopic Telescope Array (NuSTAR) mission, launched on 13 June 2012, is the first focusing high-energy X-ray telescope in orbit. NuSTAR operates in the band from 3 -- 79 keV, extending the sensitivity of focusing far beyond the ~10 keV high-energy cutoff achieved by all previous X-ray satellites. The inherently low-background associated with concentrating the X-ray light enables N…
▽ More
The Nuclear Spectroscopic Telescope Array (NuSTAR) mission, launched on 13 June 2012, is the first focusing high-energy X-ray telescope in orbit. NuSTAR operates in the band from 3 -- 79 keV, extending the sensitivity of focusing far beyond the ~10 keV high-energy cutoff achieved by all previous X-ray satellites. The inherently low-background associated with concentrating the X-ray light enables NuSTAR to probe the hard X-ray sky with a more than one-hundred-fold improvement in sensitivity over the collimated or coded-mask instruments that have operated in this bandpass. Using its unprecedented combination of sensitivity, spatial and spectral resolution, NuSTAR will pursue five primary scientific objectives, and will also undertake a broad program of targeted observations. The observatory consists of two co-aligned grazing-incidence X-ray telescopes pointed at celestial targets by a three-axis stabilized spacecraft. Deployed into a 600 km, near-circular, 6degree inclination orbit, the Observatory has now completed commissioning, and is performing consistent with pre-launch expectations. NuSTAR is now executing its primary science mission, and with an expected orbit lifetime of ten years, we anticipate proposing a guest investigator program, to begin in Fall 2014.
△ Less
Submitted 30 January, 2013;
originally announced January 2013.
-
Spectral calibration and modeling of the NuSTAR CdZnTe pixel detectors
Authors:
Takao Kitaguchi,
Brian W. Grefenstette,
Fiona A. Harrison,
Hiromasa Miyasaka,
Varun B. Bhalerao,
Walter R. Cook III,
Peter H. Mao,
Vikram R. Rana,
Steven E. Boggs,
Andreas C. Zoglauer
Abstract:
The Nuclear Spectroscopic Telescope Array (NuSTAR) will be the first space mission to focus in the hard X-ray (5-80 keV) band. The NuSTAR instrument carries two co-aligned grazing incidence hard X-ray telescopes. Each NuSTAR focal plane consists of four 2 mm CdZnTe hybrid pixel detectors, each with an active collecting area of 2 cm x 2 cm. Each hybrid consists of a 32 x 32 array of 605 micron pixe…
▽ More
The Nuclear Spectroscopic Telescope Array (NuSTAR) will be the first space mission to focus in the hard X-ray (5-80 keV) band. The NuSTAR instrument carries two co-aligned grazing incidence hard X-ray telescopes. Each NuSTAR focal plane consists of four 2 mm CdZnTe hybrid pixel detectors, each with an active collecting area of 2 cm x 2 cm. Each hybrid consists of a 32 x 32 array of 605 micron pixels, read out with the Caltech custom low-noise NuCIT ASIC. In order to characterize the spectral response of each pixel to the degree required to meet the science calibration requirements, we have developed a model based on Geant4 together with the Shockley-Ramo theorem customized to the NuSTAR hybrid design. This model combines a Monte Carlo of the X-ray interactions with subsequent charge transport within the detector. The combination of this model and calibration data taken using radioactive sources of Co-57, Eu-155 and Am-241 enables us to determine electron and hole mobility-lifetime products for each pixel, and to compare actual to ideal performance expected for defect-free material.
△ Less
Submitted 5 September, 2011; v1 submitted 2 September, 2011;
originally announced September 2011.
