-
X-ray Polarimetry of the accreting pulsar 1A~0535+262 in the supercritical state with PolarLight
Authors:
Xiangyun Long,
Hua Feng,
Hong Li,
Ling-Da Kong,
Jeremy Heyl,
Long Ji,
Lian Tao,
Fabio Muleri,
Qiong Wu,
Jiahuan Zhu,
Jiahui Huang,
Massimo Minuti,
Weichun Jiang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgrò,
Gloria Spandre
, et al. (3 additional authors not shown)
Abstract:
The X-ray pulsar 1A 0535+262 exhibited a giant outburst in 2020, offering us a unique opportunity for X-ray polarimetry of an accreting pulsar in the supercritical state. Measurement with PolarLight yielded a non-detection in 3-8 keV; the 99% upper limit of the polarization fraction (PF) is found to be 0.34 averaged over spin phases, or 0.51 based on the rotating vector model. No useful constraint…
▽ More
The X-ray pulsar 1A 0535+262 exhibited a giant outburst in 2020, offering us a unique opportunity for X-ray polarimetry of an accreting pulsar in the supercritical state. Measurement with PolarLight yielded a non-detection in 3-8 keV; the 99% upper limit of the polarization fraction (PF) is found to be 0.34 averaged over spin phases, or 0.51 based on the rotating vector model. No useful constraint can be placed with phase resolved polarimetry. These upper limits are lower than a previous theoretical prediction of 0.6-0.8, but consistent with those found in other accreting pulsars, like Her X-1, Cen X-3, 4U 1626-67, and GRO J1008-57, which were in the subcritical state, or at least not confidently in the supercritical state, during the polarization measurements. Our results suggest that the relatively low PF seen in accreting pulsars cannot be attributed to the source not being in the supercritical state, but could be a general feature.
△ Less
Submitted 26 April, 2023;
originally announced April 2023.
-
Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation
Authors:
Alessandro Di Marco,
Sergio Fabiani,
Fabio La Monaca,
Fabio Muleri,
John Rankin,
Paolo Soffitta,
Fei Xie,
Fabrizio Amici,
Primo attinà,
Matteo Bachetti,
Luca Baldini,
Mattia Barbanera,
Wayne Baumgartner,
Ronaldo Bellazzini,
Fabio Borotto,
Alessandro Brez,
Daniele Brienza,
Ciro Caporale,
Claudia Cardelli,
Rita Carpentiero,
Simone Castellano,
Marco Castronuovo,
Luca Cavalli,
Elisabetta Cavazzuti,
Marco Ceccanti
, et al. (58 additional authors not shown)
Abstract:
IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by…
▽ More
IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.
△ Less
Submitted 15 June, 2022;
originally announced June 2022.
-
A significant detection of X-ray Polarization in Sco X-1 with PolarLight and constraints on the corona geometry
Authors:
Xiangyun Long,
Hua Feng,
Hong Li,
Jiahuan Zhu,
Qiong Wu,
Jiahui Huang,
Massimo Minuti,
Weichun Jiang,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Jiachen Jiang,
Enrico Costa,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri
, et al. (1 additional authors not shown)
Abstract:
We report the detection of X-ray polarization in the neutron star low mass X-ray binary Scorpius (Sco) X-1 with PolarLight. The result is energy dependent, with a non-detection in 3-4 keV but a 4$σ$ detection in 4-8 keV; it is also flux dependent in the 4-8 keV band, with a non-detection when the source displays low fluxes but a 5$σ$ detection during high fluxes, in which case we obtain a polariza…
▽ More
We report the detection of X-ray polarization in the neutron star low mass X-ray binary Scorpius (Sco) X-1 with PolarLight. The result is energy dependent, with a non-detection in 3-4 keV but a 4$σ$ detection in 4-8 keV; it is also flux dependent in the 4-8 keV band, with a non-detection when the source displays low fluxes but a 5$σ$ detection during high fluxes, in which case we obtain a polarization fraction of $0.043 \pm 0.008$ and a polarization angle of $52.6^\circ \pm 5.4^\circ$. This confirms a previous marginal detection with OSO-8 in the 1970s, and marks Sco X-1 the second astrophysical source with a significant polarization measurement in the keV band. The measured polarization angle is in line with the jet orientation of the source on the sky plane ($54^\circ$), which is supposedly the symmetric axis of the system. Combining previous spectral analysis, our measurements suggest that an optically thin corona is located in the transition layer under the highest accretion rates, and disfavor the extended accretion disk corona model.
