PILOT balloon-borne experiment in-flight performance
Authors:
A. Mangilli,
G. Foënard,
J. Aumont,
A. Hughes,
B. Mot,
J-Ph. Bernard,
A. Lacourt,
I. Ristorcelli,
Y. Longval,
P. Ade,
Y. André,
L. Bautista,
P. deBernardis,
O. Boulade,
F. Bousqet,
M. Bouzit,
V. Buttice,
M. Charra,
B. Crane,
E. Doumayrou,
J. P. Dubois,
C. Engel,
M. Griffin,
S. Grabarnik,
P. Hargrave
, et al. (26 additional authors not shown)
Abstract:
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A first PILOT flight (flight#1) of the experiment took place from Timmins, Ontario, Canada, in September 2015 and a second flight (flight#2) took place from Alice Springs, Au…
▽ More
The Polarized Instrument for Long-wavelength Observation of the Tenuous interstellar medium (PILOT) is a balloon-borne experiment aiming at measuring the polarized emission of thermal dust at a wavelength of 240 mm (1.2 THz). A first PILOT flight (flight#1) of the experiment took place from Timmins, Ontario, Canada, in September 2015 and a second flight (flight#2) took place from Alice Springs, Australia in april 2017. In this paper, we present the inflight performance of the instrument during these two flights. We concentrate on performances during flight#2, but allude to flight#1 performances if significantly different. We first present a short description of the instrument and the flights. We determine the time constants of our detectors combining inflight information from the signal decay following high energy particle impacts (glitches) and of our internal calibration source. We use these time constants to deconvolve the data timelines and analyse the optical quality of the instrument as measured on planets. We then analyse the structure and polarization of the instrumental background. We measure the detector response flat field and its time variations using the signal from the residual atmosphere and of our internal calibration source. Finally, we analyze the detector noise spectral and temporal properties. The in-flight performances are found to be satisfactory and globally in line with expectations from ground calibrations. We conclude by assessing the expected in-flight sensitivity of the instrument in light of the above in-flight performances.
△ Less
Submitted 7 January, 2019; v1 submitted 16 April, 2018;
originally announced April 2018.
-
PILOT: a balloon-borne experiment to measure the polarized FIR emission of dust grains in the interstellar medium
Authors:
R. Misawa,
J-Ph. Bernard,
P. Ade,
Y. Andre,
P. deBernardis,
M. Bouzit,
M. Charra,
B. Crane,
J. P. Dubois,
C. Engel,
M. Griffin,
P. Hargrave,
B. Leriche,
Y. Longval,
S. Maes,
C. Marty,
W. Marty,
S. Masi,
B. Mot,
J. Narbonne,
F. Pajot,
G. Pisano,
N. Ponthieu,
I. Ristorcelli,
L. Rodriguez
, et al. (4 additional authors not shown)
Abstract:
Future cosmology space missions will concentrate on measuring the polarization of the Cosmic Microwave Background, which potentially carries invaluable information about the earliest phases of the evolution of our universe. Such ambitious projects will ultimately be limited by the sensitivity of the instrument and by the accuracy at which polarized foreground emission from our own Galaxy can be su…
▽ More
Future cosmology space missions will concentrate on measuring the polarization of the Cosmic Microwave Background, which potentially carries invaluable information about the earliest phases of the evolution of our universe. Such ambitious projects will ultimately be limited by the sensitivity of the instrument and by the accuracy at which polarized foreground emission from our own Galaxy can be subtracted out. We present the PILOT balloon project which will aim at characterizing one of these foreground sources, the polarization of the dust continuum emission in the diffuse interstellar medium. The PILOT experiment will also constitute a test-bed for using multiplexed bolometer arrays for polarization measurements. We present the results of ground tests obtained just before the first flight of the instrument.
△ Less
Submitted 13 October, 2014;
originally announced October 2014.
-
Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Chabot,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon
, et al. (9 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of c…
▽ More
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of cosmic ray impacts on the HFI detector modules has been undertaken to categorize and characterize the glitches, to correct the HFI time-ordered data, and understand the residual effects on Planck maps and data products. This paper presents an evaluation of the physical origins of glitches observed by the HFI detectors. In order to better understand the glitches observed by HFI in flight, several ground-based experiments were conducted with flight-spare HFI bolometer modules. The experiments were conducted between 2010 and 2013 with HFI test bolometers in different configurations using varying particles and impact energies. The bolometer modules were exposed to 23 MeV protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm $α$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data from the HFI ground-based preflight tests were used to further characterize the glitches and compare glitch rates with statistical expectations under laboratory conditions. Test results provide strong evidence that the dominant family of glitches observed in flight are due to cosmic ray absorption by the silicon die substrate on which the HFI detectors reside. Glitch energy is propagated to the thermistor by ballistic phonons, while there is also a thermal diffusion contribution. The implications of these results for future satellite missions, especially those in the far-infrared to sub-millimetre and millimetre regions of the electromagnetic spectrum, are discussed.
△ Less
Submitted 2 September, 2014; v1 submitted 26 March, 2014;
originally announced March 2014.
-
Characterization and Physical Explanation of Energetic Particles on Planck HFI Instrument
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon,
A. Pelissier
, et al. (8 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and…
▽ More
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft. Protons with an energy above 40MeV can penetrate the focal plane unit box causing two different effects: glitches in the raw data from direct interaction of cosmic rays with detectors (producing a data loss of about 15% at the end of the mission) and thermal drifts in the bolometer plate at 100mK adding non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made strong efforts in order to correct for this effect on the time ordered data and final Planck maps. This work intends to give a view of the physical explanation of the glitches observed in the HFI instrument in-flight. To reach this goal, we performed several ground-based experiments using protons and $α$ particles to test the impact of particles on the HFI spare bolometers with a better control of the environmental conditions with respect to the in-flight data. We have shown that the dominant part of glitches observed in the data comes from the impact of cosmic rays in the silicon die frame supporting the micro-machinced bolometric detectors propagating energy mainly by ballistic phonons and by thermal diffusion. The implications of these results for future satellite missions will be discussed.