-
ProtoEXIST: Advanced Prototype CZT Coded Aperture Telescopes for EXIST
Authors:
Branden Allen,
Jaesub Hong,
Josh Grindlay,
Scott D. Barthelmy,
Robert G. Baker,
Neil A. Gehrels,
Trey Garson,
Henric S. Krawwczynski,
Walter R. Cook,
Fiona A. Harrison,
Jeffery A. Apple,
Brian D. Ramsey
Abstract:
{\it ProtoEXIST1} is a pathfinder for the {\it EXIST-HET}, a coded aperture hard X-ray telescope with a 4.5 m$^2$ CZT detector plane a 90$\times$70 degree field of view to be flown as the primary instrument on the {\it EXIST} mission and is intended to monitor the full sky every 3 h in an effort to locate GRBs and other high energy transients. {\it ProtoEXIST1} consists of a 256 cm$^2$ tiled CZT d…
▽ More
{\it ProtoEXIST1} is a pathfinder for the {\it EXIST-HET}, a coded aperture hard X-ray telescope with a 4.5 m$^2$ CZT detector plane a 90$\times$70 degree field of view to be flown as the primary instrument on the {\it EXIST} mission and is intended to monitor the full sky every 3 h in an effort to locate GRBs and other high energy transients. {\it ProtoEXIST1} consists of a 256 cm$^2$ tiled CZT detector plane containing 4096 pixels composed of an 8$\times$8 array of individual 1.95 cm $\times$ 1.95 cm $\times$ 0.5 cm CZT detector modules each with a 8 $\times$ 8 pixilated anode configured as a coded aperture telescope with a fully coded $10^\circ\times10^\circ$ field of view employing passive side shielding and an active CsI anti-coincidence rear shield, recently completed its maiden flight out of Ft. Sumner, NM on the 9th of October 2009. During the duration of its 6 hour flight on-board calibration of the detector plane was carried out utilizing a single tagged 198.8 nCi Am-241 source along with the simultaneous measurement of the background spectrum and an observation of Cygnus X-1. Here we recount the events of the flight and report on the detector performance in a near space environment. We also briefly discuss {\it ProtoEXIST2}: the next stage of detector development which employs the {\it NuSTAR} ASIC enabling finer (32$\times$32) anode pixilation. When completed {\it ProtoEXIST2} will consist of a 256 cm$^2$ tiled array and be flown simultaneously with the ProtoEXIST1 telescope.
△ Less
Submitted 14 September, 2010;
originally announced September 2010.
-
The Nuclear Spectroscopic Telescope Array (NuSTAR)
Authors:
Fiona A. Harrison,
Steven Boggs,
Finn Christensen,
William Craig,
Charles Hailey,
Daniel Stern,
William Zhang,
Lorella Angelini,
HongJun An,
Varun Bhalereo,
Nicolai Brejnholt,
Lynn Cominsky,
W. Rick Cook,
Melania Doll,
Paolo Giommi,
Brian Grefenstette,
Allan Hornstrup,
Victoria M. Kaspi,
Yunjin Kim,
Takao Kitaguchi,
Jason Koglin,
Carl Christian Liebe,
Greg Madejski,
Kristin Kruse Madsen,
Peter Mao
, et al. (8 additional authors not shown)
Abstract:
The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5 -- 80 keV) telescope to orbit. NuSTAR will offer a factor 50 -- 100 sensitivity improvement compared to previous collimated or coded mask imagers that have operated in this energy band. In addition, NuSTAR provides sub-arcminute imaging with good spectral resolution…
▽ More
The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5 -- 80 keV) telescope to orbit. NuSTAR will offer a factor 50 -- 100 sensitivity improvement compared to previous collimated or coded mask imagers that have operated in this energy band. In addition, NuSTAR provides sub-arcminute imaging with good spectral resolution over a 12-arcminute field of view. After launch, NuSTAR will carry out a two-year primary science mission that focuses on four key programs: studying the evolution of massive black holes through surveys carried out in fields with excellent multiwavelength coverage, understanding the population of compact objects and the nature of the massive black hole in the center of the Milky Way, constraining explosion dynamics and nucleosynthesis in supernovae, and probing the nature of particle acceleration in relativistic jets in active galactic nuclei. A number of additional observations will be included in the primary mission, and a guest observer program will be proposed for an extended mission to expand the range of scientific targets. The payload consists of two co-aligned depth-graded multilayer coated grazing incidence optics focused onto solid state CdZnTe pixel detectors. To be launched in early 2012 on a Pegasus rocket into a low-inclination Earth orbit. Data will be publicly available at GSFC's High Energy Astrophysics Science Archive Research Center (HEASARC) following validation at the science operations center located at Caltech.
△ Less
Submitted 7 August, 2010;
originally announced August 2010.