△ Less
Submitted 6 December, 2021;
originally announced December 2021.
-
The Imaging X-Ray Polarimetry Explorer (IXPE): Pre-Launch
Authors:
Martin C. Weisskopf,
Paolo Soffitta,
Luca Baldini,
Brian D. Ramsey,
Stephen L. O'Dell,
Roger W. Romani,
Giorgio Matt,
William D. Deininger,
Wayne H. Baumgartner,
Ronaldo Bellazzini,
Enrico Costa,
Jeffery J. Kolodziejczak,
Luca Latronico,
Herman L. Marshall,
Fabio Muleri,
Stephen D. Bongiorno,
Allyn Tennant,
Niccolo Bucciantini,
Michal Dovciak,
Frederic Marin,
Alan Marscher,
Juri Poutanen,
Pat Slane,
Roberto Turolla,
William Kalinowski
, et al. (133 additional authors not shown)
Abstract:
Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the…
▽ More
Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the focus. A coilable boom, deployed on orbit, provides the necessary 4-m focal length. The observatory utilizes a 3-axis-stabilized spacecraft which provides services such as power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of X-ray sources, with follow-on observations of selected targets.
△ Less
Submitted 21 December, 2021; v1 submitted 2 December, 2021;
originally announced December 2021.
-
The Instrument of the Imaging X-ray Polarimetry Explorer
Authors:
Paolo Soffitta,
Luca Baldini,
Ronaldo Bellazzini,
Enrico Costa,
Luca Latronico,
Fabio Muleri,
Ettore Del Monte,
Sergio Fabiani,
Massimo Minuti,
Michele Pinchera,
Carmelo Sgrò,
Gloria Spandre,
Alessio Trois,
Fabrizio Amici,
Hans Andersson,
Primo Attinà,
Matteo Bachetti,
Mattia Barbanera,
Fabio Borotto,
Alessandro Brez,
Daniele Brienza,
Ciro Caporale,
Claudia Cardelli,
Rita Carpentiero,
Simone Castellano
, et al. (56 additional authors not shown)
Abstract:
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detecto…
▽ More
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, in part due to the fate of approved missions and in part because the celestial X-ray sources appeared less polarized than expected. Only one positive measurement has been available until now. Indeed the eight Orbiting Solar Observatory measured the polarization of the Crab nebula in the 70s.
The advent of techniques of microelectronics allowed for designing a detector based on the photoelectric effect in gas in an energy range where the optics are efficient in focusing X-rays. Herewe describe the Instrument, which is the major contribution of the Italian collaboration to the SmallExplorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will be flown in late 2021. The instrument, is composed of three Detector Units, based on this technique, and a Detector Service Unit. Three Mirror Modules provided by Marshall Space Flight Center focus X-rays onto the detectors. In the following we will show the technological choices, their scientific motivation and the results from the calibration of the Instrument.
IXPE will perform imaging, timing and energy resolved polarimetry in the 2-8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.
△ Less
Submitted 31 July, 2021;
originally announced August 2021.
-
Design, Construction, and Test of the Gas Pixel Detectors for the IXPE Mission
Authors:
L. Baldini,
M. Barbanera,
R. Bellazzini,
R. Bonino,
F. Borotto,
A. Brez,
C. Caporale,
C. Cardelli,
S. Castellano,
M. Ceccanti,
S. Citraro,
N. Di Lalla,
L. Latronico,
L. Lucchesi,
C. Magazzù,
G. Magazzù,
S. Maldera,
A. Manfreda,
M. Marengo,
A. Marrocchesi,
P. Mereu,
M. Minuti,
F. Mosti,
H. Nasimi,
A. Nuti
, et al. (69 additional authors not shown)
Abstract:
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collectin…
▽ More
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis -- particularly as far as the response to unpolarized radiation and the stability in time are concerned.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
X-ray polarimetry of the Crab nebula with PolarLight: polarization recovery after the glitch and a secular position angle variation
Authors:
Xiangyun Long,
Hua Feng,
Hong Li,
Jiahuan Zhu,
Qiong Wu,
Jiahui Huang,
Massimo Minuti,
Weichun Jiang,
Weihua Wang,
Renxin Xu,
Enrico Costa,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera
, et al. (2 additional authors not shown)
Abstract:
We report follow-up observations of the Crab nebula with the PolarLight X-ray polarimeter, which revealed a possible variation in polarization associated with a pulsar glitch in 2019. The new observations confirm that the polarization has recovered roughly 100 days after the glitch. With the new observations, we find that the polarization angle (PA) measured with PolarLight from the total nebular…
▽ More
We report follow-up observations of the Crab nebula with the PolarLight X-ray polarimeter, which revealed a possible variation in polarization associated with a pulsar glitch in 2019. The new observations confirm that the polarization has recovered roughly 100 days after the glitch. With the new observations, we find that the polarization angle (PA) measured with PolarLight from the total nebular emission has a difference of 18.0 +- 4.6 (deg) from that measured 42 years ago with OSO-8, indicating a secular evolution of polarization with either the Crab nebula or pulsar. The long-term variation in PA could be a result of multiple glitches in the history, magnetic reconnection or movement of synchrotron emitting structures in the nebula, or secular evolution of the pulsar magnetic geometry.