△ Less
Submitted 22 March, 2014;
originally announced March 2014.
-
In-flight calibration and verification of the Planck-LFI instrument
Authors:
Anna Gregorio,
Francesco Cuttaia,
Aniello Mennella,
Marco Bersanelli,
Michele Maris,
Peter Meinhold,
Maura Sandri,
Luca Terenzi,
Maurizio Tomasi,
Fabrizio Villa,
Marco Frailis,
Gianluca Morgante,
Dave Pearson,
Andrea Zacchei,
Paola Battaglia,
Reginald Christophe Butler,
Richard Davis,
Cristian Franceschet,
Enrico Franceschi,
Samuele Galeotta,
Rodrigo Leonardi,
Steve Lowe,
Nazzareno Mandolesi,
Frederick Melot,
Luis Mendes
, et al. (18 additional authors not shown)
Abstract:
In this paper we discuss the Planck-LFI in-flight calibration campaign. After a brief overview of the ground test campaigns, we describe in detail the calibration and performance verification (CPV) phase, carried out in space during and just after the cool-down of LFI. We discuss in detail the functionality verification, the tuning of the front-end and warm electronics, the preliminary performance…
▽ More
In this paper we discuss the Planck-LFI in-flight calibration campaign. After a brief overview of the ground test campaigns, we describe in detail the calibration and performance verification (CPV) phase, carried out in space during and just after the cool-down of LFI. We discuss in detail the functionality verification, the tuning of the front-end and warm electronics, the preliminary performance assessment and the thermal susceptibility tests. The logic, sequence, goals and results of the in-flight tests are discussed. All the calibration activities were successfully carried out and the instrument response was comparable to the one observed on ground. For some channels the in-flight tuning activity allowed us to improve significantly the noise performance.
△ Less
Submitted 8 July, 2013;
originally announced July 2013.
-
Planck early results: first assessment of the High Frequency Instrument in-flight performance
Authors:
Planck HFI Core Team,
P. A. R. Ade,
N. Aghanim,
R. Ansari,
M. Arnaud,
M. Ashdown,
J. Aumont,
A. J. Banday,
M. Bartelmann,
J. G. Bartlett,
E. Battaner,
K. Benabed,
A. Benot,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
F. Boulanger,
T. Bradshaw,
E. Brelle,
M. Bucher,
P. Camus
, et al. (141 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometer…
▽ More
The Planck High Frequency Instrument (HFI) is designed to measure the temperature and polarization anisotropies of the Cosmic Microwave Background and galactic foregrounds in six wide bands centered at 100, 143, 217, 353, 545 and 857 GHz at an angular resolution of 10' (100 GHz), 7' (143 GHz), and 5' (217 GHz and higher). HFI has been operating flawlessly since launch on 14 May 2009. The bolometers cooled to 100 mK as planned. The settings of the readout electronics, such as the bolometer bias current, that optimize HFI's noise performance on orbit are nearly the same as the ones chosen during ground testing. Observations of Mars, Jupiter, and Saturn verified both the optical system and the time response of the detection chains. The optical beams are close to predictions from physical optics modeling. The time response of the detection chains is close to pre-launch measurements. The detectors suffer from an unexpected high flux of cosmic rays related to low solar activity. Due to the redundancy of Planck's observations strategy, the removal of a few percent of data contaminated by glitches does not affect significantly the sensitivity. The cosmic rays heat up significantly the bolometer plate and the modulation on periods of days to months of the heat load creates a common drift of all bolometer signals which do not affect the scientific capabilities. Only the high energy cosmic rays showers induce inhomogeneous heating which is a probable source of low frequency noise.
△ Less
Submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results. II. The thermal performance of Planck
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoit,
J. P. Bernard,
M. Bersanelli,
P. Bhandari,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borders,
J. Borrill,
F. R. Bouchet,
B. Bowman
, et al. (203 additional authors not shown)
Abstract:
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisf…
▽ More
The performance of the Planck instruments in space is enabled by their low operating temperatures, 20K for LFI and 0.1K for HFI, achieved through a combination of passive radiative cooling and three active mechanical coolers. The scientific requirement for very broad frequency coverage led to two detector technologies with widely different temperature and cooling needs. Active coolers could satisfy these needs; a helium cryostat, as used by previous cryogenic space missions (IRAS, COBE, ISO, Spitzer, AKARI), could not. Radiative cooling is provided by three V-groove radiators and a large telescope baffle. The active coolers are a hydrogen sorption cooler (<20K), a 4He Joule-Thomson cooler (4.7K), and a 3He-4He dilution cooler (1.4K and 0.1K). The flight system was at ambient temperature at launch and cooled in space to operating conditions. The HFI bolometer plate reached 93mK on 3 July 2009, 50 days after launch. The solar panel always faces the Sun, shadowing the rest of Planck, andoperates at a mean temperature of 384K. At the other end of the spacecraft, the telescope baffle operates at 42.3K and the telescope primary mirror operates at 35.9K. The temperatures of key parts of the instruments are stabilized by both active and passive methods. Temperature fluctuations are driven by changes in the distance from the Sun, sorption cooler cycling and fluctuations in gas-liquid flow, and fluctuations in cosmic ray flux on the dilution and bolometer plates. These fluctuations do not compromise the science data.
△ Less
Submitted 2 January, 2012; v1 submitted 11 January, 2011;
originally announced January 2011.