-
Building Large Area CZT Imaging Detectors for a Wide-Field Hard X-ray Telescope - ProtoEXIST1
Authors:
J. Hong,
B. Allen,
J. Grindlay,
N. Chammas,
S. Barthelemy,
R. Baker,
N. Gehrels,
K. E. Nelson,
S. Labov,
J. Collins,
W. R. Cook,
R. McLean,
F. Harrison
Abstract:
We have constructed a moderately large area (32 cm2), fine pixel (2.5 mm pixel, 5 mm thick) CZT imaging detector which constitutes the first section of a detector module (256 cm2) developed for a balloon-borne wide-field hard X-ray telescope, ProtoEXIST1. ProtoEXIST1 is a prototype for the High Energy Telescope (HET) in the Energetic X-ray imaging Survey Telescope (EXIST), a next generation spac…
▽ More
We have constructed a moderately large area (32 cm2), fine pixel (2.5 mm pixel, 5 mm thick) CZT imaging detector which constitutes the first section of a detector module (256 cm2) developed for a balloon-borne wide-field hard X-ray telescope, ProtoEXIST1. ProtoEXIST1 is a prototype for the High Energy Telescope (HET) in the Energetic X-ray imaging Survey Telescope (EXIST), a next generation space-borne multi-wavelength telescope. We have constructed a large (nearly gapless) detector plane through a modularization scheme by tiling of a large number of 2 cm x 2 cm CZT crystals. Our innovative packaging method is ideal for many applications such as coded-aperture imaging, where a large, continuous detector plane is desirable for the optimal performance. Currently we have been able to achieve an energy resolution of 3.2 keV (FWHM) at 59.6 keV on average, which is exceptional considering the moderate pixel size and the number of detectors in simultaneous operation. We expect to complete two modules (512 cm2) within the next few months as more CZT becomes available. We plan to test the performance of these detectors in a near space environment in a series of high altitude balloon flights, the first of which is scheduled for Fall 2009. These detector modules are the first in a series of progressively more sophisticated detector units and packaging schemes planned for ProtoEXIST2 & 3, which will demonstrate the technology required for the advanced CZT imaging detectors (0.6 mm pixel, 4.5 m2 area) required in EXIST/HET.
△ Less
Submitted 3 April, 2009; v1 submitted 31 March, 2009;
originally announced March 2009.
-
Wide Field Hard X-ray Survey Telescope: ProtoEXIST1
Authors:
J. Hong,
J. E. Grindlay,
N. Chammas,
B. Allen,
A. Copete,
B. Said,
M. Burke,
J. Howell,
T. Gauron,
R. G. Baker,
S. D. Barthelmy,
S. Sheikh,
N. Gehrels,
W. R. Cook,
J. A. Burnham,
F. A. Harrison,
J. Collins,
S. Labov,
A. Garson III,
H. Krawczynski
Abstract:
We report our progress on the development of pixellated imaging CZT detector arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope (EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1 consists of…
▽ More
We report our progress on the development of pixellated imaging CZT detector arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope (EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1 consists of four independent coded-aperture telescopes with close-tiled (~0.4 mm gaps) CZT detectors that preserve their 2.5mm pixel pitch. Multiple shielding/field-of-view configurations are planned to identify optimal geometry for the HET in EXIST. The primary technical challenge in ProtoEXIST is the development of large area, close-tiled modules of imaging CZT detectors (1000 cm2 for ProtoEXIST1), with all readout and control systems for the ASIC readout vertically stacked. We describe the overall telescope configuration of ProtoEXIST1 and review the current development status of the CZT detectors, from individual detector crystal units (DCUs) to a full detector module (DM). We have built the first units of each component for the detector plane and have completed a few Rev2 DCUs (2x2 cm2), which are under a series of tests. Bare DCUs (pre-crystal bonding) show high, uniform ASIC yield (~70%) and ~30% reduction in electronics noise compared to the Rev1 equivalent. A Rev1 DCU already achieved ~1.2% FWHM at 662 keV, and preliminary analysis of the initial radiation tests on a Rev2 DCU shows ~ 4 keV FWHM at 60 keV (vs. 4.7 keV for Rev1). We therefore expect about <~1% FWHM at 662 keV with the Rev2 detectors.
△ Less
Submitted 17 September, 2007;
originally announced September 2007.