△ Less
Submitted 22 April, 2021;
originally announced April 2021.
-
Discrimination of background events in the PolarLight X-ray polarimeter
Authors:
Jiahuan Zhu,
Hong Li,
Hua Feng,
Jiahui Huang,
Xiangyun Long,
Qiong Wu,
Weichun Jiang,
Massimo Minuti,
Saverio Citraro,
Hikmat Nasimi,
Dongxin Yang,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri,
Paolo Soffitta,
Enrico Costa
Abstract:
PolarLight is a space-borne X-ray polarimeter that measures the X-ray polarization via electron tracking in an ionization chamber. It is a collimated instrument and thus suffers from the background on the whole detector plane. The majority of background events are induced by high energy charged particles and show ionization morphologies distinct from those produced by X-rays of interest. Comparing…
▽ More
PolarLight is a space-borne X-ray polarimeter that measures the X-ray polarization via electron tracking in an ionization chamber. It is a collimated instrument and thus suffers from the background on the whole detector plane. The majority of background events are induced by high energy charged particles and show ionization morphologies distinct from those produced by X-rays of interest. Comparing on-source and off-source observations, we find that the two datasets display different distributions on image properties. The boundaries between the source and background distributions are obtained and can be used for background discrimination. Such a means can remove over 70% of the background events measured with PolarLight. This approaches the theoretical upper limit of the background fraction that is removable and justifies its effectiveness. For observations with the Crab nebula, the background contamination decreases from 25% to 8% after discrimination, indicative of a polarimetric sensitivity of around 0.2 Crab for PolarLight. This work also provides insights into future X-ray polarimetric telescopes.
△ Less
Submitted 13 May, 2021; v1 submitted 23 March, 2021;
originally announced March 2021.
-
Modeling the in-orbit background of PolarLight
Authors:
Jiahui Huang,
Hua Feng,
Hong Li,
Xiangyun Long,
Dongxin Yang,
Weihe Zeng,
Qiong Wu,
Weichun Jiang,
Massimo Minuti,
Enrico Costa,
Fabio Muleri,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Zhi Zeng,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera
, et al. (1 additional authors not shown)
Abstract:
PolarLight is a gas pixel X-ray polarimeter mounted on a CubeSat, which was launched into a Sun-synchronous orbit in October 2018. We build a mass model of the whole CubeSat with the Geant4 toolkit to simulate the background induced by the cosmic X-ray background (CXB) and high energy charged particles in the orbit. The simulated energy spectra and morphologies of event images both suggest that th…
▽ More
PolarLight is a gas pixel X-ray polarimeter mounted on a CubeSat, which was launched into a Sun-synchronous orbit in October 2018. We build a mass model of the whole CubeSat with the Geant4 toolkit to simulate the background induced by the cosmic X-ray background (CXB) and high energy charged particles in the orbit. The simulated energy spectra and morphologies of event images both suggest that the measured background with PolarLight is dominated by high energy electrons, with a minor contribution from protons and the CXB. The simulation reveals that, in the energy range of 2-8 keV, there are roughly 28% of the background events are caused by energy deposit from a secondary electron with an energy of a few keV, in a physical process identical to the detection of X-rays. Thus, this fraction of background cannot be discriminated from X-ray events. The background distribution is uneven on the detector plane, with an enhancement near the edges. The edge effect is because high energy electrons tend to produce long tracks, which are discarded by the readout electronics unless they have partial energy deposits near the edges. The internal background rate is expected to be around 6 x 10^-3 counts/s/cm2 in 2-8 keV if an effective particle discrimination algorithm can be applied. This indicates that the internal background should be negligible for future focusing X-ray polarimeters with a focal size in the order of mm.
△ Less
Submitted 17 January, 2021;
originally announced January 2021.
-
Re-detection and a Possible Time Variation of Soft X-ray Polarisation from the Crab
Authors:
Hua Feng,
Hong Li,
Xiangyun Long,
Ronaldo Bellazzini,
Enrico Costa,
Qiong Wu,
Jiahui Huang,
Weichun Jiang,
Massimo Minuti,
Weihua Wang,
Renxin Xu,
Dongxin Yang,
Luca Baldini,
Saverio Citraro,
Hikmat Nasimi,
Paolo Soffitta,
Fabio Muleri,
Aera Jung,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro
, et al. (2 additional authors not shown)
Abstract:
The Crab nebula is so far the only celestial object with a statistically significant detection in soft x-ray polarimetry, a window that has not been explored in astronomy since the 1970s. However, soft x-ray polarimetry is expected to be a sensitive probe of magnetic fields in high energy astrophysical objects including rotation-powered pulsars and pulsar wind nebulae. Here we report the re-detect…
▽ More
The Crab nebula is so far the only celestial object with a statistically significant detection in soft x-ray polarimetry, a window that has not been explored in astronomy since the 1970s. However, soft x-ray polarimetry is expected to be a sensitive probe of magnetic fields in high energy astrophysical objects including rotation-powered pulsars and pulsar wind nebulae. Here we report the re-detection of soft x-ray polarisation after 40 years from the Crab nebula and pulsar with PolarLight, a miniature polarimeter utilising a novel technique onboard a CubeSat. The polarisation fraction of the Crab in the on-pulse phases was observed to decrease after a glitch of the Crab pulsar on July 23, 2019, while that of the pure nebular emission remained constant within uncertainty. The phenomenon may have lasted about 100 days. If the association between the glitch and polarisation change can be confirmed with future observations, it will place strong constraints on the physical mechanism of the high energy emission and glitch of pulsars.
△ Less
Submitted 10 November, 2020;
originally announced November 2020.
-
In-orbit Operation and Performance of the CubeSat Soft X-ray Polarimeter PolarLight
Authors:
Hong Li,
Xiangyun Long,
Hua Feng,
Qiong Wu,
Jiahui Huang,
Weichun Jiang,
Massimo Minuti,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgro,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri,
Paolo Soffitta,
Enrico Costa
Abstract:
PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we dis…
▽ More
PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we discuss how one can run a low-cost, shared CubeSat for space astronomy, and how CubeSats can play a role in modern space astronomy for technical demonstration, science observations, and student training.
△ Less
Submitted 2 September, 2020;
originally announced September 2020.
-
PolarLight: a CubeSat X-ray Polarimeter based on the Gas Pixel Detector
Authors:
Hua Feng,
Weichun Jiang,
Massimo Minuti,
Qiong Wu,
Aera Jung,
Dongxin Yang,
Saverio Citraro,
Hikmat Nasimi,
Jiandong Yu,
Ge Jin,
Jiahui Huang,
Ming Zeng,
Peng An,
Luca Baldini,
Ronaldo Bellazzini,
Alessandro Brez,
Luca Latronico,
Carmelo Sgrò,
Gloria Spandre,
Michele Pinchera,
Fabio Muleri,
Paolo Soffitta,
Enrico Costa
Abstract:
The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the fi…
▽ More
The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the field of view to 2.3 degrees. Filled with pure dimethyl ether (DME) at 0.8 atm and sealed by a beryllium window of 100 micron thick, with a sensitive area of about 1.4 mm by 1.4 mm, PolarLight allows us to observe the brightest X-ray sources on the sky, with a count rate of, e.g., ~0.2 counts/s from the Crab nebula. The PolarLight is 1U in size and mounted in a 6U CubeSat, which was launched into a low Earth Sun-synchronous orbit on October 29, 2018, and is currently under test. More launches with improved designs are planned in 2019. These tests will help increase the technology readiness for future missions such as the enhanced X-ray Timing and Polarimetry (eXTP), better understand the orbital background, and may help constrain the physics with observations of the brightest objects.
△ Less
Submitted 4 March, 2019;
originally announced March 2019.