-
CZT imaging detectors for ProtoEXIST
Authors:
J. Hong,
J. E. Grindlay,
N. Chammas,
A. Copete,
R. G. Baker,
S. D. Barthelmy,
N. Gehrels,
W. R. Cook,
J. A. Burnham,
F. A. Harrison,
J. Collins,
W. W. Craig
Abstract:
We describe the detector development for a balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT detec…
▽ More
We describe the detector development for a balloon-borne wide-field hard X-ray (20 - 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT detectors (1000 cm2 for ProtoEXIST1). We review the updates of the detector design and package concept for ProtoEXIST1 and report the current development status of the CZT detectors, using calibration results of our basic detector unit - 2 x 2 x 0.5 cm CZT crystals with 2.5 mm pixels (8 x 8 array). The current prototype (Rev1) of our detector crystal unit (DCU) shows ~4.5 keV electronics noise (FWHM), and the radiation measurements show the energy resolution (FWHM) of the units is 4.7 keV (7.9%) at 59.5 keV, 5.6 keV (4.6%) at 122 keV, and 7.6 keV (2.1%) at 356 keV. The new (Rev2) DCU with revised design is expected to improve the resolution by ~30%.
△ Less
Submitted 31 August, 2006;
originally announced August 2006.
-
Detector and Telescope Development for ProtoEXIST and Fine Beam Measurements of Spectral Response of CZT Detectors
Authors:
J. Hong,
A. Copete,
J. E. Grindlay,
S. V. Vadawale,
W. W. Craig,
F. Harrison,
W. R. Cook,
N. Gehrels
Abstract:
We outline our plan to develop ProtoEXIST, a balloon-borne prototype experiment for the Energetic X-ray Imaging Survey Telescope (EXIST) for the Black Hole Finder Probe. EXIST will consist of multiple wide-field hard X-ray coded-aperture telescopes. The current design of the EXIST mission employs two types of telescope systems: high energy telescopes (HETs) using CZT detectors, and low energy te…
▽ More
We outline our plan to develop ProtoEXIST, a balloon-borne prototype experiment for the Energetic X-ray Imaging Survey Telescope (EXIST) for the Black Hole Finder Probe. EXIST will consist of multiple wide-field hard X-ray coded-aperture telescopes. The current design of the EXIST mission employs two types of telescope systems: high energy telescopes (HETs) using CZT detectors, and low energy telescopes (LETs) using Si detectors. With ProtoEXIST, we will develop and demonstrate the technologies required for the EXIST HETs. As part of our development efforts, we also present recent laboratory measurements of the spectral response and efficiency variation of imaging CZT detectors on a fine scale (~0.5 mm). The preliminary results confirm the need for multi-pixel readouts and small inter-pixel gaps to achieve uniform spectral response and high detection efficiency across detectors.
△ Less
Submitted 26 September, 2005;
originally announced September 2005.
-
Development of Uniform CdTe Pixel Detectors Based on Caltech ASIC
Authors:
K. Oonuki,
H. Inoue,
K. Nakazawa,
T. Mitani,
T. Tanaka,
T. Takahashi,
C. M. H. Chen,
W. R. Cook,
F. A. Harrison
Abstract:
We have developed a large CdTe pixel detector with dimensions of 23.7 x 13.0 mm and a pixel size of 448 x 448 um^2. The detector is based on recent technologies of an uniform CdTe single crystal, a two-dimensional ASIC, and stud bump-bonding to connect pixel electrodes on the CdTe surface to the ASIC. Good spectra are obtained from 1051 pixels out of total 1056 pixels. When we operate the detect…
▽ More
We have developed a large CdTe pixel detector with dimensions of 23.7 x 13.0 mm and a pixel size of 448 x 448 um^2. The detector is based on recent technologies of an uniform CdTe single crystal, a two-dimensional ASIC, and stud bump-bonding to connect pixel electrodes on the CdTe surface to the ASIC. Good spectra are obtained from 1051 pixels out of total 1056 pixels. When we operate the detector at -50 C, the energy resolution is 0.67 keV and 0.99 keV at 14 keV and 60 keV, respectively. Week-long stability of the detector is confirmed at operating temperatures of both -50 C and -20 C. The detector also shows high uniformity: the peak positions for all pixels agree to within 0.82%, and the average of the energy resolution is 1.04 keV at a temperature of -50 C. When we normalized the peak area by the total counts detected by each pixel, a variation of 2.1 % is obtained.
△ Less
Submitted 2 October, 2004;
originally announced October 2004.